Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “regression testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

A Comparison of Modifications to MELCOR versions 1.8.2 and 1.8.6 for ITER Safety Analysis

During the Engineering Design Activity of the International Thermonuclear Experimental Reactor (ITER), the MELCOR 1.8.2 code was selected as one of several codes to be used to perform ITER safety analyses [1]. MELCOR was chosen because it has the capability of predicting coolant pressure, temperature, mass flow rate, and radionuclide and aerosol transport in nuclear facilities and reactor cooling systems. MELCOR can also predict structural temperatures (e.g. first wall, blanket, divertor, and vacuum vessel) resulting from energy produced by radioactive decay heat and/or chemical reactions (oxidation). The Idaho National Laboratory (INL) Fusion Safety Program (FSP) made fusion specific modifications to the MELCOR 1.8.2 code [2-6], including models for water freezing, air condensation, beryllium, carbon, and tungsten oxidation in steam and air environments, flow boiling in coolant loops, and radiation in enclosures, that allowed MELCOR to assess the thermal hydraulic response of ITER cooling systems and the transport of radionuclides as aerosols during accident conditions. Recently, the ITER International Organization (IO) used a “pedigreed” version of MELCOR 1.8.2 [7] to perform accident analyses for ITER’s “Rapport Préliminaire de Sûreté” (Report Preliminary on Safety - RPrS). The MELCOR thermal-hydraulics code [8] is currently under development at the Sandia National Laboratory (SNL) for the US Nuclear Regulatory Commission (NRC). MELCOR is used to model the progression of severe accidents in light water fission reactors. Because MELCOR has undergone many improvements between version 1.8.2 and 1.8.6, the INL FSP decided to introduce fusion modifications into MELCOR 1.8.6, and thereby produce a version of MELCOR 1.8.6 with similar capabilities to the pedigreed version of MELCOR 1.8.2 used for the ITER RPrS. We have applied this version of MELCOR 1.8.6 to the same set of problems used in the MELCOR 1.8.2 pedigree analysis [7]. Section 2 describes a non-regression analysis that involves comparing the results from the modified version of MELCOR 1.8.6 against those predicted by the original, unmodified version of MELCOR 1.8.6. The purpose of this non-regression analysis is to demonstrate that the modifications made to the MELCOR 1.8.6 code do not drastically alter the intended functions of the MELCOR base code, and if they do to explain why the departure occurs and if the change is needed. The analysis was performed using the demonstration problem that came with the MELCOR 1.8.6 source distribution. Section 3 makes a comparison between the pedigreed version of MELCOR 1.8.2 and the new modified version of MELCOR 1.8.6 on a set of accident problems used by the ITER Joint Central Team (JCT) in the Generic Site Safety Report (GSSR) [9]. Finally, in section 4, the two versions of the code are compared on a series of developmental test problems described in the change documents [2-4, 6].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Spectroscopy and Multivariate Analysis for Biodosimetry and Monitoring of Radiation Injury to the Skin

In the event of an intentional or accidental release of ionizing radiation in a densely populated area, timely assessment and triage of the general population for the radiation exposure is critical. In particular, a significant number of the victims may sustain cutaneous radiation injury, which increases the mortality and worsens the overall prognosis of the victims suffered from combined thermal/mechanical and radiation trauma. Diagnosis of the cutaneous radiation injury is challenging, and established methods largely rely on visual manifestations, presence of the skin contamination, and a high degree of recall by the victim. Availability of a high throughput non-invasive in vivo biodosimetry tool for assessment of the radiation exposure of the skin is of particular importance for the timely diagnosis of the cutaneous injury. In the reported investigation, we have tested the potential of an optical reflectance spectroscopy for the evaluation of the radiation injury to the skin. This is technically attractive because optical spectroscopy relies on well-established and routinely used for various applications instrumentation, one example being pulse oximetry which uses selected wavelengths for the quantification of the blood oxygenation. Our method relies on a broad spectral region ranging from the locally absorbed, shallow-penetrating ultraviolet and visible (250 to 800 nm) to more deeply penetrating near-Infrared (800 – 1600 nm) light for the monitoring of multiple physiological changes in the skin upon irradiation. Chemometrics is a multivariate methodology that allows the information from entire spectral region to be used to generate predictive regression models. In this report we demonstrate that simple spectroscopic method, such as the optical reflectance spectroscopy, in combination with multivariate data analysis, offers the promise of rapid and non-invasive in vivo diagnosis and monitoring of the cutaneous radiation exposure, and is able accurately predict the dose and time of exposure in the rodent model.

