Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Chiral properties of the nucleon interpolating current and θ-dependent observables

We revisit the chiral properties of nucleon interpolating currents, and show that of the two leading order currents j 1 and j 2 , only two linear combinations j 1 ± j 2 transform covariantly under the anomalous U⁢(1) A symmetry. As a result, calculations of quantities which vanish by symmetry in the chiral limit may produce unphysical results if carried out with different linear combinations of the currents. This includes observables such as electric dipole moments, induced by the quantum chromodynamics (QCD) parameter θ, and the θ-dependence of the nucleon mass. For completeness, we also exhibit the leading order results for nucleon electric dipole moments (d n,p ) induced by θ, and the nucleon magnetic moments (μ n,p ), when calculated using QCD sum rules for both the covariant choices of the nucleon interpolating current. The results in each channel, conveniently expressed as the ratios, d n,p /μ n,p , are numerically consistent, and reflect the required physical dependence on θ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of two mechanisms for current production in a biharmonic flashing electron ratchet

Ratchets rectify the motion of randomly moving particles, which are driven by isotropic sources of energy such as thermal and chemical energy, without applying a net, time-averaged force between source and drain. We describe the behavior of a damped electron, modeled by a quantum Lindblad master equation, within a flashing ratchet (a one-dimensional potential that oscillates between a flat surface and a periodic asymmetric surface). By investigating the complete space of all biharmonic potential shapes and a large range of oscillation frequencies, two modes of ratchet operation, differentiated by their oscillation frequencies (relative to the rate of electron relaxation), are identified. Slow-oscillating, strong friction ratchets operate by a classical, overdamped mechanism. In fast-oscillating, weak friction ratchets, current is primarily produced when the frequency of the oscillating potential is resonant with the beating of the electron wave function in the potential well. The shape of the ratchet potential determines the direction of the current (and, in some cases, straightforwardly accounts for current reversals), but the maximum achievable current at any shape is controlled by the degree of friction applied to the electron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation and Characterization of Electron Bunches with Ramped Current Profiles in a Dual-Frequency Superconducting Linear Accelerator

We report on the successful experimental generation of electron bunches with ramped current profiles. The technique relies on impressing nonlinear correlations in the longitudinal phase space using a superconducing radiofrequency linear accelerator operating at two frequencies and a current-enhancing dispersive section. The produced {approx} 700-MeV bunches have peak currents of the order of a kilo-Ampere. Data taken for various accelerator settings demonstrate the versatility of the method and in particular its ability to produce current profiles that have a quasi-linear dependency on the longitudinal (temporal) coordinate. The measured bunch parameters are shown, via numerical simulations, to produce gigavolt-per-meter peak accelerating electric fields with transformer ratios larger than 2 in dielectric-lined waveguides.

43 PARTICLE ACCELERATORS↗

Disruption of Current Filaments and Isotropization of the Magnetic Field in Counterstreaming Plasmas

In this paper, we study the stability of current filaments produced by the Weibel, or current filamentation, instability in weakly magnetized counterstreaming plasmas. It is shown that a resonance exists between the current-carrying ions and a longitudinal drift-kink mode that strongly deforms and eventually breaks the current filaments. Analytical estimates of the wavelength, growth rate, and saturation level of the resonant mode are derived and validated by three-dimensional particle-in-cell simulations. Finally and furthermore, self-consistent simulations of counterstreaming plasmas indicate that this drift-kink mode is dominant in the slow down of the flows and in the isotropization of the magnetic field, playing an important role in the formation of collisionless shocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of an axial magnetic field on the current distribution in a Z-pinch implosion with preembedded magnetic field

In this study, the fundamental physics of the magnetic field distribution in a plasma implosion with a pre-embedded magnetic field is investigated within a gas puff Z-pinch. Time and space resolved spectroscopy of the polarized Zeeman effect, applied for the first time, reveals the impact of a pre-embedded axial field on the evolution of the current distribution driven by a pulsed-power generator. The measurements show that the azimuthal magnetic field in the imploding plasma, even in the presence of a weak axial magnetic field, is substantially smaller than expected from the ratio of the driving current to the plasma radius. Much of the current flows at large radii through a slowly-imploding, low-density plasma. The development of a force-free current configuration is suggested to explain this phenomenon. Finally, previously unpredicted observations in higher-power imploding-magnetized-plasma experiments, including recent unexplained structures observed in the Magnetized Liner Inertial Fusion experiment, may be explained by the present discovery.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current-Induced Reversal of Anomalous Hall Conductance in Twisted Bilayer Graphene

