Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Impact of gel concentration on filter fluxes in microfiltration of Hanford tank wastes and simulants

Abstract Treatment processes have been proposed that will utilize crossflow filtration to concentrate sludge waste streams at the Department of Energy's Hanford Site. Challenges associated with solid–liquid separation of the waste streams drive a necessary evaluation of available Hanford high level waste (HLW) filtration data. Limiting flux conditions during crossflow filtration are elucidated with the formation of a cake layer on the membrane surface. A mass transfer coefficient between the gel and bulk concentrations plays a critical role in determining filter flux. A correlation between the gel concentration and mass transfer coefficient is made to assist in determining filter performance of select HLW streams. As a process alternative to crossflow filtration, gravity settling of waste streams may be deployed as a solid–liquid separation technique. However, this results in a contrasting performance with the centrifuged solids concentration. A method was developed to estimate expected filtration and settling performance based on physical characterization data for Hanford tank waste samples. By assessing the estimated processing performance of HLW, technical support can be provided during flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STEPS: A Grid Search Methodology for Optimized Peptide Identification Filtering of MS/MS Database Search Results

For bottom-up proteomics there are a wide variety of database searching algorithms in use for matching peptide sequences to tandem MS spectra. Likewise, there are numerous strategies being employed to produce a confident list of peptide identifications from the different search algorithm outputs. Here we introduce a grid search approach for determining optimal database filtering criteria in shotgun proteomics data analyses that is easily adaptable to any search. Systematic Trial and Error Parameter Selection - referred to as STEPS - utilizes user-defined parameter ranges to test a wide array of parameter combinations to arrive at an optimal "parameter set" for data filtering, thus maximizing confident identifications. The benefits of this approach in terms of numbers of true positive identifications are demonstrated using datasets derived from immunoaffinity-depleted blood serum and a bacterial cell lysate, two common proteomics sample types.

Environmental Molecular Sciences Laboratory↗

Analytical estimation of the signal to noise ratio efficiency in axion dark matter searches using a Savitzky-Golay filter

The signal to noise ratio efficiency ϵ SNR in axion dark matter searches has been estimated using large-statistic simulation data reflecting the background information and the expected axion signal power obtained from a real experiment. This usually requires a lot of computing time even with the assistance of powerful computing resources. Employing a Savitzky-Golay filter for background subtraction, in this work, we estimated a fully analytical ϵ SNR without relying on large-statistic simulation data, but only with an arbitrary axion mass and the relevant signal shape information. Hence, our work can provide ϵ SNR using minimal computing time and resources prior to the acquisition of experimental data, without the detailed information that has to be obtained from real experiments. Axion haloscope searches have been observing the coincidence that the frequency independent scale factor ξ is approximately consistent with the ϵ SNR . This was confirmed analytically in this work, when the window length of the Savitzky-Golay filter is reasonably wide enough, i.e., at least 5 times the signal window.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anisotropic Total Variation Filtering

Total variation regularization and anisotropic filtering have been established as standard methods for image denoising because of their ability to detect and keep prominent edges in the data. Both methods, however, introduce artifacts: In the case of anisotropic filtering, the preservation of edges comes at the cost of the creation of additional structures out of noise; total variation regularization, on the other hand, suffers from the stair-casing effect, which leads to gradual contrast changes in homogeneous objects, especially near curved edges and corners. In order to circumvent these drawbacks, we propose to combine the two regularization techniques. To that end we replace the isotropic TV semi-norm by an anisotropic term that mirrors the directional structure of either the noisy original data or the smoothed image. We provide a detailed existence theory for our regularization method by using the concept of relaxation. The numerical examples concluding the paper show that the proposed introduction of an anisotropy to TV regularization indeed leads to improved denoising: the stair-casing effect is reduced while at the same time the creation of artifacts is suppressed.

97 MATHEMATICS AND COMPUTING↗

A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of a data assimilation method via an ensemble Kalman filter to reactive urea hydrolysis transport modeling

With growing importance of water resources in the world, remediations of anthropogenic contaminations due to reactive solute transport become even more important. A good understanding of reactive rate parameters such as kinetic parameters is the key to accurately predicting reactive solute transport processes and designing corresponding remediation schemes. For modeling reactive solute transport, it is very difficult to estimate chemical reaction rate parameters due to complex processes of chemical reactions and limited available data. To find a method to get the reactive rate parameters for the reactive urea hydrolysis transport modeling and obtain more accurate prediction for the chemical concentrations, we developed a data assimilation method based on an ensemble Kalman filter (EnKF) method to calibrate reactive rate parameters for modeling urea hydrolysis transport in a synthetic one-dimensional column at laboratory scale and to update modeling prediction. We applied a constrained EnKF method to pose constraints to the updated reactive rate parameters and the predicted solute concentrations based on their physical meanings after the data assimilation calibration. From the study results we concluded that we could efficiently improve the chemical reactive rate parameters with the data assimilation method via the EnKF, and at the same time we could improve solute concentration prediction. The more data we assimilated, the more accurate the reactive rate parameters and concentration prediction. The filter divergence problem was also solved in this study.

