Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “66”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Establishing Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory

Background: Promising developments in Pb-212 radiopharmaceutical therapies have increased demand for Pb-203 diagnostic agents. Building on previous work from various isotope production facilities, this study optimized Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory (BNL). The additional supply of Pb-203 may help meet growing preclinical and clinical demands. Results: Two Tl targets were irradiated at the Brookhaven Linac Isotope Producer facility with 30 ± 1 MeV protons, measured using previously published cross section data. Distribution coefficients for Pb Resin in acetate media were investigated for both Na + and K + cations, where potassium acetate was ~ 4 times more effective at stripping Pb from the Pb Resin. The Tl electrodeposition was optimized to deposit 350 mg of Tl (~ 60 mg/cm 2 ) on Au backing in under 6 h. The proposed separation process was completed in < 1.5 h and achieved > 98% and 92 ± 3% recovery of Tl and Pb, respectively, with an overall Tl-Pb separation factor of 6 × 10 5 . The experimentally measured half-life of Pb-203 was 52.4 ± 0.7 h, agreeing with 51.93 ± 0.02 h reported by the National Nuclear Data Center. The radioisotopic purity of the Pb fraction at 24 h post end of bombardment (EOB) from a 24 h irradiation was 66% Pb-203, 28% Pb-201, and 6% Pb-200. Following chemical separation, the Pb-203 produced in this work (21 MBq Pb-203 EOB) achieved apparent molar activities of 10 ± 5 and 0.9 ± 0.5 GBq/µmol for [ 203 Pb]Pb-DOTAM and [ 203 Pb]Pb-DO3A, respectively, decay corrected to EOB. Data derived from this work suggests BNL can produce > 10’s GBq Pb-203 with > 99% radiochemical and radioisotopic purity from Tl-205 for worldwide distribution. Conclusions: The production and separation of Pb-203 from natural Tl target material was successfully demonstrated at BNL. Existing methods were adapted and optimized for the facilities at BNL. Results from this work will guide future large-scale Pb-203 production opportunities at BNL for clinical applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Why Travel for Complex Cancer Surgery? Americans React to ‘Brand-Sharing’ Between Specialty Cancer Hospitals and Their Affiliates

Introduction: Leading cancer hospitals have increasingly shared their ‘brand’ with smaller hospitals through affiliations. Because each brand evokes a distinct reputation for the care provided, ‘brand-sharing’ has the potential to impact the public’s ability to differentiate the safety and quality within hospital networks. The general public was surveyed to determine the perceived similarities and differences in the safety and quality of complex cancer surgery performed at top cancer hospitals and their smaller affiliate hospitals. Methods: A national, web-based KnowledgePanel (GfK) survey of American adults was conducted. Respondents were asked about their beliefs regarding the quality and safety of complex cancer surgery at a large, top-ranked cancer hospital and a smaller, local hospital, both in the presence and absence of an affiliation between the hospitals. Results: A total of 1010 surveys were completed (58.1% response rate). Overall, 85% of respondents felt ‘motivated’ to travel an hour for complex surgery at a larger hospital specializing in cancer, over a smaller local hospital. However, if the smaller hospital was affiliated with a top-ranked cancer hospital, 31% of the motivated respondents changed their preference to the smaller hospital. When asked to compare leading cancer hospitals and their smaller affiliates, 47% of respondents felt that surgical safety, 66% felt guideline compliance, and 53% felt cure rates would be the same at both hospitals. Conclusions: Approximately half of surveyed Americans did not distinguish the quality and safety of surgical care at top-ranked cancer hospitals from their smaller affiliates, potentially decreasing their motivation to travel to top centers for complex surgical care.

