Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Diffusion of Mn in GaAs studied by quantitative time-of-flight secondary ion mass spectrometry

Diffusion coefficients and the activation energy for Mn diffusion in ion-implanted and layered epitaxial structures of Ga{sub 1-x}Mn{sub x}As/GaAs are reported from quantitative time-of-flight secondary ion mass spectrometry. Samples are annealed between the growth temperature (as low as 200 deg. C) and approximately 400 deg. C. This temperature range is reported to improve the Curie temperature, which is important for the spintronic applications of these materials. Quantitative diffusion information is obtained by calibrating the Mn concentration to ion-implanted standards and the depth scale to profilometry measurements. Depth profiles obtained for ion-implanted Mn in GaAs at a dose of 1.35x10{sup 15} atoms/cm{sup 2} show increased Mn concentration within the top 5 nm of the sample but otherwise reveal no significant differences in the implantation shape after annealing up to 350 deg. C. For a higher implantation dose of 8.10x10{sup 15} Mn atoms/cm{sup 2}, diffusion is initiated after annealing at 300 deg. C with more significant diffusion at higher temperatures. The analysis of annealed epitaxial films of even higher concentration (Ga{sub 0.89}Mn{sub 0.11}As) exhibits diffusion at all temperatures measured (200-400 deg. C) and an activation energy of 0.67+-0.09 eV is calculated by fitting the profiles to an error function.

36 MATERIALS SCIENCE↗

Angle performance on optima MDxt

Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).

43 PARTICLE ACCELERATORS↗

Improvement in the photocurrent collection due to enhanced absorption of light by synthesizing staggered layers of silver nanoclusters in silicon

The quest for increased efficiency of solar cells has driven the research in synthesizing photovoltaic cells involving Si based materials. The efficiency of solar cells involving crystalline Si is stalled around 25% for the last decade. Recently Shi et al. had shown that light trapping can be enhanced by fabricating double layers of Ag nanoparticles in silicon based materials. The light trapping is critically important in a photo devices such as solar cells in order to increase light absorption and efficiency. In the present work, we report enhancement in the absorption of light in Ag ion implanted Si substrates. Multiple low energies Ag ions, ranging from ∼80 keV to ∼30 keV, with different fluences ranging from ∼1 × 10{sup 16} to ∼1 × 10{sup 17} atoms/cm{sup 2} were sequentially implanted into commercially available Si (100) substrates followed by post-thermal annealing to create different sizes of Ag nanoclusters (NC) at different depths in the top 100 nm of the Si. The absorbance of light is increased in Ag implanted Si with a significant increase in the current collection in I-V (current-voltage) photo switching measurements. The experimental photovoltaic cells fabricated with the Ag-implanted Si samples were optically characterized under AM (air mass) 1.5 solar radiation conditions (∼1.0 kW/m{sup 2}). An enhancement in the charge collection were measured in the annealed samples, where prominent Ag NCs were formed in the Si matrix compared to the as-implanted samples with amorphous layers. We believe the enhancement of the photo-current density from the samples with Ag NC is due to the improvement of efficiency of charge collection of e{sup −}-h{sup +} pairs produced by the incident light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spontaneous wrinkling of soft matter by energetic deposition of Cr and Au

Wrinkling of stiff thin films deposited on compliant substrates is an effect that has been broadly investigated. However, wrinkling consequent to metal ion implantation has been less studied. In the work described here, we have explored the sub-micron wrinkling phenomena that spontaneously occur when metal ions (Au and Cr) are implanted with energy of a few tens of electron volts (49 eV for Au and 72 eV for Cr) into a compliant material (PDMS). This very low energy ion implantation was performed using a Filtered Cathodic Vacuum Arc technique, a process often referred to as energetic deposition or energetic condensation. For comparison, Au and Cr depositions with similar doses were also done using a sputtering technique (with lower particle energy of approximately 2 eV), and no wrinkle formation was then observed. In this way, we can discuss the role of ion energy in wrinkle formation. Depth profiles of the implanted material were calculated using the Tridyn computer simulation code for each metal, for several implantation doses. UV-vis absorption spectroscopy analysis confirmed the presence of metal nanoparticles. Atomic Force Microscopy imaging with spectral processing was used to compare the wrinkle morphology for each case investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface coating for prevention of metallic seed migration in tissues

