Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

WE-D-BRF-01: FEATURED PRESENTATION - Investigating Particle Track Structures Using Fluorescent Nuclear Track Detectors and Monte Carlo Simulations

Purpose: To report on the efforts funded by the AAPM seed funding grant to develop the basis for fluorescent nuclear track detector (FNTD) based radiobiological experiments in combination with dedicated Monte Carlo simulations (MCS) on the nanometer scale. Methods: Two confocal microscopes were utilized in this study. Two FNTD samples were used to find the optimal microscope settings, one FNTD irradiated with 11.1 MeV/u Gold ions and one irradiated with 428.77 MeV/u Carbon ions. The first sample provided a brightly luminescent central track while the latter is used to test the capabilities to observe secondary electrons. MCS were performed using TOPAS beta9 version, layered on top of Geant4.9.6p02. Two sets of simulations were performed, one with the Geant4-DNA physics list and approximating the FNTDs by water, a second set using the Penelope physics list in a water-approximated FNTD and a aluminum-oxide FNTD. Results: Within the first half of the funding period, we have successfully established readout capabilities of FNTDs at our institute. Due to technical limitations, our microscope setup is significantly different from the approach implemented at the DKFZ, Germany. However, we can clearly reconstruct Carbon tracks in 3D with electron track resolution of 200 nm. A second microscope with superior readout capabilities will be tested in the second half of the funding period, we expect an improvement in signal to background ratio with the same the resolution.We have successfully simulated tracks in FNTDs. The more accurate Geant4-DNA track simulations can be used to reconstruct the track energy from the size and brightness of the observed tracks. Conclusion: We have achieved the goals set in the seed funding proposal: the setup of FNTD readout and simulation capabilities. We will work on improving the readout resolution to validate our MCS track structures down to the nanometer scales.

60 APPLIED LIFE SCIENCES↗

Hybrid Multiscale Finite Volume Method for Advection-Diffusion Equations Subject to Heterogeneous Reactive Boundary Conditions

We present a hybrid scheme for the coupling of macro and microscale continuum models for reactive contaminant transport in fractured and porous media. The transport model considered is the advection-dispersion equation, subject to linear heterogeneous reactive boundary conditions. The Multiscale Finite Volume method (MsFV) is employed to define an approximation to the microscale concentration field defined in terms of macroscopic or \emph{global} degrees of freedom, together with local interpolator and corrector functions capturing microscopic spatial variability. The macroscopic mass balance relations for the MsFV global degrees of freedom are coupled with the macroscopic model, resulting in a global problem for the simultaneous time-stepping of all macroscopic degrees of freedom throughout the domain. In order to perform the hybrid coupling, the micro and macroscale models are applied over overlapping subdomains of the simulation domain, with the overlap denoted as the handshake subdomain $\Omega^{hs}$, over which continuity of concentration and transport fluxes between models is enforced. Continuity of concentration is enforced by posing a restriction relation between models over $\Omega^{hs}$. Continuity of fluxes is enforced by prolongating the macroscopic model fluxes across the boundary of $\Omega^{hs}$ to microscopic resolution. The microscopic interpolator and corrector functions are solutions to local microscopic advection-diffusion problems decoupled from the global degrees of freedom and from each other by virtue of the MsFV decoupling ansatz. The error introduced by the decoupling ansatz is reduced iteratively by the preconditioned GMRES algorithm, with the hybrid MsFV operator serving as the preconditioner.