60 APPLIED LIFE SCIENCES↗

A Phase 2 Study of Induction Chemotherapy Using Docetaxel, Cisplatin, and S-1 for Gastric Cancer with Peritoneal Metastasis (KUGC06)

Background: The authors previously showed the significant efficacy of S-1 plus cisplatin for gastric cancer with limited peritoneal metastasis. They conducted a phase 2 study to evaluate the safety and efficacy of induction chemotherapy using a docetaxel, cisplatin, and S-1 (DCS) triplet regimen to treat gastric cancer with peritoneal metastasis. Methods: The key eligibility criteria were gastric cancer with peritoneal metastasis or positive peritoneal cytology but no other distant metastases and capability of oral administration. The patients received three 28-day cycles of DCS (60 mg/m{sup 2} of cisplatin, 40 mg/m{sup 2} of docetaxel on day 1, and 80 mg/m{sup 2} of S-1 from day 1 to day 14), then underwent D2 gastrectomy if R0 was possible. The primary end point was the R0 resection rate. The sample size was determined to have 80% power for detecting a 20% improvement in the R0 resection rate over a 45% baseline for a one-tailed alpha of 0.1. Results: Among 30 enrolled patients, 24 completed three cycles of DCS. The most frequent grade 3 or 4 toxicity was neutropenia (60%). A complete response of peritoneal metastasis was observed in 16 patients, and 14 patients achieved R0 resection (47%; 95% confidence interval 28–66%). When the extent of peritoneal metastasis was classified as P0CY1, P1, P2, and P3 according to the Japanese classification, the R0 resection rates were respectively 63%, 60%, 46% and 0%. Conclusions: Induction chemotherapy with DCS is safe and can achieve R0 resection for some patients with limited peritoneal metastasis or positive peritoneal cytology. The efficacy, however, appears similar to that of S-1 plus cisplatin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laparoscopic Cytoreductive Surgery with Hyperthermic Intraperitoneal Chemotherapy (L-CRS/HIPEC) for Perforated Low-Grade Appendiceal Mucinous Neoplasm (LAMN II)

Introduction: Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS/HIPEC) is an established treatment for pseudomyxoma peritonei resulting from a perforated low-grade appendiceal mucinous neoplasm (LAMN II). In patients with localized disease, a laparoscopic procedure (L-CRS/HIPEC) can be undertaken. Methods: This video demonstrates L-CRS/HIPEC in a 66-year-old male who had previously undergone an appendicectomy for an LAMN II lesion. The preoperative computed tomography (CT) scan suggested disease localized to the right iliac fossa. However, laparoscopic assessment unexpectedly revealed disease in the pelvis and on the right hemidiaphragm and liver surface. Results: A technique for treating the thin film of mucin in the pelvis and on the right hemidiaphragm is demonstrated. The liver is mobilized to facilitate ablation of mucin on the serosal surface of the right lobe. Tips and tricks for starting the omentectomy, dealing with the vascular pedicle, and completing the dissection in the left upper quadrant are shown. The Peritoneal Cancer Index (PCI) score was 5 (3 for the right upper quadrant, 1 for the pelvis, 1 for the small bowel), and the cytoreduction score was CC-1. The operative duration was 8.5 h, and length of hospital stay was 5 days. The patient returned to work after 6 weeks. Discussion: L-CRS/HIPEC can be performed when patients are unexpectedly found to have disease, provided the appendiceal pathology is low grade and the PCI score is low. There are potential benefits to this approach, with a shorter length of hospital stay and faster functional recovery when compared with traditional open surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physician Knowledge of Breast Cancer Recurrence and Contralateral Breast Cancer Risk is Associated with Increased Recommendations for Contralateral Prophylactic Mastectomy: a Survey of Physicians at NAPBC-Accredited Centers

Background: Physician recommendation for contralateral prophylactic mastectomy (CPM) has been shown to influence whether a patient chooses CPM. Few studies have explored physician knowledge about contralateral breast cancer (CBC) and local recurrence (LR) risk and whether knowledge is associated with recommendation for CPM. Methods: We conducted a cross-sectional survey of physicians at National Accreditation Program for Breast Centers-accredited breast centers across the USA. Physician knowledge levels of CBC and LR were assessed and correlated with recommendations for CPM. Results: A total of 2412 physicians were surveyed with a 51% response rate (n = 1226). The results showed that 66% had correct knowledge about CBC risk and 57% had correct knowledge about LR. Moreover, 634 had high knowledge, viz. 176 (55.4%) breast surgeons, 171 (58.0%) medical oncologists, 196 (62.0%) radiation oncologists, and 72 (29.9%) plastic surgeons (p < 0.01). Compared with high knowledge, low knowledge was associated with favoring insurance coverage for patients at average CBC risk (53.8% vs. 39.8%, p < 0.01). Low knowledge was also associated with feeling that CPM was indicated in patients with high recurrence anxiety (39.2% vs. 28.9%), young patients with estrogen receptor (ER)-negative cancer (25.3% vs. 18.5%), and patients with two first-degree relatives with breast cancer (40.0% vs. 32.3%) (all p < 0.01). Multivariable analysis found physician type [odds ratio (OR) 3.76 for surgeons] and low knowledge (OR 1.46) to be significant independent predictors of favoring insurance coverage for CPM in patients at average risk. Conclusions: Physician knowledge about CBC and LR could be improved. Lower knowledge is associated with favorable physician recommendations for CPM. It is not clear whether improving physician knowledge will change recommendations for CPM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the Metabolic Costs of Heavy Military Backpacking

