Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

A Real2Sim Digital Twin Pipeline for Photorealistic Robot Simulation: Evaluating VLA Policy Deployment on a Bimanual Mobile Robot

Digital twins that are automatically constructed from robot sensor data offer a promising pathway for scalable Real2Sim and Sim2Real transfer. However, it remains an open question whether photorealistic reconstruction alone is sufficient to support reliable deployment of vision-language-action (VLA) policies. We present a generative-AI-assisted Real2Sim pipeline that generates simulation-ready digital twins from real-world RGB observations with minimal manual intervention. The pipeline uses prompted segmentation to isolate scene components and a generative 3D model to directly produce simulation assets, eliminating the need for traditional multi-view reconstruction or manual 3D modeling.\r\nTo evaluate simulation fidelity, we deploy and compare policies from two VLA models in both the real robot and the reconstructed\r\nsimulation under identical tasks and initial conditions. We compare joint-level action trajectories and analyze how divergence evolves over time in closed-loop execution. Although the reconstructed environments are visually accurate, we observe increasing trajectory divergence during closedloop operation. These results indicate that photorealistic reconstruction alone is insufficient to preserve closed-loop control behavior\r\nin VLA policies, particularly in contact-rich manipulation settings where small perceptual errors compound over time.

97 MATHEMATICS AND COMPUTING↗

Upland tidal brackish marsh specific conductivity and salinity measurements, PIE LTER, Plum Island Sound, MA, 2023

This dataset includes raw and corrected specific conductivity, temperature, and calculated salinity measurements collected at 10 cm depth in a Typha angustifolia-dominated tidal brackish wetland at the upper estuary of Plum Island Sound in Newbury, Massachusetts (MA) within the Plum Island Ecosystems Long Term Ecological Research (PIE LTER) site. Measurements were taken to evaluate temporal variation in porewater salinity (a proxy for porewater sulfate concentration) in high frequency to assess soil and plant responses to changes in salinity. Measurements were collected using an Onset HOBO U24-002 Saltwater Conductivity/Salinity data logger deployed in a well. Specific conductivity was corrected using non-linear temperature compensation, and salinity was calculated using the Practical Salinity Scale 1978 via Onset's HOBOware software. Reference conductivity measurements to correct for sensor drift were taken at the start and end of each deployment using a HACH HQ14D Portable Conductivity Meter. Data were then filtered in MATLAB to remove values logged while the sensor was out of the well or during post-deployment equilibration. Detailed metadata, including variable descriptions, sampling methods, QA/QC procedures, and site information, are provided in the files: Typha_ctd_salinity_dd.csv and Typha_MI_ctd_salinity_2023_flmd.csv.

54 ENVIRONMENTAL SCIENCES↗

Upland tidal brackish marsh specific conductivity and salinity measurements, PIE LTER, Plum Island Sound, MA, May-December 2022

This dataset includes raw and corrected specific conductivity, temperature, and calculated salinity measurements collected at 10 cm depth in a Typha angustifolia-dominated tidal brackish wetland at the upper estuary of Plum Island Sound in Newbury, Massachusetts (MA) within the Plum Island Ecosystems Long Term Ecological Research (PIE LTER) site. Measurements were taken to evaluate temporal variation in porewater salinity (a proxy for porewater sulfate concentration) in high frequency to assess soil and plant responses to changes in salinity. Measurements were collected using an Onset HOBO U24-002 Saltwater Conductivity/Salinity data logger deployed in a well. Specific conductivity was corrected using non-linear temperature compensation, and salinity was calculated using the Practical Salinity Scale 1978 via Onset's HOBOware software. Reference conductivity measurements to correct for sensor drift were taken at the start and end of each deployment using a HACH HQ14D Portable Conductivity Meter. Data were then filtered in MATLAB to remove values logged while the sensor was out of the well or during post-deployment equilibration. Detailed metadata, including variable descriptions, sampling methods, QA/QC procedures, and site information, are provided in the files: Typha_ctd_salinity_dd.csv and Typha_MI_ctd_salinity_2023_flmd.csv.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of non-invasive biomonitoring of 2,4-Dichlorophenoxyacetic acid (2,4-D) in saliva

