Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a prototype Open-close positron emission tomography system

We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Roadmap on electronic structure codes in the exascale era

Electronic structure calculations have been instrumental in providing many important insights into a range of physical and chemical properties of various molecular and solid-state systems. Their importance to various fields, including materials science, chemical sciences, computational chemistry and device physics, is underscored by the large fraction of available public supercomputing resources devoted to these calculations. As we enter the exascale era, exciting new opportunities to increase simulation numbers, sizes, and accuracies present themselves. In order to realize these promises, the community of electronic structure software developers will however first have to tackle a number of challenges pertaining to the efficient use of new architectures that will rely heavily on massive parallelism and hardware accelerators. This roadmap provides a broad overview of the state-of-the-art in electronic structure calculations and of the various new directions being pursued by the community. It covers 14 electronic structure codes, presenting their current status, their development priorities over the next five years, and their plans towards tackling the challenges and leveraging the opportunities presented by the advent of exascale computing.

36 MATERIALS SCIENCE↗

Tensor Minkowski Functionals: first application to the CMB

Tensor Minkowski Functionals (TMFs) are tensor generalizations of the usual Minkowski Functionals which are scalar quantities. We introduce them here for use in cosmological analysis, in particular to analyze the Cosmic Microwave Background (CMB) radiation. They encapsulate information about the shapes of structures and the orientation of distributions of structures. We focus on one of the TMFs, namely W {sub 2}{sup 1,1}, which is the (1,1) rank tensor generalization of the genus. The ratio of the eigenvalues of the average of W {sub 2}{sup 1,1} over all structures, α, encodes the net orientation of the structures; and the average of the ratios of the eigenvalues of W {sub 2}{sup 1,1} for each structure, β, encodes the net intrinsic anisotropy of the structures. We have developed a code that computes W {sub 2}{sup 1,1}, and from it α and β, for a set of structures on the 2-dimensional Euclidean plane. We use it to compute α and β as functions of chosen threshold levels for simulated Gaussian and isotropic CMB temperature and E mode fields. We obtain the value of α to be one for both temperature and E mode, which means that we recover the statistical isotropy of density fluctuations that we input in the simulations. We find that the standard ΛCDM model predicts a charateristic shape of β for temperature and E mode as a function of the threshold, and the average over thresholds is β∼ 0.62 for temperature and β∼ 0.63 for E mode. Accurate measurements of α and β can be used to test the standard model of cosmology and to search for deviations from it. For this purpose we compute α and β for temperature and E mode data of various data sets from PLANCK mission. We compare the values measured from observed data with those obtained from simulations to which instrument beam and noise characteristics of the 44GHz frequency channel have been added (which are provided as part of the PLANCK data release). We find very good agreement of β and α between all PLANCK temperature data sets with ΛCDM expectations. E mode data show good agreement for β but α for all data sets deviate from ΛCDM predictions higher than 3−σ. It is most likely that the deviations are probing the anisotropy of the noise field and beam characteristics of the detector rather than the true E mode signal since for 44GHz the signal-to-noise ratio is well below one. This will be further investigated after the full PLANCK data becomes publicly available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exascale Workload Characterization and Architecture Implications

We use a hybrid methodology based on binary instrumentation and performance counters to characterize a set of proxy applications (mini-apps and PETSc applications) representative of a broad range of scientific applications (and particularly DOE's future high performance computing workloads). From this empirical basis, we create statistical models that extrapolate application properties (instruction mix, memory size, and memory bandwidth) as a function of problem size. We validate them and project the first quantitative characterization of an exascale computing workload. Finally, the exascale workload is used to evaluate a radical new exascale architecture, stacked DRAM with processor under memory (PUM). Of the two projections, one shows major potential benefits in using PUM. However, the second, more conservative projection suggests that only a small number of exascale applications are likely to be memory-bandwidth limited, but even these are fundamentally memory-capacity limited.

Balaprakash, Prasanna↗

Application of Multivariate Data Analysis Techniques for the Portable Isotopic Neutron Spectroscopy system

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical compounds non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS systems have been successfully deployed around the world to identify chemical munitions and containers. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with the probabilistic decision tree (PDT). Gamma-ray peak analyses, however, require knowledge of pre-selected gamma-ray peaks whose energies, intensities, and origins are well studied, and some peaks might be excluded from the decision making processes due to lack of current nuclear data. In contrast, Multivariate Analysis (MVA) treats a whole gamma-ray spectrum as a collection of multiple variables or a pattern. The effectiveness of chemical identification algorithm is determined by the availability of a wide range of data to train an algorithm to identify chemical fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to combine such a database with the principle of multivariate statistics. Therefore, in parallel with the current decision tree algorithm, an MVA-based chemical identification algorithm was developed as an independent verification of the current results. The Principal Component Analysis (PCA) method was adopted to build an MVA-based identification algorithm, using the collected field data to refine and validate the algorithm. A benchmarking study of the MVA-based algorithm’s performance was conducted alongside the current algorithm, with the results presented and discussed in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-Based Detection of Radioactive Contraband for Harbor Defense Incorporating Compton Scattering Physics

