Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Very-high-energy Emission from Pulsars

Air-Cherenkov telescopes have detected pulsations at energies above 50 GeV from a growing number of Fermi pulsars. These include the Crab, Vela, PSR B1706−44, and Geminga, with the first two having pulsed detections above 1 TeV. In some cases, there appears to be very-high-energy (VHE) emission that is an extension of the Fermi spectra to high energies, while in other cases, additional higher-energy spectral components that require a separate emission mechanism may be present. We present results of broadband spectral modeling using global magnetospheric fields and multiple emission mechanisms that include synchro-curvature (SC) and inverse Compton scattered (ICS) radiation from accelerated particles (primaries) and synchrotron self-Compton (SSC) emission from lower-energy pairs. Our models predict three distinct VHE components: SC from primaries whose high-energy tail can extend to 100 GeV, SSC from pairs that can extend to several TeV, and ICS from primary particles accelerated in the current sheet that scatter pair synchrotron radiation, which appears beyond 10 TeV. Our models suggest that H.E.S.S.-II and MAGIC have detected the high-energy tail of the primary SC component that produces the Fermi spectrum in Vela, Geminga, and PSR B1706−44. We argue that the ICS component peaking above 10 TeV from Vela has been seen by H.E.S.S. Detection of this emission component from the Crab and other pulsars is possible with the High Altitude Water Cherenkov Observatory and Cherenkov Telescope Array, and will directly measure the maximum particle energy in pulsars.

Alice K. Harding↗

High-energy Photon Opacity in the Twisted Magnetospheres of Magnetars

Magnetars are neutron stars characterized by strong surface magnetic fields generally exceeding the quantum critical value of 44.1 TG. High-energy photons propagating in their magnetospheres can be attenuated by QED processes like photon splitting and magnetic pair creation. In this paper, we compute the opacities due to photon splitting and pair creation by photons emitted anywhere in the magnetosphere of a magnetar. Axisymmetric, twisted dipole field configurations embedded in the Schwarzschild metric are treated. The paper computes the maximum energies for photon transparency that permit propagation to infinity in curved spacetime. Special emphasis is given to cases where photons are generated along magnetic field loops and/or in polar regions; these cases directly relate to resonant inverse Compton scattering models for the hard X-ray emission from magnetars and Comptonized soft gamma-ray emission from giant flares. We find that increases in magnetospheric twists raise or lower photon opacities, depending on both the emission locale and the competition between field-line straightening and field strength enhancement. Consequently, given the implicit spectral transparency of hard X-ray bursts and persistent "tail" emission of magnetars, photon splitting considerations constrain their emission region locales and the twist angle of the magnetosphere; these constraints can be probed by future soft gamma-ray telescopes such as COSI and AMEGO. The inclusion of twists generally increases the opaque volume of pair creation by photons above its threshold, except when photons are emitted in polar regions and approximately parallel to the field.

radiation mechanisms: non-thermal↗

The First X-Ray Polarimetric Observation of the Black Hole Binary LMC X-1

We report on an X-ray polarimetric observation of the high-mass X-ray binary LMC X-1 in the high/soft state, obtained by the Imaging X-ray Polarimetry Explorer ( IXPE ) in 2022 October. The measured polarization is below the minimum detectable polarization of 1.1 per cent (at the 99 per cent confidence level). Simultaneously, the source was observed with the Neutron Star Interior Composition Explorer (NICER), Nuclear Spectroscopic Telescope Array ( NuSTAR ), and Spectrum-Rontgen-Gamma ( SRG )/Astronomical Roentgen Telescope – X-ray Concentrator (ART-XC) instruments, which enabled spectral decomposition into a dominant thermal component and a Comptonized one. The low 2–8 keV polarization of the source did not allow for strong constraints on the black hole spin and inclination of the accretion disc. However, if the orbital inclination of about 36◦ is assumed, then the upper limit is consistent with predictions for pure thermal emission from geometrically thin and optically thick discs. Assuming the polarization degree of the Comptonization component to be 0, 4, or 10 per cent, and oriented perpendicular to the polarization of the disc emission (in turn assumed to be perpendicular to the large-scale ionization cone orientation detected in the optical band), an upper limit to the polarization of the disc emission of 1.0, 0.9, or 0.9 per cent, respectively, is found (at the 99 per cent confidence level).

