Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Late cataractogenesis caused by particulate radiations and photons in long-lived mammalian species

Radiation cataractogenesis induced by small acute doses of particulate radiations and photons in the New Zealand white rabbit (Oryctolagus cuniculus), the beagle dog (Canis familiaris) and the rhesus monkey (Macaca mulatta) is discussed in the context of the use of animal models to assess the radiation hazards faced by humans during lengthy sojourns in deep space. Attention is paid to (1) the importance of lifespan studies with long-lived species - the above animals have median lifespans in captivity of 5-7, 13-14 and 25 years, respectively; and (2) the magnitudes of possible dose thresholds for cataractogenesis from sparsely ionizing radiations and the modifications of those thresholds by the late degenerative phase of the phenomenon.

Lett, J. T.↗

Enhanced resolution particle size distributions by multiple angle photon correlation spectroscopy

Photon correlation spectroscopy (PCS) has become a method of choice for measuring submicrometer particles. It is capable of rapid, accurate measurements of mean particle size. Since the measurements are nonperturbing, it is ideal for monitoring systems undergoing dynamic changes. Despite its widespread acceptance, the information content of PCS measurements for particle size distributions is low and provides limited resolution. A method is presented whereby PCS measurements made at several scattering angles plus the angular distribution of light scattered from the particles are combined in a single simultaneous analysis to effect an enhanced resolution particle size distribution. The efficacy of the method is assessed by recovering size distributions from computer simulated data and by comparisons of conventional PCS measurements of polystyrene spheres with those made by the new method.

Bott, Steven E.↗

Photon sputtering of H2O ices: A preliminary report

A preliminary measurement of the total yields of ejected ions and electrons from H2O ices has been carried out using the He I 584 A resonance line as the incident photon beam. The H2O ices were prepared at 77 K in an ultrahigh vacuum system. The total yield of the ejected ion species and electrons was determined to be 8.8x10(exp -5) and 4.2x10(exp -4), respectively.

Wu, C. Y. Robert↗

An airborne compatible photofragmentation two-photon laser-induced fluorescence instrument for measuring background tropospheric levels of NO, NO(x), and NO2

The operating principle, design, and performance of a two-photon LIF (TP-LIF) sensor for simultaneous measurements of NO, NO(x) (NO + NO2), and NO2 are described. In this instrument, NO is first measured by direct spectroscopic TP-LIF detection; NO2 is converted to NO by photofragmentation using an XeF excimer laser operating at 353 nm; and the resulting NO is then detected quantitatively by TP-LIF. The detection limits of the instrument are found to be 3.5 parts per trillion by volume (pptv) of NO and 10 pptv for NO2, with integration times of 2 and 6 min, respectively. The in-flight performance of the instrument was evaluated during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 program in summer 1986, as reported by Gregory et al. (1990).

Sandholm, S. T.↗

Design and testing of an active quenching circuit for an avalanche photodiode photon detector

The photon-detection capabilities of avalanche photodiodes (APDs) operating above their theoretical breakdown voltages are described, with particular attention given to the needs and methods of quenching an avalanche once breakdown has occurred. A brief background on the motives of and previous work with this mode of operation is presented. Finally, a description of the design and testing of an active quenching circuit is given. Although the active quenching circuit did not perform as expected, knowledge was gained as to the signal amplitudes necessary for quenching and the need for a better model for the above-breakdown circuit characteristics of the Geiger-mode APD.

Arbel, D.↗

A lidar equipped with photon counter for measuring stratospheric aerosols

A large lidar system was developed at the Anhui Institute of Optics and Fine Mechanics. It is composed of a high power frequency doubled Nd:YAG laser (120 mJ at 532 nm, 1 mrad), a 651 mm diameter receiving telescope, and a 64 channel photon counter. The lidar observations are controlled by an IBM PC/AT computer. One of the projects is to use the lidar system to make regular observations of stratospheric aerosols. Profiles of scattering ratio have been obtained since November 1989. Meanwhile, an Xe-Cl laser (308 nm wavelength) was assembled to allow the lidar to make measurements of vertical ozone distributions.

Zhou, Jun↗

Photon-assisted resonant tunneling through variably spaced superlattice energy filters

The observation of photon-assisted resonant tunneling in a multiple quantum well structure composed of doped quantum wells separated by variably space superlattice energy filters is reported. Electrons confined in the quantum wells are excited to the second quantized state by intersubband absorption of incident infrared radiation and are subsequently emitted through the filters under appropriate bias conditions. This is manifested by a distinct peak, with an associated negative differential photoconductance, in the photocurrent versus bias voltage characteristic at low temperatures.

Larsson, A.↗

Imaging hydrogen flames by two-photon, laser-induced fluorescence

A nonintrusive multicomponent imaging system is developed which can image hydrogen, hot oxygen, and air simultaneously. An Ar-F excimer laser is injection-locked to cover the Q1 two-photon transition in molecular hydrogen which allows the observation of both hot oxygen and cold hydrogen. Rayleigh scattering from the water molecules occurs at the same frequency as the illuminating laser allowing analysis of the air density. Images of ignited and nonignited hydrogen jets are recorded with a high-sensitivity gated video camera. The images permit the analysis of turbulent hydrogen-core jet, the combustion zone, and the surrounding air, and two-dimensional spatial correlations can be made to study the turbulent structure and couplings between different regions of the flow field. The method is of interest to the study of practical combustion systems which employ hydrogen-air diffusion flames.