Purpose: In radiotherapy, metallic implants often detach from their deposited sites and migrate to other locations. This undesirable migration could cause inadequate dose coverage for permanent brachytherapy and difficulties in image-guided radiation delivery for patients. To prevent migration of implanted seeds, the authors propose a potential strategy to use a biocompatible and tissue-adhesive material called polydopamine. Methods: In this study, nonradioactive dummy seeds that have the same geometry and composition as commercial I-125 seeds were coated in polydopamine. Using scanning electron microscopy and x-ray photoelectron spectroscopy, the surface of the polydopamine-coated and noncoated seeds was characterized. The detachment stress between the two types of seeds and the tissue was measured. The efficacy of polydopamine-coated seed was investigated through in vitro migration tests by tracing the seed location after tissue implantation and shaking for given times. The cytotoxicity of the polydopamine coating was also evaluated. Results: The results of the coating characterization have shown that polydopamine was successfully coated on the surface of the seeds. In the adhesion test, the polydopamine-coated seeds had 2.1-fold greater detachment stress than noncoated seeds. From the in vitro test, it was determined that the polydopamine-coated seed migrated shorter distances than the noncoated seed. This difference was increased with a greater length of time after implantation. Conclusions: The authors suggest that polydopamine coating is an effective technique to prevent migration of implanted seeds, especially for permanent prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-329: Dosimetric Impact of Implementing Metal Artifact Reduction Methods and Metal Energy Deposition Kernels for Photon Dose Calculations

Purpose: To investigate two strategies for reducing dose calculation errors near metal implants: use of CT metal artifact reduction methods and implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) method. Methods: Radiochromic film was used to measure the dose upstream and downstream of titanium and Cerrobend implants. To assess the dosimetric impact of metal artifact reduction methods, dose calculations were performed using baseline, uncorrected images and metal artifact reduction Methods: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI imaging with metal artifact reduction software applied (MARs).To assess the impact of metal kernels, titanium and silver kernels were implemented into a commercial collapsed cone C/S algorithm. Results: The CT artifact reduction methods were more successful for titanium than Cerrobend. Interestingly, for beams traversing the metal implant, we found that errors in the dimensions of the metal in the CT images were more important for dose calculation accuracy than reduction of imaging artifacts. The MARs algorithm caused a distortion in the shape of the titanium implant that substantially worsened the calculation accuracy. In comparison to water kernel dose calculations, metal kernels resulted in better modeling of the increased backscatter dose at the upstream interface but decreased accuracy directly downstream of the metal. We also found that the success of metal kernels was dependent on dose grid size, with smaller calculation voxels giving better accuracy. Conclusion: Our study yielded mixed results, with neither the metal artifact reduction methods nor the metal kernels being globally effective at improving dose calculation accuracy. However, some successes were observed. The MARs algorithm decreased errors downstream of Cerrobend by a factor of two, and metal kernels resulted in more accurate backscatter dose upstream of metals. Thus, these two strategies do have the potential to improve accuracy for patients with metal implants in certain scenarios. This work was supported by Public Health Service grants CA 180803 and CA 10953 awarded by the National Cancer Institute, United States of Health and Human Services, and in part by Mobius Medical Systems.

60 APPLIED LIFE SCIENCES↗

Structure and optical properties of ZnO with silver nanoparticles

Textured nanocrystalline ZnO thin films are synthesized by ion beam assisted deposition. According to X-ray diffraction data, the crystallite size is ∼25 nm. Thin (∼15 nm) ZnO layers containing Ag nanoparticles are formed in a thin surface region of the films by the implantation of Ag ions with an energy of 30 keV and a dose in the range (0.25–1) × 10{sup 17} ion/cm{sup 2}. The structure and optical properties of the layers are studied. Histograms of the size distribution of Ag nanoparticles are obtained. The average size of the Ag nanoparticles varies from 0.5 to 1.5–2 nm depending on the Ag-ion implantation dose. The optical transmittance of the samples in the visible and ultraviolet regions increases, as the implantation dose is increased. The spectra of the absorption coefficient of the implanted films are calculated in the context of the (absorbing film)/(transparent substrate) model. It is found that the main changes in the optical-density spectra occur in the region of ∼380 nm, in which the major contribution to absorption is made by Ag nanoparticles smaller than 0.75 nm in diameter. In this spectral region, absorption gradually decreases, as the Ag-ion irradiation dose is increased. This is attributed to an increase in the average size of the Ag nanoparticles. It is established that the broad surface-plasmon-resonance absorption bands typical of nanocomposite ZnO films with Ag nanoparticles synthesized by ion implantation are defined by the fact that the size of the nanoparticles formed does not exceed 1.5–2 nm.

