Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Impact of salinity on morphology, growth, and pigment profiles of Scenedesmus obliquus HTB1 under ambient air and elevated CO 2 (10 %) conditions

Certain microalgal species, such as Scenedesmus obliquus strain HTB1, thrive under high CO 2 concentrations, making them promising for carbon sequestration to mitigate climate change. Isolated from the Baltimore Inner Harbor, HTB1 grows faster with 10 % CO 2 than with ambient air. To investigate its responses to salinity and elevated CO 2 , two experiments were conducted. In the first, HTB1 was cultured at seven different salinities (0, 17.5, 20, 22.5, 25, 27.5, and 30 ppt) (parts per thousand) under ambient air. Higher salinity caused cell shrinkage, color changes from green to pale white, reduced pigments like zeaxanthin, lutein, and chlorophyll b, but increased canthaxanthin. Growth declined significantly above 22.5 ppt. The second experiment compared HTB1's response to salinity (0, 10, 20 ppt) under air and 10 % CO 2 . Cultures under 10 % CO 2 showed minimal color changes, while those under air shifted from green to brown, with salinity having less inhibitory effects on growth under elevated CO 2 . Interestingly, lutein and canthaxanthin levels rose with salinity in 10 % CO 2 . These findings indicate that elevated CO 2 mitigates salt stress in HTB1, reducing its impact on growth and promoting adaptive pigment changes. This study sheds light on how salinity and CO 2 interact to influence HTB1's morphology, growth, and pigment composition, enhancing our understanding of its resilience and potential applications.

20 FOSSIL-FUELED POWER PLANTS↗

Forecasting Peak Electricity Demand for Los Angeles Considering Higher Air Temperatures due to Climate Change

We report that Los Angeles County (LAC) is a large urbanized region with 9.7 million residents (as of 2010) and aging infrastructure. Population forecasts indicate that LAC will become home to an additional 1.2-3.1 million residents through 2060. Additionally, climate forecasts based upon representative concentration pathway (RCP) scenarios 4.5 and 8.5 indicate that average air temperatures will increase by 1-4 degrees C (2-7 degrees F) in the region. Both of these factors are expected to result in higher summertime peak electricity demand due to growth in the number of buildings, the percentage of installed air conditioners (ACs), and the additional cooling load on those air conditioners. In order to understand potential power reliability issues, and support infrastructure planning efforts, a long-term peak demand forecast was developed using hourly residential and commercial (R&C) building energy models. Peak hour electricity demand was estimated to increase from 9.5 to 12.8 GW for R&C sectors, to 13.0-17.3 GW (2-36%) and 14.7-19.2 GW (16-51%) by 2060 for the population forecasts from the California Department of Finance and the Southern California Association of Governments respectively. While marginal increases in ambient air temperature due to climate change accounted for only 4-8% of future increases in peak demand, differences in annual maximum temperatures within the 20-year periods affected results by 40-66% indicating a high sensitivity to heat waves. Population growth of at least 1 million people is anticipated to occur mostly in the northern cities of Palmdale, Lancaster, and Santa Clarita, bringing an additional 0.4-1 GW of peak demand in those regions. Building and AC efficiency are anticipated to improve as national and state efficiency standards increase, and as older, less efficient units are replaced; this could offset some of the projected increases in peak demand. Furthermore, development of shared wall, multi-family dwelling units could enable population growth of up to 3 million people without increasing peak demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Novel rapid oxidizing fusion method to determine Polonium-210 in air filters

