Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DYNAMIC PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Bragg coherent diffraction imaging by simultaneous reconstruction of multiple diffraction peaks

Bragg coherent diffractive imaging (BCDI) is a non-invasive microscopy technique that can visualize the morphology and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. While BCDI has been successfully applied in various studies of materials, it is less successful for highly-strained crystals. Specifically, it is difficult to correctly reconstruct the electron density of a highly-strained object using conventional phase retrieval algorithms. Although various algorithms have been developed to overcome this challenge, most of them require a priori knowledge that is not always available in practice. Here we report on a new phase retrieval workflow that can invert diffraction patterns from multiple Bragg peaks simultaneously. The new workflow is explored via simulated diffraction from crystals with various strain conditions. Furthermore, reconstructions from the new workflow consistently demonstrate more accurate electron density maps, in comparison with the conventional method. For highly-strained crystals, the new workflow improves the reliability and consistency of BCDI phase retrieval significantly.

36 MATERIALS SCIENCE↗

Micropinch formation dynamics in X pinches

High temporal resolution x-ray streak camera studies of micropinch formation in Cu hybrid x pinches reveal key plasma conditions. Analysis of Ne-like Cu lines indicate an average electron temperature of about 200 eV and 4.5×10 28 m -3 electron density. Here, the spectra suggest that the electron temperature jumps to about 1 keV, inferred from the continuum and the postcontinuum line emission that includes Li-like Cu lines. There is no sign of a rapid temperature change or a substantial surge in radiation emission during the 200 ps precontinuum x-ray burst, suggesting that the radiative collapse process does not play a major role in micropinch formation. Two-dimensional extended Magnetohydrodynamic (MHD) simulations, coupled to a collisional-radiative spectral analysis code, suggest the significance of the rapid radial implosion of high-temperature, low-density plasma, the axial outflow, and the dynamic plasma pressure in micropinch formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Support Design for Mines Exposed to Rockburst Hazard

One of the approaches to reducing aftereffects of rock bursts is the dynamic support capable to stand strong dynamic rock pressure events in the form of seismic vibration and failure of adjacent rock mass. The article describes the support design procedure in use in hard mineral mines exposed to rockburst hazard. Different types of rock bolting and surface support are discussed from the viewpoint of energy absorption and yielding.

42 ENGINEERING↗

Modeling, Analysis and Simulation of Multiscale Preferential Flow

The research agenda of this project are: (1) Modeling of preferential transport from mesoscale to macroscale; (2) Modeling of fast flow in narrow fractures in porous media; (3) Pseudo-parabolic Models of Dynamic Capillary Pressure; (4) Adaptive computational upscaling of flow with inertia from porescale to mesoscale; (5) Adaptive modeling of nonlinear coupled systems; and (6) Adaptive modeling and a-posteriori estimators for coupled systems with heterogeneous data.

58 GEOSCIENCES↗

Subgrid-Scale Mixing in Climate Models: A Novel Look at Diffusion, Accuracy, Stability and Climate Sensitivity

This project focuses on evaluating the role of subgrid-scale dissipation in the dynamical core of atmospheric models. All dynamical cores of atmospheric general circulation models (GCMs) employ some form of subgrid-scale dissipation, either explicitly specified or inherent in the chosen numerical schemes. The dissipation processes are needed to keep the simulation stable or to satisfy important physical properties, and the hope is that they capture and mimic in some poorly understood way the true processes at the unresolved subgrid scale. There is no physical basis that such dissipation can accomplish this. We originally posed a set of numerical test cases chosen or designed to isolate the role of the filters and fixers on both the dynamical variables (pressure, temperature, velocity, vorticity) and trace constituents. From these test case results, we synthesize the information to determine the impact of the subgrid-scale assumptions on weather and climate models.

