Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion

We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate ''Heisenberg'' limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final CRADA Report for Enhanced and Miniaturized Wireless Valve Position Indicator Prototype

Most operating nuclear power plants (NPPs) in the United States have received approval to extend their operating licenses to 60 years. Now the nuclear industry is preparing to extend operating licenses to 80 years. While NPPs are preparing for extensions (60 years and beyond), the nuclear industry is facing a unique economic sustainability challenge in the current energy market. According to the Nuclear Energy Institute (NEI), generating costs of U.S. reactors have risen by 28% over the last 12 years, which is impacting the competitiveness of nuclear power in a market being increasingly penetrated by natural gas and renewable energy. This is partly because of the fact that the present nuclear work practice is dependent on a large technical staff which results in high operation and maintenance (O&M) costs, accounting for approximately 66% of the total operating cost. To address these concerns and abide by the NEI’s “Delivering the Nuclear Promise Initiative,” the U.S. utilities are embracing digitalization of their work practice to lower the O&M costs and increase productivity and efficiency while maintaining a safe and reliable operation. To address these above-mentioned concerns, Idaho National Laboratory (INL) researchers (proposal team) have developed a wireless valve position indication (VPI) sensor system that can be retrofitted on three main manual valve types (extendible to other manual valve types) to replace manual valve position verification with digital verification and enable online monitoring of manual valves. The developed technology 1) is evaluated for electromagnetic interference, 2) has a low power consuming and miniaturized electronic board, 3) is mounted on adjustable and reconfigurable sensor mounting unit that can fit on an actual flow-loop (at Idaho State University-ISU) to enable online monitoring of manual valve types without any valve body modification, and 4) ensures robust, secure, and reliable real-time communication of manual valve position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fact Sheet - Long-length Scintillating Fibers for Radiation Detection

As the world looks to underground geological repositories for storing nuclear waste, technologies to safeguard the material are needed. An example of a project that developed a new technology is Tripwire. Tripwire proposes a multi-sensor system approach for geological spent nuclear fuel repositories that relies of radiation, vibration, and electromagnetic detection. Tripwire was developed by the Applied Radiation Measurements and Systems (ARMS) group at INL and sponsored by the National Nuclear Security Administration (NNSA). The ARMS group performs research and development, testing and evaluation, operational support, and training focused on applied ionizing radiation detection and measurement. Application areas include nuclear engineering for advanced reactors and fuel cycle operations, nuclear nonproliferation, nuclear counterproliferation, nuclear forensics, and arms control and disarmament.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Simulation of π 0 -γ separation study for proposed CMS forward electromagnetic calorimeter

The Forward Electromagnetic Calorimeter of the CMS detector is going to be upgraded in the high luminosity running as the energy of the present Electromagnetic Calorimeter (PbWO4) will degrade in the high luminosity (luminosity 10 34 cm -2 s -1 ) running due to extensive radiation (hadron flux 10 13 neutrons cm, -2 ). Shashlik Electromagnetic Calorimeter which consists of alternate layers of 1.5 mm LYSO(Ce) crystal plates and 2.5 mm Tungsten absorbers, was a proposal for high luminosity running. One of the performance points for any electromagnetic calorimeter is the ability to separate π 0 s from true photons, since final states with photons are a clean and one of the most important final states in proton-proton collisions at the LHC. As a result, the objective of this project is to study the possibility of π 0 and γ separation in the Shashlik detector using Multivariate Analysis (MVA) technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear spectroscopy above isomers in {sub 67}{sup 148}Ho{sub 81} and {sub 67}{sup 149}Ho{sub 82} nuclei: Search for core-excited states in {sup 149}Ho

