Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Expected background in the LZ experiment

The LZ experiment, featuring a 7-tonne active liquid xenon target, is aimed at achieving unprecedented sensitivity to WIMPs with the background expected to be dominated by astrophysical neutrinos. To reach this goal, extensive simulations are carried out to accurately calculate the electron recoil and nuclear recoil rates in the detector. Both internal (from target material) and external (from detector components and surrounding environment) backgrounds are considered. A very efficient suppression of background rate is achieved with an outer liquid scintillator veto, liquid xenon skin and fiducialisation. Based on the current measurements of radioactivity of different materials, it is shown that LZ can achieve the reduction of a total background for a WIMP search down to about 2 events in 1000 live days for 5.6 tonne fiducial mass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of an INTEGRAL spectrometer model

Model calculations for the INTEGRAL spectrometer (SPI) onboard the future INTErnational Gamma Ray Astrophysics Laboratory (INTEGAL) are presented, where the sensitivity for narrow lines is based on estimates of the background level and the detection efficiency. The instrumental background rates are explained as the sum of various components that depend on the cosmic ray intensity and the spectrometer characteristics, such as the mass distribution around the Ge detectors, the passive material, the characteristics of the detector system and the background reduction techniques. Extended background calculations were performed with Monte Carlo simulations and using semi-empirical and calculated neutron and proton cross sections. In order to improve the INTEGRAL spectrometer sensitivity, several designs and background reduction techniques were compared for an instrument with a fixed detector volume.

Jean, P.↗

Parameter extraction for a SPICE model of an hTron superconducting thermal switch

Efficiently simulating large circuits is crucial to the development of superconducting nanowire-based electronics. However, current simulation tools for this technology are not adapted to the scaling of circuit size and complexity. We focus on the multilayered heater-nanocryotron (hTron), a promising superconducting nanowire-based switch used in applications such as superconducting nanowire single-photon detector readout. Previously, the hTron was modeled using traditional finite-element methods, which fall short in simulating systems at a larger scale. An empirical-based method would be better adapted to this task, enhancing both simulation speed and agreement with experimental data. In this work, we perform switching current and activation delay measurements on 17 hTron devices. We then develop a method for extracting physical fitting parameters used to characterize the devices. We build a SPICE behavioral model that reproduces the static and transient device behavior using these parameters, and validate it by comparing its performance to a model developed in prior work, showing an improvement in simulation time by several orders of magnitude. Furthermore, our model provides circuit designers with a tool to help understand the hTron’s behavior during all design stages, thus enabling broader use of the hTron across various new areas of application.

Caloritronics↗

The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection

The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prospects for direct detection of dark matter in an effective theory approach

We perform the first comprehensive analysis of the prospects for direct detection of dark matter with future ton-scale detectors in the general 11-dimensional effective theory of isoscalar dark matter-nucleon interactions mediated by a heavy spin-1 or spin-0 particle. The theory includes 8 momentum and velocity dependent dark matter-nucleon interaction operators, besides the familiar spin-independent and spin-dependent operators. From a variegated sample of 27 benchmark points selected in the parameter space of the theory, we simulate independent sets of synthetic data for ton-scale Germanium and Xenon detectors. From the synthetic data, we then extract the marginal posterior probability density functions and the profile likelihoods of the model parameters. The associated Bayesian credible regions and frequentist confidence intervals allow us to assess the prospects for direct detection of dark matter at the 27 benchmark points. First, we analyze the data assuming the knowledge of the correct dark matter nucleon-interaction type, as it is commonly done for the familiar spin-independent and spin-dependent interactions. Then, we analyze the simulations extracting the dark matter-nucleon interaction type from the data directly, in contrast to standard analyses. This second approach requires an extensive exploration of the full 11-dimensional parameter space of the dark matter-nucleon effective theory. Interestingly, we identify 5 scenarios where the dark matter mass and the dark matter-nucleon interaction type can be reconstructed from the data simultaneously. We stress the importance of extracting the dark matter nucleon-interaction type from the data directly, discussing the main challenges found addressing this complex 11-dimensional problem.

79 ASTRONOMY AND ASTROPHYSICS↗

A global stochastic programming approach for the optimal placement of gas detectors with nonuniform unavailabilities

Optimal design of a gas detection systems is challenging because of the numerous sources of uncertainty, including weather and environmental conditions, leak location and characteristics, and process conditions. Rigorous CFD simulations of dispersion scenarios combined with stochastic programming techniques have been successfully applied to the problem of optimal gas detector placement; however, rigorous treatment of sensor failure and nonuniform unavailability has received less attention. To improve reliability of the design, this paper proposes a problem formulation that explicitly considers nonuniform unavailabilities and all backup detection levels. The resulting sensor placement problem is a large-scale mixed-integer nonlinear programming (MINLP) problem that requires a tailored solution approach for efficient solution. We have developed a multitree method which depends on iteratively solving a sequence of upper-bounding master problems and lower-bounding subproblems. The tailored global solution strategy is tested on a real data problem and the encouraging numerical results indicate that our solution framework is promising in solving sensor placement problems. This study was selected for the special issue in JLPPI from the 2016 International Symposium of the MKO Process Safety Center.