36 MATERIALS SCIENCE↗

Material Science Smart Coatings

The contribution of electrostatic interactions to the free energy of binding between model protein and a ceramic implant surface in the aqueous solvent, considered in the framework of the nonlocal electrostatic model, is calculated as a function of the implant low-frequency dielectric constant. We show that the existence of a dynamically ordered (low-dielectric) interfacial solvent layer at the protein-solvent and ceramic-solvent interface markedly increases charging energy of the protein and ceramic implant, and consequently makes the electrostatic contribution to the protein-ceramic binding energy more favorable (attractive). Our analysis shows that the corresponding electrostatic energy between protein and oxide ceramics depends nonmonotonically on the dielectric constant of ceramic, ε C . Obtained results indicate that protein can attract electrostatically to the surface if ceramic material has a moderate ε C below or about 35 (in particularly ZrO 2 or Ta 2 O 5 ). This is in contrast to classical (local) consideration of the solvent, which demonstrates an unfavorable electrostatic interaction of protein with typical metal oxide ceramic materials (ε C >10). Thus, a solid implant coated by combining oxide ceramic with a reduced dielectric constant can be beneficial to strengthen the electrostatic binding of the protein-implant complex.

36 MATERIALS SCIENCE↗

Skeletal response to corticosteroid deficiency and excess in growing male rats

The study was designed to investigate bone histomorphometric changes induced by corticosteroid deficiency and supplementation at different dose levels in the rat skeleton. Male rats were adrenalectomized (ADX) or sham-operated and divided into six groups. At 2 days after surgery, sham-operated control rats (CON + PLA) and one group of ADX rats (ADX + PLA) were implanted subcutaneously (s.c.) with placebo pellets. ADX rats in the remaining four groups (ADX + C25, ADX + C50, ADX + C100, and ADX + C300) were implanted sc with corticosterone pellets designed to release 25, 50, 100, or 300 mg of the hormone over a 60 day period. Each ADX rat was also implanted sc with an aldosterone pellet (2.5 mg) similarly designed to release its contents over the same time period. All rats were killed at 3 weeks after implantation of pellets. Terminal blood samples were collected for serum biochemistry and the proximal tibial metaphyses (PTM), tibial diaphyses, and first lumbar vertebrae (LV) were processed undecalcified for quantitative bone histomorphometry. A dose-dependent increase in serum corticosterone concentration was observed in ADX rats implanted with hormone pellets. In comparison to CON + PLA rats, ADX + PLA rats had lower cancellous bone volume associated with a stimulation in longitudinal bone growth, an increase in mineral apposition rate, and a trend for increased osteoclast and osteoblast surfaces in PTM. In contrast, cancellous bone of ADX + C25 rats was preserved at nearly the CON + PLA level. However, the higher doses of corticosterone increased cancellous bone mass, but decreased longitudinal bone growth and all indices of bone resorption and formation in a dose-dependent manner in PTM. Similar cancellous bone changes were observed in the LV of corticosterone-treated rats, with the exception of a lack of an hormonal effect on cancellous bone mass. In the tibial diaphysis, corticosterone inhibited periosteal bone formation in a dose-dependent manner, but did not affect cortical bone mass. The results indicate that corticosteroid deficiency induces cancellous osteopenia, whereas supplementation with a near physiologic dose of the hormone prevents this bone loss in ADX rats. Furthermore, corticosteroid excess inhibits bone growth and bone turnover in a dose-dependent manner, but does not induce cancellous osteopenia in growing male rats.