The excited states of {sup 148}Ho and {sup 149}Ho isotopes are studied using gamma-ray and electron spectroscopy in off-beam and in-beam modes following {sup 112,114}Sn({sup 40}Ar,xnyp) reactions. Experiments include measurements of single gamma-rays and conversion electron spectra as well as gamma-gamma, electron-gamma, gamma-t, and gamma-gamma-t coincidences with the use of the OSIRIS-II 12-HPGe array and conversion electron spectrometer. Based on the present results, the level schemes of {sup 148}Ho and {sup 149}Ho are revised and significantly extended, up to about 4 and 5 MeV of excitation energy, respectively. Spin and parity of 5{sup -} are assigned to the 9.59-s isomer in {sup 148}Ho based on conversion electron results. Previously unobserved gamma rays feeding the 10{sup +} isomer in {sup 148}Ho and the 27/2{sup -} isomer in {sup 149}Ho nuclei are proposed. Shell-model calculations are performed. Possible core-excited states in {sup 149}Ho are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decay properties of long-lived isomers in the odd-odd N=81 nucleus {sup 146}Tb compared to the {sup 148}Ho and {sup 150}Tm nuclei

Excited states of the {sup 146}Tb nucleus have been studied using {gamma}-ray and electron spectroscopy in off-beam and in-beam modes following {sup 112}Sn({sup 40}Ar,3n3p) reaction with the use of the OSIRIS-II, HPGe detector array and the conversion electron spectrometer. The multipolarity of the 343 keV transition deexciting the (7{sup -}) level in {sup 146}Tb shows mainly an E2 nature and the first excited state above the 23 s isomer is assigned as a (5{sup -},6{sup -}) state. The log ft values have been deduced for 11 {beta}{sup +}/EC transitions populating excited states in {sup 146}Gd. The systematic behavior of spins and parities of the long-lived levels at 0+x keV and the first excited states above them in the N=81 isotones {sup 146}Tb, {sup 148}Ho, and {sup 150}Tm is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First result for the neutrino magnetic moment from measurements with the GEMMA spectrometer

The first result obtained in the measurements of the neutrino magnetic moment at the Kalinin nuclear power plant with the GEMMA spectrometer is presented. A high-purity germanium detector of mass 1.5 kg placed at a distance of 13.9 m from the reactor core is used in the spectrometer. The antineutrino flux at the detector position is 2.73 x 10{sup 13{nu}}-bar/(cm{sup 2} s). The differential method is used to select events of electromagnetic antineutrino-electron scattering. The spectra taken in the reactor-on and reactor-off modes over 6200 and 2064 h, respectively, are compared. On the basis of a data analysis, an upper limit of 5.8 x 10{sup -11} {mu}B was set on the neutrino magnetic moment {mu}{sub {nu}}at a 90% C.L.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e experiment at Fermilab: Design and status

The Mu2e experiment at Fermilab will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus. The dynamics of such charged lepton flavour violating (CLFV) process is a twobody decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates Rμe of ≤ 6 × 10 -17 (@90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → eγ decay at MEG as well as the direct searches for new physics at the LHC. Indeed, such a CLFV process probes new physics at a scale inaccessible to direct searches at either present or planned high energy colliders. Observation of a signal will be a clear evidence for new physics beyond the Standard Model. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/s) is stopped on an aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and an electromagnetic calorimeter consisting of arrays of CsI crystals. An external veto for cosmic rays is surrounding the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. Data collection is planned for the end of 2021. Lastly, an overview of the physics motivations for Mu2e, the current status of the experiment and design of the muon beam-line and the detector is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A helical-shape scintillating fiber trigger and tracker system for the DarkLight experiment and beyond

The search for new physics beyond the Standard Model has interesting possibilities at low energies. For example, the recent 6.8σ anomaly reported in the invariant mass of e + e - pairs from 8 Be nuclear transitions and the discrepancy between predicted and measured values of muon g-2 give strong motivations for a protophobic fifth-force model. At low energies, the electromagnetic interaction is well understood and produces straightforward final states, making it an excellent probe of such models. However, to achieve the required precision, an experiment must address the substantially higher rate of electromagnetic backgrounds. Here in this paper, we present the results of simulation studies of a trigger system, motivated by the DarkLight experiment, using helical-shape scintillating fibers in a solenoidal magnetic field to veto electron–proton elastic scattering and the associated radiative processes. We also assess the performance of a tracking detector for lepton final states using scintillating fibers in the same setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CORONAL AND HELIOSPHERIC 2007 MAY 19 EVENT: CORONAL MASS EJECTION, EXTREME ULTRAVIOLET IMAGER WAVE, RADIO BURSTS, AND ENERGETIC ELECTRONS

