Rough-Wall Turbulent Heat Transfer Experiments in Hypersonic Free Flight

Experiments are being conducted in the NASA Ames Hypervelocity Free Flight Aerodynamic Facility to quantify the effects on turbulent convective heat transfer of surface roughness representative of a new class of 3D woven thermal protection system mRough-wall turbulent heat transfer measurements were obtained on ballistic-range models in hypersonic flight in the NASA Ames Hypervelocity Free Flight Aerodynamic Facility. Each model had three different surface textures on segments of the conic frustum: smooth wall, sand roughness, and a pattern roughness, thus providing smooth-wall and sand-roughness reference data for each test. The pattern roughness was representative of a woven thermal protection system material developed by NASA's Heatshield for Extreme Entry Environment Technology project. The tests were conducted at launch speeds of 3.2 km/s in air at 0.15 atm. Roughness Reynolds numbers, k+, ranged for 12 to 70 for the sand roughness, and as high as 200 for the pattern roughness. Boundary-layer parameters required for calculating k+ were evaluated using computational fluid dynamics simulations. The effects of pattern roughness are generally characterized by an equivalent sand roughness determined with a correlation developed from experimental data obtained on specifically-designed roughness patterns that do not necessarily resemble real TPS materials. Two sand roughness correlations were examined: Dirling and van Rij, et al. Both gave good agreement with the measured heat-flux augmentation for the two larger pattern roughness heights tested, but not for the smallest height tested. It has yet to be determined whether this difference is due to limitations in the experimental approach, or due to limits in the correlations used. Future experiments are planned that will include roughness patterns more like those used in developing the equivalent sand roughness correlations.aterials being developed by NASA's Heatshield for Extreme Entry Environment Technology (HEEET) project. Data were simultaneously obtained on sand-grain roughened surfaces and smooth surfaces, which can be compared with previously obtained data. Results are presented in this extended abstract for one roughness pattern. The full paper will include results from three roughness patterns representing virgin HEEET, nominal turbulent ablated HEEET, and twice the roughness of nominal turbulent ablated HEEET. Results will be used to compare with commonly used equivalent sand grain roughness correlations.

pattern roughness↗

An experimental summary of plasma arc exposures of space shuttle high-temperature reusable surface insulation tile array with a single missing tile (conducted at the Ames Research Center)

A space shuttle high temperature reusable surface insulation (HRSI) tile array with a single missing or lost tile was exposed to a hot gas simulated reentry environment to investigate the heating conditions in and around the vicinity of the missing HRSI tile. Heat flux and pressure data for the lost tile condition were obtained by the use of a water cooled lost tile calibration model. The maximum aluminum substrate temperature obtained during the simulated reentry was 128 C (263 F). The lost tile calibration data indicated a maximum heat flux in the lost tile cavity region of 63 percent of the upstream reference value. This test was conducted at the Ames Research Center in the 20 MW semielliptical thermal protection system (TPS) pilot plasma arc test facility.

Galanter, S. A.↗

NUMERICAL VERIFICATION OF THE RELAP-7 CORE CHANNEL SINGLE-PHASE MODEL

The RELAP-7 code is the next generation of nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). All the physics in RELAP-7 are fully coupled and the errors resulted from the traditional operator-splitting approach are eliminated. By using 2nd order methods in both time and space and eliminating operator-splitting errors, the numerical error of RELAP-7 can be minimized. Numerical verification is the process to verify the orders of numerical methods. It is an important part of modern verification and validation process. The core channel component in RELAP-7 is designed to simulate coolant flow as well as the conjugated heat transfer between coolant flow and the fuel rod. A special treatment at fuel centerline to avoid numerical singularity for the cylindrical heat conduction in the continuous finite element mesh is discussed. One steady state test case and one fast power up transient test case are utilized for the verification of the core channel model with single-phase flow. Analytical solution for the fuel pin temperature and figures of merit such as peak clad temperature and peak fuel temperature are used to define numerical errors. These cases prove that the mass and energy are well conserved and 2nd order convergence rates for both time and space are achieved in the core channel model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Validation of Resistance-Capacitance Model for Phase Change Material Embedded in Porous Media

A simple and effective way to enhance PCM thermal conductivity is by embedding porous materials with high thermal conductivities. In this work, CFD was used to evaluate the melting of PCM embedded in metal foam supplied with constant heat flux. Good agreement between experimental and numerical results has been found with a mean PCM local temperature deviation of 1.62K and 2.97K in two locations. The CFD simulation time was 56 hours for 6.5 hours of flow time. A computationally efficient resistance capacitance-based model (RCM) was developed to improve simulation speed. The proposed RCM exhibited mean local temperature deviations of 1.86K and 2.96K when compared against the experimental data for two thermocouple positions, however, it was approximately 2.5x10 5 times faster than CFD. The charging time deviation was less than 1% compared to CFD, and no significant change in thermal energy stored was observed since the temperature differences were small enough to result in insignificant sensible heat deviation. A simulation cost-effectiveness index (CEI) considering accuracy and computational affordability was introduced; the CEI of the RCM solver is 10 3 times better compared to CFD for the prediction of local PCM temperature.

