Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Characterization of an 8-cm Diameter Ion Source System

Results of tests characterizing an 8-cm diameter ion source are presented. The tests were conducted in three separate vacuum test facilities at the University of Alabama-Huntsville, Colorado State University, and L3 Communications' ETI division. Standard ion optics tests describing electron backstreaming and total-voltage-limited impingement current behavior as a function of beam current were used as guidelines for selecting operating conditions where more detailed ion beam measurements were performed. The ion beam was profiled using an in-vacuum actuating probe system to determine the total ion current density and the ion charge state distribution variation across the face of the ion source. Both current density and ExB probes were utilized. The ion current density data were used to obtain integrated beam current, beam flatness parameters, and general beam profile shapes. The ExB probe data were used to determine the ratio of doubly to singly charged ion current. The ion beam profile tests were performed at over six different operating points that spanned the expected operating range of the DAWN thrusters being developed at L3. The characterization tests described herein reveal that the 8-cm ion source is suitable for use in (a) validating plasma diagnostic equipment, (b) xenon ion sputtering and etching studies of spacecraft materials, (c) plasma physics research, and (d) the study of ion thruster optics at varying conditions.

Li, Zhongmin↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

Compact and Integrated Liquid Bismuth Propellant Feed System

Operation of Hall thrusters with bismuth propellant has been shown to be a promising path toward high-power, high-performance, long-lifetime electric propulsion for spaceflight missions [1]. There has been considerable effort in the past three years aimed at resuscitating this promising technology and validating earlier experimental results indicating the advantages of a bismuth-fed Hall thruster. A critical element of the present effort is the precise metering of propellant to the thruster, since performance cannot be accurately assessed without an accurate accounting of mass flow rate. Earlier work used a pre./post-test propellant weighing scheme that did not provide any real-time measurement of mass flow rate while the thruster was firing, and makes subsequent performance calculations difficult. The motivation of the present work is to develop a precision liquid bismuth Propellant Management System (PMS) that provides hot, molten bismuth to the thruster while simultaneously monitoring in real-time the propellant mass flow rate. The system is a derivative of our previous propellant feed system [2], but the present system represents a more compact design. In addition, all control electronics are integrated into a single unit and designed to reside on a thrust stand and operate in the relevant vacuum environment where the thruster is operating, significantly increasing the present technology readiness level of liquid metal propellant feed systems. The design of various critical components in a bismuth PMS are described. These include the bismuth reservoir and pressurization system, 'hotspot' flow sensor, power system and integrated control system. Particular emphasis is given to selection of the electronics employed in this system and the methods that were used to isolate the power and control systems from the high-temperature portions of the feed system and thruster. Open loop calibration test results from the 'hotspot' flow sensor are reported, and results of integrated thruster/PMS tests demonstrate operation of the feed system in the relevant environment.

Polzin, Kurt A.↗

Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals

SPring-8 standard double-crystal monochromators containing water-cooled crystals were stabilized to a sufficient level to function as a part of optics components to supply stable microfocused x-ray beams, by determining causes of the instability and then removing them. The instability was caused by two factors--thermal deformation of fine stepper stages in the monochromator, which resulted in reduction in beam intensity with time, and vibrations of coolant supply units and vacuum pumps, which resulted in fluctuation in beam intensity. We remodeled the crystal holders to maintain the stage temperatures constant with water, attached x-ray and electron shields to the stages in order to prevent their warming up, introduced accumulators in the water circuits to absorb pressure pulsation, used polyurethane tubes to stabilize water flow, and placed rubber cushions under scroll vacuum pumps. As a result, the intensity reduction rate of the beam decreased from 26% to 1% per hour and the intensity fluctuation from 13% to 1%. The monochromators were also modified to prevent radiation damage to the crystals, materials used as a water seal, and motor cables.