99 GENERAL AND MISCELLANEOUS↗

Numerical analysis of a time discretized method for nonlinear filtering problem with Lévy process observations

Abstract In this paper, we consider a nonlinear filtering model with observations driven by correlated Wiener processes and point processes. We first derive a Zakai equation whose solution is an unnormalized probability density function of the filter solution. Then, we apply a splitting-up technique to decompose the Zakai equation into three stochastic differential equations, based on which we construct a splitting-up approximate solution and prove its half-order convergence. Furthermore, we apply a finite difference method to construct a time semi-discrete approximate solution to the splitting-up system and prove its half-order convergence to the exact solution of the Zakai equation. Finally, we present some numerical experiments to demonstrate the theoretical analysis.

Mathematics↗

Wave-Vector Filtering Effect in a Novel Magnetic Nanostructure with Zero Average Magnetic Field

We report a theoretical investigation on wave-vector filtering (WVF) effect in a magnetic nanostructure, which can be experimentally realized by depositing ferromagnetic (FM) stripes on the surface of GaAs/Al{sub x}Ga{sub 1-x}As heterostructure. An appreciable WVF effect appears in this nanosystem. The WVF efficiency is associated with structural parameters of magnetic nanostructure. Therefore, such a device can be employed as a momentum filter for nanoelectronics device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reduction of amplified spontaneous emission noise using a statistical signal adaptive filter

This paper proposes a statistical signal adaptive filter (SSAF) based on adaptive total variation to reduce amplified spontaneous emission (ASE) noise in optical amplifiers, e.g. erbium doped fiber amplifiers. Non-return-to-zero on–off keying signal to noise ratio (SNR) is degraded by ASE noise. However, this can be improved by squeezing ASE using the proposed SSAF after photodetection to effectively remove the noise by analyzing the signal movement statistically. We obtained 4-dB SNR gain by reducing ASE beat noise compared with not applying SSAF. Simultaneous optical bandpass filter and SSAF application reduced the 2-dB power penalty for a 20-km optical link more than when only SSAF was used.

36 MATERIALS SCIENCE↗

Effect of Addition of Other Acids into Butyric Acid on Selective Leaching of Zinc from Basic Oxygen Steelmaking Filter Cake

The selective leaching of zinc over iron from basic oxygen steelmaking (BOS) filter cake was investigated using mixtures of butyric acid with acetic and/or propionic acid, HCl, or H{sub 2}SO{sub 4}. The main focus was to assess the effects of other acids on the zinc and iron leaching in butyric acid. The results show that slight reduction of zinc leaching and increase in iron leaching may take place with addition of acetic and propionic acids, causing a minor decrease in the selectivity of zinc leaching over iron. Intermittent addition of H{sub 2}SO{sub 4} and HCl was required to control the pH to be not less than that of pure butyric acid solution. Overall, an excellent selectivity can be maintained with the butyric acid–other acid mixtures. The results demonstrate the feasibility to use raw butyric acid without purification or waste butyric acid containing other impurity acids for leaching of zinc from the BOS filter cake to be recycled. Using high content of H{sub 2}SO{sub 4} in leaching is not recommended because it has a more detrimental effect on the selectivity of zinc leaching and may cause deposition of CaSO{sub 4} in the leaching residue which may increase the SO{sub 2} or CO{sub 2} emission in later high-temperature recycling processes.

36 MATERIALS SCIENCE↗

Effect of Coil Current on the Properties of Hydrogenated DLC Coatings Fabricated by Filtered Cathodic Vacuum Arc Technique

We successfully prepared hydrogenated DLC (a-C:H) with a thickness higher than 25 μm on stainless steel using a filtered cathode vacuum arc (FCVA) technique. The structural and mechanical properties of DLC were systematically analyzed using different methods such as x-ray photoelectron spectroscopy, Raman spectroscopy, scanning electron microscopy, Vickers hardness, nanohardness, and friction and wear tests. The effect of coil current on the arc voltage, ion current, and mechanical properties of resultant films was systematically investigated. The novelty of this study is the fabrication of DLC with Vickers hardness higher than 1500 HV, in the meanwhile with the thickness higher than 30 μm through varying the coil current with FCVA technique. The results indicated that the ion current, deposition rate, friction coefficient, and Vickers hardness of DLC were significantly affected by the magnetic field inside the filtered duct.