Barajas-Solano, David A.↗

Ab Initio Calculations Of Light-Ion Reactions

The exact treatment of nuclei starting from the constituent nucleons and the fundamental interactions among them has been a long-standing goal in nuclear physics. In addition to the complex nature of nuclear forces, one faces the quantum-mechanical many-nucleon problem governed by an interplay between bound and continuum states. In recent years, significant progress has been made in ab initio nuclear structure and reaction calculations based on input from QCD employing Hamiltonians constructed within chiral effective field theory. In this contribution, we present one of such promising techniques capable of describing simultaneously both bound and scattering states in light nuclei. By combining the resonating-group method (RGM) with the ab initio no-core shell model (NCSM), we complement a microscopic cluster approach with the use of realistic interactions and a microscopic and consistent description of the clusters. We discuss applications to light nuclei scattering, radiative capture and fusion reactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Switchable resolution in soft x-ray tomography of single cells

The diversity of living cells, in both size and internal complexity, calls for imaging methods with adaptable spatial resolution. Soft x-ray tomography (SXT) is a three-dimensional imaging technique ideally suited to visualizing and quantifying the internal organization of single cells of varying sizes in a near-native state. The achievable resolution of the soft x-ray microscope is largely determined by the objective lens, but switching between objectives is extremely time-consuming and typically undertaken only during microscope maintenance procedures. Since the resolution of the optic is inversely proportional to the depth of focus, an optic capable of imaging the thickest cells is routinely selected. This unnecessarily limits the achievable resolution in smaller cells and eliminates the ability to obtain high-resolution images of regions of interest in larger cells. Here, we describe developments to overcome this shortfall and allow selection of microscope optics best suited to the specimen characteristics and data requirements. We demonstrate that switchable objective capability advances the flexibility of SXT to enable imaging cells ranging in size from bacteria to yeast and mammalian cells without physically modifying the microscope, and we demonstrate the use of this technology to image the same specimen with both optics.

