Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

System efficiency and power assessment of the all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) use low-temperature (T < 100 °C) heat to provide stationary energy and power with higher power densities and efficiency relative to other waste heat devices. TRABs are an active area of research in waste heat devices, but currently there is little consensus on what aspect of the system is limiting TRAB performance and what maximum efficiencies are possible. Experiments and numerical models were used here to examine the sensitivity of the battery and distillation column in a TRAB system to key operating variables, thereby establishing practical limits and identifying focus areas for improving performance. Battery power was eight times more sensitive to ohmic losses than kinetic and mass transfer losses, regardless of the operating temperature, and the peak power density was simulated to be 18.8 mW cm –2 at 75 °C. Theoretical energy efficiency limits were defined for a series of ammonia concentrations and operating pressures, ranging from 5 – 12%, which is 2–3 times higher than previous experimental estimations. Atmospheric pressure column operation used a larger amount of waste heat compared to sub-atmospheric pressure. It is estimated that the volume of the battery would take up 9.2m 3 for every 1% of the power output of a natural gas turbine, but with realistic improvements to cell conductivity, the size would reduce to 2.5 m 3 . Finally, the results presented in this work will help streamline future development by focusing on minimizing ohmic losses and provide specific data for full system evaluation of future TRABs.

25 ENERGY STORAGE↗

Calibrated simulation analysis for integration of evaporative cooling and radiant cooling system for different Indian climatic zones

Radiant cooling system (RCS) has proven to be an energy efficient system for meeting a building's cooling requirements. RCS is energy efficient and provides better thermal comfort compared to conventional all-air heating ventilation air conditioning (HVAC) system. To further improve the efficiency of RCS, a parallel evaporative cooling system (cooling tower) is coupled with RCS and analyzed for different climatic condition using calibrated model. A statistical analysis of weather files (based on wet bulb temperature), was used to identify the availability of useful water for cooling tower integration with RCS. A comprehensive simulation feasibility study of the application of cooling tower in RCS was performed for different cities to cover every climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of different climatic zones, except warm-humid, is suitable for the integration of cooling tower with RCS. An experimental setup was designed and developed for integration of parallel chiller and cooling tower with panel-based RCS for cooling and a dedicated outdoor air system (DOAS) for dehumidification and ventilation. Experiments were conducted for chiller and cooling tower operated RCS in Composite climate of Jaipur, Rajasthan, India. Building Energy Models (BEM) were developed for both the chiller-operated RCS and cooling tower-operated RCS in EnergyPlus and calibrated with the measured data. Using the calibrated models, performance of the system was analyzed for different climatic zones of India. A chiller-operated RCS was considered as a baseline to compare the annual energy saving potential and monthly performance of the cooling tower integrated RCS. Here, in the cooling tower–operated RCS, a total annual savings of 7% in hot and dry climates, 11% in composite climates and 20% in temperate climates was achieved compared to the chiller-operated RCS.

54 ENVIRONMENTAL SCIENCES↗

Redox-mediated activation of latent transforming growth factor-beta 1

Transforming growth factor beta 1 (TGF beta) is a multifunctional cytokine that orchestrates response to injury via ubiquitous cell surface receptors. The biological activity of TGF beta is restrained by its secretion as a latent complex (LTGF beta) such that activation determines the extent of TGF beta activity during physiological and pathological events. TGF beta action has been implicated in a variety of reactive oxygen-mediated tissue processes, particularly inflammation, and in pathologies such as reperfusion injury, rheumatoid arthritis, and atherosclerosis. It was recently shown to be rapidly activated after in vivo radiation exposure, which also generates reactive oxygen species (ROS). In the present studies, the potential for redox-mediated LTGF beta activation was investigated using a cell-free system in which ROS were generated in solution by ionizing radiation or metal ion-catalyzed ascorbate reaction. Irradiation (100 Gray) of recombinant human LTGF beta in solution induced 26% activation compared with that elicited by standard thermal activation. Metal-catalyzed ascorbate oxidation elicited extremely efficient recombinant LTGF beta activation that matched or exceeded thermal activation. The efficiency of ascorbate activation depended on ascorbate concentrations and the presence of transition metal ions. We postulate that oxidation of specific amino acids in the latency-conferring peptide leads to a conformation change in the latent complex that allows release of TGF beta. Oxidative activation offers a novel route for the involvement of TGF beta in tissue processes in which ROS are implicated and endows LTGF beta with the ability to act as a sensor of oxidative stress and, by releasing TGF beta, to function as a signal for orchestrating the response of multiple cell types. LTGF beta redox sensitivity is presumably directed toward recovery of homeostasis; however, oxidation may also be a mechanism of LTGF beta activation that can be deleterious during disease mechanisms involving chronic ROS production.