Levitskaia, Tatiana G↗

SU-F-T-130: [18F]-FDG Uptake Dose Response in Lung Correlates Linearly with Proton Therapy Dose

Purpose: Analysis of clinical outcomes in lung cancer patients treated with protons using 18F-FDG uptake in lung as a measure of dose response. Methods: A test case lung cancer patient was selected in an unbiased way. The test patient’s treatment planning and post treatment positron emission tomography (PET) were collected from picture archiving and communication system at the UT M.D. Anderson Cancer Center. Average computerized tomography scan was registered with post PET/CT through both rigid and deformable registrations for selected region of interest (ROI) via VelocityAI imaging informatics software. For the voxels in the ROI, a system that extracts the Standard Uptake Value (SUV) from PET was developed, and the corresponding relative biological effectiveness (RBE) weighted (both variable and constant) dose was computed using the Monte Carlo (MC) methods. The treatment planning system (TPS) dose was also obtained. Using histogram analysis, the voxel average normalized SUV vs. 3 different doses was obtained and linear regression fit was performed. Results: From the registration process, there were some regions that showed significant artifacts near the diaphragm and heart region, which yielded poor r-squared values when the linear regression fit was performed on normalized SUV vs. dose. Excluding these values, TPS fit yielded mean r-squared value of 0.79 (range 0.61–0.95), constant RBE fit yielded 0.79 (range 0.52–0.94), and variable RBE fit yielded 0.80 (range 0.52–0.94). Conclusion: A system that extracts SUV from PET to correlate between normalized SUV and various dose calculations was developed. A linear relation between normalized SUV and all three different doses was found.

60 APPLIED LIFE SCIENCES↗

Lower Limb Venous Compliance is Different Between Men and Women Following 60 Days of Head-Down Bedrest but Is Not Associated with Venoconstriction Dysfunction

Space flight-induced orthostatic intolerance (OI) is more prevalent in female (F) than male (M) astronauts. The mechanisms explaining the higher incidence of OI in F are unclear. We tested the hypothesis that venous compliance would be higher in F more than M following 6 deg head-down bed rest (BR) and would be associated with constrictor dysfunction. Using 2-D ultrasound, dorsal hand (DHV) and dorsal foot (DFV) vein compliances were determined in 24 subjects (10 F, 14 M; 35 +/- 1 yr) by measuring mean diameter response to increasing congestion pressure (0, 20, 30, and 40 mmHg) before and after 60 d of BR. Constrictor function was assessed by intravenous infusions of Ketorolac (KE; 1.5 ig/min) Phenylephrine (PE; 3160 ng/min), and L-NMMA (50 ig/min). The effects of BR between F vs. M and hand vs. foot were determined using mixed-effects linear regression. DFV but not DHV compliance changed in response to BR (p=0.012). Mean DFV increased significantly (0.903 mm to 1.191mm) in F but decreased in M (1.353 mm to 1.154 mm). DFV constrictor response was not different between sexes in response to BR (KE; p=0.647, PE; p=0.717, and L-NMMA; p=0.825). These BR data suggest that the higher incidence of OI in F astronauts may be related to increased lower limb venous compliance, contributing to blood pooling upon standing. Notably, changes to DFV compliance was not accompanied by impaired constrictor function.

Westby, Christian M.↗

Seismic energy data analysis of Merapi volcano to test the eruption time prediction using materials failure forecast method (FFM)

The test of eruption time prediction is an effort to prepare volcanic disaster mitigation, especially in the volcano’s inhabited slope area, such as Merapi Volcano. The test can be conducted by observing the increase of volcanic activity, such as seismicity degree, deformation and SO2 gas emission. One of methods that can be used to predict the time of eruption is Materials Failure Forecast Method (FFM). Materials Failure Forecast Method (FFM) is a predictive method to determine the time of volcanic eruption which was introduced by Voight (1988). This method requires an increase in the rate of change, or acceleration of the observed volcanic activity parameters. The parameter used in this study is the seismic energy value of Merapi Volcano from 1990 – 2012. The data was plotted in form of graphs of seismic energy rate inverse versus time with FFM graphical technique approach uses simple linear regression. The data quality control used to increase the time precision employs the data correlation coefficient value of the seismic energy rate inverse versus time. From the results of graph analysis, the precision of prediction time toward the real time of eruption vary between −2.86 up to 5.49 days.