59 BASIC BIOLOGICAL SCIENCES↗

Future of Electron Scattering and Diffraction

The ability to correlate the atomic- and nanoscale-structure of condensed matter with physical properties (e.g., mechanical, electrical, catalytic, and optical) and functionality forms the core of many disciplines. Directing and controlling materials at the quantum-, atomic-, and molecular-levels creates enormous challenges and opportunities across a wide spectrum of critical technologies, including those involving the generation and use of energy. The workshop identified next generation electron scattering and diffraction instruments that are uniquely positioned to address these grand challenges. The workshop participants identified four key areas where the next generation of such instrumentation would have major impact: A – Multidimensional Visualization of Real Materials B – Atomic-scale Molecular Processes C – Photonic Control of Emergence in Quantum Materials D – Evolving Interfaces, Nucleation, and Mass Transport Real materials are comprised of complex three-dimensional arrangements of atoms and defects that directly determine their potential for energy applications. Understanding real materials requires new capabilities for three-dimensional atomic scale tomography and spectroscopy of atomic and electronic structures with unprecedented sensitivity, and with simultaneous spatial and energy resolution. Many molecules are able to selectively and efficiently convert sunlight into other forms of energy, like heat and electric current, or store it in altered chemical bonds. Understanding and controlling such process at the atomic scale require unprecedented time resolution. One of the grand challenges in condensed matter physics is to understand, and ultimately control, emergent phenomena in novel quantum materials that necessitate developing a new generation of instruments that probe the interplay among spin, charge, orbital, and lattice degrees of freedom with intrinsic time- and length-scale resolutions. Molecules and soft matter require imaging and spectroscopy with high spatial resolution without damaging their structure. The strong interaction of electrons with matter allows high-energy electron pulses to gather structural information before a sample is damaged. Electron ScatteringImaging, diffraction, and spectroscopy are the fundamental capabilities of electron-scattering instruments. The DOE BES-funded TEAM (Transmission Electron Aberration-corrected Microscope) project achieved unprecedented sub-atomic spatial resolution in imaging through aberration-corrected transmission electron microscopy. To further advance electron scattering techniques that directly enable groundbreaking science, instrumentation must advance beyond traditional two-dimensional imaging. Advances in temporal resolution, recording the full phase and energy spaces, and improved spatial resolution constitute a new frontier in electron microscopy, and will directly address the BES Grand Challenges, such as to “control the emergent properties that arise from the complex correlations of atomic and electronic constituents” and the “hidden states” “very far away from equilibrium”. Ultrafast methods, such as the pump-probe approach, enable pathways toward understanding, and ultimately controlling, the chemical dynamics of molecular systems and the evolution of complexity in mesoscale and nanoscale systems. Central to understanding how to synthesize and exploit functional materials is having the ability to apply external stimuli (such as heat, light, a reactive flux, and an electrical bias) and to observe the resulting dynamic process in situ and in operando, and under the appropriate environment (e.g., not limited to UHV conditions). To enable revolutionary advances in electron scattering and science, the participants of the workshop recommended three major new instrumental developments: A. Atomic-Resolution Multi-Dimensional Transmission Electron Microscope: This instrument would provide quantitative information over the entire real space, momentum space, and energy space for visualizing dopants, interstitials, and light elements; for imaging localized vibrational modes and the motion of charged particles and vacancies; for correlating lattice, spin, orbital, and charge; and for determining the structure and molecular chemistry of organic and soft matter. The instrument will be uniquely suited to answer fundamental questions in condensed matter physics that require understanding the physical and electronic structure at the atomic scale. Key developments include stable cryogenic capabilities that will allow access to emergent electronic phases, as well as hard/soft interfaces and radiation- sensitive materials. B. Ultrafast Electron Diffraction and Microscopy Instrument: This instrument would be capable of nano-diffraction with 10 fs temporal resolution in stroboscopic mode, and better than 100 fs temporal resolution in single shot mode. The instrument would also achieve single- shot real-space imaging with a spatial/temporal resolution of 10 nm/10 ps, representing a thousand fold improvement over current microscopes. Such a capability would be complementary to x-ray free electron lasers due to the difference in the nature of electron and x-ray scattering, enabling space-time mapping of lattice vibrations and energy transport, facilitating the understanding of molecular dynamics of chemical reactions, the photonic control of emergence in quantum materials, and the dynamics of mesoscopic materials. C. Lab-In-Gap Dynamic Microscope: This instrument would enable quantitative measurements of materials structure, composition, and bonding evolution in technologically relevant environments, including liquids, gases and plasmas, thereby assuring the understanding of structure function relationship at the atomic scale with up to nanosecond temporal resolution. This instrument would employ a versatile, modular sample stage and holder geometry to allow the multi-modal (e.g., optical, thermal, mechanical, electrical, and electrochemical) probing of materials’ functionality in situ and in operando. The electron optics encompasses a pole piece that can accommodate the new stage, differential pumping, detectors, aberration correctors, and other electron optical elements for measurement of materials dynamics. To realize the proposed instruments in a timely fashion, BES should aggressively support research and development of complementary and enabling instruments, including new electron sources, advanced electron optics, new tunable specimen pumps and sample stages, and new detectors. The proposed instruments would have transformative impact on physics, chemistry, materials science, engineering

43 PARTICLE ACCELERATORS↗

3013 Inner Container Closure Weld Region (ICCWR) Characterization by Wide Area 3D Measurement System (WAMS) Analysis (FY21 Progress Report)

As part of the 3013 Surveillance Program, through-wall penetration from stress corrosion cracking (SCC) of the 3013 inner containers has been identified as the most credible condition for failure withing the 50- years lifetime. Chlorides contained in Pu-bearing material, together with intra-canister humidity levels, metallurgical conditions, and internal stresses have been found to produce corrosion in the Inner Container Closure Weld Region (ICCWR) of the 3013 canister system. A Laser Confocal Microscope (LCM) is used as part of the 3013 Surveillance Program protocol to identify the prevalence of corrosion and corrosionrelated cracking in the ICCWR2. With the LCM, a close visual examination is made of the ICCWR surface along with measurements of corrosion-related features. LCM inspections produce immense amounts of image data that is time intensive to analyze. There is also a 9-year backlog of images, with approximately 49 canisters that must be evaluated. To expedite data analysis and reduce the amount of generated data, a Wide Area 3D Measurement System (WAMS) microscope has been added to the examination protocol. Although WAMS is a lower resolution microscope, small features of interest can be still identified. The advantage of collecting data for the full circumference using the WAMS is that it can take about 1/16 of the time needed with the LCM. Both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS is an efficient system for screening and identification of corrosion features while the LCM can be utilized to obtain higher resolution images areas identified by the WAMS. This report explains and justifies the data collection methods used with the WAMS. It includes a summary of the data generated by WAMS in FY21. The goals set for data collection in FY21 were met. A total of twenty-two DE’s were imaged, and analysis was carried out on eleven samples. The analyzed samples showed large numbers of potential cracks and pits distributed throughout the surfaces. Lastly, to explain the advantages of the WAMS, its capabilities were compared to those of a simpler microscope. Micrographs of the samples imaged in FY21 and those analyzed are included in the appendices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advancements in Multiphysics Microdepletion Analysis of an eVinci TM -like Microreactor Leveraging OpenMC-CRAB Workflow

