Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind_speed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Simulation of Wind Turbine Performance and Loading Patterns using a Coupled Meso-scale/Micro-scale Flow Analysis Model

HELIOS simulations were conducted for the WPS-30 turbine from the Sexbierum experimental site. The MMCI module was used to include the effects of the atmospheric boundary layer using the strategy described in the methodology section. In Figure 1 , the thrust and power variation for the WRF/Helios (Meso-scale/micro-scale simulation) is compared with measured power and stand-alone Helios computations (uniform inflow). The unsteady variations in power and thrust caused by the turbulent inflow conditions is clearly evident from these figures. Note that the mean hub height velocity could not be exactly matched to the uniform inflow values of 8 m/s because of constraints in adjusting the geostrophic wind and roughness length in Meso-scale WRF simulations. The offset in mean power and thrust notable in the figures are because of the small difference in the mean wind speed. Nonetheless, these results provide proof-of-concept of the integrated Meso-scale/Micro-scale simulation capability developed as part of this work. To further substantiate the effects of turbulent inflow, flow visualizations (iso-surfaces of vorticity overlaid on contours of velocity magnitude) are shown in Figure 2 . Meandering of the vortex wake and eventual breakdown are observed in the flow visualizations. Vortex breakdown is observed to occur between 1.5 and 2.5 diameter distance from the turbine. In uniform inflow (not shown here), the vortex wake persists to much longer distance of about 5 diameters before beginning to breakdown. It is expected that the vortex breakdown will be strongly correlated with the turbulence intensity of the inflow. The capability developed herein provides enabling technology for analyzing and characterizing such effects.

17 WIND ENERGY↗

Dry Deposition Velocity Estimation for the Savannah River Site: Part 2 -- Parametric and Site-Specific Analysis

Values for the dry deposition velocity of airborne particles were estimated with the GENII Version 2.10.1 computer code for the Savannah River site using assumptions about surface roughness parameters and particle size and density. Use of the GENII code is recommended by the U.S. Department of Energy for this purpose. Meteorological conditions evaluated include atmospheric stability classes D, E, and F and wind speeds of 0.5, 1.0, 1.5, and 2.0 m/s. Local surface roughness values ranging from 0.03 to 2 meters were evaluated. Particles with mass mean diameters of 1, 5, and 10 microns and densities of 1, 3, 4, and 5 g/cm3 were evaluated. Site specific meteorology was used to predict deposition velocity for Savannah River conditions for a range of distances from 670 to 11,500 meters.

54 ENVIRONMENTAL SCIENCES↗

Rapid Debris Analysis Project Task 3 Final Report - Sensitivity of Fallout to Source Parameters, Near-Detonation Environment Material Properties, Topography, and Meteorology

This report describes the sensitivity of predicted nuclear fallout to a variety of model input parameters, including yield, height of burst, particle and activity size distribution parameters, wind speed, wind direction, topography, and precipitation. We investigate sensitivity over a wide but plausible range of model input parameters. In addition, we investigate a specific example with a relatively narrow range to illustrate the potential for evaluating uncertainties in predictions when there are more precise constraints on model parameters.