LMC X-1↗

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Ajay S Gill↗

The E166 experiment: Development of an Undulator-Based Polarized Positron Source for the International Linear Collider

A longitudinal polarized positron beam is foreseen for the international linear collider (ILC). A proof-of-principle experiment has been performed in the final focus test beam at SLAC to demonstrate the production of polarized positrons for implementation at the ILC. The E166 experiment uses a 1 m long helical undulator in a 46.6 GeV electron beam to produce a few MeV photons with a high degree of circular polarization. These photons are then converted in a thin target to generate longitudinally polarized e{sup +} and e{sup -}. The positron polarization is measured using a Compton transmission polarimeter. The data analysis has shown asymmetries in the expected vicinity of 3.4% and {approx}1% for photons and positrons respectively and the expected positron longitudinal polarization is covering a range from 50% to 90%. The full exploitation of the physics potential of an international linear collider (ILC) will require the development of polarized positron beams. Having both e{sup +} and e{sup -} beams polarized will provide new insight into structures of couplings and thus give access to physics beyond the standard model [1]. The concept for a polarized positron source is based on circularly polarized photon sources. These photons are then converted to longitudinally polarized e{sup +} and e{sup -} pairs. While in an experiment at KEK [1a], Compton backscattering is used [2], the E166 experiment uses a helical undulator to produce polarized photons. An undulator-based positron source for the ILC has been proposed in [3,4]. The proposed scheme for an ILC positron source is illustrated in figure 1. In this scheme, a 150 GeV electron beam passes through a 120 m long helical undulator to produce an intense photon beam with a high degree of circular polarization. These photons are converted in a thin target to e{sup +} e{sup -} pairs. The polarized positrons are then collected, pre-accelerated to the damping ring and injected to the main linac. The E166 experiment is dedicated to test this concept of a helical-undulator-based polarized positron source for the ILC. The experiment was carried out at SLAC where it benefitted from the high quality electron beam in the final focus test beam (FFTB).

43 PARTICLE ACCELERATORS↗

Suzaku And Multi-Wavelength Observations of OJ 287 During the Periodic Optical Outburst in 2007

Suzaku observations of the blazar OJ 287 were performed in 2007 April 10-13 and November 7-9. They correspond to a quiescent and a flaring state, respectively. The X-ray spectra of the source can be well described with single power-law models in both exposures. The derived X-ray photon index and the flux density at 1 keV were found to be {Lambda} = 1.65 {+-} 0.02 and S{sub 1keV} = 215 {+-} 5 nJy, in the quiescent state. In the flaring state, the source exhibited a harder X-ray spectrum ({Lambda} = 1.50 {+-} 0.01) with a nearly doubled X-ray flux density S{sub 1keV} = 404{sub -5}{sup +6} nJy. Moreover, significant hard X-ray signals were detected up to {approx} 27 keV. In cooperation with the Suzaku, simultaneous radio, optical, and very-high-energy {gamma}-ray observations of OJ 287 were performed with the Nobeyama Millimeter Array, the KANATA telescope, and the MAGIC telescope, respectively. The radio and optical fluxes in the flaring state (3.04 {+-} 0.46 Jy and 8.93 {+-} 0.05 mJy at 86.75 Hz and in the V-band, respectively) were found to be higher by a factor of 2-3 than those in the quiescent state (1.73 {+-} 0.26 Jy and 3.03 {+-} 0.01 mJy at 86.75 Hz and in the V-band, respectively). No notable {gamma}-ray events were detected in either observation. The spectral energy distribution of OJ 287 indicated that the X-ray spectrum was dominated by inverse Compton radiation in both observations, while synchrotron radiation exhibited a spectral cutoff around the optical frequency. Furthermore, no significant difference in the synchrotron cutoff frequency was found between the quiescent and flaring states. According to a simple synchrotron self-Compton model, the change of the spectral energy distribution is due to an increase in the energy density of electrons with small changes of both the magnetic field strength and the maximum Lorentz factor of electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-Band RF Gun Development

In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into the structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.

43 PARTICLE ACCELERATORS↗

Multimode imaging device

Apparatus for detecting and locating a source of gamma rays of energies ranging from 10-20 keV to several MeV's includes plural gamma ray detectors arranged in a generally closed extended array so as to provide Compton scattering imaging and coded aperture imaging simultaneously. First detectors are arranged in a spaced manner about a surface defining the closed extended array which may be in the form a circle, a sphere, a square, a pentagon or higher order polygon. Some of the gamma rays are absorbed by the first detectors closest to the gamma source in Compton scattering, while the photons that go unabsorbed by passing through gaps disposed between adjacent first detectors are incident upon second detectors disposed on the side farthest from the gamma ray source, where the first spaced detectors form a coded aperture array for two or three dimensional gamma ray source detection.