36 MATERIALS SCIENCE↗

Nanoparticle treated stainless steel filters for metal vapor sequestration

The ability to sequester vapor phase radioactive compounds during industrial processes reduces the exposure of workers and the environment to dangerous radioactive materials. Nanomaterials have a lot of potential in this area because they typically demonstrate size- and shape-dependent properties with higher reactivity than bulk. This is due to the increased surface area-to-volume ratio and quantum size effects. In this report, we developed a gold nanomaterial-treated stainless steel filter, namely wools and coupons, that can be efficiently used for zinc vapor sequestration. Without nanoparticle modification, stainless steel coupons do not react or alloy with Zn. Gold nanomaterials were grown onto various stainless steel filters using solution chemistry that is amenable to scaling up. Materials were characterized by electron microscopy, inductively coupled plasma mass spectroscopy and dynamic light scattering before and after exposure to zinc vapors. X-ray diffraction, high-resolution transmission electron microscopy, energy dispersive x-ray spectroscopy mapping and ultraviolet-visible spectroscopy confirm the formation of gold-zinc alloys after Zn vapor exposure. Furthermore, the effect of surface topography on nanoparticle morphology, size and loading density were also investigated, and stainless steel surface defects were found to have an impact on the Au NP growth and subsequently Zn sequestration.

36 MATERIALS SCIENCE↗

Measurements of effective actinides neutron capture cross sections in a cadmium-filtered epithermal neutron spectrum

In this work, a total of 20 actinide samples were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL): 233 U (1), 235 U (1), 236 U (1), 238 U (1), 237 Np (2), 239 Pu (1), 240 Pu (1), 242 Pu (2), 244 Pu (2), 241 Am (2), 243 Am (2), 244 Cm (2), and 248 Cm (2). The samples were loaded in a basket containing a 1.1-mm thick cadmium filter. The presence of the filter drastically changes the neutron spectrum in the samples and accentuates the reaction rates in the resonance region. Isotopic ratios were determined using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) that allowed inferring effective capture cross sections. Detailed best-estimate MCNP models of the experiment using ENDF/B-VII.0 nuclear data were developed to calculate the effective neutron cross sections and, subsequently, compare them with the cross sections inferred from experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-dimensional feature matching improves coverage for single-cell proteomics based on ion mobility filtering

Single-cell proteomics (scProteomics) promises to advance our understanding of cell functions within complex biological systems. However, a major challenge of current methods is their inability to identify and provide accurate quantitative information for low abundance proteins. Herein, we describe an ion mobility-enhanced mass spectrometry acquisition and peptide identification method, TIFF (Transferring Identification based on FAIMS Filtering), to improve the sensitivity and accuracy of label-free scProteomics. TIFF extends the ion accumulation times for peptide ions by filtering out singly charged ions. The peptide identities are assigned by a three-dimensional MS1 feature matching approach (retention time, accurate mass, and FAIMS compensation voltage). TIFF method enabled unbiased proteome analysis to a depth of >1,700 proteins in single HeLa cells with >1,100 proteins consistently identified. As a demonstration, we applied the TIFF method to obtain temporal proteome profiles of >150 single murine macrophage cells during lipopolysaccharide stimulation and identified time-dependent proteome changes.

59 BASIC BIOLOGICAL SCIENCES↗

Development and validation of an enhanced filtered drag model for simulating gas-solid fluidization of Geldart A particles in all flow regimes

Coarse-grid two-fluid simulation of gas-solid fluidized bed reactors based on the kinetic theory of granular flow exhibits a significant dependence on drag models, especially for Geldart A particles. Many drag models are available in the literature, which have been reported to work for different systems. This work focused on the evaluation of an enhanced filtered drag model along with other different drag models derived from different methods for three-dimensional two-fluid model simulations of gas-solid fluidized beds of Geldart A particles covering a broad range of fluidization regimes, including bubbling fluidization, turbulent fluidization, fast fluidization, and dilute phase transport regimes. Eight drag models were selected, which included five heterogeneous drag models and three homogeneous drag models. Comparison with the available experimental data demonstrates the need for modification of homogeneous drag models to account for the effect of mesoscale structures (i.e., bubbles and clusters). The enhanced filtered drag model and energy-minimization multi-scale (EMMS) drag models were found to achieve superior predictions in all fluidization regimes, while the other drag models were only capable of predicting certain fluidization regimes. Finally, the results of this work provide a guideline for choosing appropriate drag models for simulating Geldart A particles and suggestions on developing more reliable and general drag models applicable in all flow regimes.

