Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Baseline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Computational fluid dynamics (CFD) in the design of a water-jet-drive system

NASA/Marshall Space Flight Center (MSFC) has an ongoing effort to transfer to industry the technologies developed at MSFC for rocket propulsion systems. The Technology Utilization (TU) Office at MSFC promotes these efforts and accepts requests for assistance from industry. One such solicitation involves a request from North American Marine Jet, Inc. (NAMJ) for assistance in the design of a water-jet-drive system to fill a gap in NAMJ's product line. NAMJ provided MSFC with a baseline axial flow impeller design as well as the relevant working parameters (rpm, flow rate, etc.). This baseline design was analyzed using CFD, and significant deficiencies identified. Four additional analyses were performed involving MSFC changes to the geometric and operational parameters of the baseline case. Subsequently, the impeller was redesigned by NAMJ and analyzed by MSFC. This new configuration performs significantly better than the baseline design. Similar cooperative activities are planned for the design of the jet-drive inlet.

Garcia, Roberto↗

Ten-year ground exposure of composite materials used on the Bell Model 206L helicopter flight service program

Residual strength results are presented for four composite material systems that have been exposed for up to 10 years to the environment at five different locations on the North American continent. The exposure locations are near where the Bell Model 206L helicopters, which participated in a flight service program sponsored by NASA Langley Research Center and the U.S. Army, were flying in daily commercial service. The composite material systems are (1) Kevlar-49 fabric/F-185 epoxy; (2) Kevlar-49 fabric/LRF-277 epoxy; (3) Kevlar-49 fabric/CE-306 epoxy; and (4) T-300 graphite/E-788 epoxy. Six replicates of each material were removed and tested after 1, 3, 5, 7, and 10 years of exposure. The average baseline strength was determined from testing six as-fabricated specimens. More than 1700 specimens have been tested. All specimens that were tested to determine their strength were painted with a polyurethane paint. Each set of specimens also included an unpainted panel for observing the weathering effects on the composite materials. A statistically based procedure has been used to determine the strength value above which at least 90 percent of the population is expected to fall with a 95-percent confidence level. The computed compression strengths are 80 to 90 percent of the baseline (no-exposure) strengths. The resulting compression strengths are approximately 8 percent below the population mean strengths. The computed short-beam-shear strengths are 83 to 92 percent of the baseline (no-exposure) strengths. The computed tension strength of all materials is 93 to 97 percent of the baseline (no-exposure) strengths.

Baker, Donald J.↗

Crystal Growth Furnace (CGF)

The contract baseline, contract requirements review, contract modifications, contract problem areas and conclusions are addressed. Contract baseline was established 11 June 1987 and updated 1 December 1989. Significant changes were introduced into the 1989 baseline as compared to the original baseline. Contract modifications were made to add requirements as the program matured and as definition of requirements were completed. Problems were solved in real time through the contractor/customer team involvement and relationship to assure a timely and successful mission. The conclusion is that the CGF performed as designed and the experiments performed during the USML-1 Mission supports the conclusion.

Billingsley, Charles E.↗

Atmospheric pressure loading effects on Global Positioning System coordinate determinations

Earth deformation signals caused by atmospheric pressure loading are detected in vertical position estimates at Global Positioning System (GPS) stations. Surface displacements due to changes in atmospheric pressure account for up to 24% of the total variance in the GPS height estimates. The detected loading signals are larger at higher latitudes where pressure variations are greatest; the largest effect is observed at Fairbanks, Alaska (latitude 65 deg), with a signal root mean square (RMS) of 5 mm. Out of 19 continuously operating GPS sites (with a mean of 281 daily solutions per site), 18 show a positive correlation between the GPS vertical estimates and the modeled loading displacements. Accounting for loading reduces the variance of the vertical station positions on 12 of the 19 sites investigated. Removing the modeled pressure loading from GPS determinations of baseline length for baselines longer than 6000 km reduces the variance on 73 of the 117 baselines investigated. The slight increase in variance for some of the sites and baselines is consistent with expected statistical fluctuations. The results from most stations are consistent with approximately 65% of the modeled pressure load being found in the GPS vertical position measurements. Removing an annual signal from both the measured heights and the modeled load time series leaves this value unchanged. The source of the remaining discrepancy between the modeled and observed loading signal may be the result of (1) anisotropic effects in the Earth's loading response, (2) errors in GPS estimates of tropospheric delay, (3) errors in the surface pressure data, or (4) annual signals in the time series of loading and station heights. In addition, we find that using site dependent coefficients, determined by fitting local pressure to the modeled radial displacements, reduces the variance of the measured station heights as well as or better than using the global convolution sum.