42 ENGINEERING↗

Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71.27 ± 17.52 (mm), 61.59 ± 16.98 (mm), 0.01 ± 0.00 (mm{sup −1}), and 34 380.75 ± 6680.06 (mm{sup 2}), respectively. Several parameters were correlated with the PFT parameters. Conclusions: The authors propose an automatic method for quantitatively evaluating the morphological parameters of the diaphragm on volumetric chest CT in COPD patients. By measuring not only the conventional length and surface area but also the shape features of the diaphragm using quadratic 3D surface modeling, the proposed method is especially useful for quantifying diaphragm characteristics. Their method may be useful for assessing morphological diaphragmatic changes in COPD patients.

60 APPLIED LIFE SCIENCES↗

60 Days of Head-down Bedrest Differentially Alters Venous Function in Lower and Upper Body Between Healthy Men and Women

The incidence of orthostatic intolerance after space flight is disproportionally higher in female compared to male crewmembers (83% vs. 20%). Experimental and human data suggest that the loss of orthostatic tolerance is due, at least in part, to microgravity-induced changes in venous compliance and that these changes are specific to the lower body. It is unknown however, whether the changes in venous compliance are different between males and females after space flight, and whether this is related to the disparity in orthostatic intolerance between the sexes. Using 6deg head-down bed rest (BR) as a model of space flight, we tested the following hypotheses; 1) females, compared to males, would experience a greater increase in venous compliance in dorsal foot veins as an effect of BR and 2) no differences in venous compliance would be found in dorsal hand veins between sexes and across BR days. Using 2-D ultrasound, dorsal hand (DHV) and foot vein (DFV) responses (diameter; expressed as sq mm) to 40 mmHg of congestion pressure (compliance) and to intravenous infusion of phenylephrine (PE; 3160ng/min) were determined in 10 females and 16 males before and after 60 days of BR. The relation between changes in vein diameter (in response to pressure and PE), sex, limb, and BR days were determined using a mixed-effect linear regression. It was found that after 60 days of BR, DFV dilator response to pressure was significantly greater in females and significantly less in males compared to pre-BR. As expected, there were no differences in DHV dilator response between sexes nor was there a significant difference between pre and post measures within groups. Notably, the venoconstrictor response to infusions of PE in the DHV and DFV where similar between sexes and across BR days. In conclusion, this study demonstrates that after 60 days of BR, dorsal foot veins are more compliant in women and less compliant in men. Moreover, the changes in lower body vein compliance in females do not appear to be due to changes in vasoconstrictor tone as their response to PE was preserved and similar to that in males. Taken together these data suggest that the higher incidence of orthostatic intolerance in females after space flight is due to increased venous compliance in the lower body which could translate to lower venous filling pressures and a reduced stroke volume.

Westby, Christian M.↗

CAMERA: A method for cost-aware, adaptive, multifidelity, efficient reliability analysis

Estimating probability of failure in aerospace systems is a critical requirement for flight certification and qualification. Failure probability estimation involves resolving tails of probability distributions, and Monte Carlo sampling methods are intractable when expensive high-fidelity simulations have to be queried. Here, we propose a method to use models of multiple fidelities that trade accuracy for computational efficiency. Specifically, we propose the use of multifidelity Gaussian process models to efficiently fuse models at multiple fidelity, thereby offering a cheap surrogate model that emulates the original model at all fidelities. Furthermore, we propose a novel sequential acquisition function based experiment design framework that can automatically select samples from appropriate fidelity models to make predictions about quantities of interest at the highest fidelity. We use our proposed approach in an importance sampling setting and demonstrate our method on the failure level set and probability estimation on synthetic test functions and two real-world applications, namely, the reliability analysis of a gas turbine engine blade using a finite element method and a transonic aerodynamic wing test case using Reynolds-averaged Navier-Stokes equations. We show that our method predicts the failure boundary and probability more accurately and at a fraction of the computational cost compared with using just a single expensive high-fidelity model. Finally, we show that our sequential approach is guaranteed to asymptotically converge to the true failure boundary with high probability.