25 ENERGY STORAGE↗

AERACEPT (AErosol Rapid Analysis Combined Entry Probe/sonde Technology) for the Nephele Venus Cloud Mission Concept

Nephele is a small atmospheric probe mission concept to determine whether the Venus clouds contain organic matter. Nephele complements larger missions that seek to conduct Venus atmospheric analyses, such as DAVINCI, Venera-D, and the Morning Star missions, by directly sampling and analyzing cloud and haze particles. AERACEPT is an aerosol sampling technology designed to minimize the mass, volume, and complexity required for in situ planetary atmosphere characterization. A single aeroshell functions as a combined entry vehicle, descent probe, and instrumented sonde, combining recent advances in thermal protection materials with heritage technology from planetary and airborne science. The velocity of descent drives aerosol through inlets embedded in the aeroshell’s thermal protection material; inertial separation isolates the particles from the gas stream; and the particle capture surface doubles as the analysis substrate. This method can work without heat shield separation, descent control, or active sample handling; these advantages trade against a smaller sample volume, higher risk of sample heating, and shorter time for analysis and data return. AERACEPT further benefits from modeling of the internal and external flow to understand the particle capture efficiency and bias for size and concentration distributions. AERACEPT is well suited for a Venus mission such as Nephele, where a passive descent trajectory is both subsonic over the altitudes of interest and provides sufficient velocity and pressure differential for the particle sizes of interest. A thermal and flow toolchain developed in-house (Traj→ DPLR→ PATO→ openFOAM) was used to model an 80-cm aeroshell with science operations 63–39 km. These models indicate that AERACEPT will provide ~24 µL accumulated sample of particles ≥ 0.2 µm, substantially above the 2 µL threshold requirement. The worst-case particle heating will be ~14 K above ambient, for the smallest particles at the lowest altitude; most particles will experience ≤ 1 K rise, at which almost all analytes of interest will be unaffected. Plasma jet testing of a small-scale aeroshell-material inlet was recently conducted to validate the thermal model parameters; wind tunnel testing to validate the flow model parameters is underway.

AERACEPT↗

The local heat transfer mathematical model between vibrated fluidized beds and horizontal tubes

A dimensionless mathematical model is proposed to predict the local heat transfer coefficients between vibrated fluidized beds and immersed horizontal tubes, and the effects of the thickness of gas film and the contact time of particle packets are well considered. Experiments using the glass beads (the average diameter bar d{sub p}=1.83mm) were conducted in a two-dimensional vibrated fluidized bed (240 mm x 80 mm). The local heat transfer law between vibrated fluidized bed and horizontal tube surface has been investigated. The results show that the values of theoretical prediction are in good agreement with experimental data, so the model is able to predict the local heat transfer coefficients between vibrated fluidized beds and immersed horizontal tubes reasonably well, and the error is in range of {+-}15%. The results can provide references for future designing and researching on the vibrated fluidized beds with immersed horizontal tubes. (author)

42 ENGINEERING↗

Thermal instability in post-flare plasmas

The cooling of post-flare plasmas is discussed and the formation of loop prominences is explained as due to a thermal instability. A one-dimensional model was developed for active loop prominences. Only the motion and heat fluxes parallel to the existing magnetic fields are considered. The relevant size scales and time scales are such that single-fluid MHD equations are valid. The effects of gravity, the geometry of the field and conduction losses to the chromosphere are included. A computer code was constructed to solve the model equations. Basically, the system is treated as an initial value problem (with certain boundary conditions at the chromosphere-corona transition region), and a two-step time differencing scheme is used.

Antiochos, S. K.↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Thermal analysis of heat storage canisters for a solar dynamic, space power system

A thermal analysis was performed of a thermal energy storage canister of a type suggested for use in a solar receiver for an orbiting Brayton cycle power system. Energy storage for the eclipse portion of the cycle is provided by the latent heat of a eutectic mixture of LiF and CaF2 contained in the canister. The chief motivation for the study is the prediction of vapor void effects on temperature profiles and the identification of possible differences between ground test data and projected behavior in microgravity. The first phase of this study is based on a two-dimensional, cylindrical coordinates model using an interim procedure for describing void behavor in 1-g and microgravity. The thermal analysis includes the effects of solidification front behavior, conduction in liquid/solid salt and canister materials, void growth and shrinkage, radiant heat transfer across the void, and convection in the melt due to Marangoni-induced flow and, in 1-g, flow due to density gradients. A number of significant differences between 1-g and o-g behavior were found. This resulted from differences in void location relative to the maximum heat flux and a significantly smaller effective conductance in 0-g due to the absence of gravity-induced convection.