A rapid method for the determination of polonium-210 in air filters has been created for use following a radiological event and for routine environmental monitoring. Air filter samples, including cellulose and glass fiber, are fused with a sodium or potassium nitrate/sodium hydroxide flux material. The alkaline matrix minimizes polonium volatility during sample digestion steps, while efficiently dissolving the air filter and inorganic matter implanted on the filter. The addition of nitrate to the flux destroys organic material which can decrease Polonium recovery during precipitation, extraction and source preparation steps. Polonium is concentrated and separated from the sample matrix using an iron hydroxide precipitation and extraction chromatography with DGA Resin. Polonium-210 is subsequently measured by alpha spectrometry following rapid microprecipitation with bismuth phosphate. The new method employs extraction chromatographic purification to remove alpha emitting interferences and sample matrix constituents which can interfere with 210 Po measurements using alpha spectrometry. The novel blend of sodium hydroxide and alkali metal nitrate digests the air filters quickly and effectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Degradation of ultra-thin boron films in air

Corrosion of B films in air can limit their practical applications. Here, we study the evolution of the elemental composition, thickness, and morphology of 10–100-nm-thick amorphous B films sputter-deposited onto glassy carbon substrates and stored under different conditions. Results show that films with thicknesses of ≳55 nm have expected excellent corrosion resistance during storage in laboratory air at room temperature over several months. In contrast, ≲45-nm-thick films exhibit pronounced degradation upon air exposure, starting with a change in the composition to ~30 and ~50 at.% of O and H, respectively. After such an O and H uptake, the degradation proceeds via mass loss with a characteristic time constant of ~5 days in air at room temperature. In conclusion, a post-deposition annealing at 1000 °C in an inert atmosphere makes all the films corrosion resistant.

36 MATERIALS SCIENCE↗

Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study of the Effect of Molecular and Aerosol Conditions in the Atmosphere on Air Fluorescence Measurements at the Pierre Auger Observatory

The air fluorescence detector of the Pierre Auger Observatory is designed to perform calorimetric measurements of extensive air showers created by cosmic rays of above 10^18 eV. To correct these measurements for the effects introduced by atmospheric fluctuations, the Observatory contains a group of monitoring instruments to record atmospheric conditions across the detector site, an area exceeding 3,000 km^2. The atmospheric data are used extensively in the reconstruction of air showers, and are particularly important for the correct determination of shower energies and the depths of shower maxima. This paper contains a summary of the molecular and aerosol conditions measured at the Pierre Auger Observatory since the start of regular operations in 2004, and includes a discussion of the impact of these measurements on air shower reconstructions. Between 10^18 and 10^20 eV, the systematic uncertainties due to all atmospheric effects increase from 4% to 8% in measurements of shower energy, and 4 g/cm^2 to 8 g/cm^2 in measurements of the shower maximum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio detection of air showers with the ARIANNA experiment on the Ross Ice Shelf

The ARIANNA hexagonal radio array (HRA) is an experiment in its pilot phase designed to detect cosmogenic neutrinos of energies above 10 16 eV. The most neutrino-like background stems from the radio emission of air showers. Here this article reports on dedicated efforts of simulating and detecting the signals of cosmic rays. A description of the fully radio self-triggered data-set, the properties of the detected air shower signals in the frequency range of 100–500 MHz and the consequences for neutrino detection are given. 38 air shower signals are identified by their distinct waveform characteristics, are in good agreement with simulations and their signals provide evidence that neutrino-induced radio signals will be distinguishable with high efficiency in ARIANNA. The cosmic ray flux at a mean energy of 6.5$_{-1.0}^{+1.2} $×10 17 eV is measured to be 1.1$_{-0.7}^{+1.0} $ ×10 -16 eV -1 km -2 sr -1 yr -1 and one five-fold coincident event is used to illustrate the capabilities of the ARIANNA detector to reconstruct arrival direction and energy of air showers.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooling efficiency of a spot-type personalized air-conditioner

