Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEVEL WIDTHS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

New calorimetric all-particle energy spectrum

Both the maximum size N sub m and the sea level muon size N sub mu have been used separately to find the all-particle energy spectrum in the air shower domain. However the conversion required, whether from N sub m to E or from N sub mu to E, has customarily been carried out by means of calculations based on an assumed cascase model. It is shown here that by combining present data on N sub m and N sub mu spectra with data on: (1); the energy spectrum of air shower muons and (2) the average width of the electron profile, one can obtain empirical values of the N sub m to E and N sub mu to E conversion factors, and an empirical calorimetric all-particle spectrum, in the energy range 2 x 10 to the 6th power E 2 x 10 to the 9th power GeV.

Linsley, J.↗

Atomistic tight-binding study of electronic structure and interband optical transitions in GaBi{sub x}As{sub 1−x}/GaAs quantum wells

Large-supercell tight-binding calculations are presented for GaBi{sub x}As{sub 1−x}/GaAs single quantum wells (QWs) with Bi fractions x of 3.125% and 12.5%. Our results highlight significant distortion of the valence band states due to the alloy disorder. A large full-width-half-maximum (FWHM) is estimated in the ground state interband transition energy (≈33 meV) at 3.125% Bi, consistent with recent photovoltage measurements for similar Bi compositions. Additionally, the alloy disorder effects are predicted to become more pronounced as the QW width is increased. However, they are less strong at the higher Bi composition (12.5%) required for the design of temperature-stable lasers, with a calculated FWHM of ≈23.5 meV at x = 12.5%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intraband Raman laser gain in a boron nitride coupled quantum well

On-centre impurity related electronic and optical properties are studied in a Boron nitride coupled quantum well. Confined energies for the intraband transition are investigated by studying differential cross section of electron Raman scattering taking into consideration of spatial confinement in a B{sub 0.3}Ga{sub 0.7}N/BN coupled quantum well. Raman gain as a function of incident optical pump intensity is computed for constant well width. The enhancement of Raman gain is observed with the application of pump power. The results can be applied for the potential applications for fabricating some optical devices such as optical switches, infrared photo-detectors and electro-optical modulator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sturmian expansions for two-electron atomic systems: Singly and doubly excited states

We present a configuration interaction (CI) method based on the Sturmian expansion for bound states of a two-electron atomic system. These Sturmian functions are solutions of one-electron quantum mechanical problems, where the eigenvalue is the magnitude of a short-range potential. Also, they fulfill the long-range boundary conditions of Coulomb potentials. We choose to expand the Sturmians of the CI basis using L{sup 2} Laguerre-type functions. We compute ground and single-excited states energies for He and H{sup -}. Moreover, we are able to obtain energies and widths of double excited states of He, using a Sturmian basis with outgoing boundary conditions. In all cases, our ansatz outperforms other CI calculations, for similar basis size.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectroscopic factors, overlaps, and isospin symmetry from an R -matrix point of view

Background: Spectroscopic factors, overlaps, and isospin symmetry are often used in conjunction with single-particle wave functions for the phenomenological analysis of nuclear structure and reactions. Many differing prescriptions for connecting these quantities to physically relevant asymptotic normalization constants or widths are available in the literature, but their relationship and degree of validity are not always clear. Purpose: This paper derives relationships among the above quantities of interest using well-defined methodology and starting assumptions. Method: R -matrix theory is used as the primary tool to interoperate among the quantities of interest to this work. Particular attention is paid to effects arising from beyond the nuclear surface, where isospin symmetry is strongly violated. Results: Relationships between the quantities of interest are derived. Example applications of these methods to mirror levels in nucleon + 12 C, nucleon + 16 O, and nucleon + 26 Al are presented. A new approach to multilevel mirror symmetry is derived and applied to the first three 2 + states of 18 O and 18 Ne. Conclusions: In this work, the relationship between the quantities of interest is clarified and certain procedures are recommended. It is found that the asymptotic normalization constant of the second 2 + state in 18 Ne deduced from the mirror state in 18 O is significantly larger than found in previous work. This finding has the effect of increasing the 17 F($\textit{p,γ}$) 18 Ne reaction rate in novae.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-TeP1-04: Deriving Spot Shape Criteria for Proton Pencil Beam Scanning