58 GEOSCIENCES↗

Saint Joseph's University Institute for Environmental Stewardship

Task A: Examination of the physiological, morphological, and reproductive responses of Panicum virgatum (switchgrass) cultivars identified as potential biofuel producing cultivars as well as naturally-occurring varieties of switchgrass to projected changes in climate for the central portion of the United States. This project was a multi-year project set in a field site located at the Konza Prairie Biological Station near Manhattan, KS USA. The major objective of the study was to understand the physiological and growth responses of the important biofuel grass species, Panicum virgatum (switch grass) to simulated changes in precipitation expected for the Central Plains region of the United States. Population level adaptation to broad-scale regional climates or within-population variation in genome size of this genetically and phenotypically diverse C4 grass species may influence the responses to future precipitation variability associated with climate change. Therefore, we investigated switchgrass responses to water variability between natural populations collected across latitudinal gradient and populations. P. virgatum plants from natural populations originating from Kansas, Oklahoma, and Texas received frequent, small precipitation events (“ambient’) or infrequent, large precipitation events (‘altered”) to simulate contrasting rainfall variability expected from this region. We measured leaf-level physiology, aboveground biomass varied significantly by population origin but did not differ by genome size. Our results suggest that trait variation in P. virgatum is primarily attributed to population-level adaptation across latitudinal gradient, not genome size, and that neither population-level adaptation nor genome size may be important predictors of P. virgatum responses to future climatic conditions. Based solely on the data presented here, the most important consideration when deciding what varieties of switchgrass to cultivate for biofuel feedstocks under future climate scenarios is local adaptation and not necessarily genome size as has been hypothesized in the literature. Task B: Installation of an extensive green roof system on the Science Center at Saint Joseph's University for research, research-training and educational outreach activities. An experimental green roof system was designed and installed by an outside contractor (Roofmeadows) on the roof of the Science Center at Saint Joseph's University. The roof system includes four test plots, each with a different drainage system, instrumentation to monitor storm water retention, roof deck temperature, heat flux into and out of the building, rain fall, wind speed and direction, relative humidity and heat emission from the roof system. The vegetative roof was planted with 26 species of plants, distributed throughout the roof area, to assess species/variety growth and coverage characteristics, both in terms of the different drain layer systems, and in terms of the different exposures along the north to south axis of the building. Analysis of the drain layer performance, in terms of storm water retention, shows that the aggregate (stone) drainage layer system performed the best, with the moisture management mat system second, and the geotextile drain layer and reservoir sheet layer systems coming in last. This information is of value in the planning and design of vegetative roof systems since the different types of drainage layer systems have different installation costs and different weights. The different drainage layer systems also seem to be having an impact on plant growth and spread with the test plot with the reservoir sheet layer actually having the poorest plant coverage and plant spread of all areas of the roof studied. Plant growth performance analysis is ongoing, but significant differences have been observed in the third growing season ('13) along the north to south axis, with most species doing better towards the northern end of the roof (in terms of percent ground coverage and plant spread and reproduction). Interestingly, plant growth in all four of the test plots was reduced relative to the lower areas of the roof (the lower area was ca. 2 inches lower than the test plots, due to the space needed for sensors under the plots. The lower roof area uses an aggregate drain layer comparable to that in the third test plot), even when accounting for the north to south differences. The reasons for these differences are not clear and studies are underway to examine the impact of wind scour, drainage rates, temperature, and other factors. This information will be of value to planners of extensive vegetative roof systems in the Philadelphia (and broader) region, since plant growth and roof system overall performance is influenced by local climate, making broad generalizations of performance difficult. Task C: Education and community outreach efforts by the IES involving conferences at SJU, presentations by faculty and students off campus, and educational signage. The Institute for Environmental Stewardship hosted three storm water management workshops on the SJU campus in Philadelphia, in collaboration with the Lower Merion Conservancy, a not-for-profit organization located in Montgomery County, PA. These workshops were free and open to the public. The three workshops (held each year in March) drew more than 200 participants total. The presenters included local and state government agencies, not for profit organizations involved in storm water and open space preservation, designers, engineers, planners and others. Feedback was uniformly positive and we plan to continue the workshops for the foreseeable future. Educational signage has been installed at four locations on campus to explain campus infrastructure related to storm water (rain gardens, vegetative roof and green facades), as well as detailed signage installed on the Science Center roof for the vegetative roof system. More than 100 people (from in and outside of SJU) have thus far participated in tours of the roof system. A digital signage system has been installed in the adjacent library and this system provides information about the vegetative roof project and other efforts. A web camera system for the roof has also been installed and the video will be simulcast to the digital signage and with web site (www.sju.edu/ies) in the near future.

09 BIOMASS FUELS↗

Dynamic Factor Graphs: A New Wind Power Forecasting Approach

Wind energy production is characterized by high uncertainty due to the random nature of wind speed, which is weather dependent. Thus, in power systems with a significant penetration of wind generators, the problem of studying the impact of wind farms on the performance of these systems has to be considered in detail and requires the availability of accurate wind power forecasting methods. In addition, the time horizons to be taken into account as references for such studies are becoming more and more variable (from a few hours to a few days) due to the needs of liberalized electricity markets.

