Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

High-temperature Raman spectroscopy of K 2 Ca(CO 3 ) 2 bütschliite and Na 2 Ca 2 (CO 3 ) 3 shortite

Raman spectra of Na 2 Ca 2 (CO 3 ) 3 shortite and K 2 Ca(CO 3 ) 2 bütschliite were measured to 715°C and 740°C respectively, under vacuum. The vibrational spectra demonstrate that shortite converts to nyerereite (Na 2 Ca(CO 3 ) 2 ) and calcite at 535°C. This assemblage is stable to ~700°C, where nyerereite begins to decompose. Bütschliite converts to the isochemical phase fairchildite at 570°C, which is stable to 665°C, where it decomposes to an assemblage of K 2 CO 3 and CaO. The variation of anharmonicity between different vibrational modes of each of the low temperature phases is assessed, and these yield insights into inter-carbonate group couplings. In conclusion, both fairchildite and nyerereite exhibit spectral features consistent with extensive disordering.

58 GEOSCIENCES↗

Raman Scattering Sensor for On-Line Monitoring of Amines and Acid Gases

Sulfur and CO2 removal from hydrocarbon streams and power plant effluents are a major problem. The sulfur is normally in the form of H2S. These two acid gases are scrubbed using aqueous amine solutions that are difficult to control with conventional technology. Process Instruments Inc. developed Raman scattering technology for on-line, real-time monitoring of amine streams to improve their efficiency in scrubbing H2S and CO2 from hydrocarbon streams and power plant effluents. Improved control of amine and acid gas concentrations will allow refineries, natural gas processes and power plants to more efficiently scrub Sulfur and CO2, saving energy, time and financial resources.

02 PETROLEUM↗

Raman Lidar Water Vapor Mixing Ratio and Temperature Value-Added Products

This report describes the methods used to estimate profiles of water vapor mixing ratio (WVMR) and temperature from the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility Raman lidars (RL). This includes a description of the equations and the calibration methods that are used, as well as the output datastreams and variable names. We begin with an overview of the ARM RL systems, with a focus on the detection channels used for the WVMR and temperature measurements.

54 ENVIRONMENTAL SCIENCES↗

Calibration of Raman Spectrometer for Gas Phase Measurements

Raman spectroscopy is currently used at SRNL to measure the concentration of gaseous species evolved from chemical reactions. This report documents the methods used to calibrate the spectroscopic systems in both frequency and intensity spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyperspectral Light Sheet Raman Imaging of Leaf Metabolism (Final Report)

This final technical report details the accomplishment and findings of a project that developed technology related to imaging metabolic processes in plants. The report gives technical details of the design, construction and characterization of a Raman microscope system capable of identifying chemical species using the wavelength shifts of scattered excitation light. Some of the unique aspects of the design include: use of a Bessel beam excitation source, which allow long excitation lines that are resistant to scattering in complex media such as plants; excitation at 785 nm to avoid fluorescence emission that can occur in photosynthetic organisms; and a flat optical design that makes construction and alignment significantly simpler. This project also used stable isotope labeling to look at photorespiratory flux in the leaves of three different types of plants that have different photosynthesis pathways. Gas chromatography–mass spectrometry was used to look at which metabolites and amino acids had altered oxygen, carbon and hydrogen uptake under various conditions of environmental oxygen. This generated a rich data set that is being further analyzed to understand metabolic pathways in plants. This project also used the natural fluorescence in sorghum and rice to conduct an extensive experiment across different developmental stages. Spectral differences were identified at most of the developmental stages and these can be attributed to differential pigment and pigment-protein complexes present in different relative abundances as the plant develops.

09 BIOMASS FUELS↗

Handheld Raman Spectrometers: Assessment Report

In April 2022 the National Urban Security Technology Laboratory’s System Assessment and Validation for Emergency Responders program conducted an operational assessment of ten commercially available handheld Raman spectrometers. Additionally, prior to the operational assessment, the Pacific Northwest National Laboratory conducted laboratory testing of the devices, including scanning a number of samples in various containers. This report summarizes the results of the assessment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Detuning and Wavebreaking Effects on Raman Amplification Effciency in Plasma

A plasma-based resonant backward Raman amplifier/compressor for high power amplification of short laser pulses might, under ideal conditions, convert as much as 90% of the pump energy to the seed pulse. While the theoretical highest possible efficiency of this scheme has not yet been achieved, larger efficiencies than ever before obtained experimentally (6.4%) are now being reported, and these efficiencies are accompanied by strong pulse compression. Based on these recent extensive experiments, it is now possible to deduce that the experimentally realized efficiency of the amplifier is likely constrained by two factors, namely the pump chirp and the plasma wavebreaking, and that these experimental observations may likely involve favorable compensation between the chirp of the laser and the density variation of the mediating plasma. Several methods for further improvement of the amplifier effciency in current experiments are suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SERS Raman Sensor Based on Diameter-Modulated Sapphire Fiber