43 PARTICLE ACCELERATORS↗

Self-neutralized ion beam

A vacuum arc ion source provides high current beams of metal ions that have been used both for accelerator injection and for ion implantation, and in both of these applications the degree of space charge neutralization of the beam is important. In accelerator injection application, the beam from the ion source may be accelerated further (post-acceleration), redirected by a bending magnet(s), or focused with magnetic or electrostatic lenses, and knowledge of the beam space charge is needed for optimal design of the optical elements. In ion implantation application, any build-up of positive charge in the insulating targets must be compensated by a simultaneous flux of cold electrons so as to provide overall charge neutrality of the target. We show that in line-of-sight ion implantation using a vacuum arc ion source, the high current ion beam carries along its own background sea of cold electrons, and this copious source of electrons provides a ''self-neutralizing'' feature to the beam. Here we describe experiments carried out in order to demonstrate this effect, and we provide an analysis showing that the beam is space-charge-neutralized to a very high degree.

43 PARTICLE ACCELERATORS↗

Piezoelectrically Enhanced Photocathodes

Doping of photocathodes with materials that have large piezoelectric coefficients has been proposed as an alternative means of increasing the desired photoemission of electrons. Treating cathode materials to increase emission of electrons is called "activation" in the art. It has been common practice to activate photocathodes by depositing thin layers of suitable metals (usually, cesium). Because cesium is unstable in air, fabrication of cesiated photocathodes and devices that contain them must be performed in sealed tubes under vacuum. It is difficult and costly to perform fabrication processes in enclosed, evacuated spaces. The proposed piezoelectrically enhanced photocathodes would have electron-emission properties similar to those of cesiated photocathodes but would be stable in air, and therefore could be fabricated more easily and at lower cost. Candidate photocathodes include nitrides of elements in column III of the periodic table . especially compounds of the general formula Al(x)Ga(1.x)N (where 0< or = x < or =.1). These compounds have high piezoelectric coefficients and are suitable for obtaining response to ultraviolet light. Fabrication of a photocathode according to the proposal would include inducement of strain in cathode layers during growth of the layers on a substrate. The strain would be induced by exploiting structural mismatches among the various constituent materials of the cathode. Because of the piezoelectric effect in this material, the strain would give rise to strong electric fields that, in turn, would give rise to a high concentration of charge near the surface. Examples of devices in which piezoelectrically enhanced photocathodes could be used include microchannel plates, electron- bombarded charge-coupled devices, image tubes, and night-vision goggles. Piezoelectrically enhanced photocathode materials could also be used in making highly efficient monolithic photodetectors. Highly efficient and stable piezoelectrically enhanced, ultraviolet-sensitive photocathodes and photodetectors could be fabricated by use of novel techniques for growing piezoelectrically enhanced layers, in conjunction with thinning and dopant-selective etching techniques.

Beach, Robert A.↗

Blue emission of Eu 2+ -doped translucent alumina

Inorganic scintillators are very important in medical and industrial measuring systems in the detection and measurement of ionizing radiation. In addition to Ce 3+ , a widely used dopant ion in oxide scintillators, divalent Europium (Eu 2+ ) has shown promise as a high-luminescence, fast-response luminescence center useful in the detection of ionizing radiation. In this research, aluminum oxide (Al 2 O 3 ) was studied as a host material for the divalent europium ion. Polycrystalline samples of Eu 2+ -doped translucent Al 2 O 3 were fabricated, and room temperature luminescence behavior was observed. Al 2 O 3 ceramics doped with 0.1 at% Eu 2+ were fabricated with a relative density of 99.75% theoretical density and in-line transmittance of 22% at a wavelength of 800 nm. The ceramics were processed by a gel-casting method, followed by sintering under high vacuum. The gelling agent, a copolymer of isobutylene and maleic anhydride, is marketed under the commercial name ISOBAM, and has the advantage of simultaneously acting as both a gelling agent and as a dispersant. The microstructure and composition of the vacuum-sintered Eu 2+ :Al 2 O 3 were characterized by Scanning Electric Microscopy (SEM), Transmission Electron Microscopy (TEM), and Energy-dispersive X-ray spectroscopy (EDS). The phase composition was determined by X-ray diffraction measurements (XRD) combined with Rietveld analysis. The photoluminescence behavior of the Eu 2+ :Al 2 O 3 was characterized using UV light as the excitation source, which emitted blue emission at 440 nm. The radio-luminescence of Eu 2+ :Al 2 O 3 was investigated by illumination with X-ray radiation, showing three emission bands at 376 nm, 575 nm and 698 nm. Furthermore, multiple level traps at different depths were detected in the Eu 2+ :Al 2 O 3 by employing thermoluminescence measurements.