It is observed experimentally that the sign of the Hall resistance can be flipped by a dc electric current in the twisted bilayer graphene (TBG) at 3/4 filling of the fourfold degenerate conduction flat bands. The experiment implies a switching of the valley polarization (VP) and topology in TBG. In this work, we present a theory on the current-induced switching of VP and topology. The presence of current in the bulk causes the redistribution of electron occupation in bands near the Fermi energy, which then deforms and shifts the band dispersion due to the Coulomb interaction. Above a critical current, the original occupied and empty bands can be swapped, resulting in the switching of VP and topology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent High-Frequency Axial Oscillations in a Partially Magnetized Direct Current Magnetron Discharge

High-frequency oscillations are observed in a neon plasma of a direct current magnetron discharge. At low discharge currents, we see highly coherent 60 MHz fluctuations. Above a distinct current threshold, secondary 5–10 MHz fluctuations emerge in addition to turbulent fluctuations in the 60–100 MHz range. The oscillations in the total discharge current suggest axial wave propagation. A lower-hybrid wave theory is invoked to model the high-frequency oscillations. Here, we attribute the low-frequency modes to a turbulence-driven inverse cascade process, as suggested by recent simulations.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Two-Body Currents on Magnetic Dipole Moments of Nuclei

We investigate the effects of two-body currents on magnetic dipole moments of medium-mass and heavy nuclei using the valence-space in-medium similarity renormalization group with chiral effective field theory interactions and currents. Focusing on near doubly magic nuclei from oxygen to bismuth, we have found that the leading two-body currents globally improve the agreement with experimental magnetic moments. Moreover, our results show the importance of multishell effects for Ca 41 , which suggest that the Z = N = 20 gap in Ca 40 is not as robust as in Ca 48 . The increasing contribution of two-body currents in heavier systems is explained by the operator structure of the center-of-mass dependent Sachs term. Published by the American Physical Society 2024

Physics↗

Electrical-current-induced magnetic hysteresis in self-assembled vertically aligned L a 2 / 3 S r 1 / 3 Mn O 3 : ZnO nanopillar composites

Magnetoresistive random-access memory (MRAM) is poised to become a next-generation information storage device. Yet, many materials challenges remain unsolved before it can become a widely used memory storage solution. Among them, an urgent need is to identify a material system that is suitable for downscaling and is compatible with low-power logic applications. Self-assembled, vertically aligned La 2/3 Sr 1/3 MnO 3 : ZnO nanocomposites, in which La 2/3 Sr 1/3 MnO 3 (LSMO) matrix and ZnO nanopillars form an intertwined structure with coincident-site-matched growth occurring between the LSMO and ZnO vertical interfaces, may offer new MRAM applications by combining their superior electric, magnetic ( B ), and optical properties. Here, in this Rapid Communication, we show the results of electrical current induced magnetic hysteresis in magnetoresistance measurements in these nanopillar composites. We observe that when the current level is low, for example, 1 µA, the magnetoresistance displays a linear, negative, nonhysteretic B field dependence. Surprisingly, when a large current is used, I > 10 µA, a hysteretic behavior is observed when the B field is swept in the up and down directions. This hysteresis weakens as the sample temperature is increased. Finally, a possible spin-valve mechanism related to this electrical current induced magnetic hysteresis is proposed and discussed.

36 MATERIALS SCIENCE↗

Structural changes induced by electric currents in a single crystal of Pr 2 CuO 4

We demonstrate an approach to the structural and electronic property modification of perovskites, focusing on Pr 2 CuO 4 , an undoped parent compound of a class of electron-doped copper-oxide superconductors. Currents were passed parallel or perpendicular to the copper oxygen layers with the voltage ramped up until a rapid drop in the resistivity was achieved, a process referred to as “flash.” The current was then further increased tenfold in current-control mode. This state was quenched by immersion into liquid nitrogen. Flash can drive many compounds into different atomic structures with new properties, whereas the quench freezes them into a long-lived state. Single-crystal neutron diffraction of as-grown and modified Pr 2 CuO 4 revealed a √10 ×√10 superlattice due to oxygen-vacancy order. The diffraction peak intensities of the superlattice of the modified sample were significantly enhanced relative to the pristine sample. Raman-active phonons in the modified sample were considerably sharper. Measurements of electrical resistivity, magnetization, and two-magnon Raman scattering indicate that the modification affected only the Pr-O layers, but not the Cu-O planes. These results point to enhanced oxygen-vacancy order in the modified samples well beyond what can be achieved without passing electrical current. Our work opens a new avenue toward electric field/quench control of structure and properties of layered perovskite oxides.