Wichner, R. P.↗

Reducing the Cost of Thermal Energy Storage for Parabolic Trough Solar Power Plants

Thermal energy storage systems using phase change materials were evaluated for trough systems that use oil, steam, and high temperature salts as heat transfer fluids. A variety of eutectic salts and metal alloys were considered as phase change materials in a cascaded arrangement. Literature values of specific heat, latent heat, density, and other thermophysical properties were used in initial analyses. Testing laboratories were contracted to measure properties for candidate materials for comparison to the literature and for updating the models. A TRNSYS model from Phase 1 was further developed for optimizing the system, including a novel control algorithm. A concept for increasing the bulk thermal conductivity of the phase change system was developed using expanded metal sheets. Outside companies were contracted to design and cost systems using platecoil heat exchangers immersed in the phase change material. Laboratory evaluations of the one-dimensional and three-dimensional behavior of expanded metal sheets in a low conductivity medium were used to optimize the amount of thermal conductivity enhancement. The thermal energy storage systems were compared to baseline conventional systems. The best phase change system found in this project, which was for the high temperature plant, had a projected cost of $25.2 per kWhth, The best system also had a cost that was similar to the base case, a direct two-tank molten salt system.

14 SOLAR ENERGY↗

Progress Towards Modeling a Rapid Cycle Adsorption Pump for CO2 Compression

A Rapid Cycle Adsorption Pump (RCAP) is a competitive technology for capturing and pressuring CO2 within a Martian In-Situ Resource Utilization (ISRU) system. In an ISRU plant, CO2 from the Martian atmosphere at ~0.69-0.925kPa must first be pressured to ~101-500kPa to produce O2 and/or CH4. A RCAP pressurizes CO2 by imposing fast temperature swings on an adsorbent bed low pressure CO2 is adsorbed onto the cooled bed, and higher pressure CO2 is desorbed from the heated bed. To aid the design of a RCAP for NASA's Advanced Exploration Systems (AES) ISRU project, a finite difference thermal model of a single stack RCAP was developed in Thermal Desktop. The stack consists of one gas passage sandwiched between two sorbent beds and two cold plates (for heating/cooling each bed). The model implements adsorption/desorption physics via a linear driving force approximation in order to predict both temperature and pressure swings in the pump. The modeling approach is presented along with a discussion of its results and the current design. The model was also used to trade cooling speed when constructing the RCAP with 3D printed high thermal conductivity copper (GRCop-84) verses 3D printed aluminum (AlSi10mg). A wide assembly was modeled to predict the performance of multiple stacks in parallel. Major performance drivers were identified to be 1) the contact heat transfer to the sorbent bed, and 2) the pump's thermal mass.

Modeling↗

Analysis of heat transfer in a simulated wing-elevon cove in hypersonic flow

A simplified analytical model of leakage into a wing-elevon cove under high speed external flow conditions is presented. The model accounts for convection from the high temperature gas stream leaking into the cove, radiation exchanges between walls and with the environment, and axial conduction within the channel walls. Comparisons are made of predicted and measured wall temperatures of an experimental wing-elevon-cove model that was tested in a hypersonic wind tunnel. Analytically determined Nusselt numbers for laminar flow entrance conditions are compared with those calculated from experimentally measured gas temperatures, wall temperatures and wall heating rates. Although reasonable agreement appears to be indicated, testing times much larger than those of the present test program (5 seconds) would be desirable in evaluating the reliability and accuracy of the simplified model.

Keshock, E. G.↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Determining the extent of potential fugitive fluid migration from geologic carbon storage in hydrocarbon-bearing reservoirs: Insights from one-dimensional numerical modeling

Numerical modeling of Geologic Carbon Sequestration in permeable reservoirs initially containing hydrocarbons is conducted using the multi-phase, multi-component thermohydrologic simulator TOGA (TOUGH Oil, Gas, Aqueous; TOUGH stands for Transport Of Unsaturated Groundwater and Heat), to determine how phase and composition of the original fluids influence the extent of the zone where upward fugitive fluid migration could potentially occur, denoted R f . The area within R f comprises regions of substantially elevated pressure and free-phase CO 2 saturation, where a breach in reservoir sealing capacity would lead to upward fugitive fluid migration. The model examines the conditions within the storage reservoir that could lead to fugitive flow, but does not model the fugitive flow itself. A one-dimensional radial model of the storage reservoir is used, and three initial phase conditions are considered: single-phase aqueous, two-phase gas-aqueous, and three-phase oil-gas-aqueous. Components that may be present are H 2 O, CO 2 , CH 4 , C 4 H 10 , and C 10 H 22 . The most important factors controlling Rf are (1) the initial gas-phase saturation within the reservoir, and (2) the lateral extent of multi-phase initial conditions, particularly CO 2 . The composition of liquid and gas phases has a secondary effect. The impact of reservoir depth, thickness, injection rate, and hydrologic properties are also briefly examined, with thickness (or equivalently injection rate) having the biggest effect. These results can help to understand important trends in potential response of CO 2 -EOR fields being considered for dedicated CO 2 storage.