36 MATERIALS SCIENCE↗

Observation of Beam ION Instability in Spear3

Weak vertical coupled bunch instability with oscillation amplitude at {mu}m level has been observed in SPEAR3. The instability becomes stronger when there is a vacuum pressure rise by partially turning off vacuum pumps and it becomes weaker when the vertical beam emittance is increased by turning off the skew quadrupole magnets. These confirmed that the instability was driven by ions in the vacuum. The threshold of the beam ion instability when running with a single bunch train is just under 200 mA. This paper presents the comprehensive observations of the beam ion instability in SPEAR3. The effects of vacuum pressure, beam current, beam filling pattern, chromaticity, beam emittance and bunch-by-bunch feedback are investigated in great detail. In an electron accelerator, ions generated from the residual gas molecules can be trapped by the beam. Then these trapped ions interact resonantly with the beam and cause beam instability and emittance blow-up. Most existing light sources use a long single bunch train filling pattern, followed by a long gap to avoid multi-turn ion trapping. However, such a gap does not preclude ions from accumulating during one passage of the single bunch train beam, and those ions can still cause a Fast Ion Instability (FII) as predicted by Raubenheimer and Zimmermann. FII has been observed in ALS, and PLS by artificially increasing the vacuum pressure by injecting helium gas into the vacuum chamber or by turning off the ion pumps in order to observe the beam ion instability. In some existing rings, for instance B factory, the beam ion instability was observed at the beginning of the machine operation after a long period of shutdown and then it automatically disappeared when the vacuum was better. However, when the beam emittance becomes smaller, the FII can occur at nominal conditions as observed in PLS, SOLEIL and SSRF. This paper reports the observations of beam ion instabilities in SPEAR3 under different condition during a period of one year, which includes single bunch train instability (FII) and multi-bunch train instability. Note that the instability may be not the same even with the same beam due to the change of the vacuum with time. SPEAR3 has a circumference of 234 m with a harmonic number of 372. SPEAR3 runs with six bunch train filling pattern in order to suppress the possible beam ion instability. Table 1 lists the main parameters of SPEAR3. The vacuum of SPEAR3 ranges from 0.1 to 0.5 nTorr, which varies from section to section.