The objective of this study was to evaluate the potential for noninvasive biomonitoring of 2,4-dichlorophenoxyacetic acid (2,4-D) in saliva. Using an in vitro rat salivary gland epithelial cell (SGEC) system, a collection of experiments investigating chemical protein binding, temporal and directional transport, as well as competitive transport with para-aminohippuric acid (PAH), a substrate for renal organic anion transporters, was conducted to identify cellular transport parameters required to computationally model salivary transport of 2,4-D. Additionally, a physiological protein gradient was implemented to mimic physiologically relevant concentrations of protein in rat plasma and saliva, and under these conditions the transfer of 2,4-D was markedly slower, driven by increased protein binding (i.e. reduced free 2,4-D species available to cross salivary barrier). The rate of transfer was directly proportional to the amount of unbound 2,4-D and demonstrated no indication of active transport. An in vivo assessment of 2,4-D exposure in rats revealed a non-linear protein binding response in plasma, indicating saturated protein binding and increased levels of free 2,4-D species at higher doses. A strong correlation between concentrations in saliva and free unbound species in plasma was observed (Pearson correlation coefficient = 0.95). Saliva:plasma 2,4-D ratios measured in vivo (0.0079) were comparable over dose, but significantly different than ratios measured in vitro (physiological conditions) (0.034), possibly due to 2,4-D concentrations in saliva not being at equilibrium with 2,4-D concentrations in blood, as well as physiological features absent in in vitro settings (e.g. blood flow). We demonstrated that 2,4-D is consistently transported into saliva using both in vitro and in vivo models, making 2,4-D a potential candidate for human non-invasive salivary biomonitoring. Further work is needed to understand whether current sensor limits of detection are sufficient to measure occupationally relevant exposures.

Carver, Zana A.↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Test Beam Results of a Heavily Irradiated Current Injected Detector (CID)

A heavily irradiated (3 x 10{sup 15} 1 MeV n{sub eq}/cm{sup 2}) Current Injected Detector (CID) was tested with 225 GeV muon beam at CERN H2 beam line. In the CID concept the current is limited by the space charge. The injected carriers will be trapped by the deep levels and this induces a stable electric field through the entire bulk regardless of the irradiation fluence the detector has been exposed to. The steady-state density of the trapped charge is defined by the balance between the trapping and the emission rates of charge carriers (detrapping). Thus, the amount of charge injection needed for the electric field stabilization depends on the temperature. AC-coupled 16 cm{sup 2} detector was processed on high resistivity n-type magnetic Czochralski silicon, and it had 768 strips, 50 {mu}m pitch, 10 {mu}m strip width and 3.9 cm strip length. The beam test was carried out using a silicon beam telescope that is based on the CMS detector readout prototype components, APV25 readout chips, and eight strip sensors made by Hamamatsu having 60 {mu}m pitch and intermediate strips. The tested CID detector was bonded to the APV25 readout, and it was operated at temperatures ranging from -40 to -53 C. The CID detector irradiated at 3 x 10{sup 15} 1 MeV n{sub eq}/cm{sup 2} fluence shows about 40% relative Charge Collection Efficiency with respect to the non-irradiated reference plane sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: Retrospective physician surveys including chart reviews at numerous centers

