Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical Sciences Vistas: Perspectives on Simultaneous Excellence (Issue 1, 2023)

The issue begins with an article highlighting Physics Division’s involvement in diagnostic development that led to the measurement of ignition at the National Ignition Facility at Lawrence Livermore National Laboratory. Subsequent articles transition to some of the materials development occurring in Sigma, Materials Science and Technology, and Materials Physics and Applications divisions. This is inclusive of the development of next generation moderator materials as an enabling technology of small modular reactors. These materials will most likely be qualified at a facility at Idaho National Laboratory. The issue also highlights development of novel, additively manufactured foams for next generation weapons. This work is being done in close collaboration with the Kansas City National Security Campus to enable transition of materials development to production in a more agile way. Finally, an article describes Accelerator Operations and Technology Division’s hard work to replace the legacy remote instrumentation and control equipment at the Los Alamos Neutron Science Center (LANSCE) with a modern control system. The story discusses how that engineering success will lead to improved sustainability of the beam during operation and thus a better experience for all of our collaborators and partners in the LANSCE user program.

36 MATERIALS SCIENCE↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implications of gamma ray observations for particle acceleration Experimental prospects

The relationship of gamma ray observations to the energetic particle acceleration phenomena is discussed. In particular the requirements for production of gamma rays by energetic particles are reviewed. The present state of observations of gamma rays is also reviewed and where there is a clear connection, the implications for particle acceleration theory is pointed out. In conclusion, a brief summary is given for instrument capabilities for the next major USA satellite experiments to be conducted in the 1980s.

Chupp, E. L.↗

Miniature X-Ray Tubes

Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

Bearman, Gregory H.↗

A proof of concept investigation: A unique mobility spectrometer for In Situ diagnostics of positive and negative ion distributions in the mesosphere and lower ionosphere

We have carried out a proof-of-concept development and test effort that not only promises the reduction of parasitic effects of surface contamination (therefore increasing the integrity of 'in situ' measurements in the 60-130 km regime), but promises a uniquely expanded measurement set that includes electron densities, plasma conductivities, charged-particle mobilities, and mass discrimination of positive and negative ion distributions throughout the continuum to free-molecular-flow regimes. Three different sensor configurations were designed, built and tested, along with specialized driving voltage, electrometer and channeltron control electronics. The individual systems were tested in a variety of simulated space environments ranging from pressures near the continuum limit of 100 mTorr to the collisionless regime at 10(exp -6) Torr. Swept modes were initially employed to better understand ion optics and ion 'beam' losses to end walls and to control electrodes. This swept mode also helped better understand and mitigate the influences of secondary electrons on the overall performance of the PIMS design concept. Final results demonstrated the utility of the concept in dominant single-ion plasma environments. Accumulated information, including theoretical concepts and laboratory data, suggest that multi-ion diagnostics are fully within the instrument capabilities and that cold plasma tests with minimized pre-aperture sheath acceleration are the key ingredients to multi-ion success.

Szuszczewicz, Edward P.↗

The polar solar wind: An additional acceleration due to the rotation of the magnetic sun

The influence of the solar rotation of the polar solar wind acceleration was analyzed theoretically. Data from the Solar and Heliospheric Observatory (SOHO) ultraviolet instruments were used to test the theoretical predictions. These predictions are: the double electric layer at the heliocentric distance of 2.6 solar radii, and the system of field-aligned electric currents above 2.6 solar radii. The model provides a 3D analytical discontinuous stationary solution of the magnetohydrodynamic equations in the non-inertial frame of reference.

Pisanko, Y. V.↗

A Compact Dual-Crystal Modulated Birefringence-Measurement System for Microgravity Applications

A compact modulated birefringence-measurement system has been developed for use in microgravity fluid physics applications with non-Newtonian fluids such as polymer solutions. This instrument uses a dual-crystal transverse electro-optical modulator capable of modulation frequencies in excess of 100 MHz. The two crystals are modulated 180 deg. out of phase from each other, The theoretical framework governing the development of this instrument using the Mueller-Stokes polarization matrices is discussed. Several ground-based experiments are performed to compare this system with the theoretical results. Results from this transverse electro-optical modulator-based birefringence-measurement system agree well with the theory. The instrument is also very stable and robust, making it suitable for the extreme acceleration environment to be encountered in a NASA Black Brandt sounding rocket.