Vandam, Tonie M.↗

GPS Attitude Determination Using Deployable-Mounted Antennas

The primary objective of this investigation is to develop a method to solve for spacecraft attitude in the presence of potential incomplete antenna deployment. Most research on the use of the Global Positioning System (GPS) in attitude determination has assumed that the antenna baselines are known to less than 5 centimeters, or one quarter of the GPS signal wavelength. However, if the GPS antennas are mounted on a deployable fixture such as a solar panel, the actual antenna positions will not necessarily be within 5 cm of nominal. Incomplete antenna deployment could cause the baselines to be grossly in error, perhaps by as much as a meter. Overcoming this large uncertainty in order to accurately determine attitude is the focus of this study. To this end, a two-step solution method is proposed. The first step uses a least-squares estimate of the baselines to geometrically calculate the deployment angle errors of the solar panels. For the spacecraft under investigation, the first step determines the baselines to 3-4 cm with 4-8 minutes of data. A Kalman filter is then used to complete the attitude determination process, resulting in typical attitude errors of 0.50.

Osborne, Michael L.↗

Comparison of the Compressive Strengths for Stitched and Toughened Composite Systems

The compression strength of a stitched and a toughened matrix graphite/epoxy composite was determined and compared to a baseline unstitched untoughened composite. Two different layups with a variety of test lengths were tested under both ambient and hot/wet conditions. No significant difference in strength was seen for the different materials when the gage lengths of the specimens were long enough to lead to a buckling failure. For shorter specimens, a 30% reduction in strength from the baseline was seen due to stitching for both a 48-ply quasi-isotropic and a (0/45/0/-45/90/-45/0/45/0)s laminate. Analysis of the results suggested that the decrease in strength was due to increased fiber misalignment due to the stitches. An observed increasing strength with decreasing gage length, which was seen for all materials, was explained with a size effect model. The model assumed a random distribution of flaws (misaligned fibers). The toughened material showed a small increase in strength over the baseline material for both laminates presumably due to the compensating effects of a more compliant matrix and straighter fibers in the toughened material. The hot/wet strength of the stitched and baseline material fell 30% below their ambient strengths for shorter, non-buckling specimen, while the strength of the toughened matrix material only fell 20%. Video images of the failing specimen were recorded and showed local failures prior to global collapse of the specimen. These images support the theory of a random distribution of flaws controlling composite failure. Failed specimen appearance however, seems to be a misleading indication of the cause of failure.

Reeder, James R.↗

Pulse Detonation Engine Air Induction System Analysis

A preliminary mixed-compression inlet design concept for potential pulse-detonation engine (PDE) powered supersonic aircraft was defined and analyzed. The objectives of this research were to conceptually design and integrate an inlet/PDE propulsion system into a supersonic aircraft, perform time-dependent CFD analysis of the inlet flowfield, and to estimate the installed PDE cycle performance. The study was baselined to a NASA Mach 5 Waverider study vehicle in which the baseline over/under turboramjet engines were replaced with a single flowpath PDE propulsion system. As much commonality as possible was maintained with the baseline configuration, including the engine location and forebody lines. Modifications were made to the inlet system's external ramp angles and a rotating cowl lip was incorporated to improve off-design inlet operability and performance. Engines were sized to match the baseline vehicle study's ascent trajectory thrust requirement at Mach 1.2. The majority of this study was focused on a flight Mach number of 3.0. The time-dependent Navier Stokes CFD analyses of a two-dimensional approximation of the inlet was conducted for the Mach 3.0 condition. The Lockheed Martin Tactical Aircraft Systems-developed FALCON CFD code with a two equation 'k-1' turbulence model was used. The downstream PDE was simulated by an array of four sonic nozzles in which the flow areas were rapidly varied in various opening/closing combinations. Results of the CFD study indicated that the inlet design concept operated successfully at the Mach 3.0 condition, satisfying mass capture, total pressure recovery, and operability requirements. Time-dependent analysis indicated that pressure and expansion waves from the simulated valve perturbations did not effect the inlet's operability or performance.

