Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fusion Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Fusion proton diagnostic for the C-2 field reversed configuration

Measurements of the flux of fusion products from high temperature plasmas provide valuable insights into the ion energy distribution, as the fusion reaction rate is a very sensitive function of ion energy. In C-2, where field reversed configuration plasmas are formed by the collision of two compact toroids and partially sustained by high power neutral beam injection [M. Binderbauer et al., Phys. Rev. Lett. 105, 045003 (2010); M. Tuszewski et al., Phys. Rev. Lett. 108, 255008 (2012)], measurements of DD fusion neutron flux are used to diagnose ion temperature and study fast ion confinement and dynamics. In this paper, we will describe the development of a new 3 MeV proton detector that will complement existing neutron detectors. The detector is a large area (50 cm{sup 2}), partially depleted, ion implanted silicon diode operated in a pulse counting regime. While the scintillator-based neutron detectors allow for high time resolution measurements (∼100 kHz), they have no spatial or energy resolution. The proton detector will provide 10 cm spatial resolution, allowing us to determine if the axial distribution of fast ions is consistent with classical fast ion theory or whether anomalous scattering mechanisms are active. We will describe in detail the diagnostic design and present initial data from a neutral beam test chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an electrostatic dust removal system with potential application in next-step fusion devices

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass, and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 mm{sup 3} volume of carbon and tungsten particles were moved in under 5 s. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon and the change in particle distribution over short timescales (<1 s).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary consideration of CFETR ITER-like case diagnostic system

Chinese Fusion Engineering Test Reactor (CFETR) is a new superconducting tokamak device being designed in China, which aims at bridging the gap between ITER and DEMO, where DEMO is a tokamak demonstration fusion reactor. Two diagnostic cases, ITER-like case and towards DEMO case, have been considered for CFETR early and later operating phases, respectively. In this paper, some preliminary consideration of ITER-like case will be presented. Based on ITER diagnostic system, three versions of increased complexity and coverage of the ITER-like case diagnostic system have been developed with different goals and functions. Version A aims only machine protection and basic control. Both of version B and version C are mainly for machine protection, basic and advanced control, but version C has an increased level of redundancy necessary for improved measurements capability. The performance of these versions and needed R&D work are outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian tomography and integrated data analysis in fusion diagnostics

In this article, a Bayesian tomography method using non-stationary Gaussian process for a prior has been introduced. The Bayesian formalism allows quantities which bear uncertainty to be expressed in the probabilistic form so that the uncertainty of a final solution can be fully resolved from the confidence interval of a posterior probability. Moreover, a consistency check of that solution can be performed by checking whether the misfits between predicted and measured data are reasonably within an assumed data error. In particular, the accuracy of reconstructions is significantly improved by using the non-stationary Gaussian process that can adapt to the varying smoothness of emission distribution. The implementation of this method to a soft X-ray diagnostics on HL-2A has been used to explore relevant physics in equilibrium and MHD instability modes. This project is carried out within a large size inference framework, aiming at an integrated analysis of heterogeneous diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping the body’s battle with Ebola and Zika

The viruses that cause Ebola and Zika, daunting diseases that inspire concern at every outbreak, share a strong similarity in how they first infiltrate a host’s cells. Through the computer modeling capabilities of Los Alamos National Laboratory, the molecular calisthenics involved in invading a cell are visually documented, an essential step toward vaccine and therapeutic medicine development. “The two very different viruses both use a surface protein to initiate a process called ‘membrane fusion,’ which allows the viral entry into the host cell,” said Chang-Shung Tung, the leading and corresponding author of the recent work in the journal Biomolecules. “Before the membrane fusion started, these two proteins went through large conformational changes that was not fully understood, as the proteins would take on the physical shape that would allow them to fuse with the cell and begin the infection. In this work, we modeled the structures of the two proteins in the fusion-initiation state. Then we used the structures to explain how four different antibodies in our bodies can fight the infection and block the viral entry, based on how they bind to these two proteins,” Tung said. The aim of the team’s work was to understand the specific structure-function relationship of the Ebola glycoprotein (EBOV GP) and Zika envelope (ZIKA E) proteins, the ones that are instrumental in the fusion with the host cell. “This computer modeling approach allowed us to generate atomic-level models of EBOV GP and ZIKV E proteins in the fusion state for the first time,” said Anna Lappala, a postdoctoral fellow at the Center for Nonlinear Studies and the Theoretical Biology & Biophysics Group at Los Alamos. “These models, together with the knowledge of the envelope proteins in the pre-fusion state, allowed us to study the function of neutralizing antibodies as they bind to the viral envelope proteins.” Read the published scientific paper here: http://www.mdpi.com/2218-273X/8/2/25/pdf

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of the Li beam probe with a beam profile monitor on JET

The lithium beam probe (LBP) is widely used for measurements of the electron density in the edge plasma of magnetically confined fusion experiments. The quality of LBP data strongly depends on the stability and profile shape of the beam. The main beam parameters are as follows: beam energy, beam intensity, beam profile, beam divergence, and the neutralization efficiency. For improved monitoring of the beam parameters, a beam profile monitor (BPM) from the National Electrostatics Corporation (NEC) has been installed in the Li beam line at JET. In the NEC BPM, a single grounded wire formed into a 45 deg. segment of a helix is rotated by a motor about the axis of the helix. During each full revolution, the wire sweeps twice across the beam to give X and Y profiles. In this paper, we will describe the properties of the JET Li beam as measured with the BPM and demonstrate that it facilitates rapid optimization of the gun performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing neutron imaging line of sight locations for maximizing sampling of the cold fuel density in inertial confinement fusion implosions at the National Ignition Facility

