Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Estimates of Long Term Surface Soil Moisture in the Midwestern U.S. Derived from Satellite Microwave Observations

Soil moisture is a key component of the water and energy balances of the Earth's surface, and has been identified as a parameter of significant potential for improving the accuracy of large-scale land surface-atmosphere interaction models. However, soil moisture is often somewhat difficult to measure accurately in both space and time, especially at large spatial scales. Soil moisture is highly variable, and while point measurements are typically quite accurate, subsequent areal averaging of these measurements often leads to large errors. Since remotely sensed land surface observations are already a spatially averaged or areally integrated value, they are a logical input parameter to regional or larger scale land process models. A database of long-term soil moisture was compared to satellite microwave observations over test sites in the Midwestern United States. Ground measurements of average volumetric surface soil moisture in the top ten cm were made bimonthly at 19 locations throughout the state of Illinois. Nighttime microwave brightness temperatures were observed at a frequency of 6.6 GHz, by the Scanning Multichannel Microwave Radiometer (SMMR), onboard the Nimbus 7 satellite. The life of the SMMR instrument spanned from Nov. 1978 to Aug. 1987. At 6.6 GHz, the instrument provided a spatial resolution of approximately 150 km, and a temporal frequency over the test area of about 3 nighttime orbits per week. Vegetation radiative transfer characteristics, such as the canopy transmissivity, were estimated from vegetation indices such as the Normalized Difference Vegetation Index (NDVI) and the 37 GHz Microwave Polarization Difference Index (MPDI). Because the time of satellite coverage does not always coincide with the ground measurements of soil moisture, the existing ground data were used to calibrate a water balance for the top IO cm surface layer in order to interpolate daily surface moisture values. Such a climate-based approach is often more appropriate for estimating large-area average soil moisture because meteorological data are generally more spatially representative than isolated point measurements of soil moisture, Passive microwave remote sensing presents the greatest potential for providing regular spatially representative estimates of surface soil moisture at global scales. Real time estimates should improve weather and climate modelling efforts, while the development of historical data sets will provide necessary information for simulation and validation of long-term climate and global change studies.

Owe, M.↗

Safe suspension of specimens or clusters during dynamic testing - A concept

Support system without point supports permits dynamic testing of complex or delicate mechanical units without excessive movement which might cause damage. Motion-sensor pressure-control system regulates inflation of molded rubber bags surrounding test specimen, so that any excessive motion is smothered until test is terminated.

Hoch, G. C.↗

Digital control of high-intensity acoustic testing

Three systems for the control of acoustic testing are compared: a hybrid digital/analog system, a digital vibration system, and the same digital vibration system modified by a software change. The hybrid system was constructed to control the 1/3-octaves from 50 to 1000 Hz. The vibration system was equipped with programs for sine and random vibration tests, shock analysis and synthesis, and signal analysis. For the modified vibration system, the random-vibration control program of the unmodified unit was changed so that acoustic tests could be performed. The performance of the three systems is compared by conducting probability-density and time-history analyses of the proposed test spectrum for the Mariner Jupiter/Saturn 1977 program. The results of the analyses show that the hybrid and modified vibration systems perform almost equally, but the modified vibration system is easier to use and produces better test documentation.