The detection of radioactive contraband is a critical problem is maintaining national security for any country. Photon emissions from threat materials challenge both detection and measurement technologies especially when concealed by various types of shielding complicating the transport physics significantly. This problem becomes especially important when ships are intercepted by U.S. Coast Guard harbor patrols searching for contraband. The development of a sequential model-based processor that captures both the underlying transport physics of gamma-ray emissions including Compton scattering and the measurement of photon energies offers a physics-based approach to attack this challenging problem. The inclusion of a basic radionuclide representation of absorbed/scattered photons at a given energy along with interarrival times is used to extract the physics information available from the noisy measurements portable radiation detection systems used to interdict contraband. It is shown that this physics representation can incorporated scattering physics leading to an 'extended' model-based structure that can be used to develop an effective sequential detection technique. The resulting model-based processor is shown to perform quite well based on data obtained from a controlled experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-temperature Superconducting Interconnects for Ultra-low Temperature, High-field Environments

Coplanar (with the ground) 20 cm long waveguides are manufactured from the YBCO-on-Kapton material. We investigate the effect of parasitic ground plane resonances on the performance of these waveguides. Here, it is concluded that dense rows stitching vias are essential for isolating the lines to a level below 60 dB at 6 GHz. We demonstrate a metalized via technology that is compatible with both the traditional Flexible Printed Circuit (FPC) process and the epitaxial YBCO material. Stitching via fence with the via period 10 mm is shown as effective in suppressing parasitic resonances at 77 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems

Purpose: To develop and implement a failure mode and effect analysis (FMEA)-based commissioning and quality assurance framework for dynamic multileaf collimator (DMLC) tumor tracking systems. Methods: A systematic failure mode and effect analysis was performed for a prototype real-time tumor tracking system that uses implanted electromagnetic transponders for tumor position monitoring and a DMLC for real-time beam adaptation. A detailed process tree of DMLC tracking delivery was created and potential tracking-specific failure modes were identified. For each failure mode, a risk probability number (RPN) was calculated from the product of the probability of occurrence, the severity of effect, and the detectibility of the failure. Based on the insights obtained from the FMEA, commissioning and QA procedures were developed to check (i) the accuracy of coordinate system transformation, (ii) system latency, (iii) spatial and dosimetric delivery accuracy, (iv) delivery efficiency, and (v) accuracy and consistency of system response to error conditions. The frequency of testing for each failure mode was determined from the RPN value. Results: Failures modes with RPN{>=}125 were recommended to be tested monthly. Failure modes with RPN<125 were assigned to be tested during comprehensive evaluations, e.g., during commissioning, annual quality assurance, and after major software/hardware upgrades. System latency was determined to be {approx}193 ms. The system showed consistent and accurate response to erroneous conditions. Tracking accuracy was within 3%-3 mm gamma (100% pass rate) for sinusoidal as well as a wide variety of patient-derived respiratory motions. The total time taken for monthly QA was {approx}35 min, while that taken for comprehensive testing was {approx}3.5 h. Conclusions: FMEA proved to be a powerful and flexible tool to develop and implement a quality management (QM) framework for DMLC tracking. The authors conclude that the use of FMEA-based QM ensures efficient allocation of clinical resources because the most critical failure modes receive the most attention. It is expected that the set of guidelines proposed here will serve as a living document that is updated with the accumulation of progressively more intrainstitutional and interinstitutional experience with DMLC tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual source model for Kilo-voltage cone beam CT: Source characteristics and model validation

Purpose: The purpose of this investigation was to study the source characteristics of a clinical kilo-voltage cone beam CT unit and to develop and validate a virtual source model that could be used for treatment planning purposes. Methods: We used a previously commissioned full Monte Carlo model and new bespoke software to study the source characteristics of a clinical kilo-voltage cone beam CT (CBCT) unit. We identified the main particle sources, their spatial, energy and angular distribution for all the image acquisition presets currently used in our clinical practice. This includes a combination of two energies (100 and 120 kVp), two filters (neutral and bowtie), and eight different x-ray beam apertures. We subsequently built a virtual source model which we validated against full Monte Carlo calculations. Results: We found that the radiation output of the clinical kilo-voltage cone beam CT unit investigated in this study could be reproduced with a virtual model comprising of two sources (target and filtration cone) or three sources (target, filtration cone and bowtie filter) when additional filtration was used. With this model, we accounted for more than 97% of the photons exiting the unit. Each source in our model was characterised by a origin distribution in both X and Y directions, a fluence map, a single energy spectrum for unfiltered beams and a two dimensional energy spectrum for bowtie filtered beams. The percentage dose difference between full Monte Carlo and virtual source model based dose distributions was well within the statistical uncertainty associated with the calculations ( {+-} 2%, one standard deviation) in all cases studied. Conclusions: The virtual source that we developed is accurate in calculating the dose delivered from a commercial kilo-voltage cone beam CT unit operating with routine clinical image acquisition settings. Our data have also shown that target, filtration cone, and bowtie filter sources needed to be all included in the model in order to accurately replicate the dose distribution from the clinical radiation beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-26: Analysis of Image Quality in CBCT QA Using a Treatment Planning System

