Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power optimizer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Recovery Act: High-Efficiency, Wideband Three-Phase Rectifiers and Adaptive Rectifier Management for Telecomm Central Office and Large Data Center Applications (Final Technical Report)

Lineage Power and Verizon teamed up to address a DOE funding opportunity focused on improving the power conversion chain in telecommunications facilities and data centers. The project had three significant elements: the design and development of high efficiency and high power three-phase rectifiers by Lineage Power, design and development of software to optimize overall plant energy efficiency by Lineage Power, and a field trial in active Verizon telecommunications facilities where energy consumption was measured before and after efficiency upgrades.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Convex Capital Cost Optimization: A Rwandan Case

Most power grids were designed and constructed for a centralized generation system, under the principle of large plants transmitting power over long distances. For grids with increasingly high renewable generators, the intermittent nature of renewable energy production can cause large seasonal swings in the supply [1]. To account for these changes, developing countries often use centralized diesel generation to satisfy energy peak demand each day, as diesel generation is relatively easy to ramp, is not dependent on weather, and has a fairly low fixed cost to add capacity. However, in this study we want to provide a tool to question whether diesel is the most economic way to shave peak demand in some developing countries.

13 HYDRO ENERGY↗

Optimized design of reactor cores for continuous operation of Belgian nuclear power plants

Two Belgian nuclear power plants, owned and operated by Electrabel, were initially planned to be phased out in 2015, reaching their maximum life time of operation by the initial design. The fuel management of those two units has been subsequently designed by Tractebel to make the best use of the energy in the fuel assemblies either in the core or in the storage pool and to minimize the size of the fresh reloads in the terminating cycles. However, for ensuring energy security in Belgium, the Government decided in the same year to extend the life time of operation of the two units for 10 years, which raised the need to resume their continuous operation, in the opposite direction of the core contents and with a significant break in the usual sequence of cycle reloads. All this required adaptation of the tools and process for optimized reactor core design, in order to ensure the continuous and flexible operation of those units. The Tractebel LWRWIMS-PANTHER (LWP) core physics package is based on the 3-dimensional (3D) neutronic code PANTHER and the lattice code LWRWIMS for the generation of the assembly nuclear data. Both have been qualified by Tractebel for the Belgian Units to perform a complete range of PWR reactor calculations for fuel management design safety parameters assessment, transient analysis and operational support. In-core fuel management involves calculating core reactivity, power distribution and isotopic inventory for subsequent fuel cycles of a nuclear power plant in order to maintain adequate safety margins and operating lifetime for each core loading. This paper presents Tractebel's improved core design tools and process, the approach to optimize the reactor core design, and the applications to the 2 successive but opposite design requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Blade planform design optimization to enhance turbine wake control

Abstract This study considers optimizing the planform of wind turbine blades to ultimately enhance wind plant controls, namely, wake steering strategies. Adjoint‐enabled unsteady actuator line simulations are carried out to obtain gradients for optimization of several different performance objectives with respect to blade chord length at 10 locations along blade span. We demonstrate different blade design optimizations that can maximize time‐averaged lateral wake deflection, entrainment of kinetic energy, or total power of multiple turbines. Our optimized designs can produce a 4+% increase in wake deflection, a 4× increase in vertical kinetic energy entrainment, or a 3.6% increase in power when compared with the baseline case. While lateral wake deflection is only modestly sensitive to chord changes, we find that increasing the outboard chord length can dramatically increase kinetic energy entrainment, resulting in faster wake recovery and gains in net power. While this work develops only a few case studies emphasizing relative performance improvements and general trends, these results show the promise of a framework that combines mid‐fidelity computation with adjoint‐based optimization for control and design problems.

WIND ENERGY↗

Analytical Analysis of Ac and Dc Side Harmonics of Three-level Active Neutral Point Clamped Inverter with Space Vector Modulation

This paper presents a comprehensive analytical analysis of the ac and dc side harmonics of the three-level active neutral point clamped (ANPC) inverter with space vector modulation (SVM) scheme. An analytical model to calculate the harmonics of a three-level converter with SVM is developed. The ac side output voltage harmonics and dc side current harmonics characteristics are calculated and analyzed. With the developed models, the impact of interleaving on both sides harmonics are studied which considers the modulation index, interleaving angle, and power factor. The analysis provides guideline for interleaving angle optimization to reduce the ac side power filter and dc side dc-link capacitor. The relationship between electromagnetic interference (EMI) filter corner frequency and switching frequency is also analytically derived which provides guideline for switching frequency and EMI filter design optimization. Two paralleled three-level ANPC inverters are constructed and experimental results are presented to verify the analytical analysis.

Chen, Ruirui↗

Fourier Analysis-Based Evolutionary Multi-Objective Multiphysics Optimization of Liquid-Cooled Heat Sinks

Optimal heat dissipation in power modules can significantly increase their power density. Removing the generated heat is critical for capturing the benefits of advanced semiconductor materials and improving the reliability of the device operation. This article proposes a design optimization method for liquid-cooled heat sinks that use a Fourier analysis-based tool and an evolutionary optimization algorithm to optimize the heat sink geometry for specified objectives. The optimized heat sink geometry is then compared with state-of-the-art solutions in literature based on finite element analysis of different designs. The proposed methodology can develop complex geometries that outperform the conventional heat sink geometries.