Pegg, R. J.↗

Simulated Microgravity Increases Cutaneous Blood Flow in the Head and Leg of Humans

The cutaneous micro-circulation vasodilates during acute 6 deg. head-down tilt (HDT, simulated microgravity) relative to upright conditions, more in the lower body than in the upper body. We expected that relative magnitudes of and differences between upper and lower body cutaneous blood flow elevation would be sustained during initial acclimation to simulated microgravity. We measured cutaneous micro-vascular blood flow with laser-Doppler flowmetry at the leg (over the distal tibia) and cheek (over the zygomatic arch) of eight healthy men before, during, and after 24 h of HDT. Results were calculated as a percentage of baseline value (100% measured during pre-tilt upright sitting). Cutaneous blood flow in the cheek increased significantly to 165 +/- 37% (mean + SE, p less than 0.05) at 9-12 h HDT, then returned to near baseline values by 24 h HDT (114 +/- 29%, NSD), despite increased local arterial pressure. Microvascular flow in the leg remained significantly elevated above baseline throughout 24 h HDT (427 +/- 85% at 3 h HDT and 215 +/- 142% at 24 h HDT, p less than 0.05). During the 6-h upright sitting recovery period, cheek and leg blood flow levels returned to near pre-tilt baseline values. Because hydrostatic effects of HDT increase local arterial pressure at the carotid sinus, baroreflex-mediated withdrawal of sympathetic tone probably contributed to increased microvascular flows at the head and leg during HDT. In the leg, baroreflex effects combined with minimal stimulation of local veno-arteriolar and myogenic autoregulatory vasoconstriction to elicit relatively larger and more sustained increases in cutaneous flow during HDT. In the cheek, delayed myogenic vasoconstriction and/or humoral effects apparently compensated for flow elevation by 24 h of HDT. Therefore, localized vascular adaptations to gravity probably explain differences in acclimation of lower and upper body blood flow to HDT and actual microgravity.

Stout, M. Shannon↗

Simulated Microgravity Increases Cutaneous Blood Flow in the Head and Leg of Humans

The cutaneous microcirculation vasodilates during acute 6 degree head-down tilt (HDT, simulated microgravity) relative to upright conditions, more in the lower body than in the upper body. Cutaneous microvascular blood flow was measured with laser-Doppler flowmetry at the leg (over the distal tibia) and cheek (over the zygomatic arch) of eight healthy men before, during, and after 24 h of HDT. Results were calculated as a percentage of baseline value (100% measured during pre-tilt upright sitting). Cutaneous blood flow in the cheek increased significantly to 165 +/- 37% (mean +/- SE, p less than 0.05) at 9-12 h HDT, then returned to near baseline values by 24 h HDT (114 +/- 29%, NSD), despite increased local arterial pressure. Microvascular flow in the leg remained significantly elevated above baseline througout 24 h HDT (427 +/- 85% at 3 h HDT and 215 +/- 142% at 24 h HDT, p less than 0.05). During the 6-h upright sitting recovery period, cheek and leg blood flow levels returned to near pre-tilt baseline values. Because hydrostatic effects of HDT increase local arterial pressure at the carotid sinus, baroreflex-mediated withdrawal of sympathetic tone probably contributed to increased microvascular flows at the head and leg during HDT. In the leg baroreflex effects combined with minimal stimulation of local veno-arteriolar and myogenic autoregulatory vasoconstriction to elicit relatively larger and more sustained increases in cutaneous flow during HDT. In the cheek, delayed myogenic vasoconstriction and/or hurmonal effects apparently compensated for flow elevation by 24 h of HDT. Therefore, localized vascular adaptations to gravity probably explain differences in acclimation of lower and upper body blood flow to HDT and actual microgravity.