97 MATHEMATICS AND COMPUTING↗

Collagen Turnover in Relation to Risk Factors and Hemodynamics in Human Intracranial Aneurysms

Determinants for molecular and structural instability, that is, impending growth or rupture, of intracranial aneurysms (IAs) remain uncertain. To elucidate this, we endeavored to estimate the actual turnover rates of the main molecular constituent in human IA (collagen) on the basis of radiocarbon ( 14 C) birth dating in relation to IA hemodynamics. Collagen turnover rates in excised human IA samples were calculated using mathematical modeling of 14 C birth dating data of collagen in relation to risk factors and histological markers for collagen maturity/turnover in selected IA. Hemodynamics were simulated using image-based computational fluid dynamics. Correlation, logistic regression, and receiver operating characteristic analyses were performed. Collagen turnover rates were estimated in 46 IA (43 patients); computational fluid dynamics could be performed in 20 IA (20 patients). The mean collagen turnover rate (γ) constituted 126% (±1% error) per year. For patients with arterial hypertension, γ was greater than 2600% annually, whereas γ was distinctly lower with 32% (±1% error) per year for patients without risk factors, such as smoking and hypertension. There was a distinct association between histological presence of rather immature collagen in human IA and the presence of modifiable risk factors. Spatial-temporal averaged wall shear stress predicted rapid collagen turnover (odds ratio, 1.6 [95% CI, 1.0–2.7]). Receiver operating characteristic analysis demonstrated a good test accuracy (area under the curve, 0.798 [95% CI, 0.598–0.998]) for average wall shear stress with a threshold ≥4.9 Pa for rapid collagen turnover. Our data indicate that turnover rates and stability of collagen in human IA are strongly associated with the presence of modifiable risk factors and aneurysmal hemodynamics. Finally, these findings underline the importance of strict risk factor modification in patients with unruptured IA. Future should include more detailed risk factor data to establish a more causal understanding of hemodynamics and the rupture risk of individual IA.

60 APPLIED LIFE SCIENCES↗

Comparison of methane emission estimates from multiple measurement techniques at natural gas production pads

This study presents the results of a campaign that estimated methane emissions at 268 gas production facilities in the Fayetteville shale gas play using onsite measurements (261 facilities) and two downwind methods - the dual tracer flux ratio method (Tracer Facility Estimate - TFE, 17 facilities) and the EPA Other Test Method 33a (OTM33A Facility Estimate - OFE, 50 facilities). A study onsite estimate (SOE) for each facility was developed by combining direct measurements and simulation of unmeasured emission sources, using operator activity data and emission data from literature. The SOE spans 0-403 kg/h and simulated methane emissions from liquid unloadings account for 88% of total emissions estimated by the SOE, with 76% (95% CI [51%-92%]) contributed by liquid unloading at two facilities. TFE and SOE show overlapping 95% CI between individual estimates at 15 of 16 (94%) facilities where the measurements were paired, while OFE and SOE show overlapping 95% CI between individual estimates at 28 of 43 (65%) facilities. However, variance-weighted least-squares (VWLS) regressions performed on sets of paired estimates indicate statistically significant differences between methods. The SOE represents a lower bound of emissions at facilities where onsite direct measurements of continuously emitting sources are the primary contributor to the SOE, a sub-selection of facilities which minimizes expected inter-method differences for intermittent pneumatic controllers and the impact of episodically-emitting unloadings. At 9 such facilities, VWLS indicates that TFE estimates systematically higher emissions than SOE (TFE-to-SOE ratio = 1.6, 95% CI [1.2 to 2.1]). At 20 such facilities, VWLS indicates that OFE estimates systematically lower emissions than SOE (OFE-to-SOE ratio of 0.41 [0.26 to 0.90]). Given that SOE at these facilities is a lower limit on emissions, these results indicate that OFE is likely a less accurate method than SOE or TFE for this type of facility.