Purpose: The shape of a single beam in proton PBS influences the resulting dose distribution. Spot profiles are modelled as two-dimensional Gaussian (single/ double) distributions in treatment planning systems (TPS). Impact of slight deviations from an ideal Gaussian on resulting dose distributions is typically assumed to be small due to alleviation by multiple Coulomb scattering (MCS) in tissue and superposition of many spots. Quantitative limits are however not clear per se. Methods: A set of 1250 deliberately deformed profiles with sigma=4 mm for a Gaussian fit were constructed. Profiles and fit were normalized to the same area, resembling output calibration in the TPS. Depth-dependent MCS was considered. The deviation between deformed and ideal profiles was characterized by root-mean-squared deviation (RMSD), skewness/ kurtosis (SK) and full-width at different percentage of maximum (FWxM). The profiles were convolved with different fluence patterns (regular/ random) resulting in hypothetical dose distributions. The resulting deviations were analyzed by applying a gamma-test. Results were compared to measured spot profiles. Results: A clear correlation between pass-rate and profile metrics could be determined. The largest impact occurred for a regular fluence-pattern with increasing distance between single spots, followed by a random distribution of spot weights. The results are strongly dependent on gamma-analysis dose and distance levels. Pass-rates of >95% at 2%/2 mm and 40 mm depth (=70 MeV) could only be achieved for RMSD<10%, deviation in FWxM at 20% and root of quadratic sum of SK <0.8. As expected the results improve for larger depths. The trends were well resembled for measured spot profiles. Conclusion: All measured profiles from ProBeam sites passed the criteria. Given the fact, that beam-line tuning can result shape distortions, the derived criteria represent a useful QA tool for commissioning and design of future beam-line optics.

07 ISOTOPE AND RADIATION SOURCES↗

A new model for Mars atmospheric dust based upon analysis of ultraviolet through infrared observations from Mariner 9, Viking, and Phobos

We propose key modifications to the Toon et al. (1977) model of the particle size distribution and composition of Mars atmospheric dust, based on a variety of spacecraft and wavelength observations of the dust. A much broader (r(sub eff) variance approximately 0.8 micrometers), smaller particle size (r(sub mode) approximately 0.02 micrometers) distribution coupled with a 'palagonite-like' composition is argued to fit the complete ultraviolet-to-30-micrometer absorption properties of the dust better than the montmorillonite-basalt, r(sub eff) variance = 0.4 micrometers, r(sub mode) = 0.40 dust model of Toon et al. Mariner 9 (infrared interferometer spectrometer) IRIS spectra of high atmospheric dust opacities during the 1971-1972 Mars global dust storm are analyzed in terms of the Toon et al. dust model, and a Hawaiian palagonite sample (Rousch et al., 1991) with two different size distribution models incorporating smaller dust particle sizes. Viking Infrared Thermal Mapper (IRTM) emmission-phase-function (EPF) observations at 9 micrometers are analyzed to retrieve 9-micrometer dust opacities coincident with solar band dust opacities obtained from the same EPF sequences (Clancy and Lee, 1991). These EPF dust opacities provide an independent measurement of the visible/9-micrometer extinction opacity ratio (greater than or = 2) for Mars atmospheric dust, which is consistent with a previous measurement by Martin (1986). Model values for the visible/9-micrometer opacity ratio and the ultraviolet and visible single-scattering albedos are calculated for the palagonite model with the smaller particle size distributions compared to the same properties for the Toon et al. model of dust. The montmorillonite model of the dust is found to fit the detailed shape of the dust 9-micrometer absorption well. However, it predicts structured, deep aborptions at 20 micrometers which are not observed and requires a separate ultraviolet-visible absorbing component to match the observed behavior of the dust in this wavelength region. The modeled palagonite does not match the 8-to 9-micrometer absorption presented by the dust in the IRIS spectra, probably due to its low SiO2 content (31%). However, it does provide consistent levels of ultraviolet/visible absorption, 9-to 12-micrometer absorption, and a lack of structured absorption at 20 micrometers. The ratios of dust extinction opacities at visible, 9 micrometers, and 30 micrometers are strongly affected by the dust particle size distribution. The Toon et al. dust size distribution (r(sub mode) = 0.40,r(sub eff) variance = 0.4 micrometers, r(sub cwmu) = 2.7 micrometers) predicts the correct ratio of the 9- to 30-micrometer opacity, but underpredicts the visible/9-micrometer opacity ratio considerably (1 versus greater than or = 2). A similar particle distribution width with smaller particle sizes (r(sub mode) = 0.17, r(sub eff) variance = 0.4 micrometers, r(sub cwmu) = 1.2 micrometers) will fit the observed visible/9-micrometer opacity ratio, but overpredicts the observed 9-micrometer/30-micrometer opacity ratio. A smaller and much broader particle size distribution (r(sub mode) = 0.002, r(sub eff) variance = 0.8 micrometers, r(sub cwmu) = 1.8 micrometers) can fit both dust opacity ratios. Overall, the nanocrystalline structure of palagonite coupled with a smaller, broader distribution of dust particle sizes provides a more consistent fit than the Toon et al. model of the dust to the IRIS spectra, the observed visible/9-micrometer dust opacity ratio, the Phobos occulation measurements of the dust particle sizes (Chassefiere et al., 1992), and the weakness of surface near IR absorptions expected for clay minerals (Clark, 1992; Bell and Crisp, 1993).