Silva, Cátia↗

U.S. Virgin Islands Wind Resources Update 2014

This report summarized the data collected from two 60-meter (m) meteorological towers (met masts or met towers) and three sonic detection and ranging (SODAR) units on St. Thomas and St. Croix in 2012 and 2013. These results are an update to the previous feasibility study; the collected data are critical to the successful development of a wind project at either site (Lantz et al. 2012). The wind maps for the territory were updated based on these improved data. The National Renewable Energy Laboratory (NREL) conducted measurements from met towers and SODAR units for several locations in the U.S. Virgin Islands (USVI). Both met masts were deployed for more than a year and produced high-quality data (standard industry practice in the wind industry). The Longford (St. Croix) and Bovoni (St. Thomas) sites are estimated to have long-term corrected wind speeds that exceed 7 meters per second (m/s), which may produce financially viable wind projects for both sites. The levelized cost of energy for both sites was estimated at $\$$0.08–$\$$0.14 per kilowatt-hour for typical utility-scale wind turbine with the uncertainty in the estimate driven by uncertainty in the installed capital costs of the proposed wind farms. These estimates assume that the wind production tax credit is not reinstated, but that accelerated depreciation is in place.

17 WIND ENERGY↗

Atmospheric Response to Weddell Sea Open-Ocean Polynya

The atmospheric conditions associated with the rare Weddell Sea open ocean polynya are investigated. The polynya has not been seen since 1976, so data on the event is scarce. The CESM high resolution model is used to investigate multiple atmospheric variables. We analyze three years of polynyas, which are also compared to three years without a polynya. The surface temperature, sensible heat flux, latent heat flux, humidity, average wind speed, precipitation, longwave flux, and shortwave flux all increased over the polynya. The sensible heat flux had a higher magnitude than the latent heat flux because conduction and convection were the primary drivers of heat flux. A combination of increased latent heat flux and humidity led to an increase in precipitation. Increased longwave downwelling flux over the polynya indicated the presence of clouds over the polynya. Lastly, the sea level pressure was consistently lower over the polynya because of the presence of a thermal low generated by thermally driven convective updrafts.

58 GEOSCIENCES↗

2014 Wind Technologies Market Report

According to the 2014 Wind Technologies Market Report, total installed wind power capacity in the United States grew at a rate of eight percent in 2014, bringing the United States total installed capacity to nearly 66 gigawatts (GW), which ranks second in the world and meets 4.9 percent of U.S. end-use electricity demand in an average year. In total, 4,854 MW of new wind energy capacity were installed in the United States in 2014. The 2014 Wind Technologies Market Report also finds that wind energy prices are at an all-time low and are competitive with wholesale power prices and traditional power sources across many areas of the United States. Additionally, a new trend identified by the 2014 Wind Technologies Market Report shows utility-scale turbines with larger rotors designed for lower wind speeds have been increasingly deployed across the country in 2014. The findings also suggest that the success of the U.S. wind industry has had a ripple effect on the American economy, supporting 73,000 jobs related to development, siting, manufacturing, transportation, and other industries.

17 WIND ENERGY↗

Multifunctional Integrated Sensors (MFISES)

Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and the real world applications of the sensors systems.

42 ENGINEERING↗

Development of a MEMS dual-axis differential capacitance floating element shear stress sensor

A single-axis MEMS wall shear stress sensor with differential capacitive transduction method is produced. Using a synchronous modulation and demodulation interface circuit, the system is capable of making real time measurements of both mean and fluctuating wall shear stress. A sensitivity of 3.44 mV/Pa is achieved, with linearity in response demonstrated up to testing limit of 2 Pa. Minimum detectable signals of 340 μPa at 100 Hz and 120 μPa at 1 kHz are indicated, with a resonance of 3.5 kHz. Multiple full scale wind tunnel tests are performed, producing spectral measurements of turbulent boundary layers in wind speeds ranging up to 0.5 Ma (18 Pa of mean wall shear stress). The compact packaging allows for minimally invasive installation, and has proven relatively robust over multiple testing events. Temperature sensitivity, likely due to poor CTE matching of packaged materials, is an ongoing concern being addressed. These successes are being directly leveraged into a development plan for a dual-axis wall shear stress sensor, capable of producing true vector estimates at the wall.