Nuclear microreactors (MRs) are a class of nuclear reactor technology, characterized by reduced dimensions, modular design, and reduced power output in contrast to conventional Light Water Reactors (LWRs). MRs are proposed for supplying electricity and eventual process heat to remote locations, such as military installations and disaster-affected areas. Current research work sponsored by the US Department of Energy Microreactor Program (MRP) is devoted to the development of novel modeling and simulation tools to better support MR vendors and regulatory bodies. Notably, the NRC is projected to utilize the CRAB multiphysics software driver for executing both design and beyond-design-basis accident analyses. Furthermore, the NRC has been utilizing the MELCOR code to calculate mechanistic source terms during accidents. Since MELCOR relies on isotopic inventory and reactor temperature/power profiles under accident conditions, which theoretically can be derived from CRAB, the goal is to establish a comprehensive CRAB-MELCOR computational framework. Past work was focused on testing and demonstrating CRAB's capability to generate results that can be used to inform mechanistic source term calculations in MELCOR. In particular, a computational workflow leveraging OpenMC-generated microscopic cross sections and CRAB was first applied to perform multiphysics microscopic depletion calculation followed by an accident scenario for a stylized microreactor problem. In fiscal year 2024, the research work has been focused on applying the OpenMC-CRAB workflow, which was first tested in fiscal year 2023, to a realistic 3D heat-pipe cooled MR problem representative of the eVinci TM design. The latter computational problem was developed with inputs from WEC to conserve selected neutronic and thermal characteristics of the eVinci TM design without releasing proprietary data. The results of this simulation, encompassing isotopic inventory, power density distribution, and kinetic parameters, will inform both MELCOR and the WEC-developed FATE code for mechanistic source terms calculations. The results from the two codes will then be compared for code verification purposes. This report contains the design characteristics of the realist heat pipe cooled microreactor developed as a use-case for the verification exercise, and the current results for the multiphysics microscopic depletion performed with the OpenMC-CRAB workflow. The results include eigenvalue as a function of time, power distribution at EOL, in addition to nuclides inventory's time evolution and spatial distribution. Finally, we report improvements to the workflow efficiency achieved through a collaboration with the NEAMS programs. Through this collaborative effort, we were able to strongly decrease the computational time for the multiphysics microdepletion calculation (i.e., from 17.4 hours to 5.7 hours on 280 processors) in addition to simplifying the interface to generate isotopics spatial distribution utilizable by FATE and MELCOR. Future work, including the improvement of the current microscopic cross-sections' library and the simulation of an accident scenario at EOL, is also discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stainless Steel Vacuum Chamber for Scanning Transmission X-ray Microsopy

The stainless steel chamber was specifically conceived and designed for housing an interferometer controlled scanning transmission x-ray microscope (STXM). The construction of the chamber is such that internal components of the microscope rest within the chamber and are fixed to a 4 inch stainless steel belly band. The integral and most important part of the chamber is the belly band, which serves to isolate high frequency vibrations (e.g., floor surroundings, people traffic) from the sensitive measurements performed using the microscope. In addition, the chamber effectively acts as a sound barrier to the nanometer measurements conducted within. The assembled chamber (and microscope) are readily adjustable at the micron level using strut members external to the chamber but fixed to the belly band and a stand made of polymer concreate.

