Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

SU-E-T-174: Evaluation of the Optimal Intensity Modulated Radiation Therapy Plans Done On the Maximum and Average Intensity Projection CTs

Purpose: To determine the difference in coverage between plans done on average intensity projection and maximum intensity projection CT data sets for lung patients and to establish correlations between different factors influencing the coverage. Methods: For six lung cancer patients, 10 phases of equal duration through the respiratory cycle, the maximum and average intensity projections (MIP and AIP) from their 4DCT datasets were obtained. MIP and AIP datasets had three GTVs delineated (GTVaip — delineated on AIP, GTVmip — delineated on MIP and GTVfus — delineated on each of the 10 phases and summed up). From the each GTV, planning target volumes (PTV) were then created by adding additional margins. For each of the PTVs an IMRT plan was developed on the AIP dataset. The plans were then copied to the MIP data set and were recalculated. Results: The effective depths in AIP cases were significantly smaller than in MIP (p < 0.001). The Pearson correlation coefficient of r = 0.839 indicates strong degree of positive linear relationship between the average percentage difference in effective depths and average PTV coverage on the MIP data set. The V2 0 Gy of involved lung depends on the PTV coverage. The relationship between PTVaip mean CT number difference and PTVaip coverage on MIP data set gives r = 0.830. When the plans are produced on MIP and copied to AIP, r equals −0.756. Conclusion: The correlation between the AIP and MIP data sets indicates that the selection of the data set for developing the treatment plan affects the final outcome (cases with high average percentage difference in effective depths between AIP and MIP should be calculated on AIP). The percentage of the lung volume receiving higher dose depends on how well PTV is covered, regardless of on which set plan is done.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-15: Model-Based Multiscale Noise Reduction On Low Dose Cone Beam Projection

Purpose: To improve image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low dose cone beam CT (CBCT) imaging systems, Poisson process governs the randomness of photon fluence at x-ray source and the detector because of the independent binomial process of photon absorption in medium. On a CBCT projection, the variance of fluence consists of the variance of noiseless imaging structure and that of Poisson noise, which is proportional to the mean (noiseless) of the fluence at the detector. This requires multiscale filters to smoothen noise while keeping the structure information of the imaged object. We used a mathematical model of Poisson process to design multiscale filters and established the balance of noise correction and structure blurring. The algorithm was checked with low dose kilo-voltage CBCT projections acquired from a Varian OBI system. Results: From the investigation of low dose CBCT of a Catphan phantom and patients, it showed that our model-based multiscale technique could efficiently reduce noise and meanwhile keep the fine structure of the imaged object. After the image processing, the number of visible line pairs in Catphan phantom scanned with 4 ms pulse time was similar to that scanned with 32 ms, and soft tissue structure from simulated 4 ms patient head-and-neck images was also comparable with scanned 20 ms ones. Compared with fixed-scale technique, the image quality from multiscale one was improved. Conclusion: Use of projection-specific multiscale filters can reach better balance on noise reduction and structure information loss. The image quality of low dose CBCT can be improved by using multiscale filters.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-08: The Relative Accuracy of 4D Dose Accumulation for Lung Radiotherapy Using Rigid Dose Projection Versus Dose Recalculation On Every Breathing Phase