Mackey, Jeffrey R.↗

Cherenkov and Scintillation Properties of Cubic Zirconium

Cubic zirconium (CZ) is a high index of refraction (n =2.17) material that we have investigated for Cherenkov counter applications. Laboratory and proton accelerator tests of an 18cc sample of CZ show that the expected fast Cherenkov response is accompanied by a longer scintillation component that can be separated by pulse shaping. This presents the possibility of novel particle spectrometers which exploits both properties of CZ. Other high index materials being examined for Cherenkov applications will be discussed. Results from laboratory tests and an accelerator exposure will be presented and a potential application in solar energetic particle instruments will be discussed

Christl, M.J.↗

Instrument for Analysis of Greenland's Glacier Mills

A new instrument is used to study the inner workings of Greenland s glacier mills by riding the currents inside a glacier s moulin. The West Greenland Moulin Explorer instrument was deployed into a tubular shaft to autonomously record temperature, pressure, 3D acceleration, and location. It is built with a slightly positive buoyancy in order to assist in recovery. The unit is made up of several components. A 3-axis MEMS (microelectromechanical systems) accelerometer with 0.001-g resolution forms the base of the unit. A pressure transducer is added that is capable of withstanding 500 psi (=3.4 MPa), and surviving down to -40 C. An Iridium modem sends out data every 10 minutes. The location is traced by a GPS (Global Positioning System) unit. This GPS unit is also used for recovery after the mission. Power is provided by a high-capacity lithium thionyl chloride D-sized battery. The accelerometer is housed inside a cylindrical, foot-long (=30 cm) polyvinyl chloride (PVC) shell sealed at each end with acrylic. The pressure transducer is attached to one of these lids and a MEMS accelerometer to the other, recording 100 samples per second per axis.

Behar, Alberto E.↗

Modal Analysis and Model Correlation of the Mir Space Station

This paper will discuss on-orbit dynamic tests, modal analysis, and model refinement studies performed as part of the Mir Structural Dynamics Experiment (MiSDE). Mir is the Russian permanently manned Space Station whose construction first started in 1986. The MiSDE was sponsored by the NASA International Space Station (ISS) Phase 1 Office and was part of the Shuttle-Mir Risk Mitigation Experiment (RME). One of the main objectives for MiSDE is to demonstrate the feasibility of performing on-orbit modal testing on large space structures to extract modal parameters that will be used to correlate mathematical models. The experiment was performed over a one-year span on the Mir-alone and Mir with a Shuttle docked. A total of 45 test sessions were performed including: Shuttle and Mir thruster firings, Shuttle-Mir and Progress-Mir dockings, crew exercise and pushoffs, and ambient noise during night-to-day and day-to-night orbital transitions. Test data were recorded with a variety of existing and new instrumentation systems that included: the MiSDE Mir Auxiliary Sensor Unit (MASU), the Space Acceleration Measurement System (SAMS), the Russian Mir Structural Dynamic Measurement System (SDMS), the Mir and Shuttle Inertial Measurement Units (IMUs), and the Shuttle payload bay video cameras. Modal analysis was performed on the collected test data to extract modal parameters, i.e. frequencies, damping factors, and mode shapes. A special time-domain modal identification procedure was used on free-decay structural responses. The results from this study show that modal testing and analysis of large space structures is feasible within operational constraints. Model refinements were performed on both the Mir alone and the Shuttle-Mir mated configurations. The design sensitivity approach was used for refinement, which adjusts structural properties in order to match analytical and test modal parameters. To verify the refinement results, the analytical responses calculated using original and refined math models were compared with the measured responses. The results from this study show that the refined models predict more accurately the dynamics of the actual structure. The MiSDE test and analysis results provided the information and experience on test design, flight testing, and data analysis for the ISS and other future spacecraft, which are critical to the verification of analytical models and structural loads.