03 NATURAL GAS↗

Understanding and Verifying Neural Networks

Deep Neural Networks (DNNs) have gained immense popularity in recent times and have widespread use in applications such as image classification, sentiment analysis, speech recognition and also in safety-critical applications such as autonomous driving. However, they suffer limitations such as lack of explainability and robustness which raise safety and security concerns in their usage. Further, the complex structure and large input spaces of DNNs act as an impediment to thorough verification and testing. The SafeDNN project at the Robust Software Engineering (RSE) group at NASA aims at exploring techniques to ensure that systems that use deep neural networks are safe, robust and interpretable. In this talk, I will be presenting our technique Prophecy that automatically infers formal properties of deep neural network models. The tool extracts patterns based on neuron activations as preconditions that imply certain desirable output properties of the model. I would be highlighting case studies that use Prophecy in obtaining explanations for network decisions, understanding correct and incorrect behavior, providing formal guarantees wrt safety and robustness, and debugging neural network models. We have applied the tool on image classification networks, neural network controllers providing turn advisories in unmanned aircrafts, regression models used for autonomous center-line tracking in aircrafts and neural network object detectors

Deep Neural Networks↗

Spatial biases of information influence global estimates of soil respiration: how can we improve global predictions?

Soil respiration (Rs), the efflux of CO2 from soils to the atmosphere, is a major component of the terrestrial carbon cycle, but is poorly constrained from regional to global scales. The global soil respiration database (SRDB) is a compilation of in-situ Rs observations from around the globe that has been consistently updated with new measurements over the past decade. It is unclear whether the addition of data to new versions of the SRDB has produced better-constrained global Rs estimates. We compared two versions of the SRDB (v3.0 n=5173 and v5.0 n=10366) to determine how additional data influenced the global sum and uncertainty of Rs as predicted by a quantile regression forest model. A model parameterized using SRDBv3 yielded a global Rs sum of 88.6 Pg C yr-1, and associated uncertainty of 29.9 (mean absolute error) and 57.9 (standard deviation) Pg C yr-1, whereas parameterization using SRDBv5 yielded 96.5 Pg C yr-1 and associated uncertainty of 30.2 (mean average error) and 73.4 (standard deviation) Pg C yr-1. Empirically estimated global heterotrophic respiration (Rh) from v3 and v5 were 49.9-50.2 (mean 50.1) and 53.3-53.5 (mean 53.4) Pg C yr-1, respectively. Interestingly, SRDBv5’s inclusion of new data from underrepresented regions (e.g., Asia, Africa, South America) thus resulted in overall higher model uncertainty. The SRDBv5 is still biased towards northern latitudes and temperate zones, so we tested that an optimized global distribution of Rs measurements resulted in a global sum of 96.4 ± 21.4 Pg C yr-1 and lower model uncertainty. These results support current global estimates of Rs but highlight spatial inconsistencies that influence model parameterization and interpretation that should be addressed to improve regional- to global-scale predictions.

Stell, Emma↗

Predicting Postoperative Injury and Military Discharge Status After Knee Surgery in the US Army

Background: Researchers have assessed postoperative injury or disability predictors in the military setting but typically focused on 1 type of surgical procedure at a time, used relatively small sample sizes, or investigated mixed cohorts with civilian populations. Purpose: To identify the relationship between baseline variables and injury incidence or military discharge status in US Army soldiers after knee surgery. Study Design: Case-control study; Level of evidence, 3. Methods: Data were obtained from a repository containing personnel, performance, and medical records for all active-duty US Army soldiers. Multivariate logistic regressions were used to estimate the effects of numerous variables on postoperative injury or on medical discharge. Variable selection and model validation were conducted using the k-fold method. Results: A total of 7567 soldiers underwent knee surgery between 2017 and 2019. Meniscal procedures were the most common type of surgery (39%), and approximately 71% of the cohort had a postoperative injury. Significant predictors for sustaining a postoperative injury included having a previous nonknee injury (odds ratio [OR], 1.5), female sex (OR, 1.3), and Black race (OR, 1.2). Within 4 years after surgery, 17% of soldiers were discharged from the military because of knee-related disability. Significant predictors for discharge from duty included enlisted rank (OR, 2.3), recent fitness test failure (OR, 1.9), number of previous knee surgeries (OR, 1.7), and having a previous nonknee injury (OR, 1.6). Conclusion: After knee surgery, nearly three-fourths of the soldiers in this cohort sustained a postoperative injury and almost one-fifth of soldiers were medically discharged from the military within 4 years. This study identified variables that indicate statistically increased risk for these postoperative outcomes and highlighted potentially modifiable factors.