47 OTHER INSTRUMENTATION↗

SoLID-SIDIS: Future Measurements of Transversity, TMDs and more

Over the past few decades, investigations of the nucleon structure mainly focused on the one-dimensional study of parton distributions and structure functions. New theoretical developments, including both transverse momentum distributions (TMDs) and generalized parton distributions (GPDs), provide a new way to understand the 3-dimensional structure of the nucleon. TMDs give access to the nucleon tomography in the momentum space, and also provide an opportunity to evaluate the contribution of quarks’ and gluons’ orbital angular momenta to the nucleon spin. The experimental study of TMDs requires a device with high luminosity, large kinematic coverage and great detection resolutions. With the Jefferson Lab (JLab) 12 GeV electron beam, we have proposed a Solenoidal Large Intensity Device (SoLID) in Hall A which is capable of performing such measurements. Several newly approved experiments will perform measurements of both the single and double spin asymmetries via semi-inclusive deep inelastic scattering (SIDIS) from polarized 3 He ("neutron") and proton targets. The new data will provide important information to extract TMDs with unprecedented precision. Besides, we are also able to use SoLID to explore many more important physics topics. Several experiments for the measurements of PVDIS and J=y production have been approved, and new proposals are under development. For example, with the similar SIDIS configuration, we are actively developing new measurements to study GPDs via deep virtual Compton scattering (DVCS) with polarized targets, doubly-DVCS, deep virtual meson production, time-like Compton scattering, and so on. Our collaboration has submitted the pre-conceptual design report to JLab and successfully passed the Director’s Review in early 2015. Our collaborators are focusing on optimizing the detector system, finalizing the detector designs and proceeding on the detector R&D. We are looking forward to having the DOE Science Review in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Peak Doctor v 1.0.0 Labview Version

PeakDoctor software works interactively with its user to analyze raw gamma-ray spectroscopic data. The goal of the software is to produce a list of energies and areas of all of the peaks in the spectrum, as accurately as possible. It starts by performing an energy calibration, creating a function that describes how energy can be related to channel number. Next, the software determines which channels in the raw histogram are in the Compton continuum and which channels are parts of a peak. Then the software fits the Compton continuum with cubic polynomials. The last step is to fit all of the peaks with Gaussian functions, thus producing the list.

Garner, Scott↗

Studies of EMP generation using a Lienard-Wiechert formulation, and progress toward a 3-D EMP code

Here, we describe studies of the generation of electro-magnetic pulse (EMP) fields under the idealized conditions of a delta-function gamma pulse, a spherical cap of Compton electrons located at a common radius from the burst, and the absence of the conduction current. Various processes (geomagnetic rotation, drag, and scattering) contribute to the time derivative of the Compton current density, which appears as the source term in the Lienard–Wiechert expression for the radiation field. These processes are considered separately and in combination, and their influences on the waveform of the EMP assessed. Using a separate computational approach, different numerical models of multiple scattering are tested, in an effort to assess the validity of existing codes and earlier results. We also describe plans for and progress toward a comprehensive 3-D EMP code, which is to employ recently developed numerical methods and is to offer a variety of models, including the Lienard–Wiechert formulation described here.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SuperCDMS Background Models for Low-Mass Dark Matter Searches