Stout, M. Shannon↗

Porous and Microporous Honeycomb Composites as Potential Boundary-Layer Bleed Materials

Results of an experimental investigation are presented in which the use of porous and microporous honeycomb composite materials is evaluated as an alternate to perforated solid plates for boundary-layer bleed in supersonic aircraft inlets. The terms "porous" and "microporous," respectively, refer to bleed orifice diameters roughly equal to and much less than the displacement thickness of the approach boundary-layer. A Baseline porous solid plate, two porous honeycomb, and three microporous honeycomb configurations are evaluated. The performance of the plates is characterized by the flow coefficient and relative change in boundary-layer profile parameters across the bleed region. The tests were conducted at Mach numbers of 1.27 and 1.98. The results show the porous honeycomb is not as efficient at removing mass compared to the baseline. The microporous plates were about equal to the baseline with one plate demonstrating a significantly higher efficiency. The microporous plates produced significantly fuller boundary-layer profiles downstream of the bleed region for a given mass flow removal rate than either the baseline or the porous honeycomb plates.

Davis, D. O.↗

High Temperature Properties of an Alumina Enhanced Thermal Barrier

The heatshield material requirements for future space vehicles (Aerobraking Orbital Transfer Vehicle & National Aerospace Plane) will depend upon the desired flight capability, configuration and location on the vehicle. These requirements will be more demanding and different from those derived for the materials used in the Shuttle Orbiter thermal protection system. Research was therefore initiated into improving the thermal efficiency of this class of materials by first characterizing their thermal and structural capabilities. Alternate material systems have been developed, tested, and compared with the baseline Shuttle system. This research resulted in the development of several very low density, high porosity (80-90%) materials with enhanced durability and temperature capability. One of the developments was a family of materials referred to as Fibrous Refractory Composite Insulation (FRCI) utilizing a mixture of fibers, each serving a unique purpose. One composition of the FRCI family with two fibers was adopted as a baseline material for use on the third and fourth Orbiters in selected areas due to its strength at a lower density compared to earlier materials. A further improvement in the FRCI family of materials is the Alumina Enhanced Thermal Barrier (AETB), a three-fiber composite. It has a higher temperature capability (composition dependent) than the baseline FRCI as proven by convective heating tests of one composition. AETB was studied to better characterize its performance at high temperature and the mechanisms by which its properties change. In conclusion, the shrinkage of AETB is a factor of six better than baseline FRCI at 1260 C (2300 F) with about a 20% improvement in mechanical properties. This improvement could translate into a 110 C (200 F) higher temperature capability in use as a heat shield material, but further testing in a convective heating environment is required to determine the actual improvement attainable.

Leiser, Daniel B.↗

LWC and Temperature Effects on Ice Accretion Formation on Swept Wings at Glaze Ice Conditions