Orthopedics↗

HydraGNN_Predictive_GFM_2024 - Ensemble of predictive graph foundation models for ground state atomistic materials modeling

We provide the ensemble of fifteen pre-trained graph foundation models (GFMs) for atomistic materials modeling applications. Each one of the fifteen GFMs has been trained on five open-source datasets that (once aggregated) amount to over 154 million atomistic structures, which cover over two-thirds of the natural elements of the periodic table and that comprises a broad set of organic and inorganic compounds. This vast set of atomistic structures comprises ground state configurations that are dynamically stable (i.e., equilibrated structures with atomic forces approximately close to zero values) as well as dynamically unstable structures (i.e., non-equilibrium structures with non-negligible non-zero values of atomic forces). The ensemble of datasets aggregated does NOT include excited states. The datasets have been curated to remove atomistic structures with spectral norm of the force tensor above 100 eV/angstrom. Moreover, a linear term of the energy was computed for each dataset using a linear regression model that uses the chemical concentration of each natural element as regressor. The linear term predicted by the linear regression model has been subtracted from each original energy value to perform a re-alignment of the energy values across different electronic structures approximation theories performed to generate the diverse multi-source, multi-fidelity datasets. The folder "ADIOS_files" contains the set of pre-processed datasets in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used for the development and training of GFMs in this work. The "ADIOS_files" directory contains 6 sub-directories named as follows: - ANI1x-v3.bp - MPTrj-v3.bp - OC2020-20M-v3.bp - OC2020-v3.bp - OC2022-v3.bp - qm7x-v3.bp Each sub-directory contains the pre-processed datasets converted in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used to the development, training, and performance testing of the ensemble go predictive graph foundation models. Each GFM was developed using HydraGNN (https://github.com/ORNL/HydraGNN) as underlying graph neural network (GNN) architecture. The multi-task learning (MTL) capability of HydraGNN was used to simultaneously train the GFMs on labeled values for direct predictions of energy (a total system property of an atomistic structure that measures the chemical stability) and atomic forces (an atomic level property of an atomistic structure that measures the dynamical stability). The hyper parameters of the GFM have been tuned using scalable hyperparameter optimization (HPO) algorithms implemented in the software DeepHyper (https://github.com/deephyper/deephyper). The pre-training of each HPO trial was performed using distributed data parallelism (DDP) to scale the training across 128 compute nodes of the exascale OLCF supercomputer Frontier. Each HPO trial was trained only for 10 epochs and an early stopping was performed to avoid wasting significant computational resources on GNN architectures that were clearly underperforming. For each HPO trial, the 'omnistat' tool developed by (AMD Research - Advanced Micro Device) was used to measure the total energy consumption in kWh. The ensemble of GFMs was obtained by selecting the fifteen best performing HPO trials. Four models have been selected for their clear advantage in accuracy, and these are the GFMs with IDs 229, 156, 147, 260. Additional eleven models have been selected based on judicious balance between accuracy and energy consumption needed for training, and these are the GFMs with IDs 165, 78, 137, 1, 175, 171, 181, 67, 179, 167, 351. Each selected GFM of the ensemble was continued to cumulate a total of at most 30 epochs. In some cases, the total number of epochs actually performed was les than 30 due to two combined factors: (1) the size of the GFM (i.e., the number of model parameters to train) and (2) the total wall-clock time for which the computational resources could be allocated on OLCF-Frontier. The "Ensemble_of_models" directory contains 15 sub-directories named as follows: - gfm_0.229 - gfm_0.156 - gfm_0.147 - gfm_0.260 - gfm_0.165 - gfm_0.78 - gfm_0.137 - gfm_0.1 - gfm_0.175 - gfm_0.171 - gfm_0.181 - gfm_0.67 - gfm_0.179 - gfm_0.167 - gfm_0.351 Each one of these sub-directories refers to one of the fifteen HPO trials that have been selected to continue the pre-training with at most 30 epochs. With each sub-directory associated with a specific HPO trial, the following files can be found: - config.json: file for argument parsing to develop and train an HydraGNN architecture - gfm_0.ID_epoch_N.pk: file with model parameters for HPO ID trial after N epochs of training The ensemble of fifteen GFM architectures was used for (1) ensemble averaging to stabilize the predictions of energy and atomic forces after pre-training for post-processing analysis and (2) ensemble uncertainty quantification (UQ). The code used to develop, pre-train, and load the pre-trained models for post-processing analysis is available on the ORNL-GitHub at the following link: https://github.com/ORNL/HydraGNN/tree/Predictive_GFM_2024

