Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

First Protein Crystallization Experiments on The International Space Station: Sweet Success in Space With Thaumatin

We determined the room temperature 1.2 A structure of thaumatin using a crystal grown in the first protein crystallization experiment conducted aboard the International Space Station (ISS). The crystals were grown in the Enhanced Gaseous Nitrogen Dewar (EGN) developed by Alexander McPherson and co-workers. EGN transports frozen solutions contained in tygon tubing in a liquid nitrogen Dewar to ISS where the tubes then thaw. Batch, free interface diffusion (FID), or vapor diffusion crystallization occurs after thawing. EGN was flown to the ISS on STS-106 on September 8, 2000. This was a "risk mitigation" flight that tested EGN performance and the process of conducting experiments on ISS. We focused on how to map a hanging drop crystallization recipe to the EGN FID method. Thaumatin was chosen as the test system. Three series of crystallization recipes were set-up. Each series tested different volume ratios of protein-rich solution to precipitant-rich solution. The series differed from each other by fixing either the protein concentration or the amount of protein in the solutions. Upon return of the samples to Earth on October 24 by STS-92, bubbles that spanned the diameter of the tubing were observed in all tubes. Such bubbles interrupt liquid-liquid diffusion and force vapor diffusion equilibration to occur instead. Nonetheless, crystals grew in 9 of 30 tubes. Many large crystals were grown, the largest being 2.0 x 1.1 x 1.0 cubic mm. The largest crystal was used to collect data at room temperature on beamline 7-1 of the Stanford Synchrotron Radiation Source to a maximum resolution of 1.2 A. The structure was refined anisotropically using SHELX with a data to parameter ratio of 4.5 to give an R(sub factor) of 15.8% (R(sub free) = 18.2%) for ail reflections without generated hydrogens. This refinement is proceeding. Comparisons of this 1.2 A microgravity structure to previous reports of the thaumatin structure at 1.75 A and to ground control crystals will be presented.

Kundrot, Craig E.↗

Wavefront Calibration Testing of the James Webb Space Telescope Primary Mirror Center of Curvature Optical Assembly

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) consists of a 6.6 meter clear aperture, all-reflective, three-mirror anastigmat!. The 18-segment primary mirror (PM) presents unique and challenging assembly, integration, alignment and testing requirements. A full aperture center of curvature optical test is performed in cryogenic vacuum conditions at the integrated observatory level to verify PM performance requirements. Two wavefront calibration tests are utilized to verify the low and Mid/High spatial frequency performance ofthe test system. In this paper the methods and results of the wavefront calibration tests are presented.

Olczak, Gene↗

Study on 3D Internal Magnetic Field Distribution and Dynamic Mechanics of a Giant Magnetostrictive Actuator

The three-dimensional (3D) coupled magneto-elastic dynamic model of a giant magnetostrictive actuator (GMA) was built based on Maxwell’s equations, elasticity, and vibration theories. The general analytical expressions for the 3D internal magnetic field distribution of GMA were derived, and the corresponding analytical solutions were obtained. This analytical model is able to predict the internal magnetic field distribution and the output displacement of GMA system with different physical parameters under external excitations. The dynamic behaviors, such as the amplitude vs. frequency responses and the time domain waveforms of the GMA, were also studied. Analytical solutions showed that the internal magnetic field has a prominent end effect along the axial direction of a giant magnetostrictive material (GMM) rod, whereas a minimal skin effect along its radial direction, which are matched very well with the FEM results. The amplitude-frequency relationship exhibited prominent resonance and anti-resonance characteristic, which is a typical hysteresis feature of the GMA system. In order to testify the validity of the model prediction, a GMA testing system was also established. Excellent agreement was found between the experiment measurements and model predictions in the range of our research (frequency is lower than 300 Hz). The analytical results of the present study have potential applications in the fields of active vibration control and other precision machining of the GMA system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Response of Large Wind Power Plant Affected by Diverse Conditions at Individual Turbines

Diverse operating conditions at individual wind turbine generators (WTG) within wind power plants (WPPs) can affect the WPP dynamic response to system faults. For example, individual WTGs can experience diverse terminal voltage and power output caused by different wind direction and speed, affecting the response of protection and control limiters. In this paper, we present a study to investigate the dynamic response of a detailed WPP model under diverse power outputs of its individual WTGs. Wake effect is considered as the reason for diverse power outputs. The diverse WTG power output is evaluated in a test system where a large 168-machine test WPP is connected to the IEEE-39-bus system. The power output from each WTG is derived from a wake effect model that uses realistic statistical data for incoming wind speed and direction. The results show that diverse WTG output due to wake effect can affect the WPP dynamic response activating specialized control in some turbines. In addition, transient stability is affected by exhibiting uncertainty in critical clearing time calculation.