Clancy, R. T.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

Multicomponent dynamics of coupled quantum subspaces and field-induced molecular ionizations

To describe successive ionization steps of a many-electron atom or molecule driven by an ultrashort, intense laser pulse, we introduce a hierarchy of successive two-subspace Feshbach partitions of the N-electron Hilbert space, and solve the partitioned time-dependent Schrödinger equation by a short-time unitary algorithm. The partitioning scheme allows one to use different level of theory to treat the many-electron dynamics in different subspaces. We illustrate the procedure on a simple two-active-electron model molecular system subjected to a few-cycle extreme Ultra-Violet (XUV) pulse to study channel-resolved photoelectron spectra as a function of the pulse's central frequency and duration. We observe how the momentum and kinetic-energy distributions of photoelectrons accompanying the formation of the molecular cation in a given electronic state (channel) change as the XUV few-cycle pulse's width is varied, from a form characteristic of an impulsive ionization regime, corresponding to the limit of a delta-function pulse, to a form characteristic of multiphoton above-threshold ionization, often associated with continuous-wave infinitely long pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tree-ring growth and wood chemistry response to manipulated precipitation variation for two temperate Quercus species

We examined the relationship among ambient and manipulated precipitation, wood chemistry, and their relationship with radial growth for two oak species in eastern Tennessee. The study took place on the Walker Branch Throughfall Displacement Experiment (TDE) site, located at the Oak Ridge National Laboratory in Oak Ridge, TN. Two dominant species, white oak (Quercus alba) and chestnut oak (Quercus prinus), were selected for study from a 13-year experiment of whole-stand precipitation manipulation (wet, ambient and dry). The relationships between tree-ring width and climate were compared for both species to determine the impact of precipitation manipulations on ring width index. This study used experimental spectroscopy techniques to measure the sensitivity of tree-ring responses to directional changes in precipitation over 13 years, and the results suggest that oaks at this study site are resilient to imposed changes, but sensitive to inter-annual variations in climate. Laser-induced breakdown spectroscopy (LIBS) allowed us to measure nutrient intensities (similar to element concentrations) at 0.5-1.0 mm spacing along the radial growth axis of trees growing in the wet, ambient, and dry treatment sites. A difference in stemwood nutrient levels was observed between the two oak species and among the three treatments. Significant variation in element intensity was observed across treatments for some elements (Ca, K, Mg, Na, N and P) suggesting the potential for long-term impacts on growth under a changing climate regimes for southeastern oaks.

09 BIOMASS FUELS↗

Radiation effects on p+n InP junctions grown by MOCVD

The superior radiation resistance of InP over other solar cell materials such as Si or GaAs has prompted the development of InP cells for space applications. The early research on radiation effects in InP was performed by Yamaguchi and co-workers who showed that, in diffused p-InP junctions, radiation-induced defects were readily annealed both thermally and by injection, which was accompanied by significant cell recovery. More recent research efforts have been made using p-InP grown by metalorganic chemical vapor deposition (MOCVD). While similar deep level transient spectroscopy (DLTS) results were found for radiation induced defects in these cells and in diffused junctions, significant differences existed in the annealing characteristics. After injection annealing at room temperature, Yamaguchi noticed an almost complete recovery of the photovoltaic parameters, while the MOCVD samples showed only minimal annealing. In searching for an explanation of the different annealing behavior of diffused junctions and those grown by MOCVD, several possibilities have been considered. One possibility is the difference in the emitter structure. The diffused junctions have S-doped graded emitters with widths of approximately 0.3 micrometers, while the MOCVD emitters are often doped with Si and have widths of approximately 300A (0.03 micrometers). The difference in the emitter thickness can have important effects, e.g. a larger fraction of the total photocurrent is generated in the n-type material for thicker emitters. Therefore the properties of the n-InP material may explain the difference in the observed overall annealing behavior of the cells.