54 ENVIRONMENTAL SCIENCES↗

Local Electronic And Dielectric Properties at Nanosized Interfaces (Final Report)

The behavior of grain boundaries and interfaces has been a focus of fundamental research for decades because variations of structure and composition at interfaces dictate mechanical, electrical, optical and dielectric properties in solids. Similarly, the consequence of atomic and electronic structures of surfaces to chemical and physical interactions are critical due to their implications to catalysis and device fabrication. Increasing fundamental understanding of surfaces and interfaces has materially advanced technologies that directly bear on energy considerations. Currently, exciting developments in materials processing are enabling creative new electrical, optical and chemical device configurations. Controlled synthesis of nanoparticles, semiconducting nanowires and nanorods, optical quantum dots, etc. along with a range of strategies for assembling and patterning nanostructures portend the viability of new devices that have the potential to significantly impact the energy landscape. As devices become smaller the impact of interfaces and surfaces grows geometrically. As with other nanoscale phenomena, small interfaces do not exhibit the same properties as do large interfaces. The size dependence of interface properties had not been explored and understanding at the most fundamental level is necessary to the advancement of nanostructured devices. An equally important factor in the behavior of interfaces in devices is the ability to examine the interfaces under realistic conditions. For example, interfaces and boundaries dictate the behavior of oxide fuel cells which operate at extremely high temperatures in dynamic high pressure chemical environments. These conditions preclude the characterization of local properties during fuel cell operation. The objective of this research was to determine the size and interface atomic structure dependence of the electronic properties of metal/oxide interfaces using model materials systems of noble metals on SrTiO 3 surfaces; and to develop experimental techniques to probe spatially localized properties under extreme conditions. The outcomes of this research summarized in more detail below include; Discovery of the presence of multiple size dependent transport mechanisms at nanoscale interfaces and determination of the critical size parameter associated with a transition from one to another; Determination of the effect of interface atomic structure and electronic structure at nanoscale interfaces on electronic transport across the interfaces, in particular the role of states associated with under coordinated cations enabling resonant tunneling and/or band bending; Discovery and characterization of size dependent resistive switching at nanoscale interfaces; These advances required the development of a process to produce nanosized contacts with controlled interface orientation over sizes (diameters) ranging from 20-500nm and the determination of the mechanical and electrical parameters for robust and accurate measurement of frequency dependent properties of nanoscale interfaces; Invention of a chamber that enables in situ scanning probe microscopy and spectroscopy at high temperature and reactive gas environments; and First measurement of interface properties in an operating solid oxide fuel cell, quantifying the local electrical potentials and energies associated with two reaction mechanisms.

36 MATERIALS SCIENCE↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Third Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new capability for investigating the structure and dynamics of liquids at high pressures

Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an optically accessible continuous wave Rotating Detonation Engine

In this study we investigate the modes of operation, dynamics and pressure oscillation statistics of a 6 inch RDE operated with axial air slot injection and rear-facing angled fuel injection from a contraction (pintle injection). The RDE exhibits two primary modes of operation for this injection scheme, termed detonation and deflagration modes. Using high speed static pressure measurements a variety of wave pressure statistics are constructed from both operation modes over a range of air mass fluxes and equivalence ratios. The condensed information is then used to contrast differences in the modes of operation as well as to assess the behavior of the primary mode of interest, the detonation mode.

Chacon, Fabian↗

Some effects of vibration and rotation on the drift of gyroscopic instruments

It is the purpose of this paper to describe and indicate possible analytical approaches to some of the most significant mechanisms by which vibration induced drifts may occur, and to indicate, where possible, some means of alleviating them. In all cases we will not consider gimbal bearing friction, mass unbalance or other sources of steady extraneous torques on the gyro rotor. The mechanisms to be discussed are: Non-Newtonian viscosity in single degree of freedom (SDF) integrating-rate gyros, nonisoelasticity in SDF gyros, noncommutative effects for SDF stabilized platform, gimbal inertia effects, 2 DF gyros, and spin axis torque coupling in 2 DF gyros. High-frequency elastic resonances are not discussed explicitly in detail, because they are a more familiar problem and one which depends strongly on the details of each particular gyro design.

Viscous Torque↗

On the steady flow of gas from the nuclei of Seyfert galaxies

Heating of gas energy released during explosive events produces hot winds in Seyfert nuclei. Steady-state solutions indicate that supersonic velocities up to about 800 km per sec are obtainable. Lyman continuum radiation emitted by the wind ionizes and maintains temperature of cooler gas clouds seen in emission, and dominates energy losses during early stages of expansion. A study of stability of the thermal equilibrium state leads to a two-component model: a hot stable phase (the wind), in pressure equilibrium with a cooler stable phase (clouds). Extreme variations in cloud electron densities are a consequence of the steep decrease with radius of external pressure. Cloud dynamics are related to the radius of formation and internal parameters. Permitted lines of H are emitted by high-density clouds formed at the base of the wind, while forbidden lines arise in radially moving clouds, produced throughout the wind.

Wolfe, A. M.↗