Kilcoyne, Arthur L.↗

Use of a focusing vortex lens as the objective in spiral phase contrast microscopy

A method and objective apparatus are provided for implementing an enhanced phase contrast microscope. A focusing vortex lens, defined by a diffractive spiral zone plate (SZP) lens, is used for the objective for the phase contrast microscope. The SZP lens focuses and imparts a helical phase to incident illumination to image the specimen with spiral phase contrast. The spiral phase contrast microscope is sensitive to phase gradients in all sample axes. Replacing the objective of a microscope with the diffractive SZP lens of the invention immediately provides existing instruments with spiral phase contrast capability.

McNulty, Ian↗

Performance Prediction of Irradiated TREAT Fuel

Poster Title: Performance Prediction of Irradiated TREAT Fuel The poster presents findings about the irradiation damage layer effects on the microscopic fuel temperature profile in TREAT. Microscopic fuel particles in TREAT are small enough that fission fragments travel out of the particles causing thermal property reduction in a shell around the fuel particle. The use of Magpie and MAMMOTH code is illustrated. The thermal temperature solution is simulated using EOS pulse power data. The reduction of microscopic fuel particle size reduced the irradiation damage due to fission fragments. The reduction of fission events is shown to be greater than the increase in fission fragments leaving the particle as size decreases. The temperature difference between the microscopic fuel particle and bulk graphite is shown to increase with irradiation as the damage layer grows.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method for error correction in scanning probe microscopy

Disclosed here is a scanning probe microscope system and method for operating the same for producing scanning probe microscope images at fast scan rates and reducing oscillation artifacts. In some embodiments, an inverse consistent image registration method is used to align forward and backward scan traces for each line of the scanning microscope image. In some embodiments, the aligned forward and backward scan traces are combined using a weighting factor favoring the scan trace with higher smoothness. In some embodiments, the scanning probe microscope image is a potentiometry map and a method is provided to extract from the potentiometry map a conductivity map.

47 OTHER INSTRUMENTATION↗

Dimensionality Reduction Algorithms for Big Nuclear Data Streams with Application to SCALE Cross Sections

A central problem in performing accurate nuclear reactor simulations is the ability to capture the changes in the few group microscopic cross sections as functions of system state, e.g. moderator density, fuel temperature, or neutron spectrum, and time and/or burnup of the fuel. For most reactor simulation scenarios, this results in huge data stream, which must be interpolated as needed by downstream calculations (e.g., core-wide simulation). This is typically accomplished by using sophisticated interpolating functions to capture the few-group variations over the wide range of conditions expected during operation. To address handling this big data, this paper explores the use of dimensionality reduction (DR) techniques to identify the true dimensionality of the data prior to its use in the calculations. This could significantly reduce the computational cost required for data processing/manipulation, thus reducing a significant portion of the total calculations time. By way of an example, in the current version of the ORIGEN-ARP module, the assembly-averaged microscopic cross sections at different conditions, e.g., fuel enrichments, irradiation history and water density, which are calculated using the TRITON sequence and interpolated on-demand by the ARP module to model assembly depletion for a wide range of assembly types (e.g. Westinghouse 17x17 and GE 9x9) over a wide range of conditions. This approach typically results in ∼1 GB per assembly type, which although not insurmountable, can be impractical for distribution. and it is the premise of this paper that most of this data is heavily correlated and hence can take great benefit of condensation via DR. To demonstrate DR, the proposed algorithm is applied to the nuclear data streams generated by SCALE 6.1. Using the depletion sequence (TRITON), microscopic cross sections are calculated for a mixed oxide (MOX) fuel assembly design at a representative range of fuel enrichments and fuel burnup. In conventional core simulators, multi dimensional interpolation of these cross sections is used to provides neutronics feedback due to local conditions without returning to expensive TRITON calculations for every change. This paper shows that dimensionality reduction can help compress the size of the cross section data without sacrificing the accuracy of their reconstruction at all conditions of interest. This work explores the application of dimensionality reduction algorithms to nuclear data streams typically employed in support of conventional full-core reactor calculations which rely on interpolation of pre-calculated microscopic cross sections. In particular, analysis of the few group MOX cross sections revealed that a large degree of dependencies exist between the few-group cross sections, which can be revealed via range-finding algorithms. Specifically, correlations between different reaction types for the same isotope have been identified, and correlations between different enrichments and correlations across different isotopes have been identified. This paper demonstrates that the reduction errors can be quantified, and they are uncorrelated with the range of variations for the various cross sections. In future work, we will focus on identifying the smallest rank that takes into account all types of correlations across the range of conditions used to model cross section variations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time Reversal Violation

