Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Coherent anti-Stokes Raman microspectroscopy using spectral focusing with glass dispersion

We demonstrate experimentally that coherent anti-Stokes Raman microspectroscopy with high spectral resolution is achieved using femtosecond laser pulses chirped up to a few picoseconds by glass elements of known group-velocity dispersion without significant intensity losses. By simply choosing the length of the glass, the chirp of Stokes and pump pulses is tailored to obtain a spectral resolution given by the Fourier limit of the chirped pulse duration. We show that for chirped pulse durations shorter than or comparable to the Raman coherence time, maximum signal occurs for a pump arriving after the Stokes pulse, a time-ordering effect confirmed by numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response to 'Comment on 'Pinch current limitation effect in plasma focus'' [Appl. Phys. Lett. 94, 076101 (2009)]

The main point of the comment [Appl. Phys. Lett. 94, 076101 (2009)] is that Eq. (2) and consequentially Eq. (3) of the commented paper [Appl. Phys. Lett. 92, 021503 (2008)] require correction. The alternative equation suggested in the comment is derived using Kirchhoff's voltage rule. The comment consider only the energy distribution in the inductive components and the resultant equation confirms a progressive lowering of the I{sub pinch}/I{sub peak} ratio as the static inductance L{sub 0} is reduced, lowering from 0.87 to 0.31 as L{sub 0} is reduced from 100 to 5 nH according to the revised formula corresponding to Eq. (3), compared to 0.63-0.25 according to Eq. (3). This progressive lowering of the ratio I{sub pinch}/I{sub peak} due to the inductive energy distribution is one of two factors responsible for the pinch current limitation. The other factor is the progressive reduction in the L-C interaction time compared to the current dip duration denoted by {delta}{sub cap} in Eq. (2). The comment does not deal with {delta}{sub cap} at all; hence, its conclusion based on inductive energy distribution only is not useful, since in the low L{sub 0} region when pinch current limitation begins to manifest, {delta}{sub cap} becomes more and more the dominant factor. In any case, the results of the paper do not depend on Eqs. (2) and (3), which are used in the paper only for illustrative purposes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission, ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV, iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW < or approx. 30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICF APPLICATIONS OF FAST IONS GENERATED BY FOCUSING SHORT LASER PULSES ON ULTRA-THIN CAUSALLY ISOLATED TARGETS

MeV low-Z ions are expected to find application in starting ignition in high gain ICF targets. Quite stringent conditions in terms of power density and total energy are required to start fast ignition in a pre-compressed fuel by light-ion beams, this setting corresponding constraints on the design of adequate sources. In this paper are reported studies performed at ENEA (theory and experiments) on an ion source possibly suitable for fast ignition or entropy injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Whistler wave excitation and effects of self-focusing on ion beam propagation through a background plasma along a solenoidal magnetic field

This paper extends studies of ion beam transport through a background plasma along a solenoidal magnetic field by Kaganovich et al. [Phys. Plasmas 15, 103108 (2008)] to the important regime of moderate magnetic field strength satisfying omega{sub ce}>2beta{sub b}omega{sub pe}. Here, omega{sub ce} and omega{sub pe} are the electron cyclotron frequency and electron plasma frequency, respectively, and beta{sub b}=v{sub b}/c is the directed ion beam velocity normalized to the speed of light. The electromagnetic field perturbations excited by the ion beam pulse in this regime are calculated analytically and verified by comparison with the numerical simulations. The degrees of beam charge neutralization and current neutralization are estimated, and the transverse component of the Lorentz force associated with the excited electromagnetic field is calculated. It is found that the plasma response to the ion beam pulse is significantly different depending on whether the value of the solenoidal magnetic field is below or above the threshold value specified by omega{sub ce}{sup cr}=2beta{sub b}omega{sub pe}, and corresponding to the resonant excitation of large-amplitude whistler waves. The use of intense whistler wave excitations for diagnostic purposes is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tapered plasma channels to phase-lock accelerating and focusing forces in laser-plasma accelerators

Tapered plasma channels are considered for controlling dephasing of a beam with respect to a plasma wave driven by a weakly-relativistic, short-pulse laser. Tapering allows for enhanced energy gain in a single laser plasma accelerator stage. Expressions are derived for the taper, or longitudinal plasma density variation, required to maintain a beam at a constant phase in the longitudinal and/or transverse fields of the plasma wave. In a plasma channel, the phase velocities of the longitudinal and transverse fields differ, and, hence, the required tapering differs. The length over which the tapered plasma density becomes singular is calculated. Linear plasma tapering as well as discontinuous plasma tapering, which moves beams to adjacent plasma wave buckets, are also considered. The energy gain of an accelerated electron in a tapered laser-plasma accelerator is calculated and the laser pulse length to optimize the energy gain is determined.