In a 2-part study, we first examined the results of 71 surveyed physicians who provided responses on how they address the management of patients who maintained either a pacemaker or a defibrillator during radiation treatment. Second, a case review study is presented involving 112 medical records reviewed at 18 institutions to determine whether there was a change in the radiation prescription for the treatment of the target cancer, the method of radiation delivery, or the method of radiation image acquisition. Statistics are provided to illustrate the level of administrative policy; the level of communication between radiation oncologists and heart specialists; American Joint Committee on Cancer (AJCC) staging and classification; National Comprehensive Cancer Network (NCCN) guidelines; tumor site; patient's sex; patient's age; device type; manufacturer; live monitoring; and the reported decisions for planning, delivery, and imaging. This survey revealed that 37% of patient treatments were considered for some sort of change in this regard, whereas 59% of patients were treated without regard to these alternatives when available. Only 3% of all patients were identified with an observable change in the functionality of the device or patient status in comparison with 96% of patients with normal behavior and operating devices. Documented changes in the patient's medical record included 1 device exhibiting failure at 0.3-Gy dose, 1 device exhibiting increased sensor rate during dose delivery, 1 patient having an irregular heartbeat leading to device reprogramming, and 1 patient complained of twinging in the chest wall that resulted in a respiratory arrest. Although policies and procedures should directly involve the qualified medical physicist for technical supervision, their sufficient involvement was typically not requested by most respondents. No treatment options were denied to any patient based on AJCC staging, classification, or NCCN practice standards.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sap flow data from San Lorenzo, Panama (PA-SLZ), 2019

This data package contains sap flow data from the NGEE Tropics site in San Lorenzo, Panama (PA-SLZ) from 22 January 2019 to 31 December 2019. Sap flow measurements quantify plant-level transpiration, which varies across spatial and temporal scales. It is a key trait in understanding plant hydraulic functioning. Here sap flow was measured using ‘Granier-type’ thermal dissipation probes. Raw data downloaded from each data logger are in the 'Raw data' folder as CSV files, along with the Campbell data logger programs which can be read when opened with a text editor. The data was processed using the AquaFlux package in R. R code for preparing the data for use in AquaFlux is in the 'R code for pre-processing data folder'; it is saved as a text file that can be copy and pasted into R. The processed data for each data logger is in the 'Processed data' folder as CSV files. Documentation for the Granier sensors and AquaFlux package is in the ‘Manuals’ folder as PDF files.

54 ENVIRONMENTAL SCIENCES↗

FTICR-MS, Sensor, and Environmental Data from 5 Streams Impacted by the 2020 Holiday Farm Fire Associated with: "Spatiotemporal controls on the delivery of dissolved organic matter to streams following a wildfire"

This data package is associated with the publication "Spatiotemporal Controls on the Delivery of Dissolved Organic Matter to Streams Following a Wildfire" submitted to Geophysical Research Letters (Roebuck et al., 2022). The study aims to understand storm induced transport of pyrogenic materials to streams impacted by varying degrees of burn severity. Time series samples (24 samples in 1-hour intervals) were collected at 5 sites within the McKenzie River Watershed (Oregon, USA) whose catchment were each completely engulfed by the 2020 Holiday Farm Fire. The samples were collected in November 2020 during the first major storm pulse following the conclusion of the wildfire. Samples were characterized for dissolved organic carbon, total dissolved nitrogen, and by ultra-high resolution mass spectrometry. In situ turbidity data also collected.This data package contains 4 primary folders that include the following: 1) Metadata, 2) EnvData (Environmental Data), 3) SensorData, and 4) FTICR_SupportingData. The package contains a single file-level metadata (flmd) file. Each primary folder also contains individual data dictionaries (dd) to define and provide descriptors of column/row headers and data flags. The FTICR_SupportingData, folder 4, contains raw, unprocessed FTICR-MS Data files in addition to a csv containing processed FTICR-MS data. This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Reduction of 1/f noise in graphene after electron-beam irradiation