CO₂ plume migration↗

Thermal Modeling of a Dual-Stage Sodium Thermal-Electrochemical Converter (Na-TEC)

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity through the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (550 K – 950 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management through a reduction of parasitic losses. These losses are comprised of (i) the heat input that does not participate in power production but simply bypasses the thermo-electrochemical process and is transferred to the condenser, and (ii) heat that is lost from the device directly to the surroundings due to poor insulation. Heat loss to the surroundings occurs from a lower average hot-side temperature given that a fraction of the power conversion occurs at an intermediate stage. Also, the condenser now directly interacts with the lower temperature of the intermediate stage, thereby reducing radiation loss. A simplified geometry is developed for this device to help guide its design from a heat transfer perspective. All thermal contact and boundary conditions are discussed, including the evaporation and condensation of sodium vapor, thermal leakage through the housing, and the thermal contact between the beta”-alumina and the housing. A ray tracing method assuming gray, diffuse surfaces is used to account for the internal radiation heat transfer within the device. Liquid sodium flows in a capillary wick between the condenser and the evaporator with Pe << 1, so only conduction heat transfer is considered within this liquid return path. For simplicity, natural convection between the sodium vapor and the device housing is neglected. A numerical linear resistance model (<5% error when compared to a finite element model) is used to determine the expected conversion temperatures of each stage for a range of candidate materials. Furthermore, a numerical model (<2% error) is developed to find the factor of increase in the thermal resistance for several designs of corrugated features for the device housing. By using an iterative scheme, efficiency vs. power curves are created for a number of material and size combinations. Finally, the fundamental tradeoff between the power and efficiency is explored in conjunction with the total system size.

14 SOLAR ENERGY↗

Water Collection, Recovery, and Bag Containment Analysis of Trash Models of the Trash Compaction and Processing System (TCPS)

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. One of the resources desired to be recovered is water from the trash. The HMC Gen 3 has undergone several tests of different trash models and cases in which a containment bag is used or not. This paper will analyze the water collected and recovered from these tests and analyze the effect of specific trash containment bags.

Janine Criselda Young↗

An assessment of coupling algorithms for nuclear reactor core physics simulations

This paper evaluates the performance of multiphysics coupling algorithms applied to a light water nuclear reactor core simulation. The simulation couples the k-eigenvalue form of the neutron transport equation with heat conduction and subchannel flow equations. We compare Picard iteration (block Gauss–Seidel) to Anderson acceleration and multiple variants of preconditioned Jacobian-free Newton–Krylov (JFNK). The performance of the methods are evaluated over a range of energy group structures and core power levels. A novel physics-based approximation to a Jacobian-vector product has been developed to mitigate the impact of expensive on-line cross section processing steps. Numerical simulations demonstrating the efficiency of JFNK and Anderson acceleration relative to standard Picard iteration are performed on a 3D model of a nuclear fuel assembly. Both criticality (k-eigenvalue) and critical boron search problems are considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Report for Project titled High Thermal Conductivity Polymer Composites for Low-Cost Heat Exchangers

Heat exchangers (HXs) are critical components in a wide range of heat transfer applications, from HVAC (Heating Ventilation and Cooling) to automobiles to manufacturing plants. They require materials capable of transferring heat at high rates while also minimizing thermal expansion over the usage temperature range. Conventionally, metals are used for applications where effective and efficient heat exchange is required, since many metals exhibit thermal conductivity over 100 W/m K. While metal HXs are constantly being improved, they still have some inherent drawbacks due to their metal construction, in particular corrosion. Polymeric material can offer solution to such durability issues and allow designs that cannot be afforded by metal construction either due to complexity or cost. A major drawback of polymeric material is their low thermal conductivity (0.1-0.5? W/mK) that would lead to large system size. Recent improvements in the area of filled polymers have highlighted the possibility to greatly improve the thermal conductivity of polymeric materials while retaining their inherent manufacturing advantage, and have been applied to heat sink applications. Therefore, the objective of this project was to develop a robust review of materials for the manufacturing of industrial and commercial non-metallic heat exchangers. This review consisted of material identification, literature evaluation, as well as empirical and model characterization, resulting in a database of relevant material properties and characteristics to provide guidance for future heat exchanger development.