Non-NASA Center↗

Mechanisms of alpha 1-adrenergic vascular desensitization in conscious dogs

To investigate the mechanisms of alpha 1-adrenergic vascular desensitization, osmotic minipumps containing either saline (n = 9) or amidephrine mesylate (AMD) (n = 9), a selective alpha 1-adrenergic receptor agonist, were implanted subcutaneously in dogs with chronically implanted arterial and right atrial pressure catheters and aortic flow probes. After chronic alpha 1-adrenergic receptor stimulation, significant physiological desensitization to acute AMD challenges was observed, i.e., pressor and vasoconstrictor responses to the alpha 1-adrenergic agonist were significantly depressed (p < 0.01) compared with responses in the same dogs studied in the conscious state before pump implantation. However, physiological desensitization to acute challenges of the neurotransmitter norepinephrine (NE) (0.1 micrograms/kg per minute) in the presence of beta-adrenergic receptor blockade was not observed for either mean arterial pressure (MAP) (30 +/- 7 versus 28 +/- 5 mm Hg) or total peripheral resistance (TPR) (29.8 +/- 4.9 versus 28.9 +/- 7.3 mm Hg/l per minute). In the presence of beta-adrenergic receptor plus ganglionic blockade after AMD pump implantation, physiological desensitization to NE was unmasked since the control responses to NE (0.1 micrograms/kg per minute) before the AMD pumps were now greater (p < 0.01) than after chronic AMD administration for both MAP (66 +/- 5 versus 32 +/- 2 mm Hg) and TPR (42.6 +/- 10.3 versus 23.9 +/- 4.4 mm Hg/l per minute). In the presence of beta-adrenergic receptor, ganglionic, plus NE-uptake blockade after AMD pump implantation, desensitization was even more apparent, since NE (0.1 micrograms/kg per minute) induced even greater differences in MAP (33 +/- 5 versus 109 +/- 6 mm Hg) and TPR (28.1 +/- 1.8 versus 111.8 +/- 14.7 mm Hg/l per minute). The maximal force of contraction induced by NE in the presence or absence of endothelium was significantly decreased (p < 0.05) in vitro in mesenteric artery rings from AMD pump dogs compared with saline control dogs. Furthermore, alpha 1-adrenergic receptor density, as determined by [3H]prazosin binding in membrane preparations from vessels in the mesentery, was decreased (8.2 +/- 1.0 versus 18.4 +/- 1.4 fmol/mg protein, p < 0.001) without any change in Kd in the AMD pump dogs compared with the saline pump dogs.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Development of AlGaN‐Based Deep‐Ultraviolet Avalanche Photodetectors—Toward Their Intrinsic Characteristics

Al 0.6 Ga 0.4 N deep‐UV p–i–n avalanche photodiodes (APDs) are demonstrated grown by metalorganic chemical vapor deposition (MOCVD) on a (0001) c‐plane aluminum nitride (AlN) bulk substrate and fabricated both with and without an ion implantation process for mesa‐edge electric‐field termination. Three design considerations are taken into account: the optical absorption of the AlN bulk substrate, the photosensitivity of the APD, and the breakdown electric field. The MOCVD growth conditions of the AlGaN APD layers are optimized. Then, a detailed description of the seven device fabrication steps of the APDs is provided, which includes nitrogen ion implantation. The APDs fabricated by the ion implant process exhibit a dark‐current density under low reverse bias ≈1 × 10 −9 A cm −2 . This is one order of magnitude lower than the APD fabricated without ion implantation from the same wafer. The breakdown voltage of the APD is ≈−140 V. The calculated optical gain of the ion‐implanted APD beyond avalanche breakdown is ≈5.2 × 10 5 (current limited) and the device has an average zero‐bias photoresponse of ≈68 mA W −1 at a wavelength of 250 nm.