47 OTHER INSTRUMENTATION↗

Optimized Sampling Strategies For Non-Proliferation Monitoring: Report

Concentration data collected from the 2013 H-Canyon effluent reprocessing experiment were reanalyzed to improve the source term estimate. When errors in the model-predicted wind speed and direction were removed, the source term uncertainty was reduced to 30% of the mean. This explained the factor of 30 difference between the source term size derived from data at 5 km and 10 km downwind in terms of the time history of dissolution. The results show a path forward to develop a sampling strategy for quantitative source term calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tonopah Test Range Air Monitoring. CY2014 Meteorological, Radiological, and Airborne Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This test resulted in radionuclide-contaminated soils at Clean Slate I, II, and III. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III and at the TTR Range Operations Control center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soils beyond both the physical and administrative boundaries of the sites. Results for the calendar year (CY) 2014 monitoring are: (1) the gross alpha and gross beta values from the monitoring stations are approximately equivalent to the highest values observed during the CY2014 reporting at the surrounding Community Environmental Monitoring Program (CEMP) stations; (2) only naturally occurring radionuclides were identified in the gamma spectral analyses; (3) the ambient gamma radiation measurements indicate that the average annual gamma exposure is similar at all three monitoring stations and periodic intervals of increased gamma values appear to be associated with storm fronts passing through the area; and (4) the concentrations of both resuspended dust and saltated sand particles generally increase with increasing wind speed. Differences in the observed dust concentrations are likely the result of differences in the soil characteristics immediately adjacent to the monitoring stations. Neither the resuspended particulate radiological analyses nor the ambient gamma radiation measurements suggest wind transport of radionuclide-contaminated soils.

54 ENVIRONMENTAL SCIENCES↗

Advanced Offshore Wind Turbine/Foundation Concept for the Great Lakes

This project investigated a conceptual 2-bladed rotor wind turbine design and assessed its feasibility for installation in the Great Lakes. The levelized cost of energy was used for this purpose. A location in Lake Erie near the coast of Cleveland, Ohio was selected as the application site. The loading environment was defined using wind and wave data collected at a weather station in Lake Erie near Cleveland. In addition, the probability distributions of the annual significant wave height and wind speed were determined. A model of the dependence of the above two quantities was also developed and used in the study of wind turbine system loads. Loads from ice floes and ridges were also included.The NREL 5 MW 3-bladed rotor wind turbine concept was used as the baseline design. The proposed turbine design employs variable pitch blade control with tip-brakes and a teeter mechanism. The rotor diameter, rated power and the tower dimensions were selected to closely match those of the NREL 5 MW wind turbine.A semi-floating gravity base foundation was designed for this project primarily to adapt to regional logistical constraints to transport and install the gravity base foundation. This foundation consists of, from bottom to top, a base plate, a buoyancy chamber, a taper zone, a column (with ice cone), and a service platform. A compound upward-downward ice cone was selected to secure the foundation from moving because of ice impact.The turbine loads analysis was based on International ElectroTechnical Committee (IEC) Standard 61400-1, Class III winds. The NREL software FAST was the primary computational tool used in this study to determine all design load cases. An initial set of studies of the dynamics of wind turbines using Automatic Dynamic Analysis of Mechanical Systems (ADAMS) demonstrated that FAST and ADAMS load predictions were comparable. Because of its relative simplicity and short run times, FAST was selected for this study. For ice load calculations, a method was developed and implemented in FAST to extend its capability for ice load modeling.Both upwind and downwind 2-bladed rotor wind turbine designs were developed and studied. The new rotor blade uses a new twist angle distribution design and a new pitch control algorithm compared with the baseline model. The coning and tilt angles were selected for both the upwind and downwind configurations to maximize the annual energy production. The risk of blade-tower impact is greater for the downwind design, particularly under a power grid fault; however, this risk was effectively reduced by adjusting the tilt angle for the downwind configuration.