Slusser, R. A.↗

Mechanically Induced g-Jitter from Space Station Rotary Joints

The mission of the International Space Station is to provide a working laboratory in orbit for research in engineering, life sciences, and microgravity. Among the microgravity disciplines that are preparing to utilize this international resource are materials processing, combustion, fluid dynamics, biotechnology, and fundamental physics. The Station promises to enable significant advances in each of these areas by making available a research facility in which gravitational and other accelerations, and their corresponding buoyancy and diffusion effects on various physical processes, are orders of magnitude lower than they are on Earth. In order to fulfill this promise, it is not enough for the Space Station to simply replicate a typical terrestrial scientific laboratory in orbit. Although an orbiting laboratory is free of most of the effects of gravitational acceleration by virtue of its free fall condition, it also produces structural vibration or jitter that can interfere with the processes under study. To ensure the quality of the acceleration environment and enable a successful mission, the Space Station Program has limited potential disturbances in two ways: first, by isolating the most sensitive payloads from the vehicle structure, and second, by quieting major disturbances at their sources. The first area, payload isolation, is implemented inside the pressurized modules at the rack level. Sub-rack level isolators have also been developed. This paper addresses the second area, disturbance source limits, for one of the major sources of mechanical noise on the Space Station: the Solar Alpha Rotary Joints. Due to the potential for large disturbances to the microgravity environment, an initial analytical prediction of rotary joint vibration output was made. Key components were identified and tested to validate the analytical predictions. Based on the component test results, the final vibration output of the joints was verified by a test on each fully assembled flight unit. This paper describes the Space Station microgravity requirements, the rotary joint hardware, and the disturbance producing aspects of joint operation. The test setup, instrumentation, test conditions, and results for the component level and system level measurements are described. An overall forcing function that describes the maximum torque imparted to the Station is created based on the test results, and these disturbances are shown to meet the applicable Space Station microgravity requirements.

Boucher, Robert L.↗

Short xEMU Pressure Garment Thermal Vacuum Test Results

NASA performed a thermal-vacuum test of the Exploration Extravehicular Mobility Unit (xEMU) to demonstrate the performance of the government reference design in a relevant space-like environment. One of the spacesuit test articles was configurated as a Short-xEMU (SxEMU). This unmanned configuration provided an excellent test to evaluate the Exploration Portable Life Support System (xPLSS), however it posed some challenges with the Exploration Pressure Garment (xPGS) components involved due to the lack of a human wearing a Liquid Cooling and Ventilation Garment (LCVG), which significantly contributes to the thermal performance of the suit. This paper provides an overview of the pressure garment components that made up this portion of the test article, the test configuration, test results, and lessons learned from this very unique spacesuit test.

xemu↗

Towards an Era of Low-Temperature Integral Critical Experiments: Surrogate Testing of Low-Temperature TEX Configurations

United States and IAEA regulations for the transportation of radioactive materials require that fissile materials must be subcritical under expected ambient temperatures ranging from -40°C to 38°C. While historical experiments have been conducted at room and elevated temperatures, no criticality integral benchmarks exist for temperatures below room temperature. The Low-Temperature Thermal Epithermal eXperiments (LT-TEX) aim to provide benchmark evaluations down to -40°C. The LT-TEX design incorporates stacked HEU plates interspersed with varying thicknesses of polyethylene disks to provide varying levels of moderation, with five configurations at 20°C having already been benchmarked. A novel vacuum/cryogenic chamber was fabricated to contain the LT-TEX configurations in a thermally isolated environment and cool it to -40°C. Prior to testing with fissile materials, testing with surrogate fuel plates was performed to characterize the thermal properties of the system, ensure no condensation forms on the stack, and to test that the uranium plates would not warp, or fracture during the thermal cycling. Surrogate testing has characterized the cryogenic chamber and verified its viability to perform the benchmark experiments, allowing for the next steps in the LT-TEX experimental campaign. The results of the surrogate testing are discussed and compared to heat transfer calculations performed as part of the experiment design process, to establish confidence in the thermal behavior of the system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detailed Test Plan Redundant Sensor Strapdown IMU Evaluation Program

The test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The subjects discussed are: (1) test philosophy and limitations, (2) test sequence, (3) equipment specifications, (4) general operating procedures, (5) calibration procedures, (6) alignment test phase, and (7) navigation test phase. The data and analysis requirements are analyzed.

Hartwell, T.↗

Transistor step stress program for JANTX2N4150

Reliability analysis of the transistor JANTX2N4150 manufactured by General Semiconductor and Transitron is reported. The discrete devices were subjected to power and temperature step stress tests and then to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented.

Source record↗

Diode step stress program for JANTX1N645-1

The diode JANTX1N645-1 manufactured by Semtech and Micro Semiconductor was subjected to power/temperature step stress in order to assess its reliability. All test samples were subjected to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented in tabular form.