Here, this study defined Cooling Efficiency ( CE ) of a Spot-type Personalized Air-Conditioning (SPAC) device as the ratio of the additional sensible heat removal from human body induced by SPAC and the device's cooling capacity. CE enabled the investigation of SPAC performance on the occupant's sensible heat loss (Q s ) and thermal sensation by its quantitative relation with the change of PMV level ( ΔPMV ). Three round nozzles with the diameter of 0.08 m, 0.105 m, and 0.128 m, respectively, discharged air jets at airflow rates from 11.8 L s –1 to 59.0 L s –1 , toward the chest of a seated or standing human body with a clothing of 0.48 clo. This study developed a validated CFD model coupled with the Fanger's thermoregulation model, to calculate Q s in a room of 26 °C ventilated at a rate of 3 ACH. According to the results, Q s , CE and draft risk ( DR ) at face had significant positive linear correlation with the SPAC device's supply airflow rates (R2 >0.96), and a negative linear correlation for ΔPMV. With DR = 20% at face, CE was always under 0.3, and ΔPMV was around -1.0–1.1. Interestingly, both CE and ΔPMV had the least favorable values for the air jet produced by the nozzle with the diameter of 0.105 m independent of body posture. In conclusion, although SPAC could lead to additional Q s by sending air at a higher airflow rate from a smaller nozzle, the improvement in cooling efficiency and thermal sensation had a limit due to draft risk.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of an inverse model of zone air heat balance

Our work introduces the validation method and results of an inverse model of zone air heat balance. The inverse model, implemented in EnergyPlus and published in a previous article [1], calculates highly uncertain model parameters such as internal thermal mass and infiltration airflow by inversely solving the zone air heat balance equation using the easy-to-measure zone air temperature data. The paper provides technical details of validation from the experiments using LBNL's Facility for Low Energy eXperiment in Buildings (FLEXLAB) that measures zone air temperature under the controlled experiment of two levels of internal mass and four levels of infiltration airflow. The simulation results of the zone infiltration airflow and internal thermal mass from the inverse model agree well with the measured data from the FLEXLAB experiments. The validated inverse model in EnergyPlus can be utilized to enhance the energy modeling of existing buildings that enables energy performance assessments for energy efficiency improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygro-thermo-mechanical modeling of partially saturated air-entrained concrete containing dissolved salt and exposed to freeze-thaw cycles

Highlights: • A model for cyclic freezing of air-entrained concrete containing salt is proposed. • The freeze-thaw hysteresis, also including the effect of dissolved salt, is modeled. • The diffusive and convective flux of salt is coupled to the freeze-thaw processes. • The freeze-thaw response of air-entrained concrete containing salt is reproduced. • Liquid absorption from reservoirs increases with an increased concentration of salt. In cold regions, understanding the freeze-thaw behavior of air-entrained concrete is important for designing durable structures and assessing the remaining service life of existing structures. This study presents a hygro-thermo-mechanical multiphase model that describes the cyclic freeze-thaw behavior of partially saturated air-entrained concrete containing dissolved salt. An equilibrium and a non-equilibrium approach are adopted to model the ice formation, including the freeze-thaw hysteresis, inside the porous network. The model also considers the diffusive and convective transport of the dissolved salt coupled to the freeze-thaw processes. Two examples are presented to verify and highlight the capabilities of the model. The first example shows that the model is capable of reproducing the experimentally observed mechanical response of specimens containing NaC1-solutions of different concentrations. In the second example, a larger absorption of liquid from an external reservoir is obtained with an increasing salt concentration in the reservoir, which is consistent with experimental observations.

36 MATERIALS SCIENCE↗

A new hypothesis for air loss in cement systems containing fly ash

Although there are many benefits gained from incorporating fly ash into concrete, carbon contamination in the fly ash has been shown to interfere with the efficacy of organic additives in an unpredictable manner. This work uses surface tension measurements to quantify the adsorption of air-entraining agents (AEA) onto cement and fly ash. Both the adsorption capacity of the adsorbents and the adsorption isotherms indicate that the fly ash particles, rather than the carbon itself, dominate adsorption in a carbon-contaminated ash in cement pore solution. We propose that adsorption onto fly ash particles and cement actually improve air entrainment via Pickering stabilization. While the carbon is still expected to contribute to air loss via hydrophobic adsorption of the surfactants, we suggest that the primary way in which the carbon interferes is by shielding surfactant-coated fly ash particles from participating in air development and Pickering stabilization during mixing.

