Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fans”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Cooling and dietary crude protein affected milk production on heat-stressed dairy cows

Environmental factors, such as temperature and humidity, exert dramatic effects on the production, health, and well-being of lactating dairy cows. Heat-stressed cows undergo a series of homeorhetic adaptations that alters cellular homeostasis and nutrient utilization. As such, the objective of this study was to determine the effects of cooling and dietary crude protein (CP) content on fermentability of rumen inoculum, milk production, and health of heat-stressed cows. It was hypothesized that cooled but not heat-stressed cows would support productivity in response to an increase in dietary CP content. Thirty-six multiparous Holstein cows were randomly assigned to 1 of 4 treatments in a 2 × 2 factorial arrangement (9 cows/treatment). Treatments consisted of cooling (CO) or moderate long-term heat stress (HS) and diets containing low CP content (LCP; 12.5% CP) or moderate CP content (MCP; 16.1% CP) of dry matter. The CO treatment provided heat abatement with sprinklers and fans that came on at > 20.0°C, whereas the HS treatment did not provide sprinklers and fans. Cows were housed in pens in a freestall barn, and treatments were imposed for 21 d during July and August. Compared with the HS treatment, CO decreased afternoon rectal and vaginal temperatures (0.60 and 0.70°C) and afternoon respiration rate (27.6 breaths/min). Treatment interactions showed that compared with the LCP treatment, MCP increased milk fat yield (23%) in CO but not in HS cows. Compared with the LCP treatment, MCP decreased milk protein percent (0.14 units) in CO but increased milk protein percent (0.09 units) in HS cows. Rumen inoculum collected on d 21 showed a ~3-fold increase in total gas production in vitro in CO compared with the HS treatment. Relative to the LCP treatment, MCP increased plasma glucose and insulin and decreased total free fatty acids concentrations. In summary, under the conditions of this study CO but not HS cows responded to a CP stimulus by increasing productivity.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of the air-cooled supercritical carbon dioxide recompression cycle design-point on molten salt power tower techno-economic performance

Here, this paper investigates the techno-economic performance of a molten salt power tower integrated with an air-cooled supercritical carbon dioxide recompression cycle. Prior research into the cycle design point showed trade-offs between efficiency, cost, and temperature difference across the heat input, resulting in trade-offs between the design-point generation of the molten salt power tower system and the cost of sensible-heat thermal energy storage. Prior research into cycle off-design showed that colder ambient temperature designs have higher efficiencies on cold days but lower efficiency and capacity degradation on hot days. We present a framework to evaluate how cycle design, cost, and corresponding off-design performance affect the techno-economic performance of the molten salt power tower system. We use a steady-state off-design cycle model assuming fixed shaft speeds, inventory control, and air-cooler fan power control and integrate the cycle model with the molten salt power tower model from the National Renewable Energy Laboratory's System Advisor Model. First, we present a surrogate model that uses a heuristic approach to correct the interpolation when the cycle reaches capacity limitations at ambient temperatures hotter than design. Next, we evaluate how the recompression cycle design-point ambient temperature, air-cooler approach temperature, air-cooler fan power, and recuperator conductance influence cycle and system design metrics. Finally, we complete annual simulations using an hourly "duck curve" pricing schedule and present annual performance metrics to evaluate the cumulative effects of the cycle design parameters and corresponding off-design performance on molten salt power tower techno-economics.

14 SOLAR ENERGY↗

Thermally Significant Fluid Seepage Through Thick Sediment on the Juan de Fuca Plate Entering the Cascadia Subduction Zone

We use heat flux measurements colocated with seismic reflection profiles over a buried basement high on the Juan de Fuca plate ∼25 km seaward of the deformation front offshore Oregon to test for the presence of hydrothermal circulation in the oceanic crust. We also revisit heat flux data crossing a buried basement high ∼25 km seaward of the deformation front ∼150 km north, offshore Washington. Seafloor heat flux is inversely correlated with sediment thickness, consistent with vigorous hydrothermal circulation in the basement aquifer homogenizing temperatures at the top of the basement. Heat flux immediately above the summit of the basement highs is greater than expected solely from conduction. Fluid seepage at rates of ∼2.6–5.4 cm yr −1 in a 1–1.5 km-wide conduit through ∼800–1,300 m thick sediment sections above these basement highs can explain these observations. Observations of thermally significant fluid seepage through sediment >225 m thick on oceanic crust are unprecedented. High sediment permeability, high fluid overpressure in the basement, or a combination of both is required to drive fluid seepage at the observed rates. We infer that rapid seepage occurs because the basement highs rise above the low permeability basal sediment with their tops protruding into the base of high permeability Nitinat or Astoria Fan sediment. Seepage from basement highs penetrating into the submarine fans can affect the thermal state of crust entering the subduction zone.