Messenger, Scott R.↗

Effects of signal analysis parameters and noise removal on measured aircraft spectra

Special techniques must be applied when analyzing acoustic noise data from nonstationary sources such as aircraft flyover measurements. Since the Fourier transform is time dependent, the noise signal is divided into short time segments by introducing a window function so that the spectral characteristics remain reasonably stationary. Reducing the window width reduces the frequency resolution while increasing the window duration can lead to spectral smearing. A trade-off must be made between time resolution and frequency resolution. The effects of varying the window duration on narrow-band acoustic spectra and thus the frequency bin width are addressed in this study. The influence of window functions (rectangular, Hamming, etc.) are also investigated. Both a tonal noise source, XV-15 aircraft in the airplane mode, and a broadband noise source, a F-18 aircraft, are considered. When dealing with flight test data, not only is the signal nonstationary, often it is contaminated by both ambient background noise and internal noise generated by the data acquisition system and power generators. Since generator noise is highly tonal, this can be particularly troublesome when computing tone-corrected perceived noise level (PNLT). A scheme is presented in this paper to eliminate unwanted background and internal noise.

Kelly, Jeffrey J.↗

A new model for Mars atmospheric dust based upon analysis of ultraviolet through infrared observations from Mariner 9, Viking, and Phobos

We propose key modifications to the Toon et al. (1977) model of the particle size distribution and composition of Mars atmospheric dust, based on a variety of spacecraft and wavelength observations of the dust. A much broader (r(sub eff)variance-0.8 micron), smaller particle size (r(sub mode)-0.02 microns) distribution coupled with a "palagonite-like" composition is argued to fit the complete ultraviolet-to-30-micron absorption properties of the dust better than the montmorillonite-basalt r(sub eff)variance= 0.4 micron, r(sub mode)= 0.40 micron dust model of Toon et al. Mariner 9 (infrared interferometer spectrometer) IRIS spectra of high atmospheric dust opacities during the 1971 - 1972 Mars global dust storm are analyzed in terms of the Toon et al. dust model, and a Hawaiian palagonite sample with two different size distribution models incorporating smaller dust particle sizes. Viking Infrared Thermal Mapper (IRTM) emission-phase-function (EPF) observations at 9 microns are analyzed to retrieve 9-micron dust opacities coincident with solar band dust opacities obtained from the same EPF sequences. These EPF dust opacities provide an independent measurement of the visible/9-microns extinction opacity ratio (> or equal to 2) for Mars atmospheric dust, which is consistent with a previous measurement by Martin (1986). Model values for the visible/9-microns opacity ratio and the ultraviolet and visible single-scattering albedos are calculated for the palagonite model with the smaller particle size distributions and compared to the same properties for the Toon et al. model of dust. The montmorillonite model of the dust is found to fit the detailed shape of the dust 9-micron absorption well. However, it predicts structured, deep absorptions at 20 microns which are not observed and requires a separate ultraviolet-visible absorbing component to match the observed behavior of the dust in this wavelength region. The modeled palagonite does not match the 8- to 9-micron absorption presented by the dust in the IRIS spectra, probably due to its low SiO2 content (31%). However, it does provide consistent levels of ultraviolet/visible absorption, 9- to 12-micron absorption, and a lack of structured absorption at 20 microns. The ratios of dust extinction opacities at visible, 9 microns, and 30 microns are strongly affected by the dust particle size distribution. The Toon et al. dust size distribution (r(sub mode)= 0.40, r(sub eff)variance= 0.4 microns, r(sub cw mu)= 2.7 microns) predicts the correct ratio of the 9- to 30-micron opacity, but underpredicts the visible/9-micron opacity ratio considerably (1 versus > or equal to 2). A similar particle distribution width with smaller particle sizes (r(sub mode)= 0.17, r(sub eff)variance= 0.4 microns, r(sub cw mu)=1.2 microns) will fit the observed visible/9-micron opacity ratio, but overpredicts the observed 9-micron/30-micron opacity ratio. A smaller and much broader particle size distribution (r(sub mode)= 0.02, r(sub eff)variance= 0.8 microns, r(sub cw mu)= 1.8 microns) can fit both dust opacity ratios. Overall, the nanocrystalline structure of palagonite coupled with a smaller, broader distribution of dust particle sizes provides a more consistent fit than the Toon et al. model of the dust to the IRIS spectra, the observed visible/9-micron dust opacity ratio, the Phobos occultation measurements of dust particle sizes, and the weakness of surface near IR absorptions expected for clay minerals.