Non-NASA Center↗

Climate Impacts on U.S. Electric Sector Evolution and Water Use Under Varying Market Futures: Are Some Energy Technologies and Regions More Affected by Climate Than Others?

Climate impacts on air temperatures and water availability have the potential to alter future electricity sector investment decisions as well as the reliability and performance of the U.S. power system. Different electricity sector configurations are more or less vulnerable to climate-induced changes. For example, once-through cooled thermal facilities are very efficient under cooler and wetter conditions but can be more vulnerable under warmer and drier conditions. Non-thermal renewable technologies are essentially 'drought-proof' but have other reliability challenges. Prior efforts have explored the impacts of climate change on electric sector for a limited set of climate and electricity scenarios. Here, we provide a comprehensive suite of scenarios that evaluate how different electricity sector market futures in the U.S. could be affected by a range of climate and water resource conditions. We use four representative concentration pathway (RCP) scenarios under five global circulation models (GCM) as climate drivers to a Water Balance Model (WBM), for twenty unique future climate-water conditions modeled through 2050. The electric sector impacts of these climate-water futures are then evaluated by the Regional Energy Deployment Systems (ReEDS) electricity capacity expansion model. To explore a breadth of possible electricity market futures, four electricity sector scenarios are considered to represent different carbon emission and water usage conditions: (1) business-as-usual, (2) CO2 cap, (3) CO2 cap with high renewable energy costs and extended nuclear lifetimes, and (4) continued coal reliance that maintains the existing coal fleet through 2050. Thus, we examine 84 possible futures in total when including a static climate representation of each market scenario. Results indicate that U.S. electric sector responds to climate change by constructing a combination of gas-fired and low-carbon generating sources, and the balance between technologies are determined by fuel prices, technology costs and policy. The cost for power sector to respond to climate change are generally proportional to the costs of electricity system components, while the relative sensitivity and vulnerability to climate pressures will vary across different generating technologies and different regions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal Properties of Polymer Hole-Transport Layers Influence the Efficiency Roll-off and Stability of Perovskite Light-Emitting Diodes

While the performance of metal halide perovskite light-emitting diodes (PeLEDs) has rapidly improved in recent years, their stability remains a bottleneck to commercial realization. Here, we show that the thermal stability of polymer hole-transport layers (HTLs) used in PeLEDs represents an important factor influencing the external quantum efficiency (EQE) roll-off and device lifetime. We demonstrate a reduced EQE roll-off, a higher breakdown current density of approximately 6 A cm -2 , a maximum radiance of 760 W sr -1 m -2 , and a longer device lifetime for PeLEDs using polymer HTLs with high glass-transition temperatures. Furthermore, for devices driven by nanosecond electrical pulses, a record high radiance of 1.23 MW sr -1 m -2 and an EQE of approximately 1.92% at 14.6 kA cm -2 are achieved. Thermally stable polymer HTLs enable stable operation of PeLEDs that can sustain more than 11.7 million electrical pulses at 1 kA cm -2 before device failure.

