Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Experimental Determination of the HPGe Spectrometer Efficiency Calibration Curves for Various Sample Geometry for Gamma Energy from 50 keV to 2000 keV

Detection efficiency of a gamma-ray spectrometry system is dependent upon among others, energy, sample and detector geometry, volume and density of the samples. In the present study the efficiency calibration curves of newly acquired (August 2008) HPGe gamma-ray spectrometry system was carried out for four sample container geometries, namely Marinelli beaker, disc, cylindrical beaker and vial, normally used for activity determination of gamma-ray from environmental samples. Calibration standards were prepared by using known amount of analytical grade uranium trioxide ore, homogenized in plain flour into the respective containers. The ore produces gamma-rays of energy ranging from 53 keV to 1001 keV. Analytical grade potassium chloride were prepared to determine detection efficiency of 1460 keV gamma-ray emitted by potassium isotope K-40. Plots of detection efficiency against gamma-ray energy for the four sample geometries were found to fit smoothly to a general form of {epsilon} = A{Epsilon}{sup a}+B{Epsilon}{sup b}, where {epsilon} is efficiency, {Epsilon} is energy in keV, A, B, a and b are constants that are dependent on the sample geometries. All calibration curves showed the presence of a ''knee'' at about 180 keV. Comparison between the four geometries showed that the efficiency of Marinelli beaker is higher than cylindrical beaker and vial, while cylindrical disk showed the lowest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of dust grain charge and screening lengths in the plasma sheath by means of a controlled cluster rotation

Dusty plasma experiments with flat dust clusters are often performed in the boundary sheath of radio frequency discharges at typical gas pressures of 1-100 Pa. The interaction of the dust grains is usually assumed to be of the Yukawa type, which is determined by the particle charge and the screening length. For the experimental determination of these quantities we present a method that does not require prior knowledge of the plasma parameters. The method is based on the application of centrifugal forces by means of a rotating electrode method (REM). The results are critically compared with an analysis of thermally excited normal modes, which can be studied at pressures below 10 Pa. The REM has a wider range of applicability that can be extended to 100 Pa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two recent high-precision determinations of {alpha}{sub s}

The two highest precision determinations of {alpha}{sub s}(M{sub Z}{sup 2}), that based on the analysis of short-distance-sensitive lattice observables, and that based on an analysis of hadronic {tau} decay data, have, until recently, yielded results differing by {approx}3{sigma}. I review recent updates which bring the two determinations into excellent agreement, and discuss prospects for additional future improvements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On how once subtracted dispersion relations lead to a precise determination of {pi}{pi} scattering and the f{sub 0}(600) parameters

We present and compare once and twice subtracted dispersion relations including crossing symmetry constraints in order to test the S- and P-wave {pi}{pi} amplitudes below 1100 MeV. We show that twice subtracted dispersion relations provide stringent constraints on the {pi}{pi} amplitudes below about 400 MeV than those with one subtraction. Above this energy GKPY eqs. become, however, a more demanding test of {pi}{pi} amplitudes, thus providing a new tool for the precise determination of {pi}{pi} scattering. We also show that due to strong constraints imposed by the GKPY eqs. they are useful for the determination of the f{sub (600)} pole position with high accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the minimum value of the safety factor from geodesic Alfven eigenmodes in Joint European Torus

An analysis of the experimental conditions under which low-frequency (70-150 kHz) Alfven eigenmodes (AE) are excited during the monster sawtooth in Joint European Torus [F. Romanelli et al., Proceedings of the 22nd IAEA Fusion Energy Conference, Geneva, Switzerland, 2008] is presented for the specific case of a discharge with ion cyclotron heating (5 MW). Using a simplified AE model for modes excited at the Alfven wave continuum maximum with geodesic corrections taken into account, the temporal evolution of the value of the safety factor q{sub 0} at the magnetic axis is determined. We describe a new scheme to determine the time variation of q{sub 0} that works under conditions in which other standard diagnostics, such as the motional Stark effect do not give reliable results such as during a monster sawtooth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A numerical method for determining highly precise electron energy distribution functions from Langmuir probe characteristics

Electron energy distribution functions (EEDFs) were determined from probe characteristics using a numerical ac superimposed method with a distortion correction of high derivative terms by varying amplitude of a sinusoidal perturbation voltage superimposed onto the dc sweep voltage, depending on the related electron energy. Low amplitude perturbation applied around the plasma potential represented the low energy peak of the EEDF exactly, and high amplitude perturbation applied around the floating potential was effective to suppress noise or distortion of the probe characteristic, which is fatal to the tail electron distribution. When a small random noise was imposed over the stabilized prove characteristic, the numerical differentiation method was not suitable to determine the EEDF, while the numerical ac superimposed method was able to obtain a highly precise EEDF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strain Determination Using Electron Backscatter Diffraction