Power system dynamic performance, power system sta↗

Pulsed plasma propulsion system for North-South stationkeeping

A completely integrated pulsed plasma propulsion system for North-South stationkeeping has been developed. System testing on a thrust balance has provided following new results: (1) A simple, helically coiled, spring-fed propellant subsystem for 38,284 lb-s (166,000 N-S) total impulse is feasible; (2) The propulsive performance level is compatible with North-South stationkeeping requirements; (3) Power conditioning is as simple as that of the space flight proven microthruster system; (4) Vacuum compatible, high energy density capacitors (40 joules/lb) capacitors have been developed and tested as part of the system; (5) 10,000 lb-sec of total impulse has been generated. Future improvements will include reducing electrode erosion, improving the structural rigidity of the assembly and continuously operating the system until 37,000 lb-sec of total impulse have been generated.

Guman, W. J.↗

NEXT Single String Integration Tests in Support of the Double Asteroid Redirection Test Mission

A system integration test has been performed utilizing a prototype model NEXT ion thruster, an engineering model power processing unit, and a laboratory model command and data handling system. The objectives of the test were to: a) verify that the integrated system meets performance requirements, b) demonstrate that the integrated system is functional across the anticipated thermal, power processor, and Xe propellant ranges for the DART mission, and to c) evaluate fault detection and operation of the command and data handling system. Measurements made during this test included: thruster performance, PPU input voltages, PPU electrical and thermal telemetry, software states, and fault flags. Additionally, a far-field electrostatic probe diagnostic was used to infer relative changes in the thrust vector across the various propellant flow splits. This manuscript presents the results of these tests, which include integrated ion propulsion system demonstrations of performance, details on the execution of DART flight algorithms, and software fault handling.

Thomas, Robert E.↗

NEXT Single String Integration Tests in Support of the Double Asteroid Redirection Test Mission

A system integration test has been performed utilizing a prototype model NEXT ion thruster, an engineering model power processing unit, and a laboratory model command and data handling system. The objectives of the test were to: a) verify that the integrated system meets performance requirements, b) demonstrate that the integrated system is functional across the anticipated thermal, power processor, and Xe propellant ranges for the DART mission, and to c) evaluate fault detection and operation of the command and data handling system. Measurements made during this test included: thruster performance, PPU input voltages, PPU electrical and thermal telemetry, software states, and fault flags. Additionally, a far-field electrostatic probe diagnostic was used to infer relative changes in the thrust vector across the various propellant flow splits. This manuscript presents the results of these tests, which include integrated ion propulsion system demonstrations of performance, details on the execution of DART flight algorithms, and software fault handling.

Thomas, Robert↗

Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages over many other bulk electrical tests. Two commercial FDR systems plus a laboratory vector network analyzer are used to test an array of aged and un-aged cables under identical conditions. Several conclusions are set forth, and a number of knowledge gaps are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Runway Incursion Prevention System: Demonstration and Testing at the Dallas/Fort Worth International Airport

A Runway Incursion Prevention System (RIPS) was tested at the Dallas-Ft. Worth International Airport (DFW) in October 2000. The system integrated airborne and ground components to provide both pilots and controllers with enhanced situational awareness, supplemental guidance cues, a real-time display of traffic information, and warning of runway incursions in order to prevent runway incidents while also improving operational capability. A series of test runs was conducted using NASA s Boeing 757 research aircraft and a test van equipped to emulate an incurring aircraft. The system was also demonstrated to over 100 visitors from the aviation community. This paper gives an overview of the RIPS, DFW flight test activities, and quantitative and qualitative results of the testing.

Jones, Denise R.↗

Fault-tolerance experiments with the JPL STAR computer.

Results of fault-tolerance experiments performed using an experimental computer with dynamic (standby) redundancy, including replaceable subsystems and a 'program rollback' provision to eliminate transient-caused errors. After a brief review of the specification of fault-tolerance with respect to transient faults, including a description of the method of injection of transient faults in software and system tests, fault-tolerance experiments carried out with this computer with regard to the determination of fault classes, software verification, system verification, and recovery stability are summarized. A test and repair processor is described which constitutes a special monitor unit of the computer and is used to obtain information for fault detection in the other subsystems of the computer and to ensure that proper recovery occurs when a fault is detected.