Purpose: The objective of this study is to propose an alternative QA technique that analyzes imaging quality(IQ) in CBCT-QA processing. Methods: A catphan phantom was used to take CT imaging data set that were imported into a treatment planning system - Eclipse. The image quality was analyzed in terms of in-slice geometry resolution, Hounsfield numbers(HU) accuracy, mean-slice thickness, edge-to-center uniformity, low contrast resolution, and high contrast spatial resolution in Eclipse workstation. The CBCT-QA was also analyzed by OBI-workstation and a commercial software. Comparison was made to evaluation feasibility in a TPS environment. Results: The analysis of IQ was conducted in Eclipse v10.0 TPS. In-slice geometric resolution was measured between 2-rods in section CTP404 and repeated for all 4 rods with the difference between expected and measured values less than +/−0.1 cm. For HU, the difference between expected and measured values in HU was found much less than +/−40. Mean slice thickness measured by a distance on the wire proportional to scanner increment multiplying by a factor of 0.42. After repeating measurements to 4 wires, the average difference between expected and measured values was less +/−0.124 mm in slice thickness. HU uniformity was measured in section CTP486 with the tolerance less than +/−40 HU. Low contrast resolution in section CTP515 and high contrast resolution in section CTP528 were found to be 7 disks in diameter of 4 mm and 6 lp/cm, respectively. Eclipse TPS results indicated a good agreement to those obtained in OBI workstation and ImagePro software for major parameters. Conclusion: An analysis of IQ was proposed as an alternative CBCT QA processing. Based upon measured data assessment, proposed method was accurate and consistent to IQ evaluation and TG142 guideline. The approach was to utilize TPS resource, which can be valuable to re-planning, verification, and delivery in adaptive therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery

Purpose: To efficiently deliver respiratory-gated radiation during synchrotron-based pulsed heavy-ion radiotherapy, a novel respiratory guidance method combining a personalized audio-visual biofeedback (BFB) system, breath hold (BH), and synchrotron-based gating was designed to help patients synchronize their respiratory patterns with synchrotron pulses and to overcome typical limitations such as low efficiency, residual motion, and discomfort. Methods: In-house software was developed to acquire body surface marker positions and display BFB, gating signals, and real-time beam profiles on a LED screen. Patients were prompted to perform short BHs or short deep breath holds (SDBH) with the aid of BFB following a personalized standard BH/SDBH (stBH/stSDBH) guiding curve or their own representative BH/SDBH (reBH/reSDBH) guiding curve. A practical simulation was performed for a group of 15 volunteers to evaluate the feasibility and effectiveness of this method. Effective dose rates (EDRs), mean absolute errors between the guiding curves and the measured curves, and mean absolute deviations of the measured curves were obtained within 10%–50% duty cycles (DCs) that were synchronized with the synchrotron’s flat-top phase. Results: All maneuvers for an individual volunteer took approximately half an hour, and no one experienced discomfort during the maneuvers. Using the respiratory guidance methods, the magnitude of residual motion was almost ten times less than during nongated irradiation, and increases in the average effective dose rate by factors of 2.39–4.65, 2.39–4.59, 1.73–3.50, and 1.73–3.55 for the stBH, reBH, stSDBH, and reSDBH guiding maneuvers, respectively, were observed in contrast with conventional free breathing-based gated irradiation, depending on the respiratory-gated duty cycle settings. Conclusions: The proposed respiratory guidance method with personalized BFB was confirmed to be feasible in a group of volunteers. Increased effective dose rate and improved overall treatment precision were observed compared to conventional free breathing-based, respiratory-gated irradiation. Because breathing guidance curves could be established based on the respective average respiratory period and amplitude for each patient, it may be easier for patients to cooperate using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction

Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Data Mobility & Management for International Cosmology

In February 2015 the third workshop in the CrossConnects series, with a focus on Improving Data Mobility & Management for International Cosmology, was held at Lawrence Berkeley National Laboratory. Scientists from fields including astrophysics, cosmology, and astronomy collaborated with experts in computing and networking to outline strategic opportunities for enhancing scientific productivity and effectively managing the ever-increasing scale of scientific data. While each field has unique details which depend on the instruments employed, the type and scale of the data, and the structure of scientific collaborations, several important themes emerged from the workshop discussions. Findings, as well as a set of recommendations, are contained in their respective sections in this report.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon Next-Event Estimator Implementation in MCATK

A photon next-event fluence estimator at a point has been implemented in the Monte Carlo Application Toolkit (MCATK). The next-event estimator provides an expected value estimator for the flux at a point due to all source and collision events. An advantage of the next-event estimator over track-length estimators, which are normally employed in MCATK, is that flux estimates can be made in locations that have no random walk particle tracks. The next-event estimator allows users to calculate radiographs and estimate response for detectors outside of the modeled geometry. The next-event estimator is not yet accessable through the MCATK FlatAPI for C and Fortran. The next-event estimator in MCATK has been tested against MCNP6 using 5 suites of test problems. No issues were found in the MCATK implementation. One issue was found in the exclusion radius approximation in MCNP6. The theory, implementation, and testing are described in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