We investigated experimentally the effect of the electron-beam irradiation on the level of the low-frequency 1/f noise in graphene devices. It was found that 1/f noise in graphene reduces with increasing concentration of defects induced by irradiation. The increased amount of structural disorder in graphene under irradiation was verified with micro-Raman spectroscopy. The bombardment of graphene devices with 20-keV electrons reduced the noise spectral density, S{sub I}/I{sup 2} (I is the source-drain current) by an order-of magnitude at the radiation dose of 10{sup 4} {mu}C/cm{sup 2}. We analyzed the observed noise reduction in the limiting cases of the mobility and carrier number fluctuation mechanisms. The obtained results are important for the proposed graphene applications in analog, mixed-signal, and radio-frequency systems, integrated circuits and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Use of Satellite Observations for Detecting Large CO 2 Leaks and Carbon Sequestration Monitoring

We tested the feasibility of orbital CO 2 sensors as detectors of leaks from sequestration sites using the SCIAMACHY and GOSAT instruments. From the footprint size of each instrument we calculated the atmospheric volume sampled by SCIAMACHY and GOSAT readings, and from this data the amount of CO 2 leakage necessary to measurably impact readings from the instruments. We used a high-emission coal electric plant as a baseline leak quantity, which is a substantially larger amount of CO 2 than would be expected from a sequestration leak. Nonetheless, the plant’s output is not detectable by either instrument. Geospatial and geostatistical analysis of collected data supports this conclusion. SCIAMACHY data from the summer of 2005 over the contiguous US showed broad topographic patterns in CO 2 distribution, with the eastern flanks of mountain ranges hosting anomalously high levels of CO 2 , and basin regions hosting lows. The cause of these tendencies has not been determined. Calculations applied to the OCO-2 instrument, scheduled for a 2013 launch, found that it will be capable of detecting the coal plant’s emission and may be a viable tool for detecting large carbon leaks from sequestration sites.

20 FOSSIL-FUELED POWER PLANTS↗

Basic Energy Sciences Roundtable: Opportunities for Basic Research for Next-Generation Quantum Systems

For decades, scientists have predicted that devices based on “quantum phenomena” will be able to store and manipulate information to provide radical new approaches for computing, communication, and sensing. However, only recently have quantum phenomena been incorporated into technologies for next-generation computers, sensors, and detectors that demonstrate performance characteristics rivaling those of their conventional counterparts. These devices clearly demonstrate the enormous potential for future quantum-based technologies. The novel quantum device capabilities currently envisioned include enhanced resolution in imaging, sensors, and detectors; advanced cryptography for more secure communication; and significantly larger computational capabilities at speeds far greater than those possible in classical computing. However, realizing these advances requires a detailed understanding of how quantum systems (including quantum materials or assemblies of trapped ions and electrons) behave, accurate knowledge of how to integrate the components into complex systems, and precise control of the structures. In this context, creating and controlling quantum states within molecules and materials offer exciting scientific opportunities for fundamental research, as well as for enabling next-generation quantum-based technologies. Numerous questions remain, ranging from how quantum interactions may enable innovation through the creation of novel quantum systems, to how these new quantum technologies can advance our understanding of matter and chemistry at the most fundamental levels. To address these questions and identify priority research opportunities (PROs), the US Department of Energy (DOE) Office of Basic Energy Sciences (BES) convened a roundtable of experts in quantum materials and quantum systems encompassing the fields of physics, chemistry, materials synthesis science, device engineering, detector technology, and atomic-scale characterization techniques. This group of experimentalists and theorists met on October 30–31, 2017, to explore scientific research opportunities in this rapidly moving field, in which BES support can play a key role in advancing and utilizing quantum information science (QIS). The goals of this roundtable were to define the unique roles for BES in this active research field and to provide input on future research directions, forming the basis for a coordinated, long-term research effort that will enable major advances in quantum-based science and technology. BES is uniquely positioned to advance this field because of its long history of fundamental research support for both materials and chemical sciences, along with its construction and operation of world-class scientific user facilities. Fundamental research in this area is strongly coupled to DOE efforts in scientific computing, high-energy physics, and accelerator/detector research and related to activities in “Beyond Moore’s Law” computing, next-generation semiconductor materials, and exascale computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Undoped and doped poly(tetraphenylbenzidine) as sensitive material for an impedimetric nitrogen dioxide gas dosimeter