58 GEOSCIENCES↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Numerical Investigation of the Spark Discharge Process in a Crossflow

The present study numerically investigates the spark discharge process under crossflow conditions using a thermal equilibrium plasma solver that fully couples the electromagnetic physics and fluid dynamics in a computational framework. Numerical results are validated by the comparison with experimental data. Here, the spark discharge experiment is performed in a constant volume vessel using an inductive coil ignition system for automotive applications, and the evolution of the spark channel is measured using high-speed imaging. The crossflow in the gap between the spark-plug electrodes is generated by a rotating fan with two different fan speeds, and the flow velocity across the gap is characterized by particle image velocimetry (PIV) measurement. A computational fluid dynamics (CFD) solver is employed to simulate the crossflow and provide the flow field variables (velocity, pressure, temperature) to the plasma solver. The crossflow velocity predicted in the flow simulation agrees well with the PIV data in that the non-uniform velocity profiles at monitoring points are reproduced by the CFD code. With the crossflow initialization in the plasma solver, the simulated spark discharge process from the breakdown to spark discharge matches the experimental data, including the voltage and circuit waveforms and the high-speed images of the spark channel evolution. The stretch of spark channel captured by plasma simulations agrees with the measured data. The plasma simulation reveals that the mean temperature of the spark channel is maintained at 5000 K during the discharge phase, and the temperature varies along the spark channel so that the highest value is obtained at the spark root on the center electrode. Overall, the results presented in this paper are meant to provide valuable information about the properties of the plasma generated by the spark discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radon Kinetics in a Basement Space Measured with Different Devices

Although indoor monitoring of radon and benchmarking of radon measurement devices remain important research topics, few intercomparisons of active radon measurement devices have been performed under realistic conditions, let alone dynamic ones enabling comparison of their transient behavior. Five different radon monitors were therefore placed in a poorly ventilated basement space under three different conditions: 24 h under a steady, elevated radon level, 24 h with fans turned on to produce a radon washout transient, and 9 d with fans turned off for a radon buildup transient. Resulting radon concentrations varied between ~200 and ~2,000 Bq m -3 . Accuracy of the devices were evaluated using root-mean-square error, and ventilation data were fit to first order linear compartmental models. To more accurately model behaviors such as cyclic diurnal variations, the source term corresponding to entry of radon from soil into the basement was considered to be non-constant, as it is likely to vary drastically with both the indoor-outdoor pressure differential and soil concentration variations. Here, the improved radon washout model fit very well with the measurements. Despite a wide variety in list prices, all devices performed similarly during transients and at different radon concentrations.

60 APPLIED LIFE SCIENCES↗

Landau level of fragile topology

Here, we study the Hofstadter butterfly and Landau levels of the twisted bilayer graphene (TBG). We show that the nontrivial fragile topology of the lowest two bands near the charge neutral point makes their Hofstadter butterfly generically connected with higher bands, closing the gap between the first and second conduction (valence) bands at a certain magnetic flux per unit cell. We also develop a momentum space method for calculating the TBG Hofstadter butterfly, from which we identify three phases where the Hofstadter butterflies of the lowest two bands and the higher bands are connected in different ways. We show this leads to a crossing between the $\textit{ν}$ = 4 Landau fan from the charge neutral point and the zero-field band gap at one flux per moiré unit cell, which corresponds to a magnetic field 25$θ^2$ T (twist angle $\textit{θ}$ in degrees). This provides an experimentally testable feature of the fragile topology. In general, we expect it to be a generic feature that the Hofstadter butterfly of the topological bands are connected with the Hofstadter spectra of other bands. We further show the TBG band theory with Zeeman splitting being the most sizable splitting could result in Landau fans at the charge neutral point and half fillings near the magic angle, and we predict their variations under an in-plane magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strong magnetocaloric effect induced by spin reorientation transitions in epitaxial Ho thin films

In this work, magnetocaloric effect (MCE) in an antiferromagnetic holmium (Ho) film is studied near the spin reorientation temperatures. A series of magnetization isotherms from 60 to 150 K around the Néel temperature, $T_N$ ≈ 130 K were recorded for both in-plane and out-of-plane magnetic field orientations. A change in entropy, Δ$S_M$ of –5 J/kgK was found near $T_N$ for an in-plane field orientation. A large change in Δ$S_M$ of –11.8 J/kg K due to a fan-helix spin transition at $\textit{T}$ = 90 K is observed for an in-plane field orientation. Spin transition at both $T_N$ and at the fan-helix transition exhibit larger MCE in the in-plane field orientations in comparison with the perpendicular orientation. The value of the refrigerant capacity extracted from the temperature dependence of Δ$S_M(T)$ is found to be larger for the “in- plane” orientation by a factor of two.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identification of Non-Fermi Liquid Physics in a Quantum Critical Metal via Quantum Loop Topography

