Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Relating the baryon asymmetry to the thermal relic dark matter density

We present a generic framework, baryomorphosis, which modifies the baryon asymmetry to be naturally of the order of a typical thermal relic weakly interacting massive particle (WIMP) density. We consider a simple scalar-based model to show how this is possible. This model introduces a sector in which a large initial baryon asymmetry is injected into particles ('annihilons'), {phi}{sub B}, {phi}-circumflex{sub B}, of mass {approx}100 GeV-1 TeV. {phi}{sub B{phi}}-circumflex{sub B} annihilations convert the initial {phi}{sub B}, {phi}-circumflex{sub B} asymmetry to a final asymmetry with a thermal relic WIMP-like density. This subsequently decays to a conventional baryon asymmetry whose magnitude is naturally related to the density of thermal relic WIMP dark matter. In this way the two coincidences of baryons and dark matter, i.e. why their densities are similar to each other and why they are both similar to a WIMP thermal relic density (the 'WIMP miracle'), may be understood. The model may be tested by the production of annihilons at colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnosing ions and neutrals via n=2 excited hydrogen atoms in plasmas with high electron density and low electron temperature

Ion and neutral parameters are determined in the high electron density, magnetized, hydrogen plasma beam of an ITER divertor relevant plasma via measurements of the n=2 excited neutrals. Ion rotation velocity (up to 7 km/s) and temperature (2-3 eV{approx}T{sub e}) are obtained from analysis of H{alpha} spectra measured close to the plasma source. The methodology for neutral density determination is explained whereby measurements in the linear plasma beam of Pilot-PSI are compared to modeling. Ground-state atomic densities are obtained via the production rate of n=2 and the optical thickness of the Lyman-{alpha} transition (escape factor {approx}0.6) and yield an ionization degree >85% and dissociation degree in the residual gas of {approx}4%. A 30% proportion of molecules with a rovibrational excitation of more than 2 eV is deduced from the production rate of n=2 atoms. This proportion increases by more than a factor of 4 for a doubling of the electron density in the transition to ITER divertor relevant electron densities, probably because of a large increase in the production and confinement of ground-state neutrals. Measurements are made using laser-induced fluorescence (LIF) and absorption, the suitability of which are evaluated as diagnostics for this plasma regime. Absorption is found to have a much better sensitivity than LIF, mainly owing to competition with background emission.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamical Structure Factor and Spin-Density Separation for a Weakly Interacting Two-Component Bose Gas

We show that spin-density separation in a Bose gas is not restricted to 1D but also occurs in higher dimensions. The ratio ({alpha}) of the intraspecies atom-atom interaction strength to the interspecies interaction strength strongly influences the dynamics of spin-density separation and the elementary excitations. The density wave is phononlike for all values of {alpha}. For {alpha}<1, the spin wave is also phononlike. The spin waves have a quadratic dispersion in the {alpha}=1 coupling regime, while in the phase separated regime ({alpha}>1) the spin waves are found to be damped. The dynamical structure factor reveals two distinct peaks corresponding to the density and spin waves for {alpha}{<=}1. For {alpha}>1 there is only one dynamical structure factor peak corresponding to the density wave.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Further steps toward the next generation of covariant energy density functionals

The present study aims at further development of covariant energy density functionals (CEDFs) towards more accurate description of binding energies across the nuclear chart. Infinite basis corrections to binding energies in the fermionic and bosonic sectors of the covariant density functional theory are taken into account in the fitting protocol within the covariant density functional theory. In addition, total electron binding energies are used in the conversion of atomic binding energies into nuclear ones. Their dependence on neutron excess is investigated across the nuclear chart within the atomic approach. Furthermore, these factors were disregarded in the previous generation of covariant energy density functionals, but their omission leads to substantial global calculation errors for physical quantities of interest. For example, these errors for binding energies are of the order of 0.8 MeV or higher for the three major classes of covariant energy density functionals.