Purpose: To investigate the accuracy of 4D dose accumulation using projection of dose calculated on the end-exhalation, mid-ventilation, or average intensity breathing phase CT scan, versus dose accumulation performed using full Monte Carlo dose recalculation on every breathing phase. Methods: Radiotherapy plans were analyzed for 10 patients with stage I-II lung cancer planned using 4D-CT. SBRT plans were optimized using the dose calculated by a commercially-available Monte Carlo algorithm on the end-exhalation 4D-CT phase. 4D dose accumulations using deformable registration were performed with a commercially available tool that projected the planned dose onto every breathing phase without recalculation, as well as with a Monte Carlo recalculation of the dose on all breathing phases. The 3D planned dose (3D-EX), the 3D dose calculated on the average intensity image (3D-AVE), and the 4D accumulations of the dose calculated on the end-exhalation phase CT (4D-PR-EX), the mid-ventilation phase CT (4D-PR-MID), and the average intensity image (4D-PR-AVE), respectively, were compared against the accumulation of the Monte Carlo dose recalculated on every phase. Plan evaluation metrics relating to target volumes and critical structures relevant for lung SBRT were analyzed. Results: Plan evaluation metrics tabulated using 4D-PR-EX, 4D-PR-MID, and 4D-PR-AVE differed from those tabulated using Monte Carlo recalculation on every phase by an average of 0.14±0.70 Gy, - 0.11±0.51 Gy, and 0.00±0.62 Gy, respectively. Deviations of between 8 and 13 Gy were observed between the 4D-MC calculations and both 3D methods for the proximal bronchial trees of 3 patients. Conclusions: 4D dose accumulation using projection without re-calculation may be sufficiently accurate compared to 4D dose accumulated from Monte Carlo recalculation on every phase, depending on institutional protocols. Use of 4D dose accumulation should be considered when evaluating normal tissue complication probabilities as well as in clinical situations where target volumes are directly inferior to mobile critical structures.

60 APPLIED LIFE SCIENCES↗

WE-G-BRB-02: The Role of Program Project Grants in Study of 3D Conformal Therapy, Dose Escalation and Motion Management

Over the past 20 years the NIH has funded individual grants, program projects grants, and clinical trials which have been instrumental in advancing patient care. The ways that each grant mechanism lends itself to the different phases of translating research into clinical practice will be described. Major technological innovations, such as IMRT and proton therapy, have been advanced with R01-type and P01-type funding and will be discussed. Similarly, the role of program project grants in identifying and addressing key hypotheses on the potential of 3D conformal therapy, normal tissue-guided dose escalation and motion management will be described. An overview will be provided regarding how these technological innovations have been applied to multi-institutional NIH-sponsored trials. Finally, the panel will discuss regarding which research questions should be funded by the NIH to inspire the next advances in radiation therapy. Learning Objectives: Understand the different funding mechanisms of the NIH Learn about research advances that have led to innovation in delivery Review achievements due to NIH-funded program project grants in radiotherapy over the past 20 years Understand example advances achieved with multi-institutional clinical trials NIH.

60 APPLIED LIFE SCIENCES↗

3D localization of electrophysiology catheters from a single x-ray cone-beam projection

Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied. The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm, 0.093 mm, 2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to characterize performance in clinical images as well as the sensitivity to clinical image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Numerical simulation projects in micromagnetics with Jupyter

We report a case study where an existing materials science course was modified to include numerical simulation projects on the micromagnetic behavior of materials. The Ubermag micromagnetic simulation software package is used in order to solve problems computationally. The simulation software is controlled through the Python code in Jupyter notebooks. Our experience is that the self-paced problem-solving nature of the project work can facilitate a better in-depth exploration of the course contents. We discuss which aspects of the Ubermag and the project Jupyter ecosystem have been beneficial for the students' learning experience and which could be transferred to similar teaching activities in other subject areas.

97 MATHEMATICS AND COMPUTING↗

Status of NICA project

The project of Nuclotron-based Ion Collider fAcility NICA/MPD (+MultiPurpose Detector) under development at JINR (Dubna) is presented. The general goals of the project are providing of colliding beams for experimental studies of both hot and dense strongly interacting baryonicmatter and search for the mixed phase and critical endpoint and spin physics in collisions of polarized protons (deuterons). The first program requires providing of heavy-ion collisions in the energy range of {radical}s{sub NN} = 4 - 11 GeV at average luminosity of L = 1 Multiplication-Sign 10{sup 27} cm{sup -2} s{sup -1} for {sup 197}Au{sup 79+}. The polarized beams mode is proposed to be used in energy range of {radical}s = 12 - 27 GeV (protons) at luminosity of L {>=} 1 Multiplication-Sign 10{sup 30} cm{sup -2} s{sup -1}. The report contains description of the facility scheme and characteristics in heavy-ion operation mode, status and plans of the project development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ZFITTER project