Existing predictive equations underestimate the metabolic costs of heavy military load carriage. Metabolic costs are specific to each type of military equipment, and backpack loads often impose the most sustained burden on the dismounted warfighter. This study aimed to develop and validate an equation for estimating metabolic rates during heavy backpacking for the US Army Load Carriage Decision Aid (LCDA), an integrated software mission planning tool. Thirty healthy, active military-age adults (3 women, 27 men; age, 25 ± 7 yr; height, 1.74 ± 0.07 m; body mass, 77 ± 15 kg) walked for 6–21 min while carrying backpacks loaded up to 66% body mass at speeds between 0.45 and 1.97 m·s -1 . A new predictive model, the LCDA backpacking equation, was developed on metabolic rate data calculated from indirect calorimetry. Model estimation performance was evaluated internally by k-fold cross-validation and externally against seven historical reference data sets. We tested if the 90% confidence interval of the mean paired difference was within equivalence limits equal to 10% of the measured metabolic rate. Estimation accuracy and level of agreement were also evaluated by the bias and concordance correlation coefficient (CCC), respectively. Estimates from the LCDA backpacking equation were statistically equivalent ( P < 0.01) to metabolic rates measured in the current study (bias, -0.01 ± 0.62 W·kg -1 ; CCC, 0.965) and from the seven independent data sets (bias, -0.08 ± 0.59 W·kg -1 ; CCC, 0.926). The newly derived LCDA backpacking equation provides close estimates of steady-state metabolic energy expenditure during heavy load carriage. These advances enable further optimization of thermal-work strain monitoring, sports nutrition, and hydration strategies.

59 BASIC BIOLOGICAL SCIENCES↗

Metabolic Costs of Walking with Weighted Vests

ABSTRACT Introduction The US Army Load Carriage Decision Aid (LCDA) metabolic model is used by militaries across the globe and is intended to predict physiological responses, specifically metabolic costs, in a wide range of dismounted warfighter operations. However, the LCDA has yet to be adapted for vest-borne load carriage, which is commonplace in tactical populations, and differs in energetic costs to backpacking and other forms of load carriage. Purpose The purpose of this study is to develop and validate a metabolic model term that accurately estimates the effect of weighted vest loads on standing and walking metabolic rate for military mission-planning and general applications. Methods Twenty healthy, physically active military-age adults (4 women, 16 men; age, 26 ± 8 yr old; height, 1.74 ± 0.09 m; body mass, 81 ± 16 kg) walked for 6 to 21 min with four levels of weighted vest loading (0 to 66% body mass) at up to 11 treadmill speeds (0.45 to 1.97 m·s −1 ). Using indirect calorimetry measurements, we derived a new model term for estimating metabolic rate when carrying vest-borne loads. Model estimates were evaluated internally byk-fold cross-validation and externally against 12 reference datasets (264 total participants). We tested if the 90% confidence interval of the mean paired difference was within equivalence limits equal to 10% of the measured walking metabolic rate. Estimation accuracy, precision, and level of agreement were also evaluated by the bias, standard deviation of paired differences, and concordance correlation coefficient (CCC), respectively. Results Metabolic rate estimates using the new weighted vest term were statistically equivalent (P< 0.01) to measured values in the current study (bias, −0.01 ± 0.54 W·kg −1 ; CCC, 0.973) as well as from the 12 reference datasets (bias, −0.16 ± 0.59 W·kg −1 ; CCC, 0.963). Conclusions The updated LCDA metabolic model calculates accurate predictions of metabolic rate when carrying heavy backpack and vest-borne loads. Tactical populations and recreational athletes that train with weighted vests can confidently use the simplified LCDA metabolic calculator provided as Supplemental Digital Content to estimate metabolic rates for work/rest guidance, training periodization, and nutritional interventions.