17 WIND ENERGY↗

Analysis of Debris Trajectories at the Scaled Wind Farm Technology (SWiFT) Facility

Sandia National Laboratories operates the Scaled Wind Farm Technology Facility (SWiFT) on behalf of the Department of Energy Wind and Water Power Technologies Office. An analysis was performed to evaluate the hazards associated with debris thrown from one of SWiFT’s operating wind turbines, assuming a catastrophic failure. A Monte Carlo analysis was conducted to assess the complex variable space associated with debris throw hazards that included wind speed, wind direction, azimuth and pitch angles of the blade, and percentage of the blade that was separated. In addition, a set of high fidelity explicit dynamic finite element simulations were performed to determine the threshold impact energy envelope for the turbine control building located on-site. Assuming that all of the layered, independent, passive and active engineered safety systems and administrative procedures failed (a 100% failure rate of the safety systems), the likelihood of the control building being struck was calculated to be less than 5/10,000 and ballistic simulations showed that the control building would not provide passive protection for the majority of impact scenarios. Although options exist to improve the ballistic resistance of the control building, the recommendation is not to pursue them because there is a low probability of strike and there is an equal likelihood personnel could be located at similar distances in other areas of the SWiFT facility which are not passively protected, while the turbines are operating. A fenced exclusion area has been created around the turbines which restricts access to the boundary of the 1/100 strike probability. The overall recommendation is to neither relocate nor improve passive protection of the control building as the turbine safety systems have been improved to have no less than two independent, redundant, high quality engineered safety systems. Considering this, in combination with a control building strike probability of less than 5/10,000, the overall probability of turbine debris striking the control building is less than 1/1,000,000.

17 WIND ENERGY↗

SWiFT site atmospheric characterization

Historical meteorological tall tower data are analyzed from the Texas Tech University 200 m tower to characterize the atmospheric trends of the Scaled Wind Farm Technologies (SWiFT) site. In this report the data are analyzed to reveal bulk atmospheric trends, temporal trends and correlations of atmospheric variables. Through this analysis for the SWiFT turbines the site International Electrotechnical Commission (IEC) classification is determined to be class III-C. Averages and distributions of atmospheric variables are shown, revealing large fluctuations and the importance of understanding the actual site trends as opposed to simply using averages. The site is significantly directional with the average wind speed from the south, and particularly so in summer and fall. Site temporal trends are analyzed from both seasonal (time of the year) to daily (hour of the day) perspectives. Atmospheric stability is seen to vary most with time of day and less with time of year. Turbulence intensity is highly correlated with stability, and typical daytime unstable conditions see double the level of turbulence intensity versus that experienced during the average stable night. Shear, veer and atmospheric stability correlations are shown, where shear and veer are both highest for stable atmospheric conditions. An analysis of the Texas Tech University tower anemometer measurements is performed which reveals the extent of the tower shadow effects and sonic tilt misalignment.

17 WIND ENERGY↗

Project 57 Air Monitoring Report: October 1, 2013, through December 31, 2014

On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley north east of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DoD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a nonnuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DoD. Various radiological surveys have been performed in the area and in 2007, the DOE expanded the demarked contamination area by posting signs 200 to 400 feet (60 to 120 meters) outside of the original fence. Plutonium in soil is thought to attach preferentially to smaller particles. Therefore, redistribution of soil particulates by wind (dust) is the mechanism most likely to transport plutonium beyond the boundary of the Project 57 contamination area. In 2011, DRI installed two instrumentation towers to measure radiological, meteorological, and dust conditions. The monitoring activity was implemented to determine if radionuclide contamination was detectable in samples of airborne dust and characterize meteorological and environmental parameters that influence dust transport. Collected data also permits comparison of radiological conditions at the Project 57 monitoring stations to conditions observed at Community Environmental Monitoring Program (CEMP) stations around the NTTR. Biweekly samples of airborne particulates are submitted for laboratory assessment of gross alpha and gross beta radioactivity and for determination of gamma-emitting radionuclides. Annual average gross alpha values at the Project 57 monitoring stations are in the same range as the highest two values reported for the CEMP stations surrounding the NTTR. Annual average gross beta values at the Project 57 monitoring stations are slightly higher than the lowest value reported for the CEMP stations surrounding the NTTR. Gamma spectroscopy analyses on samples collected from the Project 57 stations identified only naturally occurring radionuclides. No manmade radionuclides were detected. Thermoluminescent dosimeters (TLDs) indicated that the average annual radioactivity dose at the monitoring stations is higher than the dose determined at surrounding CEMP stations but approximately half of the estimated national average dose received by the general public as a result of exposure to natural sources. The TLDs at the Project 57 monitoring stations are exposed to both natural sources (terrestrial and cosmic) and radioactive releases from the Project 57 contamination area. These comparisons show that the gross alpha, gross beta, and gamma spectroscopy levels at the Project 57 monitoring stations are similar to levels observed at the CEMP stations but that the average annual dose rate is higher than at the CEMP stations. Winds in excess of approximately 15 mph begin to generate dust movement by saltation (migration of sand at the ground surface) or direct suspension in the air. Saltated sand, PM10 (inhalable) dust, and PM2.5 (fine particulate dust) exhibit an approximately exponential increase with increasing wind speed. The greatest concentrations of dust occur for winds exceeding 20 mph. During the reporting period, winds in excess of 20 mph occurred approximately 1.6 percent of the time. Preliminary assessment of individual wind events suggests that dust generation is highly variable likely because of the influence of other meteorological and environmental parameters. Although winds sufficient to generate significant amounts of dust occur at the Project 57 site, they are infrequent and of short duration. Additionally, the potential for wind transport of dust is dependent on other parameters whose influence have not yet been assessed.