Miles, R.↗

Photon polarization version of the GHz-Mermin Gedanken

We have defined a photon polarization analog of the Greenberger, Horne, and Zeilinger (GHZ) experiment that was initially proposed for spin-1/2 quanta. Analogs of the ket states and Pauli spin matrix operators are presented.

Kiess, Thomas E.↗

Ideal photon number amplifier and duplicator

The photon number-amplification and number-duplication mechanism are analyzed in the ideal case. The search for unitary evolutions leads to consider also a number-deamplification mechanism, the symmetry between amplification and deamplification being broken by the integer-value nature of the number operator. Both transformations, amplification and duplication, need an auxiliary field which, in the case of amplification, turns out to be amplified in the inverse way. Input-output energy conservation is accounted for using a classical pump or through frequency-conversion of the fields. Ignoring one of the fields is equivalent to considering the amplifier as an open system involving entropy production. The Hamiltonians of the ideal devices are given and compared with those of realistic systems.

Dariano, G. M.↗

Fundamental and practical limitations of FUV/EUV photon-counting image detectors

In EUV and FUV space-astronomy applications, the best contemporary detector designs are based on the use of microchannel plates due to their ability to deliver photon-counting performance with high efficiency. The major unresolved issue is the choice of position-readout system for the individual photoevents. Electrical event-readout systems are divided into two classes: the discrete wire anodes that perform coordinate digitization by wire-group selection, and the continuous centroid-position encoders for which coordinates are digitized in the associated electronics. The centroid-position encoder techniques are discussed in terms of how they overcome the four chief limitations of the discrete-wire readouts - their limited format size, their flat focal surface, their fundamental hex-channel vs squared-pixel moire pattern, and their image undersampling. With these limitations overcome, microchannel based image systems can deliver the performance demanded by the forthcoming generation of applications in space astronomy.

Lampton, M.↗

Photon number squeezed states in semiconductor lasers

Electromagnetic fields, with the noise on one quadrature component reduced to below the quantum mechanical zero-point fluctuation level and the noise on the other quadrature component enhanced to above it, are currently of great interest in quantum optics because of their potential applications to various precision measurements. Such squeezed states of light are usually produced by imposing nonlinear unitary evolution on coherent (or vacuum) states. On the other hand, squeezed states with reduced photon number noise and enhanced phase noise are generated directly by a constant current-driven semiconductor laser. This is the simplest scheme for the generation of nonclassical light, and so far it has yielded the largest quantum noise reduction. The mutual coupling between a lasing junction and an external electrical circuit provides opportunities for exploring the macroscopic and microscopic quantum effects in open systems.

Yamamoto, Yoshihisa↗

Interaction between photons and leaf canopies

The physics of neutral particle interaction for photons traveling in media consisting of finite-dimensional scattering centers that cross-shade mutually is investigated. A leaf canopy is a typical example of such media. The leaf canopy is idealized as a binary medium consisting of randomly distributed gaps (voids) and regions with phytoelements (turbid phytomedium). In this approach, the leaf canopy is represented by a combination of all possible open oriented spheres. The mathematical approach for characterizing the structure of the host medium is considered. The extinction coefficient at any phase-space location in a leaf canopy is the product of the extinction coefficient in the turbid phytomedium and the probability of absence gaps at that location. Using a similar approach, an expression for the differential scattering coefficient is derived.

Knyazikhin, Yuri V.↗

High resolution vidicon-based readout system for photon-counting streak camera applications

The design, implementation, and evaluation of a high-resolution vidicon-based reconfigurable imaging system for integration into a photon-counting streak camera that can be readily coupled to a standard interface and computer have been achieved. Experimental results are reported which demonstrate that the design goals are met, providing the capability to measure differential time to better than 3 picosecond accuracy. Augmented by real-time calibration, the accuracy, linearity, noise levels, and stability of the system are adequate to support dual wavelength laser ranging.

Varghese, Thomas K.↗

Detection of TeV photons from the active galaxy Markarian 421

The detection of TeV energy photons from the giant elliptical galaxy Markarian 421 using the Whipple Observatory gamma-ray telescope is reported. The signal has a statistical significance of 6 sigma above background and the flux above 0.5 TeV is 0.3 of that from the Crab Nebula. The source location agrees with the position of Mk 421 within the angular uncertainty of the Whipple instrument.

Punch, M.↗

Proportional counters as low energy photon detectors

We investigated the response of an argon-methane proportional counter to monochromatic X-rays in the range 99 to 277 eV. The apparent nonlinearities in mean pulse height as a function of photon energy and the detailed shape of the pulse height distribution for each energy can be predicted quite precisely using the extensive atomic data available for argon. Based on this understanding, we propose a semi-empirical system for using a limited amount of calibration data to predict the full response of counters employing less well-characterized gases. Such accurate models of proportional counters are required to maximize the spectral information that can be derived from observed pulse height distributions.

Jahoda, Keith↗

Real-time quality assurance testing using photonic techniques: Application to iodine water system

A feasibility study of the use of inspection systems incorporating photonic sensors and multivariate analyses to provide an instrumentation system that in real-time assures quality and that the system in control has been conducted. A system is in control when the near future of the product quality is predictable. Off-line chemical analyses can be used for a chemical process when slow kinetics allows time to take a sample to the laboratory and the system provides a recovery mechanism that returns the system to statistical control without intervention of the operator. The objective for this study has been the implementation of do-it-right-the-first-time and just-in-time philosophies. The Environment Control and Life Support Systems (ECLSS) water reclamation system that adds iodine for biocidal control is an ideal candidate for the study and implementation of do-it-right-the-first-time technologies.

Arendale, W. F.↗