Clancy, R. T.↗

Population transfer to the E {sup 1}SIGMA{sub g} excited electronic state of Li{sub 2} by femtosecond laser pulses with all possible interstate radiative couplings

Population transfer to the excited electronic state E {sup 1}SIGMA{sub g} of Li{sub 2} by transform limited delayed femtosecond pulses has been investigated. The validity of the usual neglect of some field-molecule coupling terms in such transfers, accomplished using counterintuitively ordered pulses through ''adiabatic passage on light-induced potentials,'' has been reexamined. It has been found that such an approximation cannot be justified in the case of the ladder system X {sup 1}SIGMA{sup +}{sub g}-A {sup 1}SIGMA{sup +}{sub u}-E {sup 1}SIGMA{sup +}{sub g} of Li{sub 2}. However, the transfer can be successfully accomplished over a range of pulse parameters, which is more restricted than those obtained with the usual approximation. In this scheme, when two pulses with a small frequency difference between them are used, the lower-frequency pulse must precede the higher-frequency pulse for a successful transfer. We introduce an adiabatic representation, appropriate to this full coupling case, for examining the mechanism of transfer. In our representation the initial wave packet may be prepared on more than one adiabatic state, and at an early stage it is transferred to a single adiabatic surface after which the evolution mostly proceeds adiabatically. The vibrational analysis of the final wave packet shows that for short pulses high vibrational states are generally excited, while for pulses with larger width low-lying vibrational states are preferred in cases where successful transfer occurs. These results can be understood in terms of the motion of the wave packet on the time-dependent adiabatic potentials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evidence for the J{sup p}=1/2{sup +} narrow state at 1650 MeV in the photoproduction of K{Lambda}

We have investigated the existence of the J{sup p}=1/2{sup +} narrow resonance predicted by the chiral soliton model by utilizing the kaon photoproduction process {gamma}+p{yields}K{sup +}+{Lambda}. For this purpose we have constructed two phenomenological models based on our previous effective Lagrangian model, which are able to describe kaon photoproduction from threshold up to W=1730 MeV. By varying the mass (width) of an inserted P{sub 11} resonance from 1620 to 1730 MeV (0.1 to 1 MeV and 1 to 10 MeV) a number of fits have been performed in order to search for the resonance mass. Our result indicates that the most promising candidate mass (width) of this resonance is 1650 MeV (5 MeV). Although our calculation does not exclude the possibility of narrow resonances with masses of 1680, 1700, and 1720 MeV, the mass of 1650 MeV is obtained for all phenomenological models used in this investigation. Variations of the resonance width and K{Lambda} branching ratio are found to have a mild effect on the {chi}{sup 2}. The possibility that the obtained result originates from other resonance states is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron Spin Resonance Study of Fe3+ and Mn2+ Ions in 17-Year-Old Nuclear-Waste-Glass Simulants Containing PuO2 with Different Degrees of 238Pu Substitution