Jeong, Hoon [Department of Electronic Engineering ↗

Uterine Artery Embolization Combined with Local Methotrexate and Systemic Methotrexate for Treatment of Cesarean Scar Pregnancy with Different Ultrasonographic Pattern

Purpose: This study was designed to compare the effectiveness of systemic methotrexate (MTX) with uterine artery embolization (UAE) combined with local MTX for the treatment of cesarean scar pregnancy (CSP) with different ultrasonographic pattern, and to indicate the preferable therapy in CSP patients. Methods: The results of 21 CSP cases were reviewed. All subjects were initially administrated with systemic MTX (50 mg/m{sup 2} body surface area). UAE combined with local MTX was added to the patients who had failed systemic MTX. The transvaginal ultrasonography data were retrospectively assessed, and two different ultrasonographic patterns were found: surface implantation and deep implantation of amniotic sac. The management and its effectiveness for patients with the two ultrasonographic patterns were studied retrospectively. Ultrasound scan and serum {beta}-hCG were monitored during follow-up. Data were analyzed with the Student's t test. Results: Nine patients were successfully treated with systemic MTX. The remaining 12 cases were successfully treated with additional UAE combined with local MTX. According to the classification by Vial et al. of CSP on ultrasonography, most surface implanted CSPs (8/11, 72.7%) could be successfully treated with systemic MTX, whereas most deeply implanted CSPs (9/10, 90%) had failed systemic MTX but still could be successfully treated with additional UAE combined with local MTX. All patients recovered without severe side effects. Most patients with a future desire for reproduction achieved subsequent pregnancy. Conclusions: For CSP patients suitable for nonsurgical treatment, UAE combined with local MTX would be the superior option compared with systemic MTX in the cases with deep implantation of amniotic sac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular and histological study on the effects of non-thermal irreversible electroporation on the liver

Highlights: • Hepatocytes completely disintegrate within 6 h after NTIRE, TUNEL stain is seen as a diffuse stain throughout the treated volume 6 h after NTIRE. • The extracellular matrix in the treated volume is intact after NTIRE. • Hepatocytes, normal and bi-nucleated, are seen in the treated volume, 24 h after NTIRE. • Cleaved caspase-3 is actually downregulated after NTIRE. • Cleaved caspase-1, gasdermin D, RIP3 and MLKL are upregulated 6 h, and downregulated 24 h after NTIRE. Non-thermal irreversible electroporation (NTIRE) is a biophysical phenomenon in which certain electric fields delivered across the cell membrane in tissue, cause cell death, without affecting the extracellular matrix. “Minimally invasive regenerative surgery” is a new medical modality for treatment of end-stage organ or tissue failure in which exogenous cells are implanted in a decellularized niche in tissue, formed by the delivery of NTIRE electric fields across a targeted volume of tissue. We anticipate that the success of the procedure will depend on the time of implantation relative to the application of NTIRE. This study was performed to elucidate the histological and molecular events that occur within 24 h after NTIRE, in the context of optimal criteria for the time of implantation. To this end, we examined the histology of NTIRE treated rat liver with H&E, Masson trichrome and TUNEL staining. Western blot was used to examine pro and cleaved caspase-3 (marker for apoptosis), pro and cleaved caspase-1 and gasdermin D (markers for pyroptosis), and RIP3 and MLKL (markers for necroptosis). The key findings are that, complete hepatocytes disintegration within an intact extracellular matrix is seen at 6 h and, new hepatocytes are seen in the treated region at 24 h, after NTIRE. There is no evidence of apoptotic cell death from NTIRE, contrary to commonly made claims in the NTIRE literature. However, molecular pathways of pyroptosis and necroptosis, programed necrosis associated with inflammation, are activated at 6 h after NTIRE and are not evident at 24 h after NTIRE. These are fundamental new findings of basic value to the field of NTIRE in all its applications. Taken together the results suggest the hypothesis that an optimal time for implantation is about 24 h after NTIRE. Future studies in which exogenous cells are implanted at different times after NTIRE are required to examine this hypothesis.