The ZFITTER project is aimed at the computation of high-precision theoretical predictions for various observables in high-energy electron-positron annihilation and other processes. The stages of the project development are described. Accent is made on applications to the analysis of LEP data. The present status of the project and perspectives are given as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Project Nuclotron-based Ion Collider fAcility at JINR

The project of Nuclotron-based Ion Collider fAcility (NICA) that is under development at JINR (Dubna) is presented. The general goals of the project are experimental studies of both hot and dense baryonic matter and spin physics (in collisions of polarized protons and deuterons). The first program requires providing of heavy ion collisions in the energy range of √(s{sub NN}) = 4–11 Gev at average luminosity of L = 1 × 10{sup 27} cm{sup −2} s{sup −1} for {sup 197}Au{sup 79+} nuclei. The polarized beams mode is proposed to be used in energy range of √(s{sub NN}) = 12–27 Gev (protons at luminosity of L ≥ 1 × 10{sup 30} cm{sup −2} s{sup −1}. The report contains description of the facility scheme and its characteristics in heavy ion operation mode. The Collider will be equipped with two detectors—MultiPurpose Detector (MPD), which is in an active stage of construction, and Spin Physics Detector (SPD) that is in the stage of conceptual design. Fixed target experiment “Baryonic matter at Nuclotron” (BM@N) will be performed in very beginning of the project. The wide program of applied researches at NICA facility is being developed as well.

43 PARTICLE ACCELERATORS↗

PIPES (Pipeline for Integrated Projects in Energy Systems) [SWR-24-89]

The Pipeline for Integrated Projects in Energy Systems (PIPES) is a comprehensive project, data, and workflow management tool designed for integrated modeling teams. PIPES facilitates the management of data requirements, tasks, and progress tracking, serving as a higher-level integration layer that works across various data and modeling software. This tool integrates models, data, and tools to perform large-scale, integrated analysis work at scale. PIPES is designed to streamline integrated modeling projects, enhance collaboration, and ensure the quality and efficiency of data management and workflow processes. https://github.com/nrel-pipes/pipes-api https://github.com/nrel-pipes/pipes-web https://github.com/nrel-pipes/nrel-pipes

Gu, Jianli↗

Evolving Obs4MIPs to Support Phase 6 of the Coupled Model Intercomparison Project (CMIP6)

Over the past four years, an initiative known as Observations for Model Intercomparison Projects (Obs4MIPs) has successfully completed its pilot phase by adopting a set of technical protocols (dataset format, metadata standards, and documentation requirements) for dataset contributions, producing datasets that conform to these standards and archiving them for distribution on the Earth System Grid Federation (ESGF) alongside the fifth phase of the Coupled Model Intercomparison Project (CMIP5) model output. This pilot phase of Obs4MIPs, initiated by the National Aeronautics and Space Administration’s (NASA) Jet Propulsion Laboratory (JPL) and the Department of Energy’s (DOE) Program for Climate Model Diagnosis and Intercomparison (PCMDI) at Lawrence Livermore National Laboratory, supported CMIP5 and provided a path to improve the coordination between observational communities and major climate modeling intercomparison projects such as CMIP. Obs4MIPs is now being embraced by the international community, with the World Climate Research Programme (WCRP) Data Advisory Council (WDAC) empaneling a task team to provide guidance and governance for Obs4MIPs at an international level, in conjunction with the existing NASA Science Working Group that is more tightly focused on NASA satellite data products. Here, following the example of the first DOE–NASA Obs4MIPs meeting, and with an initial design of CMIP6 being published, a meeting of over 50 experts in both climate modeling and satellite data from the United States, Europe, Japan, and Australia convened at NASA headquarters in Washington, D.C., for the purpose of planning the evolution of Obs4MIPs and its connection to the CMIP6 experiments.