Three samples of a model nuclear waste glass, DRG-P1, P2, and P3, were prepared at PNNL in 1982 with identical chemical compositions but were respectively batched with 0.0, 0.1, and 0.9 wt% of 238PuO2 (half life 87.8 years) partially replacing the 1.0 wt% 239PuO2 present in DRG-P1. In 1999, samples of these glasses were sent to the Naval Research Laboratory for electron spin resonance (ESR) measurements. No radiation-induced point defects were observed. Profound alpha decay-induced changes in the ESR spectra of the batched iron-group ions were found. The spectra recorded for DRG-P1 were shown by absolute spin counts to have ESR intensities equivalent to ~85% of the sum of the batched 8.28 mole% Fe3+ and 2.79 mole% Mn2+, assuming all of those ions to behave as paramagnetic S=5/2 states at room temperature. Separate experiments and calculations ruled out the possibility of precipitated magnetite-like precipitates comprising even so much as 0.01% of the total iron. A relatively weak ESR spectral feature observed at g=4.3 is the known signature of dilute Fe3+ in glasses. However, the strongest ESR signal was found to be characterized by a first-derivative zero crossing at g=2.06 and a peak-to-peak derivative linewidth of ~150 mT, which is virtually invariant in shape with both measurement temperature and alpha-decay dose. It was discovered that these broad line shapes could be accurately simulated as weighted sums of Lorentzian shape functions of differing widths but having the same g value. The absence of any measurable anisotropy in the broad line, coupled with the temperature invariance of its width, imply the existence of extremely strong exchange interactions within clusters of Fe3+, Fe2+, Mn2+, and Ni2+ ions characterized by extremely short-range magnetic order. The result is a speromagnetic system rather than exhibiting a distinct Néel temperature. The most evident ESR effect of 17 years of 238Pu decay is the (irreversible) lowering of the intensity of the "broad line" in rough proportion to the amount of 238Pu in the sample, with concomitant increases in the amplitude of the g=4.3 feature. It was additionally observed that cooling these glasses to successively lower temperatures gives rise to reversible lowering of the broad-line intensity and increasing of the strength of the g=4.3 feature when compared with theoretical expectation for non-interacting paramagnets. The truly remarkable observation that the broad lines could be simulated as weighted sums of pure Lorentzian functions of differing widths fortuitously opened the way for high precision measurements of the ESR intensities of experimental spectra that are far broader than the magnetic field range of the available laboratory electromagnets. The areas under the simulated absorption curves fitted to the experimental spectra in the manner described provided an empirical measure of the degrees to which the present model nuclear waste glasses had been affected by alpha-decay self irradiation. Specifically, the broad-line ESR integrated-intensity data as a function of 238Pu alphadecay dose (proportional to the 238Pu doping level in these fixed-time experiments) proved to be accurately fitted by a simple saturating exponential function asymptotic to zero for infinite-time self irradiation. This result promises a precise means of extrapolating thousands of years into the future the process of "super-vitrification" that results from the creation and rapid quenching of thermal spikes due to alpha decay in glasses immobilizing 239Pu and other actinide elements. In addition, because the ESR spectra of several very different candidate high-level nuclear waste (HLW) glass compositions containing even higher amounts of Fe2O3 are also shown here to be decomposable into sums of pure Lorentzians, the analytical method we describe should be applicable to these and many other HLW glasses containing both iron-group oxides and radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploiting the Dynamic Relationship between Peptide Separation Quality and Peptide Coisolation in a Multiple-Peptide Matches-per-Spectrum Approach Offers a Strategy To Optimize Bottom-Up Proteomics Throughput and Depth

We present that peptide cofragmentation leads to chimeric MS/MS spectra that negatively impact traditional single-peptide match-per-spectrum (sPSM) search strategies in proteomics. The collection of chimeric spectra is influenced by peptide coelution and the width of precursor isolation windows. Although peptide cofragmentation can be reduced by advanced chromatography, such as UHPLC and 2D-HPLC separation schemes, and narrower isolation windows, chimeric spectra can still be as high as 30–50% of the total MS/MS spectra collected. Alternatively, cofragmented peptides in chimeric spectra and the use of wider isolation windows benefit multiple-peptide matches-per-spectrum (mPSM) algorithms, such as CharmeRT, which facilitate the identification of several cofragmented peptides. Considering recent advancements in LC and mPSM methodologies, we present a comprehensive examination of the levels of chimeric spectra collected in the analysis of a HeLa digest measured using different LC modes of separation and isolation windows and compare the depth of identifications obtained when these data are annotated using a sPSM or a mPSM approach. Our results demonstrate that MS/MS data derived from 1D-HPLC strategies under different gradient schemes and searched with CharmeRT yielded higher average numbers of PSMs (11%–49%), peptide analytes (10%–16%), and peptide sequences (3%–10%) compared to data derived from 1D-UHPLC runs but searched with a sPSM strategy. Interestingly, data from a 2D-HPLC separation strategy benefits more from the application of CharmeRT results when compared to a 50 cm 1D-UHPLC column employing a 500 min gradient. In conclusion, these results provide new insights into how to better configure LC-MS/MS measurements for improved throughput and peptide identification in complex proteomes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients

Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with a limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.

60 APPLIED LIFE SCIENCES↗