An experiment was conducted to study the effect of liquid water content and temperature on the critical distance in ice accretion formation on swept wings at glaze ice conditions. The critical distance is defined as the distance from the attachment line to tile beginning of the zone where roughness elements develop into glaze ice feathers. A baseline case of 150 mph, 25 F, 0.75 g/cu m. Cloud Liquid Water Content (LWC) and 20 micrometers in Water Droplet Median Volume Diameter (MVD) was chosen. Icing runs were performed on a NACA 0012 swept wing tip at 150 mph and MVD of 20 micrometers for liquid water contents of 0.5 g/cu m, 0.75 g/cu m, and 1.0 g/cu m, and for total temperatures of 20 F, 25 F and 30 F. At each tunnel condition, the sweep angle was changed from 0 deg to 45 deg in 5 deg increments. Casting data, ice shape tracings, and close-up photographic data were obtained. The results showed that decreasing the LWC to 0.5 g/cu m decreases the value of the critical distance at a given sweep angle compared to the baseline case, and starts the formation of complete scallops at 30 sweep angle. Increasing the LWC to 1.0 g/cu m increases the value of the critical distance compared to the baseline case, the critical distance remains always above 0 millimeters and complete scallops are not formed. Decreasing the total temperature to 20 F decreases the critical distance with respect to the baseline case and formation of complete scallops begins at 25 deg sweep angle. When the total temperature is increased to 30 F, bumps covered with roughness elements appear on the ice accretion at 25 deg and 30 deg sweep angles, large ice structures appear at 35 deg and 40 deg sweep angles, and complete scallops are formed at 45 deg sweep angle.

Vargas, Mario↗

Observations of Circumstellar Material Around Evolved Stars With the ISI

The U.C. Berkeley Infrared Spatial Interferometer (ISI) is a stellar interferometer operating in the 9-12 micron region and has been in operation from 1988 until the present. It utilizes heterodyne detection using CO2 laser local oscillators and currently includes two 1.65 m movable telescopes mounted in semi-trailers and baselines up to about 65 m in length. A third telescope is being integrated with the other two and within the next year will operate as an imaging interferometer providing data with three simultaneous baselines and a closure phase, and baselines up to about 75 m. During the past twelve years the ISI has been used extensively for studies of circumstellar material around evolved stars. Multi-epoch observations of a sample of prototypical sources have elucidated the location and time scales for dust formation around these stars. These time scales can be as short as approx.10 years for Mira stars and as long as approx. 100 years for supergiants. For stars like Mira itself there is evidence for departure from spherical symmetry and episodes of dust formation and destruction. For some stars motion of dust has been observed -- IK Tau is one example, and NML Cyg is another. The molecules Silane and Ammonia were observed for the extreme carbon star IRC +10216 and the supergiant VY CMa pinpointing their location relative to the inner radius of the dust shell. Somewhat surprisingly, these molecules were found to form many stellar radii away from the inner radius of the dust shell, implying that they form by interactions with the surfaces of dust grains. Last year observations with the longest baselines lead to new precision diameters of $o$ Ceti and $\alpha$ Orionis, and are continuing on a somewhat larger set of Mira variable and supergiant stars.

Danchi, W. C.↗

Acoustic Benefits of Stator Sweep and Lean for a High Tip Speed Fan

A model high-speed fan stage was acoustically tested in the NASA Glenn 9- by 15-Foot Low Speed Wind Tunnel at takeoff/approach flight conditions. The fan was designed for a corrected rotor tip speed of 442 m/s (1450 ft/s), and had a powered core, or booster stage, giving the model a nominal bypass ratio of 5. The model also had a simulated engine pylon and nozzle bifurcation contained within the bypass duct. The fan was tested with three stator sets to evaluate acoustic benefits associated with a swept and leaned stator and with a swept integral vane/frame stator which incorporated some of the swept and leaned features as well as eliminated some of the downstream support structure. The baseline fan with the wide chord rotor and baseline stator approximated a current GEAE CF6 engine. A flyover effective perceived noise level (EPNL) code was used to generate relative EPNL values for the various configurations. Flyover effective perceived noise levels (EPNL) were computed from the model data to help project noise benefits. A tone removal study was also performed. The swept and leaned stator showed a 3 EPNdB reduction at lower fan speeds relative to the baseline stator; while the swept integral vane/frame stator showed lowest noise levels at intermediate fan speeds. Removal of the bypass blade passage frequency rotor tone (BPF) showed a 4 EPNdB reduction for the baseline and swept and leaned stators, and a 6 EPNdB reduction for the swept integral vane/ frame stator. Therefore, selective tone removal techniques such as active noise control and/or tuned liner could be particularly effective in reducing noise levels for certain fan speeds.