Surface enhanced Raman scattering (SERS) has been observed using a sapphire fiber coated with gold nano-islands for the first time. The effect was found to be much weaker than what was observed with a similar fiber coated with silver nanoparticles. Diameter-modulated sapphire fibers have been successfully fabricated on a laser heated pedestal growth system. Such fibers have been found to give a modest increase in the collection efficiency of induced emission. However, the slow response of the SERS effect makes it unsuitable for process control applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Early Diagnosis of Fibromyalgia Using Surface-Enhanced Raman Spectroscopy Combined with Chemometrics

Fibromyalgia (FM) is a chronic muscle pain disorder that shares several clinical features with other related rheumatologic disorders. This study investigates the feasibility of using surface-enhanced Raman spectroscopy (SERS) with gold nanoparticles (AuNPs) as a fingerprinting approach to diagnose FM and other rheumatic diseases such as rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), osteoarthritis (OA), and chronic low back pain (CLBP). Blood samples were obtained on protein saver cards from FM (n = 83), non-FM (n = 54), and healthy (NC, n = 9) subjects. A semi-permeable membrane filtration method was used to obtain low-molecular-weight fraction (LMF) serum of the blood samples. SERS measurement conditions were standardized to enhance the LMF signal. An OPLS-DA algorithm created using the spectral region 750 to 1720 cm -1 enabled the classification of the spectra into their corresponding FM and non-FM classes (Rcv > 0.99) with 100% accuracy, sensitivity, and specificity. The OPLS-DA regression plot indicated that spectral regions associated with amino acids were responsible for discrimination patterns and can be potentially used as spectral biomarkers to differentiate FM and other rheumatic diseases. This exploratory work suggests that the AuNP SERS method in combination with OPLS-DA analysis has great potential for the label-free diagnosis of FM.

60 APPLIED LIFE SCIENCES↗

Raman Scattering as a Probe of the Magnetic State of BEDT-TTF Based Mott Insulators

Quasi-two-dimensional Mott insulators based on BEDT-TTF molecules have recently demonstrated a variety of exotic states, which originate from electron-electron correlations and geometrical frustration of the lattice. Among those states are a triangular S = 1/2 spin liquid and quantum dipole liquid. Here in this article, we show the power of Raman scattering technique to characterize magnetic and electronic excitations of these states. Our results demonstrate a distinction between a spectrum of magnetic excitations in a simple Mott insulator with antiferromagnetic interactions, and a spectrum of an insulator with an additional on-site charge degree of freedom.

36 MATERIALS SCIENCE↗

The Design and Optimization of Plasmonic Crystals for Surface Enhanced Raman Spectroscopy Using the Finite Difference Time Domain Method

We present computational studies of quasi three-dimensional nanowell (NW) and nanopost (NP) plasmonic crystals for applications in surface enhanced Raman spectroscopy (SERS). The NW and NP plasmonic crystals are metal coated arrays of cylindrical voids or posts, respectively, in a dielectric substrate characterized by a well/post diameter ( D ), relief depth ( RD ), periodicity ( P ), and metal thickness ( MT ). Each plasmonic crystal is modeled using the three-dimensional finite-difference time-domain (FDTD) method with periodic boundary conditions in the x- and y-directions applied to a computational unit cell to simulate the effect of a periodic array.

36 MATERIALS SCIENCE↗

Topaz, a Potential Volatile-Carrier in Cold Subduction Zone: Constraint from Synchrotron X-ray Diffraction and Raman Spectroscopy at High Temperature and High Pressure

The equation of state and stability of topaz at high-pressure/high-temperature conditions have been investigated by in situ synchrotron X-ray diffraction (XRD) and Raman spectroscopy in this study. No phase transition occurs on topaz over the experimental pressure–temperature ($P-T$) range. The pressure–volume data were fitted by the third-order Birch–Murnaghan equation of state (EoS) with the zero-pressure unit–cell volume V 0 = 343.86 (9) Å 3 , the zero-pressure bulk modulus K 0 = 172 (3) GPa, and its pressure derivative K’ 0 = 1.3 (4), while the obtained K 0 = 155 (2) GPa when fixed K’ 0 = 4. In the pressure range of 0–24.4 GPa, the vibration modes of in-plane bending OH-groups for topaz show non-linear changes with the increase in pressure, while the other vibration modes show linear changes. Moreover, the temperature–volume data were fitted by Fei’s thermal equation with the thermal expansion coefficient α 300 = 1.9 (1) × 10 –5 K –1 at 300 K. Finally, the $P-T$ stability of topaz was studied by a synchrotron-based single-crystal XRD at simultaneously high $P-T$ conditions up to ~10.9 GPa and 700 K, which shows that topaz may maintain a metastable state at depths above 370 km in the upper mantle along the coldest subducting slab geotherm. Thus, topaz may be a potential volatile-carrier in the cold subduction zone. It can carry hydrogen and fluorine elements into the deep upper mantle and further affect the geochemical behavior of the upper mantle.