We report that neutron imaging provides a ready measurement of the shape of the “hot spot” core of an inertial confinement fusion implosion. The 14-MeV neutrons emitted by deuterium-tritium reactions are imaged at the National Ignition Facility using a pinhole array onto a scintillator, and the images are recorded on a camera. By changing the gate time of the camera, lower energy neutrons, downscattered by the cold fuel surrounding the hot spot, are recorded. The cold fuel density can be reconstructed using the two images. The kinematics of the scattering coupled with the scattering cross sections restrict the angular extent of the cold fuel sampled, with the backside of the implosion not being sampled at all. This work demonstrates the limited region of the cold fuel measured by the current line of sight (40%). Finally, at completion of the three planned lines of sight, 79% of the cold fuel will be sampled.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A two photon absorption laser induced fluorescence diagnostic for fusion plasmas

The quality of plasma produced in a magnetic confinement fusion device is influenced to a large extent by the neutral gas surrounding the plasma. The plasma is fueled by the ionization of neutrals, and charge exchange interactions between edge neutrals and plasma ions are a sink of energy and momentum. Here we describe a diagnostic capable of measuring the spatial distribution of neutral gas in a magnetically confined fusion plasma. A high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup -1}) laser is injected into a hydrogen plasma to excite the Lyman {beta} transition via the simultaneous absorption of two 205 nm photons. The absorption rate, determined by measurement of subsequent Balmer {alpha} emission, is proportional to the number of particles with a given velocity. Calibration is performed in situ by filling the chamber to a known pressure of neutral krypton and exciting a transition close in wavelength to that used in hydrogen. We present details of the calibration procedure, including a technique for identifying saturation broadening, measurements of the neutral density profile in a hydrogen helicon plasma, and discuss the application of the diagnostic to plasmas in the DIII-D tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of Spatter on Porosity, Microstructure, and Corrosion of Additively Manufactured Stainless Steel Printed Using Different Island Size

Specimens of 316 L stainless steel were printed using laser powder bed fusion (LPBF), a popular metal additive manufacturing (AM) technique, with varying island sizes. Not many researchers have considered the impact of spatter while optimizing LPBF printing parameters. In this research, the influence of spatter was considered while also investigating the effect of varied island size on the microstructure, surface roughness, microhardness, and corrosion resistance of LPBF-316 L. No correlation was observed between surface roughness or microhardness and minor variations in island size. However, a correlation was drawn between varied island sizes and porosity in LPBF-316 L. The specimens associated with larger island sizes showed significantly enhanced corrosion resistance due to fewer manufacturing defects and reduced porosity, attributed to the minimal influence of the spatter. Based on analysis, the LPBF parameters were revised, which lead to superior corrosion resistance of LPBF-316 L, attributed to high density and reduced porosity.

36 MATERIALS SCIENCE↗

Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak

The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Freon-Filled Bubble Chamber for Neutron Detection in Inertial Confinement Fusion Experiments

Neutron imaging is one of the main methods used in inertial confinement fusion experiments to measure the core symmetry of target implosions. Previous studies have shown that bubble chambers have the potential to obtain higher resolution images of the targets for a shorter source-to-target distance than typical scintillator arrays. A bubble chamber for neutron imaging with Freon 115 as the active medium was designed and built for the OMEGA laser system. Bubbles resulting from spontaneous nucleation were recorded. Bubbles resulting from neutron–Freon interactions were observed at neutron yields of 1013 emitted from deuterium–tritium target implosions on OMEGA. The measured column bubble density was too low for neutron imaging on OMEGA but agreed with the model of bubble formation. The recorded data suggest that neutron bubble detectors are a promising technology for the higher neutron yields expected at National Ignition Facility.

Ghilea, M C↗

A new GEM based neutron diagnostic concept for high flux neutron beams

Fusion-fission hybrid reactors will need high flux neutron detectors to diagnose the deuterium-tritium fusion plasmas as well as the fission reactions. A candidate detection technique is the Gas Electron Multiplier (GEM). New GEM based detectors are being developed for application to a neutral deuterium beam test facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission due to interaction of the deterium beam with the deuterons implanted in the beam dump surface. This is done by placing a detector in close contact, right behind the dump. CNESM uses nGEM detectors, i.e. GEM detectors equipped with a cathode that also serves as neutron-proton converter foil. A small size prototype of nGEM detector has been built and is ready to be tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new nonlinear reconstruction method based on total variation regularization of neutron penumbral imaging

Neutron penumbral imaging is a significant diagnostic technique in laser-driven inertial confinement fusion experiment. It is very important to develop a new reconstruction method to improve the resolution of neutron penumbral imaging. A new nonlinear reconstruction method based on total variation (TV) regularization is proposed in this paper. A TV-norm is used as regularized term to construct a smoothing functional for penumbral image reconstruction in the new method, in this way, the problem of penumbral image reconstruction is transformed to the problem of a functional minimization. In addition, a fixed point iteration scheme is introduced to solve the problem of functional minimization. The numerical experimental results show that, compared to linear reconstruction method based on Wiener filter, the TV regularized nonlinear reconstruction method is beneficial to improve the quality of reconstructed image with better performance of noise smoothing and edge preserving. Meanwhile, it can also obtain the spatial resolution with 5 {mu}m which is higher than the Wiener method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing 3-D Asymmetries in Laser-Direct-Drive Implosions on OMEGA

Three-dimensional reconstruction algorithms have been developed which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal-density distribution present in laser-direct- drive inertial confinement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3-D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. The uncertainties involved in these 3-D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 700 to <400 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