An abundance of astrophysical and cosmological evidence indicates the existence of a non-luminous, non-baryonic form of matter, called dark matter, that is approximately a quarter of all energy in the universe. One promising candidate for dark matter is the Weakly Interacting Massive Particle (WIMP) which interacts with baryonic matter at most on the scale of the weak force. The Cryogenic Dark Matter Search (CDMS) experiment aims to detect the nuclear recoils induced by the elastic scattering of WIMPs off of germanium nuclei. This is a rare signal and difficult to detect, especially the low-energy recoils that are produced by low-mass dark matter. The CDMS project operated at the Soudan Underground Laboratory from 2003--2015, with an upgrade to the SuperCDMS experiment in 2012. The germanium detectors were operated at 50~mK and able to measure both the ionization and athermal phonons produced in a particle interaction. Measuring two signals enables discrimination between electron recoil and nuclear recoil events. An alternative operating mode for the detectors is called the CDMS low ionization threshold experiment (CDMSlite), where a higher bias was applied to the detectors and only the phonon signal analyzed. This method increased sensitivity to low-mass dark matter interactions, but sacrificed discrimination capability. The CDMSlite spectrum had a large contribution from electron recoil background events. From the information gained during the first two CDMSlite Runs, a background model was developed for the third and final CDMSlite Run. Analytical descriptions were identified for those backgrounds that were theoretically known, e.g. tritium $\beta$-spectrum, and Geant simulations were used to understand and predict the low-energy spectra from other sources, e.g. Compton scattering. Multiple new models were developed for detectors operated in CDMSlite at Soudan. These include the analytical formula for Compton scattering, and empirical models for surface backgrounds from $^{210}$Pb contamination of the germanium crystals and detector housing. In order to accurately describe the surface events, a new detector response function was developed that included information about the electric field and energy resolution of the detector. These models were essential to the implementation of a profile likelihood analysis of the CDMSlite Run 3 data, which improved on the sensitivity to dark matter over the Run 2 optimum interval analysis for WIMP masses above 2.5~GeV/$c^2$. This demonstrated a successful application of a likelihood analysis to the high-voltage operating mode, and the potential for these analyses in the future SuperCDMS SNOLAB experiment. For the SuperCDMS SNOLAB experiment, the change in background rates from radiogenic neutrons was considered as additional towers of detectors were added, and the feasibility of an active neutron veto as a potential upgrade for large payloads was studied. This veto could be constructed of plastic scintillator with layers of gadolinium resin, and would aid in reducing the nuclear recoil single scatter background that is indistinguishable from the WIMP signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation for a Measurement of Charge Asymmetry in the Bethe-Heitler Process

We have prepared a measurement of the energy asymmetry in wide- and medium-angle electron/positron pair production off protons and heavy targets. This asymmetry is caused by the interference between the first- and second-order Born diagrams and the Compton scattering diagram. It directly probes aspects of QED, as well as providing a direct measurement of the real part of the Compton amplitude. It will be conducted at the HI??S facility at Duke University, using a 60 MeV photon beam. This dissertation serves as documentation of the preparation stage of the Bethe-Heitler experiment. The major was the recommissioning of the vertical drift chambers previously used in the Q-weak experiment at the Jefferson Lab. Cosmic test runs were conducted, drift time data were collected and efficiency plateaus were measured. We made modifications to the JLAB Hall A analyzer to suit the geometry and drift characteristics of these wire chambers. The analyzer was used for the reconstruction of the trajectories of cosmic ray test runs with the results confirmed by direct measurement of trigger geometry. Spatial and angular resolution is estimated to ~300?? and 0.17° respectively. Geant 4 simulations with generated Bethe-Heitler pairs satisfying theoretical differential cross sections. It was used to check detector acceptance, optimize apparatus layout, and estimate measurable energy asymmetry. The measurable asymmetries from electron/positron pairs with polar angles around between approximately 5° and 8°, azimuthal angles differing by 180°, and energy differing by approximately 9 MeV to 15 MeV are predicted to be above 10%. The kinematics of primary vertices are reconstructed using the data from wire chambers in the simulation. The energy resolution is determined to be better than 1MeV.

Chen, Haoyu↗

Development of a non-invasive, continuous polarimeter for Hall C at Jefferson Lab

The stringent requirements of the parity violating experimental program at Jefferson Lab necessitate an accurate knowledge of electron beam polarization. In particular, the tight error budget for the Qweak experiment currently in production in Hall C allows an error of only ±1% for the measurement of electron beam polarization. In order to achieve this, a Compton polarimeter has been recently built in Hall C and is being utilized as part of the polarimetry program. Compton polarimetry derives its analyzing power from the spin dependence of the γ-e interaction and requires a highly polarized coherent beam of photons with well known properties. I discuss the development and performance of a resonant optical cavity at a wavelength of 532~nm for use as a photon target and some of the difficulties encountered in the process, as well as the means of determining intra-cavity beam properties.