In the present paper we demonstrate the use of electron backscatter diffraction (EBSD) for high resolution elastic strain determination. Here, we focus on analysis methods based on determination of small shifts in EBSD pattern with respect to a reference pattern using cross-correlation algorithms. Additionally we highlight the excellent spatial and depth resolution of EBSD and introduce the use of simulated diffraction patterns based on dynamical diffraction theory for sensitivity estimation. Moreover the potential of EBSD for strain analysis of strained thin films with particular emphasis on appropriate target preparation which respect to occurring lattice defects is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel method for determining the M-band fraction in laser-driven gold hohlraums

A novel method is proposed for determining the M-band (2-4 keV) fraction in laser-driven gold (Au) hohlraums, based on our study on the responses of x-ray ablative shock waves to Au M-band radiation flux in aluminum (Al) and titanium (Ti). Due to their different opacity properties, the velocity of shock wave in Al decreases as the M-band fraction, while increases in Ti. The scaling relation of radiation temperature with shock velocity and M-band fraction is given for Al and Ti materials. Our method provides a complementary means in determining the M-band fraction in a hohlraum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the Bohm criterion in plasmas with two ion species

A model that uniquely determines the flow speed of each ion species at the sheath edge of two ion species plasmas is developed. In this analysis, ion-ion two-stream instabilities can play an important role because they significantly enhance the friction between ion species. Two-stream instabilities arise when the difference in flow speeds between the ion species exceeds a critical value: V{sub 1}-V{sub 2}{identical_to}{Delta}V{>=}{Delta}V{sub c}. The resultant instability-enhanced friction rapidly becomes so strong that {Delta}V cannot significantly exceed {Delta}V{sub c}. Using the condition provided by {Delta}V={Delta}V{sub c} and the generalized Bohm criterion, the speed of each ion species is uniquely determined as it leaves a quasineutral plasma and enters a sheath. Previous work [S. D. Baalrud et al., Phys. Rev. Lett. 103, 205002 (2009)] considered the cold ion limit (T{sub i}{yields}0), in which case {Delta}V{sub c}{yields}0 and each ion species obtains a common ''system'' sound speed at the sheath edge. Finite ion temperatures are accounted for in this work. The result is that {Delta}V{sub c} depends on the density and thermal speed of each ion species; {Delta}V{sub c} has a minimum when the density ratio of the two ion species is near one, and becomes larger as the density ratio deviates from unity. As {Delta}V{sub c} increases, the speed of each ion species approaches its individual sound speed at the sheath edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Two Methods of Noise Power Spectrum Determinations of Medical Radiography Systems

Noise in medical images is recognized as an important factor that determines the image quality. Image noise is characterized by noise power spectrum (NPS). We compared two methods of NPS determination namely the methods of Wagner and Dobbins on Lanex Regular TMG screen-film system and Hologic Lorad Selenia full field digital mammography system, with the aim of choosing the better method to use. The methods differ in terms of various parametric choices and algorithm implementations. These parameters include the low pass filtering, low frequency filtering, windowing, smoothing, aperture correction, overlapping of region of interest (ROI), length of fast Fourier transform, ROI size, method of ROI normalization, and slice selection of the NPS. Overall, the two methods agreed to the practical value of noise power spectrum between 10{sup -3}-10{sup -6} mm{sup 2} over spatial frequency range 0-10 mm{sup -1}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

07 ISOTOPE AND RADIATION SOURCES↗

Using Photon Activation Analysis To Determine Concentrations Of Unknown Components In Reference Materials

Using certified multi-element reference materials for instrumental analyses one frequently is confronted with the embarrassing fact that the concentration of some desired elements are not given in the respective certificate, nonetheless are detectable, e.g. by photon activation analysis (PAA). However, these elements might be determinable with sufficient quality of the results using scaling parameters and the well-known quantities of a reference element within the reference material itself. Scaling parameters include: activation threshold energy, Giant Dipole Resonance (GDR) peak and endpoint energy of the bremsstrahlung continuum; integrated photo-nuclear cross sections for the isotopes of the reference element; bremsstrahlung continuum integral; target thickness; photon flux density. Photo-nuclear cross sections from the unreferenced elements must be known, too. With these quantities, the integral was obtained for both the known and unknown elements resulting in an inference of the concentration of the unreported element based upon the reported value, thus also the concentration of the unreferenced element in the reference material. A similar method to determine elements using the basic nuclear and experimental data has been developed for thermal neutron activation analysis some time ago (k{sub 0} Method).

