Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Effects of space environment on space-based radar phased-array antenna: Status and preliminary observations

The overall objective is to evaluate the effect of the space environment on Kapton films considered for the Grumman space based radar (SBR) phased-array antenna. The most striking result is the overall good condition of the Kapton antenna planes and Kapton tensile specimens. This is largely attributable to the orientation of the Kapton (parallel and flush on the space end) and the stability of the LDEF in orbit. Results on elongation and mechanical properties of the plain and fiberglass reinforced Kapton will be described. Stress-dependent permanent deformation and some reductions in strain to failure were observed. Physical property testing of the materials is in progress. Electronic data acquisition and memory systems appeared to operate correctly, but functional tests were not yet performed. An evaluation of the high voltage-plasma interaction data is underway. Some minor systems anomalies (e.g., fastener sheared during removal, strong odor inside electronics container) were noted. Other observations such as radiation, contamination, impacts, and orientation features of atomic oxygen erosion are reported.

Whiteside, J. B.↗

Non-aqueous Electrolytes for High Voltage Lithium Ion Batteries

Lithium ion batteries to power plug-in hybrid electrical vehicles (PHEV) must store more energy per unit volume and weight, and be capable of undergoing many thousands of charge/discharge cycles. The existing battery technologies have serious limitations such as high cost, limited capacity and lifetime. One way to significantly increase the energy storage capacity of lithium ion batteries is to increase cell voltage by using high voltage cathode materials. For example, the LiNi1/3Mn1/3Co1/3O2 (NMC) system has a capacity of ca. 170 mAh/g when charging to 4.3 V vs. Li+/Li. Increasing the voltage results in a significant increase in capacity with values to 200 mAh/g at 4.5 V and approaching 250 mAh/g at even higher potentials. However, most of the current electrolytes are not stable at such high voltages and lead to fast fade in battery capacity. Therefore, electrolytes capable of enduring high voltages are required for the next generation of lithium ion batteries. It is well known that electrolyte components - salt, solvents and additives, are critical to the success of lithium ion batteries in high energy and power applications. Such electrolyte components and their compositions have large effects on the properties and performances of the final electrolytes and batteries containing them. In this paper, the electrochemical properties and performances of non-aqueous electrolytes containing the state-of-the-art solvents and lithium salts will be investigated. The combination of a high voltage cathode and the high voltage stable electrolyte will be evaluated and presented.

25 ENERGY STORAGE↗

Electrical safety requirements: Implications for the module designer

Commercial photovoltaic array installations, which include residential and intermediate applications, are subject to building and electrical codes and to product safety standards. The National Electrical Code (NEC) Article 690, titled Solar Photovoltaic Systems, contains provisions defining acceptable levels of system safety and emphasizes the system design and its installation. The Underwriters Laboratories, Inc. (UL), document titled: Proposed First Edition of the Standard for Flat Plate Photovoltaic Modules and Panels, UL-1703, identifies module and panel construction requirements that ensure product safety. Together these documents describe requirements intended to minimize hazards such as shock and fire. Although initial focus of these requirements is on single crystal silicon modules, they are generic in nature, and are equally applicable to high voltage ( 30 Vdc), multikilowatt, thin film systems. A major safety concern is insulation breakdown within the module or array wiring system, or discontinuities within the electrical conductors. These failures can result in ground faults, in circuit arcs, or exposure to hazardous electrical parts. Safeguards are discussed.

Sugimura, R. S.↗

Dimension Effects in Insulating NbTiN Disordered Films and the Asymptotic Freedom of Cooper Pairs

This study investigates the evolution of the electronic transport in disordered NbTiN films at the insulating side of the superconductor-insulator transition as function of the effective system size along the current direction. We demonstrate that both, the threshold voltage characterizing low-temperature superinsulating phase, and the Berezinskii-Kosterlitz-Thouless criticality of the conductance above the superinsulator critical temperature, vanish upon increasing disorder taking the system far from the disorder-driven superconductor-insulator transition. We find that decrease in the system's effective size suppresses its insulating and superinsulating properties and that threshold voltage drops linearly with the diminishing system size. We demonstrate that this linear dependence can be used for experimental measurement of the linear tension of the electric string binding Cooper pairs and anti-Cooper pairs in a superinsulator.