Jones, Donald↗

Moller Polarimetry for the Qweak Experiment

The Standard Model of particle physics has been extremely successful in describing particle interactions in a wide-ranging regime of energy scales. Low-energy, parity-violating experiments enable high-precision experimental tests of Standard Model predictions. Currently, Jefferson Lab is performing one such investigation to determine the weak charge of the proton, Qweak, to 4\% precision using ep scattering. By making a precise measurement of the weak charge, this experiment will provide tighter constraints on some classes of ``new physics'' at 2 TeV or higher. To calculate the parity-violating asymmetry and determine Qweak one needs precise knowledge of the incoming electron beam polarization. The Qweak experiment, which is underway in Jefferson Lab's Hall C, uses both M{\o}ller and Compton polarimetry to determine the 1 GeV beam polarization. The Hall C M{\o}ller polarimeter is particularly relevant as it uses a superconducting magnet to saturate thin, pure iron, foils out of plane. This provides precise measurements of beam polarization to within 1\% uncertainty. Since the addition of the Compton device the M\o ller polarimeter has undergone a re-commissioning phase, followed by myriad studies to reduce the systematic errors to the 0.57\% level required by Qweak. A brief overview of the Hall C M{\o}ller device, followed by preliminary results of these studies and of the Spring 2011 experiment run, will be provided.

Magee, Joshua↗

The Atacama Cosmology Telescope: High-resolution component-separated maps across one-third of the sky

Observations of the millimeter sky contain valuable information on a number of signals, including the blackbody cosmic microwave background (CMB), Galactic emissions, and the Compton-$y$ distortion due to the thermal Sunyaev-Zel'dovich (tSZ) effect. Extracting new insight into cosmological and astrophysical questions often requires combining multi-wavelength observations to spectrally isolate one component. In this work, we present a new arcminute-resolution Compton-$y$ map, which traces out the line-of-sight-integrated electron pressure, as well as maps of the CMB in intensity and E-mode polarization, across a third of the sky (around 13,000 sq.~deg.). We produce these through a joint analysis of data from the Atacama Cosmology Telescope (ACT) Data Release 4 and 6 at frequencies of roughly 93, 148, and 225 GHz, together with data from the \textit{Planck} satellite at frequencies between 30 GHz and 545 GHz. We present detailed verification of an internal linear combination pipeline implemented in a needlet frame that allows us to efficiently suppress Galactic contamination and account for spatial variations in the ACT instrument noise. These maps provide a significant advance, in noise levels and resolution, over the existing \textit{Planck} component-separated maps and will enable a host of science goals including studies of cluster and galaxy astrophysics, inferences of the cosmic velocity field, primordial non-Gaussianity searches, and gravitational lensing reconstruction of the CMB.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Code of Radiation Damage by Gamma - Paper 62

In recent years, the study of radiation damage of materials has seen a thrust because of the expectation of the high rate of radiation damage in fusion reactors, accelerator driven sub critical systems and damage of a control system of space vehicles by the high energy neutrons and gamma showers. Embrittlement of reactor vessels, corrosion of steel and swelling of fuel rods are the well known empirical examples of severe radiation damage. It is also realized that damage by high energy gammas is in no way insignificant, and it is equivalent to the damage by the neutrons. Secondly, value addition of certain materials like enhancement of electrical resistance, mechanical strength, color enhancement of precious stones on irradiation by neutrons and gammas and polymerization in the presence of gamma radiation add to the necessity of a Monte Carlo (MC) code of radiation damage in a wide range of energy. The JAIPU code, for the study of radiation damage by neutrons up to 10 MeV energy, incorporates features like development of secondary atomic cascade and PKA energy corrected for the ionization lose and production of Frenkel pair. MC estimation of both the primary and secondary displacements has been compared with the Frenkel pairs calculated using the NRT model. In the present work, JAIPU code is extended for irradiation of materials by high energy gammas. Here cascade generated by the incident gamma produces electrons by way of photo-electric, Compton and pair production until it is absorbed. The recoiled Frenkel pairs produced in electron + atom collision have been considered for the purpose of atomic cascade. Standard cross section libraries for gamma and electron interaction are used while for atom + atom collision we have made use of the IOTA code. In addition, in the code, the lattice structure of the irradiated material is simulated to know the positions of the photon interactions with atoms and the energy of electron it adds an extra feature of the position and size of the voids and the clusters produced on irradiation. The code has the possibility of calculation of 'absorbed radiation dose' and 'KERMA' and the interatomic distances of the displaced atoms. It may be pointed out that the code uses only the MC simulation of the number of displacements unlike several other approaches where the NRT model with PKA energy is used for gross estimation of the number of the displaced atoms. Thus, the code keeps an account of the positions of displaced atoms for the in-depth modification of the irradiated material. 1 MeV gamma seems to damage Fe up to several millimeters of its depth and this is mostly by the recoiled Compton electrons than photo electrons. The code is in the developmental stage and it has the capability of applications in the developing field of Radiology besides the shielding and other studies of radiation damage. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