We study the global development of the 2007 May 19 event and investigate the origin and the escape of the energetic electrons responsible for the interplanetary bursts and for the solar energetic particle event. The data analysis combines radio spectral and imaging observations with STEREO EUV observations. We also use the direction-finding capabilities on the Wind/Waves radio instrument. Electron acceleration and injections into the interplanetary medium occur with some delay after the flare. It is shown that they are related to the expansion of the coronal mass ejection and of the extreme ultraviolet imager wave. There are two accelerations at two different locations in the corona which correspond to two different electron trajectories in the interplanetary medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Cerium-doped scintillating fused-silica fibers

In this work, we report on a set of measurements made on (scintillating) cerium-doped fused-silica fibers using high-energy particle beams. These fibers were uniformly embedded in a copper absorber in order to utilize electromagnetic showers as a source of charged particles for generating signals. This new type of cerium-doped fiber potentially offers myriad new applications in calorimeters in high-energy physics, tracking systems, and beam monitoring detectors for future applications. The light yield, pulse shape, attenuation length, and light propagation speeds are given and discussed. Possible future applications are also explored.

47 OTHER INSTRUMENTATION↗

Data-Driven Validation of NOvA's Convolutional Neural Network for Electron (Anti)Neutrino Selection

NOvA is a long-baseline neutrino oscillation experiment, designed to make measurements of several oscillation parameters using muon neutrino disappearance and electron neutrino appearance. It consists of two functionally equivalent detectors and utilizes the Fermilab NuMI neutrino beam. NOvA uses a convolutional neural network for particle identification of electron neutrino events with a validation process that includes several data-driven techniques. These Muon Removed studies ensure that our classifier performs the same on data as it does on simulation. In particular, Muon Removed Electron-Added studies involve selecting muon neutrino charged current events from both data and simulation and replacing the muon with a simulated electron of similar energy. For Muon Removed Bremsstrahlung and Muon Removed Decay-in-Flight studies, we remove muonic hits from cosmic muons that have either experienced Bremsstrahlung radiation or decayed in flight, producing samples of pure electromagnetic showers. Each of these electron neutrino-like samples are then evaluated by our classifier to obtain selection efficiencies. Our most recent analysis showed good agreement in the electron selection efficiency between data and simulation using these techniques. Furthermore, these cross-checks can be extended to corrections to our predicted electron neutrino signal. The impact of one such set of corrections on the overall analysis results were also evaluated in thesis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass independent kinetic energy reducing inlet system for vacuum environment

A particle inlet system comprises a first chamber having a limiting orifice for an incoming gas stream and a micrometer controlled expansion slit. Lateral components of the momentum of the particles are substantially cancelled due to symmetry of the configuration once the laminar flow converges at the expansion slit. The particles and flow into a second chamber, which is maintained at a lower pressure than the first chamber, and then moves into a third chamber including multipole guides for electromagnetically confining the particle. The vertical momentum of the particles descending through the center of the third chamber is minimized as an upward stream of gases reduces the downward momentum of the particles. The translational kinetic energy of the particles is near-zero irrespective of the mass of the particles at an exit opening of the third chamber, which may be advantageously employed to provide enhanced mass resolution in mass spectrometry.