14 SOLAR ENERGY↗

Pumped Thermal Energy Storage Using Low-Cost Particles and a Fluid Bed Heat Exchanger for Maximum Power Efficiency

Robust, efficient, cost-effective long-duration electricity storage (LDES) solutions can enhance grid resiliency, support existing transmission and distribution infrastructure, and enable a greater share of low-cost, variable alternative energy sources to penetrate the market. To meet this need, the project team at the National Renewable Energy Laboratory developed a transformative LDES system based on pumped thermal energy storage (TES) using low-cost particles and a fluid bed heat exchanger for maximum power efficiency (PUMP). The PUMP system is composed of high-temperature, low-cost particle TES coupled with an advanced pressurized fluid bed heat exchanger (PFB HX) that supports a high-efficiency pumped thermal energy storage (PTES) system integrated with concentrating solar thermal power (CSP). The PUMP project developed and de-risked a PFB HX and particle CSP system intended to be integrated with reversible turbomachinery and a modeling tool to assess PTES cost and performance.

14 SOLAR ENERGY↗

Enhancing Lignin Dispersion and Bioconversion by Eliminating Thermal Sterilization

Thermal sterilization is widely applied in fermentation to ensure a pure culture. In this study, a facile and energy-efficient strategy by eliminating thermal sterilization (ETS) was unveiled for upgrading lignin bioconversion. Through alkaline solubilization and neutralization, lignin dispersion in aqueous fermentation media was significantly enhanced by ETS. Small-angle X-ray scattering and dynamic light scattering analyses indicated that the lignin colloid size was dramatically reduced. Compared to 20.5 wt % lignin precipitation during the conventional thermal sterilization, precipitated lignin was not observed within the ETS medium. 31P NMR characterization demonstrated an 11.7% increase of phenolic OH in ETS lignin. Ionization of phenolic OH presented more negatively charged groups, strengthening electrostatic repulsion, resulting in smaller colloidal particles. Interestingly, the pure culture of Rhodococcus opacus PD630 was achieved within the ETS medium due to the lack of lignin degradation ability with most natural microbes. R. opacus PD630 cell amount, lignin degradation, and lipid production by ETS increased by 330, 16.6, and 20.7%, respectively. Overall, an energy-efficient ETS strategy that promoted lignin dispersion and bioconversion significantly is reported in this study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Material-based figure of merit for caloric materials

Efficient use of reversible thermal effects in magnetocaloric, electrocaloric, and elastocaloric materials is a promising avenue that can lead to a substantially increased efficiency of refrigeration and heat pumping devices, most importantly those used in household and commercial cooling applications near ambient temperature. A proliferation in caloric materials research has resulted in a wide array of materials where only the isothermal change in entropy in response to a handful of different field strengths over a limited range of temperatures has been evaluated and reported. Given the abundance of such data, there is a clear need for a simple and reliable figure of merit enabling fast screening and down-selection to justify further detailed characterization of those materials systems that hold the greatest promise. Based on the analysis of several well-known materials that exhibit vastly different magnetocaloric effects, the Temperature averaged Entropy Change (TEC) is introduced as a suitable early indicator of the material’s utility for magnetocaloric cooling applications, and its adoption by the caloric community is recommended.

36 MATERIALS SCIENCE↗

Enabling fast charging – Battery thermal considerations

Battery thermal barriers are reviewed with regards to extreme fast charging. Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. If the battery thermal management system is not designed correctly, the temperature of the cells could reach abuse temperatures and potentially send the cells into thermal runaway. Furthermore, the cell and battery interconnect design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and what type of battery thermal management solutions are available in today’s market. Here, thermal management is not a limiting condition with regard to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

25 ENERGY STORAGE↗

Thermal Implications for Extreme Fast Charge

Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. If the battery thermal management system is not designed correctly, the temperature of the cells could reach abuse temperatures and potentially send the cells into thermal runaway. Furthermore, the cell and battery interconnect design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and what type of battery thermal management solutions are available in today's market. Thermal management is not a limiting condition with regard to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental Study of Counterflow Cooling Using a Test Loop to Simulate the Thermal Characteristics of a HTS Cable System

The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.

Demko, Jonathan A↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Electric Motor Thermal Management R&D

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

33 ADVANCED PROPULSION SYSTEMS↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

30 DIRECT ENERGY CONVERSION↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R and D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

25 ENERGY STORAGE↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

47 OTHER INSTRUMENTATION↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