Non-Fermi liquid physics is ubiquitous in strongly correlated metals, manifesting itself in anomalous transport properties, such as a $\textit{T}$-linear resistivity in experiments. However, its theoretical understanding in terms of microscopic models is lacking, despite decades of conceptual work and attempted numerical simulations. In this work, we demonstrate that a combination of sign-problem-free quantum Monte Carlo sampling and quantum loop topography, a physics-inspired machine-learning approach, can map out the emergence of non-Fermi liquid physics in the vicinity of a quantum critical point (QCP) with little prior knowledge. Using only three parameter points for training the underlying neural network, we are able to robustly identify a stable non-Fermi liquid regime tracing the fans of metallic QCPs at the onset of both spin-density wave and nematic order. In particular, we establish for the first time that a spin-density wave QCP commands a wide fan of non-Fermi liquid region that funnels into the quantum critical point. Our study thereby provides an important proof-of-principle example that new physics can be detected via unbiased machine-learning approaches.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

LowFive v1.0

LowFive is a new data transport layer based on the HDF5 data model, for in situ workflows. Executables using LowFive can communicate in situ (using in-memory data and MPI message passing), reading and writing traditional HDF5 files to physical storage, and combining the two modes. Minimal and often no source-code modification is needed for programs that already use HDF5. LowFive maintains deep copies or shallow references of datasets, configurable by the user. More than one task can produce (write) data, and more than one task can consume (read) data, accommodating fan-in and fan-out in the workflow task graph. LowFive supports data redistribution from n producer processes to m consumer processes.

Morozov, Dmitriy↗

Tides on South Mill Apartment Complex

This dataset includes data from the building management system for a large multi-family rental property located in Tempe, Arizona. The name of this rental property is “Tides on South Mill” and it is owned by the FCP which is a real-estate investment company based in Maryland with a large portfolio of rental properties that spreads out throughout the U.S. FCP’s portfolio includes large multi-family housing and commercial buildings. The property is split into four quadrants. Each quadrant has roughly 130 apartments. The total floor area of each Quadrant is about 94,000 sq. ft. The campus of Solara spreads over 27 acres. The mechanical system consists of a 2-pipe system that runs chilled or hot water thru individual Fan Coil Units depending upon the season. The gas-fired boiler will supply hot water when seasonal change-over will take place. This dataset spans October to December 2021 and includes time-series measurements corresponding electricity meter data (Cooling Tower Fan, Pumps, Chillers,) with 1-minute resolution, chilled water temperature data and outside air data with 5-minute resolution etc. as CSV files. In addition to the measurements, a metadata .json file, and a .pdf dataset description file are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated parameter and process learning for hydrologic and biogeochemical modules in Earth System Models

Focus area: Primary focal area #2; secondary focal area #3: Learning about parameters and processes of land surface hydrologic and biogeochemical models in Earth System models by integrating machine learning, physics, and big data. Science challenges: How do we maximally leverage big-data observations to improve hydrobiogeochemical process description and parameterization so that such modules more realistically capture hydrologic and vegetation responses and feedbacks under the future climate? For example, how can we leverage physics, limited observations of vegetation and streamflow to better estimate evapotranspiration, and, relatedly, net primary productivity, especially for drought areas? Vegetation plays a critical role in regional and global water cycles; however, existing vegetation models have failed to predict vegetation response to droughts (McDowell & Xu, 2017) , arctic greening (Keenan & Riley, 2018) , and critical transitions between forest and savanna (Hirota et al., 2011) . These studies suggest that when we build process-based models (PBM) parameterized from regional and global plant traits, we tend to poorly describe plant adaptation and local-scale competition processes. The models and their associated parameters assigned for different regions in the world are not capturing essential heterogeneity in vegetation responses at finer spatial scales. Many parameters of the land surface models control hydrology and vegetation dynamics at the same time. The heterogeneity in vegetation response is a function of (i) plant type, (ii) plant size, (iii) competition and succession, (iv) environmental controls, and (v) local variations due to the unique ecological community that are very difficult to describe (e.g., the size of gaps resulting from fire that facilitated the coexistence of pioneering species). In the demographic models, only factors (i) and (iv) were captured, and plant types were generally described only by leaf phenology and climate zones. With current demographic models, we generally consider more traits to define plant types (i) and calibrate these traits to consider factors (ii), (iii) and (iv); however, it is substantially challenging to scale to regional and global simulations due to trait variations across space (Ali et al., 2016). Moreover, it has been noted that hillslope processes, including ridge-to-valley flow and sunny vs. shady slopes are primary organizers of water, energy, and vegetation (Clark et al., 2015; Fan et al., 2019) . Although gradual improvements in the hydrologic model component in earth system models may reduce this error (at a remarkably slow pace), the long-term, gradual impact of hydrology on plant traits are not well captured. Recent work showed that the hydrologic controls exerted by groundwater and lateral flow are primary regulators of rooting depth (Fan et al., 2017) . Such hydrologic controls have seldom been reflected in vegetation model parameterizations.

54 ENVIRONMENTAL SCIENCES↗