43 PARTICLE ACCELERATORS↗

Chemical Free Surface Processing for High Gradient Superconducting RF Cavities

Chemical treatment such as buffered chemical polishing (BCP) or electro polishing (EP) followed by high pressure rinsing (HPR) of niobium (Nb) superconducting RF (SRF) cavities is expensive and complex multistep process. Furthermore, the cavity RF surfaces after the treatment still have numerous bubbles and pits that result from welding. These quench-producing weld defects together with the particulate contamination, result in significant scatter of the multi-cell Nb SRF cavities performance characteristics. This scatter is the major problem in the current manufacturing of the Nb SRF cavities. When developed the chemical free surafce processing using IEB will benefit first J-lab's CEBAF and Fermilab's Project X. Also, light sources, require 1.3 - 1.5 GHz SRF structures. Furthermore, IEB will produce much broader impact because it can be implemented into manufacturing of many other types of RF devices including both superconducting as well as normal conducting RF cavities. This program will develop a new process that will enhance quality of the superconducing radio-frequency cavities and allow acceleration of charged particles to much higher energies. The process also will improve the cavity manufacturing and result in substantial cost reduction of superconducting radio-frequency high-energy particle accelerators. Niobium samples were successfully processed by a DC electron beam to a degree that is suitable for the interior surface of an SRF cavity. To accomplish this, a complete system was developed from the ground up. A vacuum chamber system was acquired and adapted to act as the vessel for performing the Nb processing experiments. An extremely robust high voltage power supply was developed and manufactured to provide the power necessary to drive the multi-kW DC electron gun. A high voltage isolation filament transformer was also designed and manufactured to provide the necessary current to drive the filament within the electron gun. Finally, a beam melt characterization DC electron gun was created. This gun was used to explore the parameter space of interest for processing Nb SRF cavities. The beam melt characterization tests concluded that multiple quick passes at moderate beam power provided the most ideal melt zone characteristics Nb surfaces. It was also found that excellent melt and polish results could be achieved at lower voltages than originally conceived, getting the great results at a beam voltage of 20kV versus the 50kV used in the initial Phase I testing at Jefferson Laboratory. Operating at 20kV will also greatly reduce the challenges of designing a compact DC electron gun for processing of complete Nb SRF cavities, which will be done in Phase III. This final report is divided in eight parts which cover the major investigation work and results which have been performed and achieved. The first part addresses the design, fabrication and testing of the vacuum chamber. In the second part, the DC power supply output circuit design is presented for providing an operating space of 50-60kV with currents from 20-160mA and short and open circuit fault modes are considered and resolved. The third section covers testing and commissioning of the high voltage step up transformer and 150kV isolation transformer. Section four covers the design, construction and performance for a 100kV high voltage bushing. Section number five treats the filament design and load testing. Section number six covers electron gun design and simulation of electron beam melting. Section seven presents the beam target design, assembly and testing and test gun with solenoid magnet, design, fabrication and testing. Finally, section eight demonstrates electron beam melting and polishing of Nb, Cu and SS samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Auger electron spectroscopy study of surface-preparation contaminants

There are many cleaning techniques that are presently being employed for surface preparation of materials that are subsequently exposed to ultrahigh vacuum (UHV). Unfortunately, there are virtually no comparative measurements which establish the residual contaminant level of each method. In this report, eleven different cleaning methods, ranging from only detergent cleaning to electrochemical polishing, were applied to identical samples of 347 stainless steel. Two surface conditions, a standard machined surface and a mechanically polished surface, were studied. Auger electron spectroscopy (AES) within a UHV environment was then used to detect the types of contaminants and the magnitudes found on the sample surfaces. It was found that the electrochemical polishing gave the least contaminated surface of all metals studied and that mechanically polished surfaces were significantly cleaner than the as-machined surfaces for any given cleaning method. Furthermore, it was also found that the residual contaminations left by methanol, ethanol, isopropyl alcohol, acetone, and freon finishing rinses are almost the same.

Wu, D.↗

Ultradoping Boron on Si(100) via Solvothermal Chemistry

Ultradoping introduces unprecedented dopant levels into Si, which transforms its electronic behavior and enables its use as a next-generation electronic material. Commercialization of ultradoping is currently limited by gas-phase ultra-high vacuum requirements. Solvothermal chemistry is amenable to scale-up. However, an integral part of ultradoping is a direct chemical bond between dopants and Si, and solvothermal dopant-Si surface reactions are not well-developed. This work provides the first quantified demonstration of achieving ultradoping concentrations of boron (~1e14 cm 2 ) by using a solvothermal process. Surface characterizations indicate the catalyst cross-reacted, which led to multiple surface products and caused ambiguity in experimental confirmation of direct surface attachment. Density functional theory computations elucidate that the reaction results in direct B-Si surface bonds. Finally, this proof-of-principle work lays groundwork for emerging solvothermal ultradoping processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Substrate-Mediated Evaporation and Stochastic Evolution of Supported Au Nanoparticles