This talk briefly reviews three types of time-asymmetry in physics, which I classify as universal, macroscopic and microscopic. Most of the talk is focused on the latter, namely the violation of T-reversal invariance in particle physics theories. In sum tests of microscopic T-invariance, or observations of its violation, are limited by the fact that, while we can measure many processes, only in very few cases can we construct a matched pair of process and inverse process and observe it with sufficient sensitivity to make a test. In both the cases discussed here we can achieve an observable T violation making use of flavor tagging, and in the second case also using the quantum properties of an antisymmetric coherent state of two B mesons to construct a CP-tag. Both these tagging properties depend only on very general properties of the flavor and/or CP quantum numbers and so provide model independent tests for T-invariance violations. The microscopic laws of physics are very close to T-symmetric. There are small effects that give CP- and T-violating processes in three-generation-probing weak decays. Where a T-violating observable can be constructed we see the relationships between T-violation and CP-violation expected in a CPT conserving theory. These microscopic effects are unrelated to the 'arrow of time' that is defined by increasing entropy, or in the time direction defined by the expansion of our Universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rapid imaging of mycoplasma in solution using Atmospheric Scanning Electron Microscopy (ASEM)

Highlights: Black-Right-Pointing-Pointer Mycoplasma mobile was observed in buffer with the Atmospheric Scanning Electron Microscope. Black-Right-Pointing-Pointer Characteristic protein localizations were visualized using immuno-labeling. Black-Right-Pointing-Pointer M. mobile attached to sialic acid on the SiN film surface within minutes. Black-Right-Pointing-Pointer Cells were observed at low concentrations. Black-Right-Pointing-Pointer ASEM should promote study and early-stage diagnosis of mycoplasma. -- Abstract: Mycoplasma is a genus of bacterial pathogen that causes disease in vertebrates. In humans, the species Mycoplasma pneumoniae causes 15% or more of community-acquired pneumonia. Because this bacterium is tiny, corresponding in size to a large virus, diagnosis using optical microscopy is not easy. In current methods, chest X-rays are usually the first action, followed by serology, PCR amplification, and/or culture, but all of these are particularly difficult at an early stage of the disease. Using Mycoplasma mobile as a model species, we directly observed mycoplasma in buffer with the newly developed Atmospheric Scanning Electron Microscope (ASEM). This microscope features an open sample dish with a pressure-resistant thin film window in its base, through which the SEM beam scans samples in solution, from below. Because of its 2-3 {mu}m-deep scanning capability, it can observe the whole internal structure of mycoplasma cells stained with metal solutions. Characteristic protein localizations were visualized using immuno-labeling. Cells were observed at low concentrations, because suspended cells concentrate in the observable zone by attaching to sialic acid on the silicon nitride (SiN) film surface within minutes. These results suggest the applicability of the ASEM for the study of mycoplasmas as well as for early-stage mycoplasma infection diagnosis.