36 MATERIALS SCIENCE↗

Techno-Economic Analysis of a Secondary Air Stripper Process

We present results of an initial techno-economic assessment on a post-combustion CO2 capture process developed by the Center for Applied Energy Research (CAER) at the University of Kentucky using Mitsubishi Hitachi Power Systems’ H3-1 aqueous amine solvent. The analysis is based on data collected at a 0.7 MWe pilot unit combined with laboratory data and process simulations. The process adds a secondary air stripper to a conventional solvent process, which increases the cyclic loading of the solvent in two ways. First, air strips additional CO2 from the solvent downstream of the conventional steam-heated thermal stripper. This extra stripping of CO2 reduces the lean loading entering the absorber. Second, the CO2-enriched air is then sent to the boiler for use as secondary air. This recycling of CO2 results in a higher concentration of CO2 in the flue gas sent to the absorber, and hence a higher rich loading of the solvent exiting the absorber. A process model was incorporated into a full-scale supercritical pulverized coal power plant model to determine the plant performance and heat and mass balances. The performance and heat and mass balance data were used to size equipment and develop cost estimates for capital and operating costs. Lifecycle costs were considered through a levelized cost of electricity (LCOE) assessment based on the capital cost estimate and modeled performance. The results of the simulations show that the CAER process yields a regeneration energy of 3.12 GJ/t CO2, a $53.05/t CO2 capture cost, and LCOE of $174.59/MWh. This compares to the U.S. Department of Energy’s projected costs (Case 10) of regeneration energy of 3.58 GJ/t CO2 , a $61.31/t CO2 capture cost, and LCOE of $189.59/MWh. For H3-1, the CAER process results in a regeneration energy of 2.62 GJ/tCO2 with a stripper pressure of 5.2 bar, a capture cost of $46.93/t CO2, and an LCOE of $164.33/MWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy performance of a bedroom task/ambient air conditioning (TAC) system applied in different climate zones of China

Here, task/ambient air conditioning (TAC) system applied to bedrooms has been investigated and its energy efficient performance reported. To promote the application of bedroom TAC to a larger region, a numerical study was carried out on a bedroom TAC system applied in five different climate zones. To simplify the numerical study, response surface methodology (RSM) was used to predict operating power of TAC based on CFD results. It's found that the daily energy consumption in the typical day was from 0 kWh in Kunming to 1.27 kWh in Shanghai, the averaged daily energy consumption varied from 0.47 kWh in June to 0.56 kWh in August for Guangzhou, and the total energy consumption in summer ranged from 0 kWh in Kunming to 58.33 kWh in Guangzhou. Meanwhile, the operating time of the TAC were also different between these five cities. In order to save energy, different set points of t oz (average air temperature in the occupied zone) were investigated. Additionally, it's found that increasing the t oz from 24 to 25 °C can reduce energy consumption by about 23.42% in Shanghai to 36.23% in Beijing. Besides, the energy saving potential using two operating modes were compared: variable air flow rate and variable air temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-term effects of air temperature on plasma metabolite concentrations in patients undergoing cardiac catheterization