Woodward, Richard P.↗

Failure Morphologies of Cyclically Oxidized ZrO2-Based Thermal Barrier Coatings

Advanced and baseline thermal barrier coatings (TBCs) were thermal cycle tested in air at 1163 C until delamination or spallation of the ceramic top coat. The top coat of the advanced TBC s consisted of ZrO2 with various amounts of Y2O3, Yb2O3, Gd2O3, or Nd2O3 dopants. The composition of the top coat of the baseline TBC was ZrO2-8wt.%Y2O3. All top coats were deposited by air plasma spraying. A NiCrAlY or NiCoCrAlY bond coat was deposited by low pressure plasma spraying onto a single-crystal, Ni-base superalloy. The TBC lifetime for the baseline coatings was approximately 190 cycles (45 minutes at 1163 C per cycle) while the lifetime for the advanced coatings was as high as 425 cycles. The fracture surfaces and sample cross sections were examined after TBC failure by SEM and optical microscopy, and the top coats were further examined by X-ray diffraction. These post-test studies revealed that the fracture path largely followed splat boundaries with some trans-splat fracture. However, there were no obvious distinguishing features which explained the difference in TBC lifetimes between some of the advanced and baseline coatings.

Nesbitt, James A.↗

The Noise of a Forward Swept Fan

A forward swept fan, designated the Quiet High Speed Fan (QHSF), was tested in the NASA Glenn 9-by 15-foot Low Speed Wind Tunnel to investigate its noise reduction relative to a baseline fan of the same aerodynamic performance. The objective of the Quiet High Speed Fan was a 6 decibel reduction in the Effective Perceived Noise relative to the baseline fan at the takeoff condition. The intent of the Quiet High Speed Fan design was to provide both a multiple pure tone noise reduction from the forward sweep of the fan rotor and a rotor-stator interaction blade passing tone noise reduction from a leaned stator. The tunnel noise data indicted that the Quiet High Speed Fan was quieter than the baseline fan for a significant portion of the operating line and was 6 dB quieter near the takeoff condition. Although reductions in the multiple pure tones were observed, the vast majority of the EPNdB reduction was a result of the reduction in the blade passing tone and its harmonics. The baseline fan's blade passing tone was dominated by the rotor-strut interaction mechanism. The observed blade passing tone reduction could be the result of either the redesign of the Quiet High Speed Fan Rotor or the redesigned stator. The exact cause of this rotor-strut noise reduction, whether from the rotor or stator redesign, was not discernable from this experiment.

Dittmar, James H.↗

Lumbar spine disc heights and curvature: upright posture vs. supine compression harness

INTRODUCTION: Spinal lengthening in microgravity is thought to cause back pain in astronauts. A spinal compression harness can compress the spine to eliminate lengthening but the loading condition with harness is different than physiologic conditions. Our purpose was to compare the effect of spine compression with a harness in supine position on disk height and spinal curvature in the lumbar spine to that of upright position as measured using a vertically open magnetic resonance imaging system. METHODS: Fifteen healthy subjects volunteered. On day 1, each subject lay supine for an hour and a baseline scan of the lumbar spine was performed. After applying a load of fifty percent of body weight with the harness for thirty minutes, the lumbar spine was scanned again. On day 2, after a baseline scan, a follow up scan was performed after kneeling for thirty minutes within the gap between two vertically oriented magnetic coils. Anterior and posterior disk heights, posterior disk bulging, and spinal curvature were measured from the baseline and follow up scans. RESULTS: Anterior disk heights increased and posterior disk heights decreased compared with baseline scans both after spinal compression with harness and upright posture. The spinal curvature increased by both loading conditions of the spine. DISCUSSION: The spinal compression with specially designed harness has the same effect as the physiologic loading of the spine in the kneeling upright position. The harness shows some promise as a tool to increase the diagnostic capabilities of a conventional MR system.

Non-NASA Center↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