36 MATERIALS SCIENCE↗

Price Incentivised Electric Vehicle Charge Control for Community Voltage Regulation

With the growing availability of Electric Vehicles, there is a significant opportunity to use battery 'smart-charging' for voltage regulation. This work designs and experimentally evaluates a system for price-incentivised electric vehicle charging. The system is designed to eliminate negative impacts to the user while minimising the cost of charging and achieving a more favourable voltage behaviour throughout the local grid over time. The practical issues associated with a real-life deployment are identified and resolved. The efficacy of the system is evaluated in the challenging scenario in which EVs are deployed in six closely distributed homes, serviced by the same low voltage residential distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Experimental Data on Open Circuit Voltage Characterization for Li-Ion Batteries

In this article, we present the datasets collected from nine different Li-ion batteries. These datasets contain voltage, current and time measurements during a full charge-discharge cycle of a battery at very low current (that is nearly at �/30 rate). Such low current rate data is suitable for open circuit voltage characterization. The collection of this data was done through the use of an Arbin battery cycler and a thermal chamber was used to control the test temperature. Data were collected over a wide range of temperatures from −25∘C to 50∘C.

Battery management system↗

High voltage testing for the Majorana Demonstrator

The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

high-voltage↗

Evaluation of a Multi-kw, High Frequency Transformer for Space Applications

Various NASA studies have shown that high power (multi-kW and higher) electrical systems for various aerospace applications favor high frequency distribution systems, due to the improved safety and weight factors associated with those systems. Other favorable characteristics include low EMI, minimal wiring and ease of system parameter sensing and control of a single phase system. In aerospace power systems, as in terrestrial AC distribution systems, transformers are needed to provide voltage changes, isolation and the resetting of ground. Under NASA contract NAS3-21948 a multi-kW high frequency transformer was designed, fabricated and tested by Thermal Technology Lab, Inc. of Buffalo, New York. 'The goals of this program included the determination of the relationships between transformer weight, efficiency and operating frequency; low internal temperatures and reduced specific weight; and the validation of these new design concepts through experimentation and the fabrication and testing of transformers and their insulation systems.' The transformer was delivered to NASA-Lewis, where an evaluation program was conducted in Lewis' High Power High Frequency Component Test Facility. The transformer was tested in both atmosphere and under vacuum conditions. This paper will discuss the design of the transformer, the evaluation program and test results, the failures experienced and conclusions.

Roth, Mary Ellen↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Optical properties of blue light-emitting diodes in the InGaN/GaN system at high current densities

The current-voltage and brightness-voltage characteristics and the electroluminescence spectra of blue InGaN/GaN-based light-emitting diodes are studied to clarify the cause of the decrease in the emission efficiency at high current densities and high temperatures. It is found that the linear increase in the emission intensity with increasing injection current changes into a sublinear increase, resulting in a decrease in efficiency as the observed photon energy shifts from the mobility edge. The emission intensity decreases with increasing temperature when the photon energy approaches the mobility edge; this results in the reduction in efficiency on overheating. With increasing temperature, the peak of the electroluminescence spectrum shifts to lower photon energies because of the narrowing of the band gap. The results are interpreted taking into account the fact that the density-of-states tails in InGaN are filled not only via trapping of free charge carriers, but also via tunneling transitions into the tail states. The decrease in the emission efficiency at high currents is attributed to the suppression of tunneling injection and the enhancement of losses via the nonradiative recombination channel 'under' the quantum well.

36 MATERIALS SCIENCE↗

Startup process for a dual active bridge converter to prevent over-voltage failure and thermal run-away

A system and method for controlling a dual active bridge based DC/DC converter. A controller implements a startup control scheme and DC bus pre-charge routine to prevent damage to the converter upon startup. During startup of the converter, the startup control process can be used to prevent excessive phase-shift and the DC bus pre-charge routine adjusts the pulse width modulated duty cycle by increasing the dead time between signals, resulting in a decreased DC bus capacitor.

Singh, Braj K.↗

Magnetic insulation to improve voltage holding in electrostatic accelerators

Voltage holding in high voltage electrostatic accelerators is a longstanding problem which limits the practically obtainable performance of most systems. This paper proposes an idea for improving the voltage holding in electrostatic accelerators by suppressing breakdowns between successive stages of an accelerator. The idea consists of flowing electric currents along the accelerator electrodes to produce magnetic fields which envelope each electrode and its support structure, so as to prevent very low energy electrons from leaving the surfaces of electrodes and subsequently picking up energy from the electric field. In order to be useful in some applications, this magnetic insulation would only need to produce modest gains in voltage holding capability, and its utility can be easily tested experimentally as described herein.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