Sahu, Raj↗

High-potential Working Fluids for Next Generation Binary Cycle Geothermal Power Plants

A thermo-economic model has been built and validated for prediction of project economics of Enhanced Geothermal Projects. The thermo-economic model calculates and iteratively optimizes the LCOE (levelized cost of electricity) for a prospective EGS (Enhanced Geothermal) site. It takes into account the local subsurface temperature gradient, the cost of drilling and reservoir creation, stimulation and power plant configuration. It calculates and optimizes the power plant configuration vs. well depth. Thus outputs from the model include optimal well depth and power plant configuration for the lowest LCOE.

15 GEOTHERMAL ENERGY↗

Literature Survey on Operational Voltage Control and Reactive Power Management on Transmission and Sub-Transmission Networks

Voltage and reactive power system control is generally performed following usual patterns of loads, based on off-line studies for daily and seasonal operations. This practice is currently challenged by the inclusion of distributed renewable generation, such as solar. There has been focus on resolving this problem at the distribution level; however, the transmission and sub-transmission levels have received less attention. This paper provides a literature review of proposed methods and solution approaches to coordinate and optimize voltage control and reactive power management, with an emphasis on applications at transmission and sub-transmission level. The conclusion drawn from the survey is that additional research is needed in the areas of optimizing switch shunt actions and coordinating all available resources to deal with uncertain patterns from increasing distributed renewable generation in the operational time frame. These topics are not deeply explored in the literature.

capacitors↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Semantic Information Modeling for Emerging Applications in Smart Grid

Smart Grid modernizes power grid by integrating digital and information technologies. Millions of smart meters, intelligent appliances and communication infrastructures are under deployment allowing advanced IT applications to be developed to secure and manage power grid operations. Demand response (DR) is one such emerging application to optimize electricity demand by curtailing/shifting power load when peak load occurs. Existing DR approaches are mostly based on static plans such as pricing policies and load shedding schedules. However, improvements to power management applications rely on data emanating from existing and new information sources with the growth of Smart Grid information space. In particular, dynamic DR algorithms depend on information from smart meters that report interval-based power consumption measurement, HVAC systems that monitor buildings heat and humidity, and even weather forecast services. In order for emerging Smart Grid applications to take advantage of the diverse data influx, extensible information integration is required. In this paper, we develop an integrated Smart Grid information model using Semantic Web techniques and present case studies of using semantic information for dynamic DR. We show the semantic model facilitates information integration and knowledge representation for developing the next generation Smart Grid applications.

complex event processing↗

Thermal power plant upgrade via a rotating detonation combustor and retrofitted turbine with optimized endwalls

Over the past decade, pressure gain combustion research has promised over 10 percentage-points of increase in power plant thermal efficiency. Alas, to realize such potential gain, one must effectively couple the turbine with the detonation combustor, whose exhaust conditions differ substantially from current state of the art gas turbines. This paper presents a modeling approach that enables a superior thermodynamic cycle with a rotating detonation combustor and a retrofitted gas turbine by including a diffuser downstream of the combustor and by contouring the turbine endwall, while preserving the airfoil geometry. We propose a multi-step optimization strategy, parametrizing the endwall geometry with a few control points, without altering the airfoil geometry, and with the stage turbine efficiency as objective function. In a first step the turbine performance is assessed with steady inlet conditions by solving the steady three-dimensional Reynolds-Averaged Navier-Stokes equations. In a second step, the inlet conditions are unsteady, as predicted from a detonation combustor and a diffuser, and three-dimensional full unsteady simulations are performed with an unsteady Reynolds-Averaged Navier-Stokes solver. By altering the vane endwall, the steady optimization yielded an efficiency increase of 12% relative to the baseline, while the unsteady optimization resulted in 21% increase compared to the datum turbine. Finally, a full engine analysis demonstrated the superiority of pressure gain combustion which included a realistic thermodynamic cycle of the combustor, the diffuser and the optimized turbine components.

42 ENGINEERING↗

Aerothermal Shape Optimization of Actively-Cooled Battery Packs Using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

heat transfer↗

Aerothermal Shape Optimization of Actively-Cooled Battery Packs using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