Here, we use in situ transmission electron microscopy with automated tracking to study supported gold nanoparticles (NPs) during high-temperature vacuum annealing. The average mass loss per NP is governed by a flat, nearly size-independent substrate-mediated evaporation profile. On top of this mean shrinkage, individual NPs show significant fluctuations in apparent growth or shrinkage, and NP volume follows a random-walk-like trajectory. To rationalize both the ensemble-mean behavior and the particle-resolved variability, we develop a self-consistent theory that couples substrate-mediated evaporation to collective 2D Ostwald-type mass exchange through a shared adatom field, described in terms of a renormalized screening length and background concentration. In the experimentally relevant regime, the theory predicts an approximately size-independent mean shrinkage rate and clarifies how net mass loss suppresses classical coarsening. Superimposed on this deterministic drift, we quantify stochastic volume trajectories and capture their fluctuation spectrum with a minimal Langevin description consistent with intermittent adatom attachment and detachment events. In addition, we characterize the lateral diffusive motion of NPs, which is responsible for their coalescence. Altogether, our results highlight that stochasticity is intrinsic at the nanoscale and that predicting the evolution of supported NPs at early and intermediate times requires a unified framework combining substrate-mediated evaporation, collective mass exchange, and stochastic fluctuations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Beating absorption in solid-state high harmonics

Since the new millennium coherent extreme ultra-violet and soft x-ray radiation has revolutionized the understanding of dynamical physical, chemical and biological systems at the electron’s natural timescale. Unfortunately, coherent laser-based upconversion of infrared photons to vacuum-ultraviolet and soft x-ray high-order harmonics in gaseous, liquid and solid targets is notoriously inefficient. In dense nonlinear media, the limiting factor is strong re-absorption of the generated high-energy photons. Here we overcome this limitation by generating high-order harmonics from a periodic array of thin one-dimensional crystalline silicon ridge waveguides. Adding vacuum gaps between the ridges avoids the high absorption loss of the bulk and results in a ~ 100-fold increase of the extraction depth. As the grating period is varied, each high harmonic shows a different and marked modulation, indicating their waveguiding in the vacuum slots with reduced absorption. Looking ahead, our results enable bright on-chip coherent short-wavelength sources and may extend the usable spectral range of traditional nonlinear crystals to their absorption windows. Potential applications include on-chip chemically-sensitive spectro-nanoscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomistic determination of the surface structure of Cu 2 O(111): experiment and theory

Cuprous oxide (Cu 2 O) is a promising catalyst for several important reactions. However, the atomic structures of defective Cu 2 O surfaces, which critically affect the catalytic properties both thermodynamically and kinetically, are not unambiguously characterized. High-resolution scanning tunneling microscopy (STM), combined with density functional theory (DFT) calculations and STM simulations, has been used to determine the atomic structure of the (111) surface of a Cu 2 O bulk crystal. The single crystal surface, processed by ultrahigh vacuum cleaning and oxygen annealing, shows a (1 × 1) periodicity in the low-energy electron diffraction pattern. The pristine (defect-free) Cu 2 O(111) surface exhibits a lattice of protrusions with hexagonal symmetry under STM, which is attributed to the dangling bonds of the coordinatively unsaturated copper (Cu U ) atoms on the surface. Two types of surface atomic defects are also identified, including the Cu U vacancy and the oxygen-vacancy-induced local surface restructuring. The electronic structure of this surface measured by $dI/dV$ spectroscopy shows an energy band gap of ~1.6–2.1 eV. Consistent with $dI/dV$ measurements, DFT calculations identified surface states within the electronic band gap arising from the Cu ions on the surface. Our results provide a clear picture of the pristine and defective Cu 2 O(111) surface structure in addition to the formation mechanism of the reconstructed surface, paving the way toward studying the site-dependent reactivity of this surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ir/TaN as a bilayer diffusion barrier for advanced Cu interconnects