Kim, Hyoung M.↗

Full-Scale Passive Earth Entry Vehicle Landing Tests: Methods and Measurements

During the summer of 2016, a series of drop tests were conducted on two passive earth entry vehicle (EEV) test articles at the Utah Test and Training Range (UTTR). The tests were conducted to evaluate the structural integrity of a realistic EEV vehicle under anticipated landing loads. The test vehicles were lifted to an altitude of approximately 400m via a helicopter and released via release hook into a predesignated 61 m landing zone. Onboard accelerometers were capable of measuring vehicle free flight and impact loads. High-speed cameras on the ground tracked the free-falling vehicles and data was used to calculate critical impact parameters during the final seconds of flight. Additional sets of high definition and ultra-high definition cameras were able to supplement the high-speed data by capturing the release and free flight of the test articles. Three tests were successfully completed and showed that the passive vehicle design was able to withstand the impact loads from nominal and off-nominal impacts at landing velocities of approximately 29 m/s. Two out of three test resulted in off-nominal impacts due to a combination of high winds at altitude and the method used to suspend the vehicle from the helicopter. Both the video and acceleration data captured is examined and discussed. Finally, recommendations for improved release and instrumentation methods are presented.

Littell, Justin D.↗

BPM STABILTIY STUDIES FOR THE APS MBA UPGRADE

The Advanced Photon Source (APS) is currently in the preliminary design phase for the multi-bend achromat (MBA) lattice upgrade. Beam stability is critical for the MBA and will require long term drift defined as beam mo-tion over a seven-day timescale to be no more than 1 mi-cron at the insertion device locations and beam angle change no more than 0.25 micro-radian. Mechanical stabil-ity of beam position monitor (BPM) pickup electrodes mounted on insertion device vacuum chambers place a fun-damental limitation on long-term beam stability for inser-tion device beamlines. We present the design and imple-mentation of prototype mechanical motion system (MMS) instrumentation for quantifying this type of motion specif-ically in the APS accelerator tunnel and experiment hall floor under normal operating conditions. The MMS pres-ently provides critical position information on the vacuum chamber and BPM support systems. Initial results of the R&D prototype systems have demonstrated that the cham-ber movements far exceed the long-term drift tolerance specified for the APS Upgrade MBA storage ring.

Lill, R.↗

Impact of Varying Dark Energy on Future Large-Scale Structure Studies

The cosmos withholds multiple mysteries such as dark forms of matter and energy that are yet beyond human comprehension. In the standard cosmological model, $\Lambda$CDM, the cosmological constant $\Lambda$ is thought to be responsible for the late accelerated expansion of the Universe. However, recent results from the Dark Energy Spectroscopic Instrument (DESI) suggest the possibility of evolving dark energy, which warrants further exploration. Future surveys such as the Rubin Observatory Legacy Survey of Space and Time (LSST) will map the large-scale structure (LSS) with unprecedented precision, giving us valuable statistical information about the cosmos. The goal of this research is to investigate the potential impact of an evolving dark energy scenario on cosmological parameters constrained by LSS probes, as will be mapped by the LSST. For this, we examine the power spectra of lens galaxies, source galaxies, and cross-power spectra between lens galaxies and source galaxies. The combination of these statistics is commonly referred to as '3 $\times$ 2 points'. For this investigation, we created a set of simulations resembling LSST data and used them to perform cosmological parameter inference in two scenarios: one in which the simulated data is based on the fiducial model and another on evolving dark energy. We then examined the degeneracy between the cosmological parameters and checked for potential shifts in the parametric space when the data contains dynamical dark energy but the modeling assumes $\Lambda$CDM. Our findings indicate that mismodeling the dark energy equation of state can significantly impact parameter inference, particularly affecting the total matter density, $\Omega_m$, and the growth of structures, as represented by the $S_8$ parameter. These results highlight the importance of further exploring extensions of the $\Lambda$CDM model in future LSS studies.