Binding energy & masses↗

Investigating the Impact of Thickness, Calendering and Channel Structures of Printed Electrodes on the Energy Density of LIBs - 3D Simulation and Validation

Current lithium ion batteries (LIBs) are expensive and bulky, limited by relatively low charging rates. To increase the rate of charging and reduce weight, thin electrodes with high energy density are required. The increase in energy density can be achieved by several techniques including boosting electrolyte transport, high loading/utilization of active material, employing high conductive electrolytes and electrodes with advanced architectures, and increasing cell temperature. In this paper, a 3D physics-based electrochemical model of LIBs is developed in COMSOL simulation software for different thickness, calendering steps as well as channel structures (conical, cylindrical) to optimize the electrode design and in turn maximize volumetric energy density. The simulation results demonstrated that calendering the electrodes with high initial porosity increases the volumetric energy density of the cell. In addition, cylindrical channel structures with relatively lower edge-to-edge distance also results in increased volumetric energy density. The simulation results of the 3D model was validated by comparing it with experimental results.

improving volumetric energy density↗

Additive manufacturing of high‐density silicon carbide ceramics through post‐processing spark plasma sintering

This research advances the field of additive manufacturing (AM) of silicon carbide (SiC) ceramics by integrating spark plasma sintering (SPS) to enhance material density, mechanical strength, and thermal properties. Traditional AM techniques struggle to achieve the high‐density SiC required for demanding applications, such as aerospace engineering, where high thermal conductivity and mechanical strength are paramount. Here, our study addresses these challenges by incorporating SPS as a post‐processing step, achieving near‐theoretical maximum densities and significantly reducing porosity, thereby resulting in outstanding thermal conductivity in SiC ceramics. We developed a specialized SiC ink optimized for 3D printing, ensuring structural integrity after deposition through tailored rheological properties. The application of SPS facilitates rapid, uniform sintering, essential for attaining superior density, mechanical properties, and thermal performance. Our experimental results, confirmed through scanning electron microscopy analysis, demonstrate significant microstructural properties, mechanical strength, and thermal conductivity, showcasing the effectiveness of integrating SPS in AM processes. This innovative approach not only expands the capabilities of AM in producing complex, high‐density ceramic structures but also broadens the potential applications of SiC in demanding environments.

36 MATERIALS SCIENCE↗

Effect of bias application to plasma density in weakly magnetized inductively coupled plasma

Independent control of the ion flux and energy can be achieved in a dual frequency inductively coupled plasma (ICP) system. Typically, the plasma density is controlled by the high-frequency antenna radio-frequency (RF) power and the ion energy is controlled by the low-frequency bias RF power. Increasing the bias power has been known to cause a decrease in the plasma density in capacitively coupled discharge systems as well as in ICP systems. However, an applied axial magnetic field was found to sustain or increase the plasma density as bias power is increased. Measurements show higher electron temperatures but lower plasma densities are obtained in ordinary ICP systems than in magnetized ICP systems under the same neutral gas pressure and RF power levels. Explanations for the difference in the behavior of plasma density with increasing bias power are given in terms of the difference in the heating mechanism in ordinary unmagnetized and magnetized ICP systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distribution of ion current density on a rotating spherical cap substrate during ion-assisted deposition

The uniformity of ion density is critical for applications relying on the ion assisted deposition technique for the fabrication of the high quality thin films. The authors propose and describe here a method allowing one to calculate the ion density distribution on spherical substrate holders under stationary and rotating conditions for different positions of the ion source. The ion beam shape was approximated by a cos{sup n} function, and the ion current density was represented by a function inversely proportional to the distance from the ion source in accordance with our experimental results. As an example, a calculation of the current density distribution on the spherical cap substrate was performed for a broad beam ion source operated with an anode current of 3 A. The authors propose an approach for process optimization with respect to the ion source position and its inclination, in terms of uniformity and absolute value of the ion current density.