54 ENVIRONMENTAL SCIENCES↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part III: Variability

Abstract Daily expected wind power production from operating wind farms across North America are used to evaluate capacity factors (CF) computed using simulation output from the Weather Research and Forecasting (WRF) Model and to condition statistical models linking atmospheric conditions to electricity production. In Parts I and II of this work, we focus on making projections of annual energy production and the occurrence of electrical production drought. Here, we extend evaluation of the CF projections for sites in the Northeast, Midwest, southern Great Plains (SGP), and southwest U.S. coast (SWC) using statewide wind-generated electricity supply to the grid. We then quantify changes in the time scales of CF variability and the seasonality. Currently, wind-generated electricity is lowest in summer in each region except SWC, which causes a substantial mismatch with electricity demand. While electricity of residential heating may shift demand, research presented here suggests that summertime CF are likely to decline, potentially exacerbating the offset between seasonal peak power production and current load. The reduction in summertime CF is manifest for all regions except the SGP and appears to be linked to a reduction in synoptic-scale variability. Using fulfillment of 50% and 90% of annual energy production to quantify interannual variability, it is shown that wind power production exhibits higher (earlier fulfillment) or lower (later fulfillment) production for periods of over 10–30 years as a result of the action of internal climate modes. Significance Statement Electrical power system reassessment and redesign may be needed to aid efficient increased use of variable renewables in the generation of electricity. Currently wind-generated electricity in many regions of North America exhibits a minimum in summertime and hence is not well synchronized with electricity demand, which tends to be maximized in summer. Future projections indicate evidence of reductions in wind power during summer that would amplify this offset. However, electrification of heating may lead to increased wintertime demand, which would lead to greater synchronization.

Coburn, Jacob↗

Climate System Response to External Forcings and Climate Change Projections in CCSM4

Results are presented from experiments performed with the Community Climate System Model, version 4 (CCSM4) for the Coupled Model Intercomparison Project phase 5 (CMIP5). These include multiple ensemble members of twentieth-century climate with anthropogenic and natural forcings as well as single-forcing runs, sensitivity experiments with sulfate aerosol forcing, twenty-first-century representative concentration pathway (RCP) mitigation scenarios, and extensions for those scenarios beyond 2100–2300. Equilibrium climate sensitivity of CCSM4 is 3.20°C, and the transient climate response is 1.73°C. Global surface temperatures averaged for the last 20 years of the twenty-first century compared to the 1986–2005 reference period for six-member ensembles from CCSM4 are +0.85°, +1.64°, +2.09°, and +3.53°C for RCP2.6, RCP4.5, RCP6.0, and RCP8.5, respectively. The ocean meridional overturning circulation (MOC) in the Atlantic, which weakens during the twentieth century in the model, nearly recovers to early twentieth-century values in RCP2.6, partially recovers in RCP4.5 and RCP6, and does not recover by 2100 in RCP8.5. Heat wave intensity is projected to increase almost everywhere in CCSM4 in a future warmer climate, with the magnitude of the increase proportional to the forcing. Precipitation intensity is also projected to increase, with dry days increasing in most subtropical areas. For future climate, there is almost no summer sea ice left in the Arctic in the high RCP8.5 scenario by 2100, but in the low RCP2.6 scenario there is substantial sea ice remaining in summer at the end of the century.