47 OTHER INSTRUMENTATION↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discriminating between a stochastic gravitational wave background and instrument noise

The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive ''null channels'' formed from particular combinations of the time delay interferometry, and derive a new combination that maintains this insensitivity for unequal arm-length detectors. We show that, in the absence of astrophysical foregrounds, LISA could detect signals with energy densities as low as {Omega}{sub gw}=6x10{sup -13} with just one month of data. We describe an end-to-end Bayesian analysis pipeline that is able to search for, characterize and assign confidence levels for the detection of a stochastic gravitational wave background, and demonstrate the effectiveness of this approach using simulated data from the third round of Mock LISA Data Challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Assessment of OSIRIS-REx OVIRS Cryogenic Instrument During Flight System TVAC Test and in Flight

The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) Visible and Infrared Spectrometer (OVIRS) is a cryogenic instrument. At the Outbound Cruise nominal spacecraft attitude, sunlight impinges on several multilayer insulation blankets on the forward deck. It is reflected or scattered to other components on the deck. This solar illumination adds heat load to the OVIRS, and causes its detector temperature to exceed the 105K maximum operating allowable flight temperature limit by 0.8K. During the flight system thermal vacuum test, the solar simulator beam reflected or scattered from the test fixtures to the OVIRS added non-flight heat load. The detector temperature was 9K warmer than that in flight. At those temperatures, the science data was acceptable, despite its quality was not as high as that of 105K or colder.

"OSIRIS-REx; OVIRS; cryogenic instrument; parasiti↗

Advanced assessment of beam-induced background at a muon collider

Renewed international interest in muon colliders motivates the continued investigation of the impacts of beam-induced background on detector performance. This continues the effort initiated by the Muon Accelerator Program and carried out until 2017. The beam-induced background from muon decays directly impacts detector performance and must be mitigated by optimizing the overall machine design, with particular attention paid to the machine detector interface region. In order to produce beam-induced background events and to study their characteristics in coordination with the collider optimization, a flexible simulation approach is needed. To achieve this goal we have chosen to utilize the combination of LineBuilder and Monte Carlo FLUKA codes. We report the results of beam-induced background studies with these tools obtained for a 1.5 TeV center of mass energy collider configuration. Good agreement with previous simulations using the MARS15 code demonstrates that our choice of tools meet the accuracy and performance requirements to perform future optimization studies on muon collider designs.

43 PARTICLE ACCELERATORS↗

WE-EF-207-06: Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio

Purpose: To determine the spatial distribution of x-ray scatter and scatter-to-primary ratio (SPR) in projections during cone-beam breast CT (CBBCT) with laterally-shifted detector that results in coronal (fan-angle) truncation. Methods: We hypothesized that CBBCT with coronal truncation would lower SPR due to reduction in irradiated breast volume, and that the location of maximum x-ray scatter fluence (scatter-peak) in the detector plane can be determined from the ratio of irradiated-to-total breast volume, breast dimensions and system geometry. Monte Carlo simulations (GEANT4) reflecting a prototype CBBCT system were used to record the position-dependent primary and scatter x-ray photon fluence incident on the detector without coronal truncation (full fan-angle, 2f=24-degrees) and with coronal truncation (fan-angle, f+ f=12+2.7-degrees). Semi-ellipsoidal breasts (10/14/18-cm diameter, chest-wall to nipple length: 0.75xdiameter, 2%/14%/100% fibroglandular content) aligned with the axis-of-rotation (AOR) were modeled. Mono-energy photons were simulated and weighted for 2 spectra (49kVp, 1.4-mm Al HVL; 60kVp, 3.76-mm Al HVL). In addition to SPR, the scatter maps were analyzed to identify the location of the scatter-peak. Results: For CBBCT without fan-angle truncation, the scatter-peaks were aligned with the projection of the AOR onto the detector for all breasts. With truncated fan-beam, the scatter-peaks were laterally-shifted from the projection of the AOR along the fan-angle direction by 14/38/70-pixels for 10/14/18-cm diameter breasts. The corresponding theoretical shifts were 14.8/39.7/68-pixels (p=0.47, 2-tailed paired-ratio t-test). Along the cone-angle, the shift in scatter-peaks between truncated and full-fan angle CBBCT were 2/2/4 -pixels for 10/14/18-cm diameter breasts. CBBCT with fan-angle truncation reduced SPR by 14/22/28% for 10/14/18-cm diameter breasts. 60kVp reduced SPR by 21–25% compared to 49kVp. Peak SPR for CBBCT with fan-angle truncation (60kVp) were 0.09/0.25/0.73 for 10/14/18-cm diameter breasts. Conclusion: CBBCT with laterally-shifted detector geometry and with appropriate kVp/beam quality reduces SPR. If residual scatter needs correction, the location corresponding to scatter-peak can be analytically computed. This work was supported in part by NIH R01 CA128906. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Validation of a Monte Carlo HPGe detector model against irradiated foil gamma-ray spectroscopy measurements