Sport Sciences↗

The Roles of Interface, Adherend, and Adhesive in Plasma- and Other-treated Joints of Metals and FRP Materials Under Shear Deformation

This work investigated the role of interface, adherend, and adhesive in adhesively-bonded metal-metal, metal-CFRTP, and CFRTP-CFRTP combinations with plasma-treated surfaces under shear deformation. To this end, aluminum alloys (AA5052 and AA6061) and short-carbon-fiber-reinforced polyamide 66 (CFRPA66) were used as examples and performed through single lap shear testing. The results showed that air plasma surface treatment can improve the shear behavior of adhesively-bonded AA5052-CFRPA66 and CFRPA66-CFRPA66 joints with about 20% enhanced lap shear strength compared to non-treated cases. Failure surface morphology of plasma-treated CFRPA66 adherend confirmed this improvement by showing an increased amount of adhesive failure than interfacial failure between CFRPA66 and adhesive. But this is not true for AA5052-AA6061 joints with plasma-treated surfaces exhibiting almost no enhanced lap shear strength. This study also showed the importance of selecting a proper surface modification method for the enhancement of adhesive-bonded structures under shear deformation through the analysis of the results in this study and in the literature. For fiber-reinforced polymers (FRPs), improving FRP/adhesive interface may be prioritized via different surface modification methods (e.g., plasma, chemical coating, etc.) than adhesive modification methods. However, for surface-cleaned metals, toughening adhesive via different enhancement methods (e.g., nano-particles, chemical enhancement, etc.) may be more important than improving metal/adhesive interface. These insightful results are valuable in the area of multi-materials joining.

Qiao, Yao↗

Adhesively-bonded Metal-CFRTP Bi-materials: Enhanced Crack Growth Resistance via Plasma and Quantified Fracture via Size Effect Method

This work investigated air plasma effect on the Mode I crack growth resistance of adhesively-bonded metal-CFRTP dissimilar joints by using aluminum alloy (AA6061) and short-carbon-fiber-reinforced polyamide 66 (CFRPA66) as an example, and the Double Cantilever Beam (DCB) fracture testing as an evaluation method. The results show that air plasma treatment can significantly improve the fracture resistance of adhesively-bonded AA6061-CFRPA66 dissimilar joints with about 140% enhanced Mode I fracture energy in maximum compared to non-treated ones. The quantified fracture energies from size effect method for both non-treated and plasma-treated cases are geometry-independent, whereas this is not true for modified beam theory causing geometry-dependent results. The foregoing improvement was confirmed from the failure surface morphology of plasma-treated specimens, showing fibers peeling off from CFRPA66 surface due to plasma-enhanced bonding between CFRPA66 and adhesive by the formation of covalent bonds at their interface. This study demonstrated air plasma as an efficient surface modification method to enhance the fracture resistance of adhesively-bonded metal-CFRTP dissimilar joints, and size effect method as a characterization method to properly quantify their fracture properties. These aspects are valuable in the area of multi-materials joining.

Plasma, Adhesive Bonding, Slow Crack Growth, fract↗

Enhanced lightning strike protection using vertically oriented carbon fiber melded with conventional carbon fiber-reinforced composite and its validation through damage analysis

Lightning strike protection (LSP) is one of the prime factors in aerospace and wind industries concerning safety, enhanced service life, and reduced downtime. To ensure better LSP, high electrical conductivity is required to dissipate the current, which is always a challenge for polymer composites due to the inherent insulating nature of the polymer matrix. Conventional carbon fiber-reinforced composites (CFRP) offer electrical conductivity in the planar direction while the vertical i.e. through-thickness conductivity still remains a challenge. Having been motivated by this fact, we have fabricated CFRP interleaved with vertically oriented CF (Z-fiber) for the lightning strike test (100 kA). A paint was applied to mimic the actual service condition of the composite laminates. We have prepared two Z-fiber composites: (a) Z-1 containing one Z-fiber layer on the top along with conventional CF layers and (b) Z-5 containing five interleaved Z-fiber layers and compared the properties with conventional CFRP (Z-0). Interestingly, even a single Z-fiber layer (Z-1) showed lower damage (visual damage diameter 22 mm) than Z-0 (visual damage diameter 26 mm). Z-5 displayed the lowest damage (visual damage diameter 16.7 mm), which was further confirmed by cross-sectional optical microscopy. Improved LSP was attributed to the higher through-thickness electrical conductivity in the case of Z-5 (9 times with respect to Z-0) reflecting a lower electrical anisotropy for Z-fiber composites. The residual mechanical property after the lightning test was analyzed through the flexural test, and the retention of flexural strength and modulus was 66% and 86%, respectively for Z-5 showing a significant improvement in comparison to Z-0 (>40% for both).