This article presents a nitrogen dioxide (NO{sub 2}) detecting gas dosimeter based on poly(tetraphenylbenzidine) poly(TPD) as nitrogen oxide (NO{sub x}) sensitive layer. Gas dosimeters are suitable devices to determine reliably low levels of analytes over a long period of time. During NO{sub x} exposure, the analyte molecules are accumulated irreversibly in the sensing layer of the dosimeter enhancing the conductivity of the hole conducting poly(TPD), which can be measured by impedance spectroscopy. Due to their possibility for low cost production by simple printing techniques and very good physical, photochemical, and electrochemical properties, poly(TPD)s are suitable for application in gas dosimeters operated at room temperature. We studied the effect of doping with a Co(III)-complex in combination with a conducting salt on the dosimeter behavior. Compared to the undoped material, a strong influence of the doping can be observed: the conductivity of the sensing material increases significantly, the noise of the signal decreases and an unwanted recovery of the sensor signal can be prevented, leading to a NO{sub x} detection limit <10 ppm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physical and hydraulic forces experienced by fish passing through three different low-head hydropower turbines

Knowing the kinds of physical stress experienced by fish passing through hydropower turbines can help optimise technologies and improve fish passage. This paper assesses the hydraulic conditions experienced through three different low-head turbines (a very low head (VLH), Archimedes screw and horizontal Kaplan turbine), taken using an autonomous sensor. In total, 127 Sensor Fish deployments were undertaken across all three turbines, generating 82 valid datasets. Decompression was rare at the VLH and screw turbines and rarely fell more than 10kPa below atmospheric pressure. In contrast, the Kaplan was capable of generating pressures as low as 55.5kPa (~45kPa below atmospheric pressure), over shorter periods of time. More severe ratios of pressure changes could, therefore, be expected for both surface- and depth-acclimated fish at the Kaplan than at the other turbines. Strike was another possible source of fish injury (detected in 69–100% of deployments), and although strike severity was highest at the Kaplan, strike was more likely to be encountered at the screw and VLH than the Kaplan turbine. Shear occurred only near the blades of the Kaplan, and not at severe levels. The results demonstrated that low-head hydropower facilities are not without their risks for downstream migrating fish.

Boys, Craig A. (ORCID:0000000264342937)↗

Development of an Energy Efficient and Cost Effective Autonomous Vehicle Research Platform

Commercialization of autonomous vehicle technology is a major goal of the automotive industry, thus research in this space is rapidly expanding across the world. However, despite this high level of research activity, literature detailing a straightforward and cost-effective approach to the development of an AV research platform is sparse. To address this need, we present the methodology and results regarding the AV instrumentation and controls of a 2019 Kia Niro which was developed for a local AV pilot program. This platform includes a drive-by-wire actuation kit, Aptiv electronically scanning radar, stereo camera, MobilEye computer vision system, LiDAR, inertial measurement unit, two global positioning system receivers to provide heading information, and an in-vehicle computer for driving environment perception and path planning. Robotic Operating System software is used as the system middleware between the instruments and the autonomous application algorithms. After selection, installation, and integration of these components, our results show successful utilization of all sensors, drive-by-wire functionality, a total additional power* consumption of 242.8 Watts (*Typical), and an overall cost of $118,189 USD, which is a significant saving compared to other commercially available systems with similar functionality. This vehicle continues to serve as our primary AV research and development platform.