07 ISOTOPE AND RADIATION SOURCES↗

Determination of Specific Forces and Tool Deflections in Micro-milling of Ti-6Al-4V alloy using Finite Element Simulations and Analysis

Titanium alloys offer superb properties in strength, corrosion resistance and biocompatibility and are commonly utilized in medical devices and implants. Micro-end milling process is a direct and rapid fabrication method for manufacturing medical devices and implants in titanium alloys. Process performance and quality depend upon an understanding of the relationship between cutting parameters and forces and resultant tool deflections to avoid tool breakage. For this purpose, FE simulations of chip formation during micro-end milling of Ti-6Al-4V alloy with an ultra-fine grain solid carbide two-flute micro-end mill are investigated using DEFORM software.At first, specific forces in tangential and radial directions of cutting during micro-end milling for varying feed advance and rotational speeds have been determined using designed FE simulations for chip formation process. Later, these forces are applied to the micro-end mill geometry along the axial depth of cut in 3D analysis of ABAQUS. Consequently, 3D distributions for tool deflections and von Misses stress are determined. These analyses will yield in establishing integrated multi-physics process models for high performance micro-end milling and a leap-forward to process improvements.

36 MATERIALS SCIENCE↗

Neutron Coherent Scattering Length Determination With a Dual Non-Dispersive Sample

We report here a preliminary interferometric determination of neutron coherent scattering length b{sub C} for silicon using a dual non-dispersive sample. A large and exactly non-dispersive phase measured by this method can afford an order of magnitude improvement in the precision of b{sub C} determination to within a few parts in 10{sup 6}.

36 MATERIALS SCIENCE↗

New determination of the N-{Delta}(1232) axial form factors from weak pion production and coherent pion production off nuclei at T2K and MiniBooNE energies revisited

We re-evaluate our model predictions in Phys. Rev. D 79, 013002 (2009) for different observables in neutrino induced coherent pion production. This comes as a result of the new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-Delta form factor. We find an increase of 20%{approx}30% in the values for the total cross sections. Uncertainties induced by the errors in the determination of C{sub 5}{sup A} are computed. Our new results turn out to be compatible within about 1{sigma} with the former ones. We also stress the existing tension between the recent experimental determination of the {sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0}) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision laser-assisted absolute determination of x-ray diffraction angles

A novel technique for absolute wavelength determination in high-precision crystal x-ray spectroscopy recently introduced has been upgraded reaching unprecedented accuracies. The method combines visible laser beams with the Bond method, where Bragg angles ({theta} and -{theta}) are determined without any x-ray reference lines. Using flat crystals this technique makes absolute x-ray wavelength measurements feasible even at low x-ray fluxes. The upgraded spectrometer has been used in combination with first experiments on the 1s2p {sup 1}P{sub 1}{yields} 1s{sup 2} {sup 1}S{sub 0} w-line in He-like argon. By resolving a minute curvature of the x-ray lines the accuracy reaches there the best ever reported value of 1.5 ppm. The result is sensitive to predicted second-order QED contributions at the level of two-electron screening and two-photon radiative diagrams and will allow for the first time to benchmark predicted binding energies for He-like ions at this level of precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single x-ray transmission system for bone mineral density determination

Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm{sup 2})], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of optical damage cross-sections and volumes surrounding ion bombardment tracks in GaAs using coherent acoustic phonon spectroscopy

We report the results of coherent acoustic phonon spectroscopy analysis of band-edge optical modification of GaAs irradiated with 400 keV Ne{sup ++} for doses between 10{sup 11}-10{sup 13} cm{sup -2}. We relate this optical modification to the structural damage density as predicted by simulation and verified by ion channeling analysis. Crystal damage is observed to cause optical modification that reduces the amplitude of the optoacoustic signal. The depth-dependent nature of the optoacoustic measurement allows us to determine optical damage cross-sections along the ion track, which are found to vary as a function of position along the track. Unexpectedly, we find that this optical modification is primarily dependent on the structural damage density and insensitive to the specific defect configuration along the ion track, suggesting that a simple model of defect density along the track is sufficient to characterize the observed optical changes. The extent of optical modification is strongly probe frequency-dependent as the frequency is detuned from the GaAs band edge. As determined from the experimental measurements, the spatial extent of optical modification exceeds the spatial extent of the structural disorder by an order of magnitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