36 MATERIALS SCIENCE↗

Effects of 14 days of head-down tilt bed rest on cutaneous vasoconstrictor responses in humans

This study tested the hypothesis that head-down tilt bed rest (HDBR) reduces adrenergic and nonadrenergic cutaneous vasoconstrictor responsiveness. Additionally, an exercise countermeasure group was included to identify whether exercise during bed rest might counteract any vasoconstrictor deficits that arose during HDBR. Twenty-two subjects underwent 14 days of strict 6 degrees HDBR. Eight of these 22 subjects did not exercise during HDBR, while 14 of these subjects exercised on a supine cycle ergometer for 90 min a day at 75% of pre-bed rest heart rate maximum. To assess alpha-adrenergic vasoconstrictor responsiveness, intradermal microdialysis was used to locally administer norepinephrine (NE), while forearm skin blood flow (SkBF; laser-Doppler flowmetry) was monitored over microdialysis membranes. Nonlinear regression modeling was used to identify the effective drug concentration that caused 50% of the cutaneous vasoconstrictor response (EC(50)) and minimum values from the SkBF-NE dose-response curves. In addition, the effects of HDBR on nonadrenergic cutaneous vasoconstriction were assessed via the venoarteriolar response of the forearm and leg. HDBR did not alter EC(50) or the magnitude of cutaneous vasoconstriction to exogenous NE administration regardless of whether the subjects exercised during HDBR. Moreover, HDBR did not alter the forearm venoarteriolar response in either the control or exercise groups during HDBR. However, HDBR significantly reduced the magnitude of cutaneous vasoconstriction due to the venoarteriolar response in the leg, and this response was similarly reduced in the exercise group. These data suggest that HDBR does not alter cutaneous vasoconstrictor responses to exogenous NE administration, whereas cutaneous vasoconstriction of the leg due to the venoarteriolar response is reduced after HDBR. It remains unclear whether attenuated venoarteriolar responses in the lower limbs contribute to reduced orthostatic tolerance after bed rest and spaceflight.

NASA Discipline Cardiopulmonary↗

Non-Targeted Effects and the Dose Response for Heavy Ion Tumorigenesis

BACKGROUND: There is no human epidemiology data available to estimate the heavy ion cancer risks experienced by astronauts in space. Studies of tumor induction in mice are a necessary step to estimate risks to astronauts. Previous experimental data can be better utilized to model dose response for heavy ion tumorigenesis and plan future low dose studies. DOSE RESPONSE MODELS: The Harderian Gland data of Alpen et al.[1-3] was re-analyzed [4] using non-linear least square regression. The data set measured the induction of Harderian gland tumors in mice by high-energy protons, helium, neon, iron, niobium and lanthanum with LET s ranging from 0.4 to 950 keV/micron. We were able to strengthen the individual ion models by combining data for all ions into a model that relates both radiation dose and LET for the ion to tumor prevalence. We compared models based on Targeted Effects (TE) to one motivated by Non-targeted Effects (NTE) that included a bystander term that increased tumor induction at low doses non-linearly. When comparing fitted models to the experimental data, we considered the adjusted R2, the Akaike Information Criteria (AIC), and the Bayesian Information Criteria (BIC) to test for Goodness of fit.In the adjusted R2test, the model with the highest R2values provides a better fit to the available data. In the AIC and BIC tests, the model with the smaller values of the summary value provides the better fit. The non-linear NTE models fit the combined data better than the TE models that are linear at low doses. We evaluated the differences in the relative biological effectiveness (RBE) and found the NTE model provides a higher RBE at low dose compared to the TE model. POWER ANALYSIS: The final NTE model estimates were used to simulate example data to consider the design of new experiments to detect NTE at low dose for validation. Power and sample sizes were calculated for a variety of radiation qualities including some not considered in the Harderian Gland data set and with different background tumor incidences. We considered different experimental designs with varying number of doses and varying low doses dependant on the LET of the radiation. The optimal design to detect a NTE for an individual ion had 4 doses equally spaced below a maximal dose where bending due to cell sterilization was < 2%. For example at 100 keV/micron we would irradiate at 0.03 Gy, 0.065 Gy, 0.13 Gy, and 0.26 Gy and require 850 mice including a control dose for a sensitivity to detect NTE with 80% power. Sample sizes could be improved by combining ions similar to the methods used with the Harderian Gland data.