42 ENGINEERING↗

A filter-dependent granular temperature model from large-scale CFD-DEM data

The computational study of strongly-coupled, gas–solid flows at scales relevant to most environmental and engineering applications requires the use of ‘coarse-grained’ methodologies such as the two-fluid model, particle-in-cell approach or the multiphase Reynolds Averaged Navier–Stokes equations. While these strategies enable computations at desirable length- and time-scales, they rely heavily on models to capture important flow physics that occur at scales smaller than the mesh. To date, the models that do exist are based on a limited set of flow conditions, such as very dilute particle phase. To this end, we leverage a large-scale repository of CFD-DEM data to develop filter-size dependent models for the mean variance in particle volume fraction, a quantity commonly used to assess the degree of clustering, and the granular temperature, a key quantity for accurately predicting gas–solid flows. In conclusion, because of its filter-size dependence, the granular temperature model can be directly translated to coarse-grained approaches and tied directly to grid size.

AMReX↗

Lowering Whole-Body Radiation Doses in Pediatric Intensity-Modulated Radiotherapy Through the Use of Unflattened Photon Beams;Flattening filter; Pediatric; Intensity-modulated radiotherapy; Second cancers; Radiation-induced malignancies

Purpose: Intensity modulated radiotherapy (IMRT) has been linked with an increased risk of secondary cancer induction due to the extra leakage radiation associated with delivery of these techniques. Removal of the flattening filter offers a simple way of reducing head leakage, and it may be possible to generate equivalent IMRT plans and to deliver these on a standard linear accelerator operating in unflattened mode. Methods and Materials: An Elekta Precise linear accelerator has been commissioned to operate in both conventional and unflattened modes (energy matched at 6 MV) and a direct comparison made between the treatment planning and delivery of pediatric intracranial treatments using both approaches. These plans have been evaluated and delivered to an anthropomorphic phantom. Results: Plans generated in unflattened mode are clinically identical to those for conventional IMRT but can be delivered with greatly reduced leakage radiation. Measurements in an anthropomorphic phantom at clinically relevant positions including the thyroid, lung, ovaries, and testes show an average reduction in peripheral doses of 23.7%, 29.9%, 64.9%, and 70.0%, respectively, for identical plan delivery compared to conventional IMRT. Conclusions: IMRT delivery in unflattened mode removes an unwanted and unnecessary source of scatter from the treatment head and lowers leakage doses by up to 70%, thereby reducing the risk of radiation-induced second cancers. Removal of the flattening filter is recommended for IMRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Photon Beams of a Flattening Filter-free Linear Accelerator for Hypofractionated Volumetric Modulated Arc Therapy in Localized Prostate Cancer

Purpose: To evaluate the potential usage of flattening filter-free (FFF) photon beams in the treatment of prostate cancer. Methods and Materials: Volumetric-modulated arc therapy (VMAT) treatment planning was performed for 7 patients using TrueBeam{sup Registered-Sign} linear accelerator and photon beams with (X6, X10) and without (X6FFF, X10FFF) flattening filter. Prescribed dose was 19 Multiplication-Sign 3 Gy = 57 Gy. One or two 360 Degree-Sign arcs with dose rate of 600 MU/min for flattened beams, and 1,200 MU/min for FFF beams were used. Results: No difference was detected between the four beams in PTV coverage, conformity, and homogeneity. Mean body dose and body volume receiving 50% of the prescribed dose decreased with increasing mean energy (r{sup 2} = 0.8275, p < 0.01). X6FFF delivered 3.6% more dose compared with the X6 (p < 0.01). X10FFF delivered 3.0% (p < 0.01), and the X10 5.8% (p < 0.01) less mean body dose compared with X6. There was a significant increase in the mean dose to the rectum for the X10 compared with X6 (2.6%, p < 0.01). Mean dose to the bladder increased by 1.3% for X6FFF and decreased by 2.3% for X10FFF. Using a single arc and FFF, treatment time was reduced by 35% (2 SD = 10%). Conclusion: FFF beams resulted in dose distributions similar to flattened beams. X10FFF beam provided the best solution, sparing rectum and bladder and minimizing whole-body dose. FFF beams lead to a time efficient treatment delivery, particularly when combined with hypofractionated VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