60 APPLIED LIFE SCIENCES↗

Formation and Morphology of "shish-like" Fibril Crystals of Aliphatic Polyesters from the Sheared Melt

We found the formation of 'shish-like' fibril crystals of aliphatic polyesters such as poly(L-lactic acid) (PLLA), poly({var_epsilon}-caprolactone) (PCL), poly(12-hydroxydodecanoic acid) (PHDA) and poly(16-hydroxyhexadecanoic acid) (PHHA) from the sheared melt with shear rate {gamma} = 5 s{sup -1} observed by polarizing optical microscope (POM). The melting temperature T{sub m}s of obtained fibril crystals of PLLA and PCL were higher than those of spherulites and were close to the equilibrium melting temperature T{sub m}{sup 0}. The small angle X-ray scattering (SAXS) patterns from the bulk sample including fibril crystals, small amount of unoriented small crystals and amorphous showed no peaks arose from the existence of long periods in fibril crystals. These are the evidence that the observed fibril crystals consist of assemblies of a lot of extended chain crystals (ECCs). We observed the morphology of moderately extracted single strand of fibril crystals at the magnification of POM by means of scanning electron microscope. We found that macroscopic fibril crystals of PLLA with diameter d = 10 {micro}m consist of the bundle structure of microscopic fibril crystals with d = 2 {micro}m. From POM observation of the formation of fibril crystals of PLLA and PCL, we showed phase diagrams of molecular weight M and crystallization temperature T{sub c} for the formation of fibril crystals. From these phase diagrams, we evaluated a critical M and T{sub c} for the formation of fibril crystals. Moreover, from the sequential melting and crystallization experiments, it was implied that the entanglement and transesterification play an important role on the formation of fibril crystals of aliphatic polyesters.

36 MATERIALS SCIENCE↗

Photoreduction of CO{sub 2} by TiO{sub 2} nanocomposites synthesized through reactive direct current magnetron sputter deposition.

The photoreduction of CO{sub 2} into methane provides a carbon-neutral energy alternative to fossil fuels, but its feasibility requires improvements in the photo-efficiency of materials tailored to this reaction. We hypothesize that mixed phase TiO{sub 2} nano-materials with high interfacial densities are extremely active photocatalysts well suited to solar fuel production by reducing CO{sub 2} to methane and shifting to visible light response. Mixed phase TiO{sub 2} films were synthesized by direct current (DC) magnetron sputtering and characterized by X-ray diffraction (XRD), atomic force microscope (AFM), scanning electron microscope (SEM) and transmission electron microscope (TEM). Bundles of anatase-rutile nano-columns having high densities of two kinds of interfaces (those among the bundles and those between the columns) are fabricated. Films sputtered at a low deposition angle showed the highest methane yield, compared to TiO{sub 2} fabricated under other sputtering conditions and commercial standard Degussa P25 under UV irradiation. The yield of methane could be significantly increased ({approx} 12% CO{sub 2} conversion) by increasing the CO{sub 2} to water ratio and temperature (< 100 C) as a combined effect. These films also displayed a light response strongly shifted into the visible range. This is explained by the creation of non-stoichiometric titania films having unique features that we can potentially tailor to the solar energy applications.

03 NATURAL GAS↗

Contributed Review: Review of integrated correlative light and electron microscopy

New developments in the field of microscopy enable to acquire increasing amounts of information from large sample areas and at an increased resolution. Depending on the nature of the technique, the information may reveal morphological, structural, chemical, and still other sample characteristics. In research fields, such as cell biology and materials science, there is an increasing demand to correlate these individual levels of information and in this way to obtain a better understanding of sample preparation and specific sample properties. To address this need, integrated systems were developed that combine nanometer resolution electron microscopes with optical microscopes, which produce chemically or label specific information through spectroscopy. The complementary information from electron microscopy and light microscopy presents an opportunity to investigate a broad range of sample properties in a correlated fashion. An important part of correlating the differences in information lies in bridging the different resolution and image contrast features. The trend to analyse samples using multiple correlated microscopes has resulted in a new research field. Current research is focused, for instance, on (a) the investigation of samples with nanometer scale distribution of inorganic and organic materials, (b) live cell analysis combined with electron microscopy, and (c) in situ spectroscopic and electron microscopy analysis of catalytic materials, but more areas will benefit from integrated correlative microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Situ Laser Synthesis of Si Nanowires in the Dynamic TEM