36 MATERIALS SCIENCE↗

Emergent Inductance from Chiral Orbital Currents in a Bulk Ferrimagnet

Here, we report the discovery of a new form of inductance in the bulk ferrimagnet Mn 3 ⁢Si 2 ⁢Te 6 , which features strong spin-orbit coupling, large magnetic anisotropy, and pronounced magnetoelastic interactions. Below its Curie temperature (𝑇 𝐶 ≈ 78 K), Mn 3 ⁢Si 2 ⁢Te 6 hosts chiral orbital currents (COC) that circulate within the crystal lattice and give rise to collective electronic behavior [Control of chiral orbital currents in a colossal magnetoresistance material, Nature (London) 611, 467 (2022).]. By applying a magnetic field along the hard 𝑐 axis and driving the system with low-frequency currents, we uncover a giant inductive response up to millhenry scale, originating from first-order reconfigurations of COC domains. These domains act as coherent mesoscopic inductive elements that resist reversal upon current reduction, producing a large electromotive force and sharply increasing voltage. This emergent inductance defies classical models, occurs without superconductivity or engineered nanostructures, and opens a new frontier in orbital-based quantum functionality and device concepts.

complex materials↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Analysis of Circulating Harmonic Currents in Paralleled Three Level ANPC Inverters using SVM

In paralleled voltage source inverters (VSI), circulating current has both high frequency and low frequency components, and its spectrum highly depends on the modulation scheme. Previous research has mostly focused on the circulating current suppression for paralleled two-level VSIs. Little literature exists on similar analysis for paralleled three-level VSIs using space vector modulation. A detailed circulating current spectrum on full frequency range has not been well developed. This paper presents an improved analytical model for three-level space vector modulation (SVM), considering the impacts of regularly sampled reference and dead time. Then, circulating harmonic currents are determined across the full frequency range for various interleaving angles of two three-level ANPC inverters. The calculated harmonics are also verified by experimental results.

Niu, Jiahao↗

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic in Dual-Active-Bridge Converters

The Dual-Active-Bridge (DAB) converter transformer flux unbalance, or dc bias, could be a critical issue due to the mismatches of converter circuit parameters and control transients. In this paper, a steady-state flux balancing scheme, based on the second-order harmonic of magnetizing current has been proposed. The relationship between steady-state flux/magnetizing current unbalance and its harmonic contents has been analyzed, with which a new current sensing method and control strategy are introduced. The proposed magnetizing current sensing method can be implemented for both unity and complicated fractional turns ratios, without high sensitivity to dc offset from the analog circuitry. The proposed scheme has been validated with experimental results on 850-V/850-V DAB converters within a system, as well as in an 850-V/6700-V medium voltage DAB unit.

Gao, Zihan↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

A Novel Model of Thyristor in Reverse Recovery Process for Current Interruption Test of HVDC Circuit Breakers

The high voltage thyristor is widely used in high voltage DC (HVDC) grids due to its large current capability. Recently, the high voltage thyristor is implemented to produce a high current in the HVDC circuit breaker (CB) testing process. Unfortunately, the reverse recovery process (RRP) of a thyristor could induce significant turn-off overvoltage and power losses, jeopardizing the safety of the devices. The existing models of a thyristor cannot describe such hard-switching transient accurately. Therefore, this paper divides this process into four stages based on the physical mechanism and proposes a novel cosine exponential (CE), simulating the voltage and current of the thyristor with analytical equations, which are derived from the equivalent circuit. Moreover, the extraction procedure of the proposed model is illustrated in this paper. Finally, we develop an HVDC CB test platform to validate the proposed model. Experimental results show that the proposed CE model can accurately predict the overvoltage with a relative error of less than 8% at various current varying rates.

Dongye, Zhonghao↗