Source record↗

Vibration-Isolation Bench for Testing in Vacuum

Precise optical systems tested without contamination. Vibration isolator is one of three such units supporting cast-iron table. Table used to test optical systems in vacuum. Isolator made from commercially available components. Scaled-down version finds wider application in electron optics or electron-beam lithography.

Dankowski, J. C.↗

Icing research tunnel test of a model helicopter rotor

An experimental program has been conducted in the NASA Lewis Research Center Icing Research Tunnel (IRT) in which an OH-58 tail rotor assembly was operated in a horizontal plane to simulate the action of a typical main rotor. Ice was accreted on the blades in a variety of rotor and tunnel operating conditions and documentation of the resulting shapes was performed. Rotor torque and vibration are presented as functions of time for several representative test runs, and the effects of various parametric variations on the blade ice shapes are shown. This OH-58 test was the first of its kind in the United States and will encourage additional model rotor icing tunnel testing. Although not a scaled representative of any actual full-scale main rotor system, this rig has produced torque and vibration data which will be useful in assessing the quality of existing rotor icing analyses.

Miller, Thomas L.↗

Icing Research Tunnel test of a model helicopter rotor

An experimental program has been conducted in the NASA Lewis Research Center Icing Research Tunnel (IRT) in which an OH-58 tail rotor assembly was operated in a horizontal plane to simulate the action of a typical main rotor. Ice was accreted on the blades in a variety of rotor and tunnel operating conditions and documentation of the resulting shapes was performed. Rotor torque and vibration are presented as functions of time for several representative test runs, and the effects of various parametric variations on the blade ice shapes are shown. This OH-58 test was the first of its kind in the United States and will encourage additional model rotor icing tunnel testing. Although not a scaled representative of any actual full-scale main rotor system, this rig has produced torque and vibration data which will be useful in assessing the quality of existing rotor icing analyses.

Miller, Thomas L.↗

Quantitative computer simulations of extraterrestrial processing operations

The automation of a small, solid propellant mixer was studied. Temperature control is under investigation. A numerical simulation of the system is under development and will be tested using different control options. Control system hardware is currently being put into place. The construction of mathematical models and simulation techniques for understanding various engineering processes is also studied. Computer graphics packages were utilized for better visualization of the simulation results. The mechanical mixing of propellants is examined. Simulation of the mixing process is being done to study how one can control for chaotic behavior to meet specified mixing requirements. An experimental mixing chamber is also being built. It will allow visual tracking of particles under mixing. The experimental unit will be used to test ideas from chaos theory, as well as to verify simulation results. This project has applications to extraterrestrial propellant quality and reliability.

Vincent, T. L.↗

Beyond Gravity Single Launch Payload Accommodations Shock Testing

The Vulcan Centaur launch vehicle is purpose-built to meet all the U.S. government’s National Security Space Launch (NSSL) needs. A shock test for the Centaur V’s payload accommodations (PLA), single launch (SL) configuration was successfully conducted at NASA’s Marshall Space Flight Center (MSFC) in Huntsville, Alabama, in May 2021. This test was a joint effort between MSFC, Beyond Gravity and United Launch Alliance. The primary purpose of the shock test was to characterize the shock environment induced by the separation event on components attached to the PLA and its interfaces. Additional test requirements included: (1) verifying the payload fairing (PLF) did not contact the flight hardware during the mechanical separation of the PLF horizontal separation system (HSS) and (2) evaluating the performance of the HSS spring packages during jettison. The data acquired during the PLF SL shock test will be used to validate the shock predictions from pre-test analysis of the launch vehicle and the PLF separation analysis. This paper provides an overview of the PLA SL shock test planning and execution as well as the required catch system, instrumentation and results.