The properties of an Ir (5 nm)/TaN (5 nm) stacked layer as a copper diffusion barrier on Si have been investigated. Ir/TaN bilayer barriers were prepared at room temperature by magnetron sputtering followed by in situ Cu deposition for diffusion tests. Thermal annealing of the barrier stacks was carried out in vacuum at high temperatures for 1 h. X-ray diffraction patterns, cross sectional transmission electron microscopy images, and energy-dispersive spectrometer line scans on the samples annealed at 600 deg. C revealed no Cu diffusion through the barrier. The results indicate that the Ir/TaN bilayer is an effective diffusion barrier for copper metallization.

36 MATERIALS SCIENCE↗

Accurate and quick calibration method for polarization-modulation spectroscopy using an ac-modulated polarizing undulator

An accurate calibration method in which an ac-modulated polarizing undulator is used for polarization modulation spectroscopy such as circular dichroism (CD) and linear dichroism (LD) has been proposed and successfully applied to vacuum ultraviolet (vuv) CD and LD spectra measured at beamline BL-5B in the electron storage ring, TERAS, at AIST. This calibration method employs an undulator-modulation spectroscopic method with a multireflection polarimeter, and it uses electronic and optical elements identical to those used for the CD and LD measurements. This method regards the polarimeter as a standard sample for the CD and LD measurements in the vuv region in which a standard sample has not yet been established. The calibration factors for the CD and LD spectra are obtained over a wide range of wavelengths, from 120 to 230 nm, at TERAS BL-5B. The calibrated CD and LD spectra measured at TERAS exhibit good agreement with the standard spectra for wavelengths greater than 170 nm; the mean differences between the standard and calibrated CD and LD spectra are approximately 7% and 4%, respectively. This method enables a remarkable reduction in the experimental time, from approximately 1 h to less than 10 min that is sufficient to observe the storage-ring current dependence of the calibration factors. This method can be applied to the calibration of vuv-CD spectra measured using a conventional photoelastic modulator and for performing an accurate analysis of protein secondary structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A detailed study of collisionless explosion of single- and two-ion-species spherical nanoplasmas

The collisionless adiabatic expansion into vacuum of spherical plasma targets (clusters) composed of cold single- or multispecies ions and hot electrons is studied kinetically by numerical solving of the nonrelativistic equations of motion of plasma particles in the self-consistent electrostatic field. The expansion dynamics for the whole range of electron temperatures from much less than to much higher than the cluster Coulomb energy is described for various initial plasma density profiles and cluster structures. The explosion of two ion species heterogeneous (layered) and homogeneously mixed targets is studied in detail for the wide range of light ion concentration and kinematic parameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Depth distribution of silver particulate films deposited in softened polystyrene substrates studied through Rutherford backscattering spectrometry

The depth distribution of silver particulate films deposited on softened polystyrene substrates has been studied through Rutherford backscattering spectrometry (RBS). 150 nm thick silver films were deposited on polystyrene (PS) coated glass substrates held at 455 K and 490 K in a vacuum of 8 x 10{sup -6} Torr. The substrates were irradiated with 8 MeV electrons to a dose of 25 kGy prior to deposition. Ion scattering measurements indicated that the silver particulates are formed at a few tens of nanometers beneath the PS surface for both unirradiated and irradiated substrates. The particulate structure seems to be a two-dimensional array rather than a three-dimensional distribution. The morphology of the particulate structure, the depth of maximum concentration of the particles as well as the width of the distribution seems to depend on the deposition rate and substrate temperature. The electron irradiation of the PS substrate gives rise to the modification of the morphology of the particulate structure due to the induced polymer-metal interaction arising from the free radicals created by the irradiation.

36 MATERIALS SCIENCE↗