Saha, Subhabrata↗

ORNL_AISD_NiPt_108atoms

This dataset describes the nickel-platinum (NiPt) solid solution binary alloy, where the two constituent elements nickel (Ni) and platinum (Pt) are randomly placed on the face centered cubic (FCC) crystal structure, with the lattice constant of 3.840 angstroms. The dataset comprises data for crystal structures with 108 atoms with 1,900 configurations. The data set was generated for concentrations ranging from 0at% of Pt to 100at% of Pt in the NiPt binary system, with increasing the concentration of Pt in the system every 5at%. For each one of the chemical compositions, 100 random configurations were generated, each with a different random seed. Each of the output files contains the mass, type, atomic coordinates, energy per atom, and forces in x, y, and z directions respectively. For each atomic configuration, the output was collected every 150 steps during the minimization stage and every 1000 steps during the replica exchange stage. Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS) [1], which is a molecular dynamics code, was used to generate data for NiPt alloy. The simulation used the interatomic potential for NiPt binary system 'MEAM_LAMMPS_KimSeolJi_2017_PtNi__MO_020840179467_001' [3] from the OpenKIM library (Open Knowledgebase of Interatomic Models) [2]. This potential was developed based on the second nearest-neighbor modified embedded-atom method (2NN MEAM). The simulation process begins with the generation of the random NiPt structure and follows with the short minimization and replica exchange simulation. The minimization procedure adjusts atomic coordinates and performs energy minimization, which typically leads to a local potential energy minimum. The method used for the minimization was the conjugate gradient algorithm. A short replica exchange (parallel tempering) simulation involves four replicas (ensembles) of a system and follows the minimization stage. Multiple snapshots of the configuration were collected during the minimization and replica exchange stages. NiPt alloy is interesting due to its magnetic and charge transfer properties [4]. The data is provided in a compressed zipped folders atoms108.zip. The zipped folder contains the data structured in the following way: - Ni_ground_state.cfg --> atomic configuration for the pure nickel - Pt_ground_state.cfg --> atomic configuration for the pure platinum - Pt#_filtered --> folders containing atomic configurations for #at% concentration of platinum. The folder contains 100 atomic configurations, each saved in a subfolder - Each subfolder named config* is associated with a specific atomic configuration. Each of these subfolders contains files with .cfg format, corresponding to outputs for each atomic configuration The total number of atomic configurations contained in atoms108.zip is 66,132. This dataset is an extension to the dataset ORNL_AISD_NiPt [5] that has been previously released with crystal structures of 256 atoms, 864 atoms, and 2,048 atoms, with the same methodology for data collection. References [1] https://www.lammps.org/ [2] https://openkim.org/ [3] https://openkim.org/id/MEAM_LAMMPS_KimSeolJi_2017_PtNi__MO_020840179467_001 [4] El-Gendy, Ahmed A. and Hampel, Silke and Büchner, Bernd and Klingeler, Rüdiger, Tuneable magnetic properties of carbon-shielded NiPt-nanoalloys, RSC Adv., volume 6, issue 57, pages 52427-52433, 2016, The Royal Society of Chemistry, doi:10.1039/C6RA05910D [5] M. Karabin, M. Lupo Pasini, and M. Eisenbach. ORNL_AISD_NiPt. United States: N. p., 2023. Web. doi:10.13139/OLCF/1958172.