Chappelli, Lori J.↗

Mitigating contamination in LSS surveys: a comparison of methods

ABSTRACT Future large-scale structure surveys will measure the locations and shapes of billions of galaxies. The precision of such catalogues will require meticulous treatment of systematic contamination of the observed fields. We compare several existing methods for removing such systematics from galaxy clustering measurements. We show how all the methods, including the popular pseudo-Cℓ Mode Projection and Template Subtraction methods, can be interpreted under a common regression framework and use this to suggest improved estimators. We show how methods designed to mitigate systematics in the power spectrum can be used to produce clean maps, which are necessary for cosmological analyses beyond the power spectrum, and we extend current methods to treat the next-order multiplicative contamination in observed maps and power spectra, which reduced power spectrum errors from $\Delta \chi ^2_{\rm C_\ell }\simeq 10$ to ≃ 1 in simulated analyses. Two new mitigation methods are proposed, which incorporate desirable features of current state-of-the-art methods while being simpler to implement. Investigating the performance of all the methods on a common set of simulated measurements from Year 5 of the Dark Energy Survey, we test their robustness to various analysis cases. Our proposed methods produce improved maps and power spectra when compared to current methods, while requiring almost no user tuning. We end with recommendations for systematics mitigation in future surveys, and note that the methods presented are generally applicable beyond the galaxy distribution to any field with spatial systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Normal Tissue Complication Probability Analysis of Acute Gastrointestinal Toxicity in Cervical Cancer Patients Undergoing Intensity Modulated Radiation Therapy and Concurrent Cisplatin

Purpose: To test the hypothesis that increased bowel radiation dose is associated with acute gastrointestinal (GI) toxicity in cervical cancer patients undergoing concurrent chemotherapy and intensity-modulated radiation therapy (IMRT), using a previously derived normal tissue complication probability (NTCP) model. Methods: Fifty patients with Stage I-III cervical cancer undergoing IMRT and concurrent weekly cisplatin were analyzed. Acute GI toxicity was graded using the Radiation Therapy Oncology Group scale, excluding upper GI events. A logistic model was used to test correlations between acute GI toxicity and bowel dosimetric parameters. The primary objective was to test the association between Grade {>=}2 GI toxicity and the volume of bowel receiving {>=}45 Gy (V{sub 45}) using the logistic model. Results: Twenty-three patients (46%) had Grade {>=}2 GI toxicity. The mean (SD) V{sub 45} was 143 mL (99). The mean V{sub 45} values for patients with and without Grade {>=}2 GI toxicity were 176 vs. 115 mL, respectively. Twenty patients (40%) had V{sub 45} >150 mL. The proportion of patients with Grade {>=}2 GI toxicity with and without V{sub 45} >150 mL was 65% vs. 33% (p = 0.03). Logistic model parameter estimates V50 and {gamma} were 161 mL (95% confidence interval [CI] 60-399) and 0.31 (95% CI 0.04-0.63), respectively. On multivariable logistic regression, increased V{sub 45} was associated with an increased odds of Grade {>=}2 GI toxicity (odds ratio 2.19 per 100 mL, 95% CI 1.04-4.63, p = 0.04). Conclusions: Our results support the hypothesis that increasing bowel V{sub 45} is correlated with increased GI toxicity in cervical cancer patients undergoing IMRT and concurrent cisplatin. Reducing bowel V{sub 45} could reduce the risk of Grade {>=}2 GI toxicity by approximately 50% per 100 mL of bowel spared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