54 ENVIRONMENTAL SCIENCES↗

Uncertainties in Projecting Future Changes in Atmospheric Rivers and Their Impacts on Heavy Precipitation over Europe

This study investigates the North Atlantic atmospheric rivers (ARs) making landfall over western Europe in the present and future climate from the multi-model ensemble of the Coupled Model Intercomparison Project Phase 5 (CMIP5). Overall, CMIP5 captures the seasonal and spatial variations of historical landfalling AR days, with the large inter-model variability strongly correlated with the inter-model spread of historical jet position. Under RCP 8.5, AR frequency is projected to increase a few times by the end of this century. While thermodynamics plays a dominate role in the future increase of ARs, wind changes associated with the midlatitude jet shifts also significantly contribute to AR changes, resulting in dipole change patterns in all seasons. In the North Atlantic, the model projected jet shifts are strongly correlated with the simulated historical jet position. As models exhibit predominantly equatorward biases in the historical jet position, the large poleward jet shifts reduce AR days south of the historical mean jet position through the dynamical connections between the jet positions and AR days. Using the observed historical jet position as an emergent constraint, dynamical effects further increase AR days in the future above the large increases due to thermodynamical effects. In the future, both total and extreme precipitation induced by AR contribute more to the seasonal mean and extreme precipitation compared to present primarily because of the increase in AR frequency. While AR precipitation intensity generally increases more relative to the increase in integrated vapor transport, AR extreme precipitation intensity increases much less.

atmospheric rivers↗

Projected End-of-Century Changes in the South American Monsoon in the CESM Large Ensemble

Projected changes in the South American monsoon system by the end of the twenty-first century are analyzed using the Community Earth System Model Large Ensemble (CESM-LENS). The wet season is shorter in LENS when compared to observations, with the mean onset occurring 19 days later and the mean retreat date 21 days earlier in the season. Despite a precipitation bias, the seasonality of rainfall over South America is reproduced in LENS, as well as the main circulation features associated with the development of the South American monsoon. Both the onset and retreat of the wet season over South America are delayed in the future compared to current climate by 3 and 7 days, respectively, with a slightly longer wet season. Central and southeastern Brazil are projected to get wetter as a result of moisture convergence from the strengthening of the South Atlantic low-level jet and a weaker South Atlantic subtropical high. The Amazon is projected to get drier by the end of the century, negatively affecting rain forest productivity. During the wet season, an increase in the frequency and intensity of extreme precipitation events is found over most of South America, and especially over northeastern and southern Brazil and La Plata. Meanwhile, during the dry season an increase in the maximum number of consecutive dry days is found over northeastern Brazil and the northern Amazon.

54 ENVIRONMENTAL SCIENCES↗

The ECP ALPINE project: In situ and post hoc visualization infrastructure and analysis capabilities for exascale

A significant challenge on an exascale computer is the speed at which we compute results exceeds by many orders of magnitude the speed at which we save these results. Therefore the Exascale Computing Project (ECP) ALPINE project focuses on providing exascale-ready visualization solutions including in situ processing. In situ visualization and analysis runs as the simulation is run, on simulations results are they are generated avoiding the need to save entire simulations to storage for later analysis. The ALPINE project made post hoc visualization tools, ParaView and VisIt, exascale ready and developed in situ algorithms and infrastructures. The suite of ALPINE algorithms developed under ECP includes novel approaches to enable automated data analysis and visualization to focus on the most important aspects of the simulation. Many of the algorithms also provide data reduction benefits to meet the I/O challenges at exascale. ALPINE developed a new lightweight in situ infrastructure, Ascent.

97 MATHEMATICS AND COMPUTING↗

An Overview of the International Reactor Physics Experiment Evaluation Project

Interest in high-quality integral benchmark data is increasing as efforts to quantify and reduce calculational uncertainties associated with advanced modeling and simulation accelerate to meet the demands of next generation reactor and advanced fuel cycle concepts. Two Organization for Economic Cooperation and Development (OECD) Nuclear Energy Agency (NEA) activities, the International Criticality Safety Benchmark Evaluation Project (ICSBEP), initiated in 1992, and the International Reactor Physics Experiment Evaluation Project (IRPhEP), initiated in 2003, have been identifying existing integral experiment data, evaluating those data, and providing integral benchmark specifications for methods and data validation for nearly two decades. Data provided by those two projects will be of use to the international reactor physics, criticality safety, and nuclear data communities for future decades. An overview of the IRPhEP and a brief update of the ICSBEP are provided in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