47 OTHER INSTRUMENTATION↗

Interface-Dependent Radiative Lifetimes of Yb3+, Er3+ Co-doped Single NaYF4 Upconversion Nanowires

The development of upconversion nanomaterials for many photonic applications requires a detailed understanding of their radiative lifetimes that in turn depend critically on local environmental conditions. In this work, hexagonal (ß-phase) sodium-yttrium-?uoride (NaYF4) nanowires (NWs) were synthesized and substitutionally co-doped with a luminescent solid solution of trivalent erbium and ytterbium ions. A single-beam laser trapping instrument was used in tandem with a piezo-controlled, variable-temperature stage to precisely vary the nanowire’s distance from the substrate. The spontaneous photoluminescence lifetime of the 4S3/2 ? 4I15/2 transition from Er3+ ions was observed to change by >60% depending on the ions’ separation distance from a planar (water/glass) dielectric interface. The 4S3/2 state lifetime is observed to increase by a factor of 1.62 ± 0.01 as the distance from the quartz coverslip increases from ~0 nm to~40 µm. Less signi?cant changes in the luminescence lifetime (=10%) were observed over a temperature range between 25 and 50 °C. The distance dependence of the lifetime is interpreted quantitatively in the context of classical electromagnetic coupling between Er3+ ions within the nanowire and the adjacent dielectric interface. We also demonstrate potential applications of the NaYF4 NWs for both controlling and probing temperatures at nanometer scales by integrating them within a poly(dimethylsiloxane) composite matrix.

upconversion, nanowires, radiative lifetime, optic↗

Multi-objective optimization with an integrated electromagnetics and beam dynamics workflow

In particle accelerators, RF cavities are used to accelerate charged particle beams to designed high energy for physical applications. In a typical accelerator design, the optimization of RF cavities and the optimization of beam dynamics are carried out in separate studies. For a more general and unrestricted accelerator design, a coupled optimization of the RF cavities and the beam parameters is required. For this coupled optimization problem, we have developed an integrated electromagnetics and beam dynamics workflow management system. Within this system, the geometries for a set of cavity components are first adjusted; the field modes are then computed with an electromagnetics program, and imported into a beam dynamics program for beam dynamics simulation. This workflow is encapsulated into a parallel multi-objective optimizer to achieve the integrated accelerator design optimization. A multi fidelity strategy is developed to improve the speed of the optimizer. Furthermore, this integrated global optimization capability is illustrated using a photoinjector design example and yields an improved design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of absorber coupled TES polarimeter at millimeter wavelengths.

We report an absorber coupled TES bolometric polarimeter, consisting of an absorptive metal grid and a Mo/Au bi-layer TES on a suspended silicon nitride membrane disk. The electromagnetic design of the polarization sensitive absorbers, the heat transport modeling of the detector, the thermal response of the TES, and the micro-fabrication processes are presented. We also report the results of laboratory tests of a single pixel prototype detector, and compare with theoretical expectations.

47 OTHER INSTRUMENTATION↗

Observations of electron beam structure in space experiments

Observations of a 100-mA, 1-keV electron beam were made with a low light level TV system and other instruments aboard the space shuttle STS 3 in March 1982. When fired at a moderate pitch angle with respect to the magnetic field, the beam electrons initially moved outward along a classical helical trajectory. Within a short distance, however, the beam electrons were deflected away from the helical trajectory into paths parallel to magnetic field lines threading the primary helix. This resulted in the formation of a thin-walled, cylindrical electron beam structure having a radius equal to the primary beam gyroradius. This structure, which is consistent with earlier laboratory vacuum chamber observations and recent two-dimensional computer electrostatic plasma simulations, has important implications for determining the extent to which pulsed electron beams can radiate electromagnetic energy in the ionosphere.

Banks, Peter M.↗

Tuneable photonic device including an array of metamaterial resonators

A photonic apparatus includes a metamaterial resonator array overlying and electromagnetically coupled to a vertically stacked plurality of quantum wells defined in a semiconductor body. An arrangement of electrical contact layers is provided for facilitating the application of a bias voltage across the quantum well stack. Those portions of the semiconductor body that lie between the electrical contact layers are conformed to provide an electrically conductive path between the contact layers and through the quantum well stack.

36 MATERIALS SCIENCE↗