54 ENVIRONMENTAL SCIENCES↗

Marine Ice Nuclei Collections – MAGIC (MAGIC-IN) Final Campaign Summary

This campaign augmented measurements obtained via deployment of the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s ARM Mobile Facility (AMF) in the Marine ARM GPCI1 Investigation of Clouds (MAGIC) field campaign. The measurements, comprised of shipboard aerosol collections obtained during the five legs of the summer 2013 cruises, were sent for offline processing to measure ice nucleating particle (INP) number concentrations. The forty-three sample periods each represented, nominally, 24-hour segments during outbound and inbound transits of the Horizon Spirit. The samples were collected at locations between Los Angeles and Hawaii. Eight samples have been analyzed for immersion freezing temperature spectra thus far, using funding from other grants. Remaining samples are being frozen until support for further processing is obtained. Future analyses will investigate the inorganic/organic proportions of ice nuclei, in addition to determining the genetic composition of the overall biological community associated with INPs. Resulting correlations will be compared with other archived aerosol quantities, meteorological and ocean data (e.g., temperature, wind speed, sea surface temperature, etc…) and satellite ocean color products. These findings will ultimately aid in parameterizing oceanic (e.g., sea spray) INP emissions in regional and global scale models, when illustrating aerosol connections to cloud phases and properties. Independent future analyses of frozen filter samples, as proposed by collaborating investigators at the time of this report, will include single particle analyses of marine boundary layer aerosol compositions and morphology. The MAGIC-IN data are considered representative of the oligotrophic, low Chlorophyll-a (with the exception of near-shore) ocean regions, which exist along the MAGIC transect. Current analyses suggest that INP numbers in the marine boundary layer over this region are typically low, compared to existing measurements over marine areas and those collected in the laboratory as the result of realistic sea spray particle generation. These findings, along with separate studies, confirm the existence of highly variable emission sources for INP from oceans, (though weaker than land-based emissions at modestly cooled temperatures).

54 ENVIRONMENTAL SCIENCES↗

Microclimate Influence on Bird Arrival Behavior Field Campaign Report

Using our own prototype sensor arrays that were deployed to collect microclimate data, we were able to visualize distinct differences in temperature, wind speed, and humidity over very small ranges of distance. We collected data across four polygons within the Barrow Environmental Observatory site. Our prototype microclimate arrays were based on an Arduino microcontroller, DS18B20 temperature sensors, DHT11 relative humidity/temperature sensors, and Vernier anemometers. Data were obtained in a small grid pattern with four sensors spaced 60 cm apart along the x-axis, and moved at 60 cm increments along a y-line across a polygon. Overlaying bird nest location with such data has allowed us to better answer our research question, “How do Arctic birds choose where to nest to maximize fitness in harsh Arctic environments?”

54 ENVIRONMENTAL SCIENCES↗