In this study, a high-purity germanium detector Monte Carlo model was evaluated for its ability to predict activation product ratios in Fe, Cr, Ni, and stainless-steel foils. To evaluate the model, activation product ratios calculated from simulated gamma-ray spectra were compared against those from experiment measurements. Analysis shows that the detector model accurately predicts activation product ratios within 10% when free of interferences. Presence of a shield chamber greatly increases computation time, but does not provide any quantitative advantages. Overall, the model is useful for predicting activation product ratios and experiment planning.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of the Prompt Radiation Shielding Design of the ESS Accelerator

Fermilab will perform prompt radiation and shielding verification studies for the European Spallation Source ERIC (ESS) accelerator tunnel and existing penetration layouts using the latest information on the beam line and existing models of magnets and cryomodules. The input information about the assumptions, geometry layout, etc. will be provided by the Safety Group (accelerator division, ESS). The MEDT department of the Accelerator Division, Fermilab will provide the results of the studies. MARS15, a Fermilab a multi-purpose Monte-Carlo code developed since 1974, is at the heart of this effort. MARS15 is used for detailed simulation of hadronic and electromagnetic cascades in an arbitrary 3-D geometry of shielding, accelerator, detector and spacecraft components with energy ranging from a fraction of an electronvolt to 100 TeV. This work will provide additional validation of recent additions to the physical models in the code, including the code capabilities to simulate cascades and generate a variety of results in complex media.

43 PARTICLE ACCELERATORS↗

TU-F-18A-07: To Explore the More Realistic Energy Responses of the In-Depth Photon Counting Detectors

Purpose: We study the effect of the secondary photon events on modeling the energy response functions of the In-depth photon counting X-ray detectors (PCXD) and the potential impact of the spectral distortion on material decompositions. Methods: Square-shape wafers of three potential PCXD materials were constructed (5-by-20-by-30 mm{sup 3} for Si, 4-by-20-by-5 mm{sup 3} for GaAs and 4-by-20-by-3 mm{sup 3} for CdTe), with pixel size of 5-by-4 mm{sup 2} for Si and 5-by-5 mm{sup 2} for GaAs and CdTe. The depth direction (z-direction) was segmented into 5 layers with exponentially increasing thicknesses of each layer. X-rays from 10keV to 120keV with 20000 photons per keV bin was simulated to characterize the energy response function of each PCXD using Geant4. Secondary photons events were recorded and we omitted the photons exiting the detector. The Energy Response Functions (ERFs) from the Monte Carlo (MC) simulations were compared with those from a semi-ideal model developed earlier. Results: For Si, detection of secondary events in the center detector were minimal due to the long aspect ratio of the detector, which results in the agreement between the theoretical prediction and the MC simulation with and without the secondary photons. For CdTe, the secondary photons captured by the center pixel were important, leading to obvious disagreement between the analytical and the simulated ERF. After correction for secondary events, the two curves were more similar except for the escape peaks which are not correctly portrayed by the semi-ideal model. For GaAs, the behavior is in between Si and CdTe. Conclusion: Given the complexity of the In-Depth PCXD's geometry, the uniform semi-ideal model does not fully characterize the ERF at each layer. Therefore, more realistic models need to be explored for better modeling of the spectral distortion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study of Charge Propagation and Quantification of Noise Within the SuperCDMS Detector

This paper discuses two projects that were designed around the SuperCDMS experiment. The first is an attempt to understand the SuperCDMS simulation that was designed in the Matlab environment. The tests that were conducted were designed to study how electron and hole propagation is effected by the initial event location and the charge bias within the detector. The second experiment was an attempt to systematically quantify the level of noise produced within the SuperCDMS detectors by the dilution refrigerator. The results show only initial findings and no conclusive results were obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conceptual design of the ITER fast-ion loss detector

A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