42 ENGINEERING↗

Uncertainty Quantification Techniques for Population Density Estimates Derived from Sparse Open Source Data

The Population Density Tables (PDT) project at the Oak Ridge National Laboratory (www.ornl.gov) is developing population density estimates for specific human activities under normal patterns of life based largely on information available in open source. Currently, activity based density estimates are based on simple summary data statistics such as range and mean. Researchers are interested in improving activity estimation and uncertainty quantification by adopting a Bayesian framework that considers both data and sociocultural knowledge. Under a Bayesian approach knowledge about population density may be encoded through the process of expert elicitation. Due to the scale of the PDT effort which considers over 250 countries, spans 40 human activity categories, and includes numerous contributors, an elicitation tool is required that can be operationalized within an enterprise data collection and reporting system. Such a method would ideally require that the contributor have minimal statistical knowledge, require minimal input by a statistician or facilitator, consider human difficulties in expressing qualitative knowledge in a quantitative setting, and provide methods by which the contributor can appraise whether their understanding and associated uncertainty was well captured. This paper introduces an algorithm that transforms answers to simple, non-statistical questions into a bivariate Gaussian distribution as the prior for the Beta distribution. Based on geometric properties of the Beta distribution parameter feasibility space and the bivariate Gaussian distribution, an automated method for encoding is developed that responds to these challenging enterprise requirements. Though created within the context of population density, this approach may be applicable to a wide array of problem domains requiring informative priors for the Beta distribution.

Bayesian↗

Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography

The goal of this study was to evaluate the improvement in electron density measurement and metal artifact reduction using orthovoltage computed tomography (OVCT) imaging compared with conventional kilovoltage CT (KVCT). For this study, a bench-top system was constructed with adjustable x-ray tube voltage up to 320 kVp. A commercial tissue-characterization phantom loaded with inserts of various human tissue substitutes was imaged using 125 kVp (KVCT) and 320 kVp (OVCT) x rays. Stoichiometric calibration was performed for both KVCT and OVCT imaging using the Schneider method. The metal inserts--titanium rods and aluminum rods--were used to study the impact of metal artifacts on the electron-density measurements both inside and outside the metal inserts. It was found that the relationships between Hounsfield units and relative electron densities (to water) were more predictable for OVCT than KVCT. Unlike KVCT, the stoichiometric calibration for OVCT was insensitive to the use of tissue substitutes for direct electron density calibration. OVCT was found to significantly reduce metal streak artifacts. Errors in electron-density measurements within uniform tissue substitutes were reduced from 42% (maximum) and 18% (root-mean-square) in KVCT to 12% and 2% in OVCT, respectively. Improvements were also observed inside the metal implants. For the detectors optimized for KVCT, the imaging dose is almost doubled for OVCT for the image quality comparable to KVCT. OVCT may be a good option for high-precision radiotherapy treatment planning, especially for patients with metal implants and especially for charged particle therapy, such as proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed. This work was supported in part by NIH R01 CA0096679.

60 APPLIED LIFE SCIENCES↗

Precise model approximation of JINR (Dubna) data on nuclear level densities in the region 40 {<=} A {<=} 200 below B{sub n}

The experimental nuclear level density below the neutron binding energy B{sub n} in the mass region 40 {<=} A {<=} 200 is approximated to a high precision on the basis of the Strutinsky model combined with the assumption that the coefficient of collective enhancement of the level density for a given number of excited quasiparticles decreases exponentially with increasing excitation energy. This combination of model concepts makes it possible to reproduce faithfully not only the general trend revealed by the method developed at the Joint Institute for Nuclear Research (JINR, Dubna) in the change in the level density with increasing excitation energy in any nuclei but also the fine structure of this level density. Realistic experimental information about the change in the relationship between the densities of quasiparticle- and vibrational-type states was obtained for the first time for any nuclei virtually up to the neutron binding energy B{sub n}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of plasma density from data on the ion current to cylindrical and planar probes