Avizienis, A.↗

OAO-3 end of mission tests report

Twelve engineering type tests were performed on several subsystems and experiment(s) of the OAO 3 spacecraft near its end of mission. The systems tested include: Princeton experiment package (PEP), fine error system guidance, inertial reference unit, star trackers, heat pipes, thermal control coatings, command and data handling, solar array; batteries, and onboard processor/power boost regulator. Generally, the systems performed well for the 8 1/2 years life of OAO 3, although some degradation was noted in the sensitivity of PEP and in the absorptivity of the skin coatings. Battery life was prolonged during the life of the mission in large part by carefully monitoring the charge-discharge cycle with careful attention not to overcharge.

Kalil, F.↗

Water electrolysis system refurbishment and testing

The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.

Greenough, B. M.↗

Thermal system and environmental testing of the Mars Helicopter

The Mars Helicopter will be a technology demonstration conducted during the Mars 2020 mission. The primary mission objective is to achieve several 90-second flights demonstrating the feasibility of heavier than air flight on Mars and capture visible light images via forward and nadir mounted cameras. These flights could possibly provide reconnaissance data for sampling site selection for other Mars surface missions. A solar array and batteries for flight operations, imaging, communications, and survival heating power the Helicopter. The thermal design is driven by minimizing survival heater energy while maintaining compliance with allowable flight temperatures in a variable thermal environment. Due to the small size of the Helicopter and its complex geometries, along with the fact that it operates with very low power and small margins in the extreme Mars environment, additional care had to be paid while planning thermal tests and designing the thermal system. The first section of the paper describes the evolution of the thermal system of the Mars Helicopter. After the first thermal vacuum test of the engineering model, the thermal team has conducted a partial effect analysis on the thermal design components that had a major impact on the system performance. Several design choices derived by analysis and test have been made to meet the energy allocation and the temperature requirements. These changes included increased gas gaps to reduce gas conduction, low emissivity coatings for internal components, blanket implementation, optimization of wire routing and fine-tuning of surface operations to optimize waste heat recovery. The second part of the paper describes the flight model thermal vacuum test and the subsequent thermal model correlation necessary to confirm the fidelity of the analysis results.

Pauken, Michael↗

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Escort: A data acquisition and display system to support research testing

Primarily designed to acquire data at steady state test conditions, the system can also monitor slow transients such as those generated in moving to a new test condition. The system configuration makes use of a microcomputer at the test site which acts as a communications multiplexer between the measurement and display devices and a centrally located minicomputer. A variety of measurement and display devices are supported using a modular approach. This allows each system to be configured with the proper combination of devices to meet the specific test requirements, while still leaving the option to add special interfaces when needed. Centralization of the minicomputer improves utilization through sharing. The creation of a pool of minis to provide data acquisition and display services to a variable number of running tests also offers other important advantages.

Miller, R. L.↗

Regenerative Fuel Cell Test Rig at Glenn Research Center

The regenerative fuel cell development effort at Glenn Research Center (GRC) involves the integration of a dedicated fuel cell and electrolyzer into an energy storage system test rig. The test rig consists of a fuel cell stack, an electrolysis stack, cooling pumps, a water transfer pump, gas recirculation pumps, phase separators, storage tanks for oxygen (O2) and hydrogen (H2), heat exchangers, isolation valves, pressure regulators, interconnecting tubing, nitrogen purge provisions, and instrumentation for control and monitoring purposes. The regenerative fuel cell (RFC) thus formed is a completely closed system which is capable of autonomous cyclic operation. The test rig provides direct current (DC) load and DC power supply to simulate power consumption and solar power input. In addition, chillers are used as the heat sink to dissipate the waste heat from the electrochemical stack operation. Various vents and nitrogen (N2) sources are included in case inert purging is necessary to safe the RFC test rig.

Chang, Bei-Jiann↗

System reliability analysis through corona testing

In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.

Lalli, V. R.↗

Experimental design, operation, and results of a 4 kW high temperature steam electrolysis experiment

High temperature steam electrolysis (HTSE) is a promising technology for large-scale hydrogen production. However, research on HTSE performance above the kW level is limited. This paper presents the results of 4 kW HTSE long-term test completed in a multi-kW test facility recently developed at the Idaho National Laboratory (INL). The 4 kW HTSE unit included two solid oxide electrolysis stacks operating in parallel, each of which included 40 electrode-supported planar cells. A current density of 0.41 A/cm2 was used for the long-term operation, resulting in a hydrogen production rate about 25 slpm. A demonstration of 920 hours stable operation was achieved. The paper also includes detailed descriptions of the piping layout, steam generation and delivery system, test fixture, heat recuperation system, hot zone, instrumentation, and operating conditions. As a result, this successful demonstration of multi-kW scale HTSE unit will help to advance the technology toward near-term commercialization.

08 HYDROGEN↗