separation↗

Beyond Gravity Single Launch Payload Accommodations Shock Testing

The Vulcan Centaur launch vehicle is purpose-built to meet all the U.S. government’s National Security Space Launch (NSSL) needs. A shock test for the Centaur V’s payload accommodations (PLA), single launch (SL) configuration was successfully conducted at NASA’s Marshall Space Flight Center (MSFC) in Huntsville, Alabama, in May 2021. This test was a joint effort between MSFC, Beyond Gravity and United Launch Alliance. The primary purpose of the shock test was to characterize the shock environment induced by the separation event on components attached to the PLA and its interfaces. Additional test requirements included: (1) verifying the payload fairing (PLF) did not contact the flight hardware during the mechanical separation of the PLF horizontal separation system (HSS) and (2) evaluating the performance of the HSS spring packages during jettison. The data acquired during the PLF SL shock test will be used to validate the shock predictions from pre-test analysis of the launch vehicle and the PLF separation analysis. This paper provides an overview of the PLA SL shock test planning and execution as well as the required catch system, instrumentation and results.

separation↗

Beyond Gravity Single Launch Payload Accommodations Shock Testing

The Vulcan Centaur launch vehicle is purpose-built to meet all the U.S. government’s National Security Space Launch (NSSL) needs. A shock test for the Centaur V’s payload accommodations (PLA), single launch (SL) configuration was successfully conducted at NASA’s Marshall Space Flight Center (MSFC) in Huntsville, Alabama, in May 2021. This test was a joint effort between MSFC, Beyond Gravity and United Launch Alliance. The primary purpose of the shock test was to characterize the shock environment induced by the separation event on components attached to the PLA and its interfaces. Additional test requirements included: (1) verifying the payload fairing (PLF) did not contact the flight hardware during the mechanical separation of the PLF horizontal separation system (HSS) and (2) evaluating the performance of the HSS spring packages during jettison. The data acquired during the PLF SL shock test will be used to validate the shock predictions from pre-test analysis of the launch vehicle and the PLF separation analysis. This paper provides an overview of the PLA SL shock test planning and execution as well as the required catch system, instrumentation and results.

separation↗

Turbine Powered Simulator Calibration and Testing for Hybrid Wing Body Powered Airframe Integration

Propulsion airframe integration testing on a 5.75% scale hybrid wing body model us- ing turbine powered simulators was completed at the National Full-Scale Aerodynamics Complex 40- by 80-foot test section. Four rear control surface con gurations including a no control surface de ection con guration were tested with the turbine powered simulator units to investigate how the jet exhaust in uenced the control surface performance as re- lated to the resultant forces and moments on the model. Compared to ow-through nacelle testing on the same hybrid wing body model, the control surface e ectiveness was found to increase with the turbine powered simulator units operating. This was true for pitching moment, lift, and drag although pitching moment was the parameter of greatest interest for this project. With the turbine powered simulator units operating, the model pitching moment was seen to increase when compared to the ow-through nacelle con guration indicating that the center elevon and vertical tail control authority increased with the jet exhaust from the turbine powered simulator units.

Shea, Patrick R.↗

Pendulum Motion in Main Parachute Clusters

The coupled dynamics of a cluster of parachutes to a payload are notoriously difficult to predict. Often the payload is designed to be insensitive to the range of attitude and rates that might occur, but spacecraft generally do not have the mass and volume budgeted for this robust of a design. The National Aeronautics and Space Administration (NASA) Orion Capsule Parachute Assembly System (CPAS) implements a cluster of three mains for landing. During testing of the Engineering Development Unit (EDU) design, it was discovered that with a cluster of two mains (a fault tolerance required for human rating) the capsule coupled to the parachute cluster could get into a limit cycle pendulum motion which would exceed the spacecraft landing capability. This pendulum phenomenon could not be predicted with the existing models and simulations. A three phased effort has been undertaken to understand the consequence of the pendulum motion observed, and explore potential design changes that would mitigate this phenomenon. This paper will review the early analysis that was performed of the pendulum motion observed during EDU testing, summarize the analysis ongoing to understand the root cause of the pendulum phenomenon, and discuss the modeling and testing that is being pursued to identify design changes that would mitigate the risk.

Ray, Eric S.↗