36 MATERIALS SCIENCE↗

An Investigation of the Ice Cloud Detection Sensitivity of Cloud Radars Using the Raman Lidar at the ARM SGP Site

The ice cloud detection sensitivity of the millimeter cloud radar (MMCR) and the Ka-band Zenith radar (KAZR) is investigated using a collocated Raman lidar (RL) at the Atmospheric Radiation Measurement Program Southern Great Plains site. Only profiles that are transparent to the RL with ice clouds only are considered in this study. The MMCR underestimates the RL ice cloud optical depth (COD) by 20%. The MMCR detects no ice clouds in 37% of the profiles. These profiles where ice cloud goes undetected by the MMCR typically contain very optically thin clouds, with a mean RL ice COD of 0.03. Higher ice cloud detection sensitivity is found for the KAZR, which underestimates the RL ice COD by 15%. The decrease in the ice COD bias for the KAZR compared to the MMCR is largely due to a decrease in the ice COD bias for the situation where the transparent profiles with ice clouds are detected by both the RL and cloud radar. The climatic net ice cloud radiative effects (CREs) from the RL at the top of the atmosphere (TOA) and the surface are 3.2 W m−2 and −0.6 W m−2, respectively. The ice CREs at the TOA and surface are underestimated for the MMCR by 0.7 W m−2 and 0.16 W m−2 (21% and 29%) and underestimated for the KAZR by 0.6 W m−2 and 0.14 W m−2 (17% and 24%). The ice clouds undetected by the cloud radars led to underestimating the climatic net cloud heating rates below 150 hPa by about 0–0.04 K day−1.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Long-Term Monitoring of the Circulating Gases in the KATRIN Experiment Using Raman Spectroscopy

The Karlsruhe Tritium Neutrino (KATRIN) experiment aims at measuring the effective electron neutrino mass with a sensitivity of 0.2 eV/c2, i.e., improving on previous measurements by an order of magnitude. Neutrino mass data taking with KATRIN commenced in early 2019, and after only a few weeks of data recording, analysis of these data showed the success of KATRIN, improving on the known neutrino mass limit by a factor of about two. This success very much could be ascribed to the fact that most of the system components met, or even surpassed, the required specifications during long-term operation. Here, we report on the performance of the laser Raman (LARA) monitoring system which provides continuous high-precision information on the gas composition injected into the experiment’s windowless gaseous tritium source (WGTS), specifically on its isotopic purity of tritium—one of the key parameters required in the derivation of the electron neutrino mass. The concentrations cx for all six hydrogen isotopologues were monitored simultaneously, with a measurement precision for individual components of the order 10−3 or better throughout the complete KATRIN data taking campaigns to date. From these, the tritium purity, εT, is derived with precision of <10−3 and trueness of <3 × 10−3, being within and surpassing the actual requirements for KATRIN, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water vapor mixing ratio from Raman Lidar

The data set represents output from a revised version of the Raman lidar water vapor mixing ratio VAP, which will replace the older mixing ratio VAP.

54 ENVIRONMENTAL SCIENCES↗

Water vapor mixing ratio from Raman Lidar

The data set represents output from a revised version of the Raman lidar water vapor mixing ratio VAP, which will replace the older mixing ratio VAP.

54 ENVIRONMENTAL SCIENCES↗

ARM SGP PBLH and MLH datasets from Raman lidar and Doppler lidar

The planetary boundary layer (PBL) plays a critical role in the atmosphere by transferring heat, moisture, and momentum. The warm PBL has a distinct diurnal cycle including the daytime convective mixing layer (ML) and nighttime residual layer developments. Thus, simultaneous determinations of PBL height (PBLH) and ML height (MLH) are necessary for studying PBL characterization and processes. Here, new approaches are developed to provide reliable PBLH and MLH estimates to characterize warm PBL evolution. The approaches use Raman lidar (RL) water vapor mixing ratio (WVMR) and Doppler lidar (DL) vertical velocity measurements at the Southern Great Plains (SGP) atmospheric observatory, which was established by the Atmospheric Radiation Measurement (ARM) User Facility. Compared to widely used lidar aerosol measurements for PBLH, WVMR is a better tracer for PBL vertical mixing. For PBLH, the approach classifies PBL water vapor structures into a few general patterns, then uses a slope method and dynamic threshold method to determine PBLH. For MLH, wavelet analysis is used to reconstruct 2D variance from DL vertical wind velocity measurements according to the turbulence eddy size to minimize the impacts of gravity wave and eddy size on variance calculations; then, a dynamic threshold method is used to determine MLH. Remotely-sensed PBLHs and MLHs are compared with radiosonde measurements based on the Richardson number method. Good agreements between them confirm that the proposed new algorithms are reliable for PBLH and MLH characterization. The algorithms are applied to warm-season RL and ML measurements at the SGP site for five years to study warm-season PBL structure and processes. The weekly composited diurnal evolutions of PBLHs and MLHs in a warm climate were provided to illustrate diurnal and seasonal PBL evolutions. This reliable data set of PBLH and MLH values will be valuable for studying PBL processes, model evolution, and PBL parameterization improvements. The MLH dataset includes the MLH in values of km above ground level. The PBLH dataset includes the PBLH in values of km above ground level, along with a flag ("situation_PBLH") to determine the state of the PBL (1 = Cloudy Condition, 2 = Stable Layer, 3 = Multi-layer WVMR structure, 4 = Well-Mixed PBL, 5 = A de-coupled layer, 6 = Other).

mixing layer height↗