36 MATERIALS SCIENCE↗

Control and Information Systems for the National Ignition Facility

Orchestration of every National Ignition Facility (NIF) shot cycle is managed by the Integrated Computer Control System (ICCS), which uses a scalable software architecture running code on more than 1950 front-end processors, embedded controllers, and supervisory servers. The ICCS operates laser and industrial control hardware containing 66 000 control and monitor points to ensure that all of NIF’s laser beams arrive at the target within 30 ps of each other and are aligned to a pointing accuracy of less than 50 μm root-mean-square, while ensuring that a host of diagnostic instruments record data in a few billionths of a second. NIF’s automated control subsystems are built from a common object-oriented software framework that distributes the software across the computer network and achieves interoperation between different software languages and target architectures. A large suite of business and scientific software tools supports experimental planning, experimental setup, facility configuration, and post-shot analysis. Standard business services using open-source software, commercial workflow tools, and database and messaging technologies have been developed. An information technology infrastructure consisting of servers, network devices, and storage provides the foundation for these systems. Thus, this work is an overview of the control and information systems used to support a wide variety of experiments during the National Ignition Campaign.

42 ENGINEERING↗

Coupling buried etalon layers to an engraved metasurface for durable and large-aperture meta-optics

Many optical applications that could potentially benefit from the design flexibility provided by the metasurface approach are being prohibited by the limited scalability of the fabrication and the robustness of the end-result structures when using a resonant meta-elements-based approach. In this study, an alternative demonstrated approach with superior scalability and robustness is substrate-engraved metasurfaces, based on medium mixing homogenization, yet it suffers from very limited optical response. Here we propose advancing this approach by coupling the metasurface with buried etalon layers, leading to enhancement in the optical response. A transfer matrix analysis is used to study the parameter space, predicting that the patterned reflectance values range of a beam shaper could be raised from only 4% to 30% when the metasurface is engraved in silica, and even up to 66% when engraved into higher-index oxides. Using the method proposed here, the phase difference range across the metasurface could be increased by 0.4 radians beyond the range achievable by a metasurface engraved in silica and could reach even higher values when embedded in higher-index materials. Full-wave numerical simulations are used to demonstrate a cylindrical metareflector and a metalens, further validating the analysis.

47 OTHER INSTRUMENTATION↗

Balanced interferometric system for stability measurements

We describe two different, double-sided interferometer designs for measuring material stability. Both designs are balanced interferometers where the only optical path difference is the sample and the reference beams are located within the interferometer. One interferometer is a double-pass design, whereas the other is a single-pass system. Based on a tolerancing analysis, the single-pass system is less susceptible to initial component misalignment and motions during experiments. This single-pass interferometer was tested with an 86 nm thin-film silver sample for both short-term repeatability and long-term stability. In 66 repeatability tests of 30 min each, the mean measured drift rate was less than 1 pm/h rms. In two long-term tests (>9 h), the mean drift rate was less than 1.1 pm/h, which shows good agreement between the short- and long-term measurements. In these experiments, the mean measured length change was 2 nm rms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitive and single-shot OH and temperature measurements by femtosecond cavity-enhanced absorption spectroscopy

In many low-temperature plasmas (LTPs), the OH radical and temperature represent key properties of plasma reactivity. However, OH and temperature measurements in weakly ionized LTPs are challenging, due to the low concentration and short lifetime of OH and the abrupt temperature rise caused by fast gas heating. To address such issues, this Letter combined cavity-enhanced absorption spectroscopy (CEAS) with femtosecond (fs) pulses to enable sensitive single-shot broadband measurements of OH and temperature with a time resolution of ∼180 ns in LTPs. Such a combination leveraged several benefits. With the appropriately designed cavity, an absorption gain of ∼66 was achieved, enhancing the actual OH detection limit by ∼55× to the 10 11 cm -3 level (sub-ppm in this work) compared with single-pass absorption. Single-shot measurements were enabled while maintaining a time resolution of ∼180 ns, sufficiently short for detecting OH with a lifetime of ∼100 μs. With the broadband fs laser, ∼34,000 cavity modes were matched with ∼95 modes matched on each CCD pixel bandwidth, such that fs-CEAS became immune to the laser-cavity coupling noise and highly robust across the entire spectral range. Also, the broadband fs laser allowed simultaneous sensing of many absorption features to enable simultaneous multi-parameter measurements with enhanced accuracies.