60 APPLIED LIFE SCIENCES↗

Comparison of Kilovoltage Cone-Beam Computed Tomography With Megavoltage Projection Pairs for Paraspinal Radiosurgery Patient Alignment and Position Verification

Purpose: Implanted gold markers and megavoltage (MV) portal imaging are commonly used for setup verification of paraspinal tumors treated with high-dose, single-fraction radiotherapy. We investigated whether the use of kilovoltage cone-beam computed tomography (CBCT) imaging eliminates the need for marker implantation. Methods and Materials: Patients with paraspinal disease who were eligible for single-fraction stereotactic body radiotherapy were accrued to an institutional review board-approved protocol. Each of 16 patients underwent implantation of fiducial markers near the target. The markers were visible on the MV images. Three MV image pairs were acquired for each patient (initial, verification, and final) and were registered to the reference images. Every MV pair was complemented by a CBCT scan. CBCT image registration was performed automatically by maximizing the mutual information using a region of interest that excluded the markers. The corrections, as determined from the MV images, were compared with these from CBCT and were used for actual patient setup. Results: The mean and standard deviation of the absolute values of the differences between the CBCT and MV corrections were 1.0 {+-} 0.7, 1.0 {+-} 0.6, and 1.0 {+-} 0.8 mm for the left-right, anteroposterior, and superoinferior directions, respectively. The absolute differences between the corresponding pre- and post-treatment kilovoltage CBCT image registration were 0.6 {+-} 0.5, 0.6 {+-} 0.5, and 1.0 {+-} 0.8 mm. Conclusion: The setup corrections found using CBCT without the use of implanted markers were consistent with the marker registration on MV projections. CBCT has additional advantages, including better positioning precision and robust automatic three-dimensional registration, as well as eliminating the need for invasive marker implantation. We have adopted CBCT for the setup of all single-fraction paraspinal patients. Our data have also demonstrated that target displacements during treatment are insignificant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

β-particle energy-summing correction for β-delayed proton emission measurements

One common approach to studying β-delayed proton emission is to measure the energy of the emitted proton and corresponding nuclear recoil in a double-sided silicon-strip detector (DSSD) after implanting the β-delayed proton-emitting (βp) nucleus. However, in order to extract the proton-decay energy, the measured energy must be corrected for the additional energy implanted in the DSSD by the β-particle emitted from the βp nucleus, an effect referred to here as β-summing. Here, we present an approach to determine an accurate correction for β-summing. Our method relies on the determination of the mean implantation depth of the βp nucleus within the DSSD by analyzing the shape of the total (proton + recoil + β) decay energy distribution shape. We validate this approach with other mean implantation depth measurement techniques that take advantage of energy deposition within DSSDs upstream and downstream of the implantation DSSD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the substrate orientation on the formation of He-plates in Si

The effect of the crystalline orientation on the implantation-induced strain/stress and on the formation of He-plates was studied by combining high-resolution X-ray scattering and transmission electron microscopy. The highest strains are obtained in (001)-oriented implanted substrates regardless of the fluence and of the channeling effects. The anisotropic properties of the silicon that generate an anisotropic elastic response of the substrate were taken into account to explain these different values of strain. Upon specific thermal annealing, it is shown that the formation of He-plates occurs only in the (001) habit planes regardless of the orientation of the substrates, non-tilted and tilted (001)-, (110)-, and (111)-substrates. Moreover, the distribution of He-plates in the (001) variants was found to be strongly dependent on the angle of the habit plane with the surface and on the intensity of the implantation-induced strain/stress. The implantation-induced stress thus favors the formation of He-plates in specific planes (of low angle with the surface) forming different defect configurations. The nucleation and growth of He-plates are thus discussed with regard to the implantation-induced stress.

36 MATERIALS SCIENCE↗

Local traps as nanoscale reaction-diffusion probes: B clustering in c-Si

A series of B implantation experiments into initially amorphized and not fully recrystallized Si, i.e., into an existing a/c-Si bi-layer material, have been conducted. We varied B dose, energy, and temperature during implantation process itself. Significant B migration has been observed within c-Si part near the a/c-interface and near the end-of-range region before any activation annealing. We propose a general concept of local trapping sites as experimental probes of nanoscale reaction-diffusion processes. Here, the a/c-Si interface acts as a trap, and the process itself is explored as the migration and clustering of mobile BI point defects in nearby c-Si during implantation at temperatures from 77 to 573 K. We find that at room temperature—even at B concentrations as high as 1.6 atomic %, the key B-B pairing step requires diffusion lengths of several nm owing to a small, ∼0.1 eV, pairing energy barrier. Thus, in nanostructures doped by ion implantation, the implant distribution can be strongly influenced by thermal migration to nearby impurities, defects, and interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