To improve probe methods of plasma diagnostics, special probe measurements were performed and numerical models describing ion transport to a probe with allowance for collisions were developed. The current–voltage characteristics of cylindrical and planar probes were measured in an RF capacitive discharge in argon at a frequency of 81 MHz and plasma densities of 10{sup 10}–10{sup 11} cm{sup –3}, typical of modern RF reactors. 1D and 2D numerical models based on the particle-in-cell method with Monte Carlo collisions for simulating ion motion and the Boltzmann equilibrium for electrons are developed to describe current collection by a probe. The models were used to find the plasma density from the ion part of the current–voltage characteristic, study the effect of ion collisions, and verify simplified approaches to determining the plasma density. A 1D hydrodynamic model of the ion current to a cylindrical probe with allowance for ion collisions is proposed. For a planar probe, a method to determine the plasma density from the averaged numerical results is developed. A comparative analysis of different approaches to calculating the plasma density from the ion current to a probe is performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operation of a semiconductor opening switch at the pumping time of a microsecond and low current density

The mechanism of operation of a semiconductor opening switch (a SOS diode) at the forward-pumping time of a microsecond and low current density was studied. The current's cutoff time shorter than 10 ns at the voltage across the SOS diode as high as 80 kV was obtained experimentally at the reverse-pumping time {approx}200 ns and the cutoff-current density of about 120 A/cm{sup 2}. These are the results of numerical simulation of processes in the dynamics of the electron-hole plasma in the diode at the stages of pumping and current cutoff. It is shown that the stage of the current cutoff is similar to the conditions of the SOS effect observed at a high current density and is also related to motion of the concentration front of excess plasma along the heavily doped p-type region of the structure. In spite of the low density of current in the course of its cutoff, the switching process takes several nanoseconds. The reason is that the low current density is compensated by a low concentration of the excess plasma at the front, which retains the high velocity of motion of this front at the stage of the current cutoff.

36 MATERIALS SCIENCE↗

Experimental level densities of atomic nuclei

It is almost 80 years since Hans Bethe described the level density as a non-interacting gas of protons and neutrons. In all these years, experimental data were interpreted within this picture of a fermionic gas. However, the renewed interest of measuring level density using various techniques calls for a revision of this description. In particular, the wealth of nuclear level densities measured with the Oslo method favors the constant-temperature level density over the Fermi-gas picture. Furthermore, trom the basis of experimental data, we demonstrate that nuclei exhibit a constant-temperature level density behavior for all mass regions and at least up to the neutron threshold.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soil bulk density and texture data collected during field survey associated with NEON AOP survey, East River, CO 2018

The purpose of soil core sampling was to determine soil bulk density, volumetric water content, and soil texture across the sites that were sampled in association with the National Ecological Observatory Network's Airborne Observation Platform (NEON AOP) in 2018. Soil cores were collected from surface (2.5-7.5 cm) and subsurface (50-55cm) depths at sampling sites across East River, Washington Gulch, Slate River, and Coal Creek watersheds in Gunnison, Colorado during the summer of 2018. Surface samples were weighed for determination of soil water content prior to dry down for bulk density calculations. For all samples, we measured dry weight and weight of < 2mm fraction and conducted soil textural analysis. We provide metadata for the samples, raw data files, python code that was used to calculate bulk density, water content, and texture fraction densities from primary datasets, and a final csv file with the calculated soil bulk density, volumetric water content, and soil texture data. Additional associated site metadata and vegetation fractional cover information can be found in the associated data release.

54 ENVIRONMENTAL SCIENCES↗

Assessment of an ORION-Based Experimental Platform for Measuring the Opacity of High-Temperature and High-Density Plasma

The following provides an assessment of an experimental platform based on the ORION laser at AWE Aldermasten, England, for measuring the opacity of high-temperature and high-density LTE plasmas. The specific points addressed are (1) the range of electron density and temperature that can be achieved with short-pulse beams alone, as well as (2) by means of compression with a long-pulse beam; (3) the accuracy with which electron density, electron temperature, and absolute emissivity can be measured; (4) the use of pulse shaping to increase the sample density to above solid density; (5) the effect that target materials and target design have on maintaining spatial uniformity of the sample, and (6) the need for additional diagnostics to produce and characterize samples for decisive measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