Liu, Ning↗

Pectin Methylesterase and Pectin Remodelling Differ in the Fibre Walls of Two Gossypium Species with Very Different Fibre Properties

Pectin, a major component of the primary cell walls of dicot plants, is synthesized in Golgi, secreted into the wall as methylesters and subsequently de-esterified by pectin methylesterase (PME). Pectin remodelling by PMEs is known to be important in regulating cell expansion in plants, but has been poorly studied in cotton. In this study, genome-wide analysis showed that PMEs are a large multi-gene family (81 genes) in diploid cotton (Gossypium raimondii), an expansion over the 66 in Arabidopsis and suggests the evolution of new functions in cotton. Relatively few PME genes are expressed highly in fibres based on EST abundance and the five most abundant in fibres were cloned and sequenced from two cotton species. Their significant sequence differences and their stage-specific expression in fibres within a species suggest subspecialisation during fibre development. We determined the transcript abundance of the five fibre PMEs, total PME enzyme activity, pectin content and extent of de-methylesterification of the pectin in fibre walls of the two cotton species over the first 25–30 days of fibre growth. There was a higher transcript abundance of fibre-PMEs and a higher total PME enzyme activity in G. barbadense (Gb) than in G. hirsutum (Gh) fibres, particularly during late fibre elongation. Total pectin was high, but de-esterified pectin was low during fibre elongation (5–12 dpa) in both Gh and Gb. De-esterified pectin levels rose thereafter when total PME activity increased and this occurred earlier in Gb fibres resulting in a lower degree of esterification in Gb fibres between 17 and 22 dpa. Gb fibres are finer and longer than those of Gh, so differences in pectin remodelling during the transition to wall thickening may be an important factor in influencing final fibre diameter and length, two key quality attributes of cotton fibres.

59 BASIC BIOLOGICAL SCIENCES↗

Single Cell Genomics of Uncultured, Health-Associated Tannerella BU063 (Oral Taxon 286) and Comparison to the Closely Related Pathogen Tannerella forsythia

The uncultivated bacterium Tannerella BU063 (oral taxon 286) is the closest relative to the periodontal pathogen Tannerella forsythia, but is not disease-associated itself. Using a single cell genomics approach, we isolated 12 individual BU063 cells by flow cytometry, and we amplified and sequenced their genomes. Comparative analyses of the assembled genomic scaffolds and their gene contents allowed us to study the diversity of this taxon within the oral community of a single human donor that provided the sample. Eight different BU063 genotypes were represented, all about 5% divergent at the nucleotide level. There were 2 pairs of cells and one group of three that were more highly identical, and may represent clonal populations. We did pooled assemblies on the nearly identical genomes to increase the assembled genomic coverage. The presence of a set of 66 ‘‘core’’ housekeeping genes showed that two of the single cell assemblies and the assembly derived from the three putatively identical cells were essentially complete. As expected, the genome of BU063 is more similar to Tannerella forsythia than any other known genome, although there are significant differences, including a 44% difference in gene content, changes in metabolic pathways, loss of synteny, and an 8–9% difference in GC content. Several identified virulence genes of T. forsythia are not found in BU063 including karilysin, prtH, and bspA. The absence of these genes may explain the lack of periodontal pathogenesis by this species and provides a new foundation to further understand the genome evolution and mechanisms of bacterial-host interaction in closely related oral microbes with different pathogenicity potential.

59 BASIC BIOLOGICAL SCIENCES↗

Representing Kidney Development Using the Gene Ontology

Gene Ontology (GO) provides dynamic controlled vocabularies to aid in the description of the functional biological attributes and subcellular locations of gene products from all taxonomic groups (www.geneontology.org). Here we describe collaboration between the renal biomedical research community and the GO Consortium to improve the quality and quantity of GO terms describing renal development. In the associated annotation activity, the new and revised terms were associated with gene products involved in renal development and function. This project resulted in a total of 522 GO terms being added to the ontology and the creation of approximately 9,600 kidney-related GO term associations to 940 UniProt Knowledgebase (UniProtKB) entries, covering 66 taxonomic groups. We demonstrate the impact of these improvements on the interpretation of GO term analyses performed on genes differentially expressed in kidney glomeruli affected by diabetic nephropathy. In summary, we have produced a resource that can be utilized in the interpretation of data from small- and large-scale experiments investigating molecular mechanisms of kidney function and development and thereby help towards alleviating renal disease.

59 BASIC BIOLOGICAL SCIENCES↗