thermal management↗

Three-dimensional structure of wind turbine wakes as measured by scanning lidar

Abstract. The lower wind speeds and increased turbulence that are characteristic of turbine wakes have considerable consequences on large wind farms: turbines located downwind generate less power and experience increased turbulent loads. The structures of wakes and their downwind impacts are sensitive to wind speed and atmospheric variability. Wake characterization can provide important insights for turbine layout optimization in view of decreasing the cost of wind energy. The CWEX-13 field campaign, which took place between June and September 2013 in a wind farm in Iowa, was designed to explore the interaction of multiple wakes in a range of atmospheric stability conditions. Based on lidar wind measurements, we extend, present, and apply a quantitative algorithm to assess wake parameters such as the velocity deficits, the size of the wake boundaries, and the location of the wake centerlines. We focus on wakes from a row of four turbines at the leading edge of the wind farm to explore variations between wakes from the edge of the row (outer wakes) and those from turbines in the center of the row (inner wakes). Using multiple horizontal scans at different elevations, a three-dimensional structure of wakes from the row of turbines can be created. Wakes erode very quickly during unstable conditions and can in fact be detected primarily in stable conditions in the conditions measured here. During stable conditions, important differences emerge between the wakes of inner turbines and the wakes of outer turbines. Further, the strong wind veer associated with stable conditions results in a stretching of the wake structures, and this stretching manifests differently for inner and outer wakes. These insights can be incorporated into low-order wake models for wind farm layout optimization or for wind power forecasting.

17 WIND ENERGY↗

Optimal Heliostat Assignment Strategy for Multiple-Receiver Systems

Next-generation concentrating solar power concepts currently being developed under the U.S. Department of Energy's Gen3 program include several novel heliostat field and receiver arrangements. Among these concepts are solar fields utilizing multiple receivers or several distinct receiver flux control zones, and each of which has particular power or peak flux constraints. In this paper, we present a linear program that identifies optimal heliostat-to-receiver assignment strategies for multi-receiver or multi-zone solar fields based on detailed calculations made by an optics modeling package. Two distinct problems are addressed: namely, (1) a design problem that chooses the optimal set of heliostats to include in a final layout given receiver constraints and performance, and (2) an operations problem that assigns existing heliostats to a receiver, maximizing field power output while maintaining receiver power constraints. The optimization methodology is integrated into the concentrating solar power tower modeling package SolarPILOTTM, and results are presented showing that heliostat assignment strategies can impact both initial heliostat field layout characteristics and the cost of thermal energy produced by the field. The methodology succeeds in maintaining power requirements but at the expense of producing different flux profiles on each receiver surface. Consequently, the paper also discusses additional measures that are applied to ensure that desirable flux distribution properties are maintained, reducing local flux mean-absolute-deviation values from a baseline of 17% or greater to less than 5% compared to a desired reference flux profile.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Testing and Development of a Percussive Augmenter for Rotary Drills

Hammering drills are effective in fracturing the drilled medium while rotary drills remove cuttings. The combination provides a highly effective penetration mechanism. Piezoelectric actuators were integrated into an adapter to produce ultrasonic percussion; augmenting rotary drilling. The drill is capable of operating at low power, low applied force and, with proper tuning, low noise. These characteristics are of great interest for future NASA missions and the construction/remodeling industry. The developed augmenter connects a commercially available drill and bit and was tested to demonstrate its capability. Input power to the drill was read using a multimeter and the augmenter received a separate input voltage. The drive frequency of the piezoelectric actuator was controlled by a hill climb algorithm that optimizes and records average power usage to operate the drill at resonating frequency. Testing the rotary drill and augmenter across a range of combinations with total power constant at 160 Watts has shown results in concrete and limestone samples that are as good as or better than the commercial drill. The drill rate was increased 1.5 to over 10 times when compared to rotation alone.

rotary-hammering↗

Grid Optimization Competition Challenge 3 Problem Formulation

This report contains the problem formulation for the Grid Optimization (GO) Competition Challenge 3. The Grid Optimization Competition is run by a team of researchers from a number of organizations, including the sponsor Advanced Research Projects Agency - Energy (ARPA-E), lead organization Pacific Northwest National Laboratory (PNNL), and technical contributors from Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), Texas A&M University (TAMU), Georgia Institute of Technology (GT), University of Wisconsin (UW), and others. The GO Competition poses challenge problems in the field of power grid management, invites entrants to develop solvers for these problems, invokes the solvers on a set of problem instances using common hardware, ranks the solvers according to their performance, and awards prizes according to the rankings. The overall goal of the GO Competition is to spur innovative research on high impact and computationally challenging problems in power grid management from initial development through commercial deployment. Complete information about the GO Competition can be found online at [2]. The webpage covers previous Challenges, rules, timeline, registration information, data formats, scoring methods, computational platform information, information on supported solvers and languages, sponsor information, frequently asked questions, administrator contact information, publicly available problem instances, computer code for reading and evaluating problem and solution data, a sandbox for testing solvers, and a solver submission interface, results, and publications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experiences Evaluating Functionality and Performance of IBM POWER8+ Systems

In preparation for Summit, Oak Ridge National Laboratory’s next generation supercomputer, two IBM Power-based systems were deployed in late 2016 at the Oak Ridge Leadership Computing Facility (OLCF). This paper presents a detailed description of the acceptance of the first IBM Power-based early access systems installed at the OLCF. The two systems, Summitdev and Tundra, contain IBM POWER8+ processors with NVIDIA Pascal GPUs and were acquired to provide researchers with a platform to optimize codes for the Power architecture. In addition, this paper presents early functional and performance results obtained on Summitdev with the latest software stack available.

Vergara Larrea, Veronica G.↗