Yaman Acharya, A.↗

Microwave induced plasma discharge in multi-cell superconducting radio-frequency cavity

A R&D effort for in situ cleaning of 1.5 GHz Superconducting Radio Frequency (SRF) cavities at room temperature using the plasma processing technique has been initiated at Jefferson Lab. This is a step toward the cleaning of cryomodules installed in the Continuous Electron Beam Accelerator Facility (CEBAF). For this purpose, we have developed an understanding of plasma discharge in a 5-cell CEBAF-type SRF cavity having configurations similar to those in the main accelerator. The focus of this study involves the detailed investigations of developing a plasma discharge inside the cavity volume and avoids the breakdown condition in the vicinity of the ceramic RF window. A plasma discharge of the gas mixture Ar–O{sub 2} (90%:10%) can be established inside the cavity volume by the excitation of a resonant 4π/5 TM{sub 010}-mode driven by a klystron. The absence of any external magnetic field for generating the plasma is suitable for cleaning cavities installed in a complex cryomodule assembly. The procedures developed in these experimental investigations can be applied to any complex cavity structure. Details of these experimental measurements and the observations are discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The High Intensity Horizon at Fermilab

Fermilab's high intensity horizon is 'Project-X' which is a US led initiative with strong international participation that aims to realize a next generation proton source that will dramatically extend the reach of Intensity Frontier research. The Project-X research program includes world leading sensitivity in long-baseline and short-baseline neutrino experiments, a rich program of ultra-rare muon and kaon decays, opportunities for next-generation electric dipole moment experiments and other nuclear/particle physics probes, and a platform to investigate technologies for next generation energy applications. A wide range of R&D activities has supported mission critical accelerator subsystems, such as high-gradient superconducting RF accelerating structures, efficient RF power systems, cryo-modules and cryogenic refrigeration plants, advanced beam diagnostics and instrumentation, high-power targetry, as well as the related infrastructure and civil construction preparing for a construction start of a staged program as early as 2017.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Teravolt-per-meter beam and plasma fields from low-charge femtosecond electron beams

Recent initiatives in ultra-short, GeV electron beam generation have been aimed at achieving sub-femtosecond (fs) pulses capable of driving X-ray free-electron lasers (FELs) in single-spike mode. This scheme foresees the use of very low charge beams, which may allow existing FEL injectors to produce few-100 as pulses, with very high brightness. Towards this end, recent experiments at SLAC have produced ~2 fs rms, low transverse emittance, 20 pC electron pulses. Here we examine the use of such pulses to excite plasma wakefields exceeding 1 TV/m, permitting a table-top TeV accelerator. Here, we present a scheme for focusing the beam to very small dimensions, where the surface Coulomb fields are also at the TV/m level. These conditions access a new regime for high field for atomic physics, allowing frontier atomic physics experiments such as barrier suppression regime ionization. They also, critically, permit well-sub-fs plasma formation for subsequent wake excitation. We examine the use of such ultra-short beams for creating coherent sub-cycle IR radiation at unprecedented high power levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced electron yield from laser-driven wakefield acceleration in high-Z gas jets

An investigation of the electron beam yield (charge) form helium, nitrogen, and neon gas jet plasmas in a typical laser-plasma wakefield acceleration experiment is carried out. The charge measurement is made by imaging the electron beam intensity profile on a fluorescent screen into a charge coupled device which was cross-calibrated with an integrated current transformer. The dependence of electron beam charge on the laser and plasma conditions for the aforementioned gases are studied. We found that laser-driven wakefield acceleration in low Z-gas jet targets usually generates high-quality and well-collimated electron beams with modest yields at the level of 10-100 pC. On the other hand, filamentary electron beams which are observed from high-Z gases at higher densities reached much higher yields. Evidences for cluster formation were clearly observed in the nitrogen gas jet target, where we received the highest electron beam charge of ∼1.7 nC. Those intense electron beams will be beneficial for the applications on the generation of bright X-rays, gamma rays radiations, and energetic positrons via the bremsstrahlung or inverse-scattering processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