Nanowires (NWs) are a crucial component in today's nanoscale devices and are vital to the further development of nanotechnology. To achieve reliable growth of NWs and uniform electronic properties, the specific mechanisms that control the structural development of NWs and the correlation between NWs and their nucleation and growth processes must be examined. Because imaging is not possible in Chemical Vapor Deposition (CVD) chambers, in situ transmission electron microscope (TEM) based growth methods provide a method for characterizing NW evolution. In this paper, we describe a new method of in situ synthesis and imaging of NWs using laser-assisted growth inside a TEM. The vapor-liquid solid (VLS) growth mechanism (Figure 1), first described by Wagner and co-workers, is a widely accepted description of how many 1D nanostructures are formed. VLS and similar models have been applied to such methods as hybrid pulsed-laser ablation/chemical vapor deposition (PLA/CVD) and laser assisted NW growth at elevated temperatures, in which a pulsed laser ablates a target with gas flowing through the reaction chamber held at elevated temperature. These methods have successfully produced semiconductor and conducting oxide NWs with size control determined by the catalyst droplet diameter. The VLS description of NW growth is a widely accepted model, but the exact role of vapor species and its interaction with the catalyst particle is not fully understood. For example, NW growth has been observed to occur far below predicted eutectic temperatures, which suggests that alternative mechanisms such as solid-liquid-solid growth (SLS) may play a role. Many NW fabrication techniques preclude direct in situ characterization of the growth process. Because of this need for direct observation during growth, TEM-based NW growth methods have become increasingly popular. Though progress has been made in the study of the VLS mechanism of NW growth using in situ TEM, conventional in situ growth experiments are limited by the standard video frame rate ({approx}30 Hz). Because of this limitation, relationships between reactant incorporation and transport, catalyst-wire interface development, and wire growth texture remain somewhat unclear. Moreover, laser-assisted phenomena (PLA or PLA/CVD) cannot be studied with conventional in situ TEM, which is typically performed with environmental TEM techniques using resistive heating. A novel form of in situ TEM for the study of NW growth by laser-assisted techniques is described in this paper. Here we present an in situ method for PLA synthesis of 1D nanostructures using the dynamic transmission electron microscope (DTEM)[18,19] that will permit the details of laser-assisted NW synthesis to be elucidated. The DTEM, schematically shown in Figure 2, consists of a TEM column (JEOL 2000FX) to which a pulsed Nd:YAG laser, labeled 'hydrodrive laser' in Fig. 2, is added. This laser is incident directly on the sample and can be operated at 1064, 532 or 355nm. The direct delivery of energy initiates a phase change or reaction that is investigated in situ during the experiment. Thus, the microscope can be used to fabricate NWs while simultaneously characterizing the reaction products created by each laser pulse. A second pulsed laser (15-ns-duration frequency-quintupled Nd:YLF) added to the column (labeled 'cathode laser' in figure 2) enables operation in both a pulsed photoemission and conventional thermionic continuous-wave (CW) electron beam imaging modes.[19] The pulsed mode's nanosecond-scale imaging capability greatly exceeds the {approx}30 Hz time resolution of conventional in situ TEM and can potentially provide a detailed understanding of NW growth. Time-resolved imaging experiments aimed at capturing the intermediate states at nanosecond time scales in PLA NW growth are underway and will be addressed in a future publication. In this paper, we present results obtained using in situ imaging in conventional CW imaging mode, but taking advantage of the DTEM's in situ laser drive capability. Specifically, we will present the first results using the sample ('hydro-drive') laser at 355nm to stimulate the growth of the nanostructures, therefore revealing the DTEM as a tool for in situ imaging of nanostructure synthesis (see the experimental section for details of the NW synthesis procedure).

36 MATERIALS SCIENCE↗