Background: Epidemiological studies have shown associations between air temperature and cardiovascular health outcomes. Metabolic dysregulation might also play a role in the development of cardiovascular disease. Objectives: To investigate short-term temperature effects on metabolites related to cardiovascular disease. Methods: Concentrations of 45 acylcarnitines, 15 amino acids, ketone bodies and total free fatty acids were available in 2869 participants from the CATHeterization GENetics cohort recruited at the Duke University Cardiac Catheterization Clinic (Durham, NC) between 2001 and 2007. Ten metabolites were selected based on quality criteria and cluster analysis. Daily averages of meteorological variables were obtained from the North American Regional Reanalysis project. Immediate, lagged, and cumulative temperature effects on metabolite concentrations were analyzed using (piecewise) linear regression models. Results: Linear temperature effects were found for glycine, C16-OH:C14:1-DC, and aspartic acid/asparagine. A 5 °C increase in temperature was associated with a 1.8% [95%-confidence interval: 0.3%; 3.3%] increase in glycine (5-day average), a 3.2% [0.1%; 6.3%] increase in C16-OH:C14:1-DC (lag of four days), and a −1.4% [−2.4%; −0.3%] decrease in aspartic acid/asparagine (lag of two days). Non-linear temperature effects were observed for alanine and total ketone bodies with breakpoint of 4 °C and 20 °C, respectively. Both a 5 °C decrease in temperature on colder days (<4 °C)and a 5 °C increase in temperature on warmer days (≥4 °C) were associated with a four day delayed increase in alanine by 6.6% [11.7; 1.8%] and 1.9% [0.3%; 3.4%], respectively. For ketone bodies we found immediate (0-day lag) increases of 4.2% [−0.5%; 9.1%] and 12.3% [0.1%; 26.0%] associated with 5 °C decreases on colder (<20 °C) days and 5 °C increases on warmer days (≥20 °C), respectively. Conclusions: We observed multiple effects of air temperature on metabolites several of which are reported to be involved in cardiovascular disease. Our findings might help to understand the link between air temperature and cardiovascular disease. - Highlights: • Certain metabolites are assumed to be novel biomarkers for cardiovascular disease. • First study investigating associations between air temperature and metabolites. • Short-term effects of temperature on amino acids, ketone bodies and acylcarnitines. • Our findings may help to understand the link between temperature and cardiovascular disease.

60 APPLIED LIFE SCIENCES↗

Comparative Evaluation of Control-Oriented Heavy Duty Vehicle Air Drag Coefficient Models

Heavy-duty vehicles (HDVs) are a significant source of fuel consumption and greenhouse gas emissions, prompting solutions such as HDV platooning to mitigate these negative impacts through air drag reduction. The intervehicle distance in an HDV platoon needs to be carefully selected, such that the platoon-level energy efficiency and safety considerations can be well balanced. Underlying this problem lies in accurately modeling the relationship between HDV air drag coefficient and intervehicle distance. Through comprehensive evaluation and comparison, we analyze five control-oriented HDV air drag coefficient models, including the polynomial model, rational polynomial model, rational model, semi-quadratic model, and ridge model. Leveraging Scipy Curve-Fit toolbox and our previously compiled air drag coefficient datasets, we optimally identify the parameters inside each model. The calibrated models are then thoroughly evaluated via five complementary metrics. The comparison results reveal that the semi-quadratic model has the highest overall performance, while the widely adopted rational model only exhibits suboptimal performance.

Best, Micah↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

Fracture behavior of a melt-infiltration-processed SiC/Si composite at 900°C in argon, air, and steam

The fracture behavior of a melt-infiltration-processed SiC/Si composite, used to mimic the matrices of industrial fiber-reinforced ceramic composites, was examined in different atmospheres and temperatures. Specimens tested in four-point bending at 900 °C in oxygen-gettered argon, dry air, or steam-rich atmospheres exhibited higher average fracture strengths than specimens tested at 25°C. Higher mean fracture strength values were obtained for specimens tested in dry air or in a steam-rich atmosphere at 900°C than for specimens tested in high-purity, oxygen-gettered argon at this temperature. The increased fracture strengths obtained in air and in steam-rich atmospheres coincided with increased specimen oxidation and apparent oxide filling and blunting of flaws in these composites. Further, a transition in the location of catastrophic failure, from sites of preexisting damage created by Vickers indentations for tests in argon to other locations for tests in air or steam-rich atmospheres, was also consistent with such apparent oxide filling/blunting of indentation-induced flaws.

36 MATERIALS SCIENCE↗