43 PARTICLE ACCELERATORS↗

Characterization of a one dimensional focusing compound refractive lens using the rotating shearing interferometer technique

A one dimensional (1D) compound refractive lens (CRL) has been characterized using the grating based rotating shearing interferometer technique. The method is based on the calculation of moire fringes orientation to sense wavefront information. The phase shift and the optical aberration introduced by the 1D CRL on an X-ray beam were retrieved from a single moire fringe image. The radius of curvature of the lens at the apex was derived. This physical radius of the CRL, which is also closely related to the focal length of the 1D CRL, was shown to vary with the incident angle of the incoming X-ray beam onto the CRL. The experimental measurement agreed very well with the theoretical expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzer-based phase-contrast imaging system using a micro focus x-ray source

Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα{sub 1} line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing and directional beaming effects of airborne sound through a planar lens with zigzag slits

Based on the Huygens-Fresnel principle, we design a planar lens to efficiently realize the interconversion between the point-like sound source and Gaussian beam in ambient air. The lens is constructed by a planar plate perforated elaborately with a nonuniform array of zigzag slits, where the slit exits act as subwavelength-sized secondary sources carrying desired sound responses. The experiments operated at audible regime agree well with the theoretical predictions. This compact device could be useful in daily life applications, such as for medical and detection purposes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation to study the transient self focusing of laser beam in plasma

In this paper, we present the numerical simulation for the coupled system of equations governing the dynamics of laser and Ion Acoustic Wave (IAW) in a collisionless plasma, when the coupling between the waves is through ponderomotive non-linearity. The nonlinear evolution of the laser beam is studied when the pump laser is perturbed by a periodic perturbation. By changing the perturbation wave number, we have studied its effect on the nonlinear evolution pattern of laser beam. In order to have a physical insight into the nonlinear dynamics of laser beam evolution in time and space, we have studied the laser and IAW spectra containing spatial harmonics. The magnitude of these harmonics changes with time and leads to time dependent localization of laser beam in spatial domain. The nonlinear dynamics of this localization is investigated in detail by using simulation and a semi-analytical model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Existence of a return direction for plasma escaping from a pinched column in a plasma focus discharge

The use of multi-frame interferometry used on the PF-1000 device with the deuterium filling showed the existence of a return motion of the top of several lobules of the pinched column formed at the pinched plasma column. This phenomenon was observed in the presence of an over-optimal mass in front of the anode, which depressed the intensity of the implosion and the smooth surface of the pinched plasma column. The observed evolution was explored through the use of closed poloidal currents transmitted outside the pinched plasma. This interpretation complements the scenario of the closed currents flowing within the structures inside the pinched column, which has been published recently on the basis of observations from interferometry, neutron, and magnetic probe diagnostics on this device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of compression of puffing neon by deuterium current and plasma sheath in plasma focus discharge

This paper presents the results of the research of the influence of compressed neon, injected by the gas-puff nozzle in front of the anode axis by the deuterium current and plasma sheath on the evolution of the pinch, and neutron production at the current of 2 MA. The intense soft X-ray emission shows the presence of neon in the central region of the pinch. During the implosion and stopping of the plasma sheath, the deuterium plasma penetrates into the internal neon layer. The total neutron yield of 10{sup 10}–10{sup 11} has a similar level as in the pure deuterium shots. The neutron and hard X-ray pulses from fusion D-D reaction are as well emitted both in the phase of the stopping implosion and during the evolution of instabilities at the transformation of plasmoidal structures and constrictions composed in this configuration from both gases. The fast deuterons can be accelerated at the decay of magnetic field of the current filaments in these structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Converging shock wave focusing and interaction with a target

Converging shock waves in liquids can be used efficiently in the research of the extreme state of matter and in various applications. In this paper, the recent results related to the interaction of a shock wave with plasma preliminarily formed in the vicinity of the shock wave convergence are presented. The shock wave is produced by the underwater electrical explosion of a spherical wire array. The plasma is generated prior to the shock wave's arrival by a low-pressure gas discharge inside a quartz capillary placed at the equatorial plane of the array. Analysis of the Stark broadening of H{sub α} and H{sub β} spectral lines and line-to-continuum ratio, combined with the ratio of the relative intensities of carbon C III/C II and silicon Si III/Si II lines, were used to determine the plasma density and temperature evolution. It was found that during the first ∼200 ns with respect to the beginning of the plasma compression by the shock wave and when the spectral lines are resolved, the plasma density increases from 2 × 10{sup 17 }cm{sup −3} to 5 × 10{sup 17 }cm{sup −3}, while the temperature remains at the same value of 3–4 eV. Further, following the model of an adiabatically imploding capillary, the plasma density increases >10{sup 19 }cm{sup −3}, leading to the continuum spectra obtained experimentally, and the plasma temperature >30 eV at radii of compression of ≤20 μm. The data obtained indicate that the shock wave generated by the underwater electrical explosion of a spherical wire array retains its uniformity during the main part of its convergence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined dry plasma etching and online metrology for manufacturing highly focusing x-ray mirrors

A new figuring station was designed and installed at the ESRF beamline BM05. It allows the figuring of mirrors within an iterative process combining the advantage of online metrology with dry etching. The complete process takes place under a vacuum environment to minimize surface contamination while non-contact surfacing tools open up the possibility of performing at-wavelength metrology and eliminating placement errors. The aim is to produce mirrors whose slopes do not deviate from the stigmatic profile by more than 0.1 µrad rms while keeping surface roughness in the acceptable limit of 0.1-0.2 nm rms. The desired elliptical mirror surface shape can be achieved in a few iterations in about a one day time span. This paper describes some of the important aspects of the process regarding both the online metrology and the etching process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