33 ADVANCED PROPULSION SYSTEMS↗

The Future of Robotics/Remote Handling Solutions for the Nuclear Industry - 17347

The nuclear industry is seeing a resurgence of development and utilization of advanced integrated systems; fused sensor arrays; autonomous, remote and hybrid operations; and augmented reality display and control system interfaces. A new age of 'robotics' and remote handling technologies. For many years the use of robotics in nuclear applications has been done sparingly due to technical limitations, perceived and real reliability issues, perceived and real risk concerns, and cost. Although robotics have been used successfully on a variety of projects globally, the underuse of this technology, particularly within the nuclear industry both public and private, is overwhelming. As the number of complex, high hazard projects in the nuclear industry increases, the use of robotics for maintenance, inspection, repair, decommissioning, and remediation activities will become increasingly vital in the future. The risks associated with direct human exposure are high and thus eliminating the risk, or managing it to acceptable levels by using robotics/remote handling as well as other technologies is critical to success as more extreme environment operations and tasks are undertaken. Recent and ongoing advances in technology now allows us to safely and effectively remove the direct / in-situ human element from these type of activities. All the while delivering the same or better outcomes when considering the alternatives when limited or no direct / in-situ human intervention would be allowed. The biggest obstacles the nuclear industry faces center on the cost, reliability, maintainability, effectiveness and appropriate uses of robotics/remote handling solutions in a nuclear (radiation and/or contamination) environment. In order to mitigate these concerns, a sound approach to the use of robotics needs to be addressed. This approach must include: 1. A better understanding of what technology is available and how it can be utilized across multiple sectors, e.g. Commercial Off-the-Shelf (COTS) technology modified / adapted for the nuclear sector; 2. How to implement technology in an integrated pragmatic approach that is cost effective by combining technological know-how / subject matter expertise (SME) with the equivalent subject matter expertise in regulatory, operational and maintenance requirements and limitations, such that a more complete set of functional and operational requirements can be jointly developed in the process. 3. The integration of requirements (project, site, regulatory, etc.), risk management (human factors) and technology, i.e. a marriage between political, programmatic, and technological factors. As the development of robotic/remote handling technology progresses and the successful implementation on projects is demonstrated, the better off the industry will be. This paper provides an overview of the fundamental issues facing the nuclear industry with regard to effective and successful technology selection, maturation, deployment, and integrated risk management, and offers suggestions on how we may overcome these persistent issues now and in the future. Robotic systems and solution experts that are focused on the integration of proven technologies - and that are an integrated part of the project team from its onset - are a necessity for successful planning during nuclear operations. The approach to nuclear operations should always be, 'what is the simplest, most effective way we can approach a particular project need?'. Understanding and implementing the right technologies is where the true value will be recognized. The integration of systems, which includes more than just robotics, is key when developing schemes for these types of complex operations. Often times during planning, the remote handling needs of the job are set aside to be evaluated at a later time due to risk concerns and lack of knowledge. The issue is, experts in the area of robotics or remote handling are rarely involved in the upfront planning. As a result, unnecessary constraints, risks, and obstacles are imposed on project teams to deliver. If done intelligently, this should be introduced at the forefront of planning. Using this type of sound approach leads to effective task organization for the end user. By developing an overall philosophy that leverages proven technologies with implementation expertise; i.e. solutions versus products, is a recipe for success. This is the area that is under-appreciated in the industry and one that needs to be recognized on a much broader scale. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomic gravitational wave interferometric sensor

We propose two distinct atom interferometer gravitational wave detectors, one terrestrial and another satellite based, utilizing the core technology of the Stanford 10 m atom interferometer presently under construction. Each configuration compares two widely separated atom interferometers run using common lasers. The signal scales with the distance between the interferometers, which can be large since only the light travels over this distance, not the atoms. The terrestrial experiment with two {approx}10 m atom interferometers separated by a {approx}1 km baseline can operate with strain sensitivity {approx}(10{sup -19}/{radical}(Hz)) in the 1 Hz-10 Hz band, inaccessible to LIGO, and can detect gravitational waves from solar mass binaries out to megaparsec distances. The satellite experiment with two atom interferometers separated by a {approx}1000 km baseline can probe the same frequency spectrum as LISA with comparable strain sensitivity {approx}(10{sup -20}/{radical}(Hz)). The use of ballistic atoms (instead of mirrors) as inertial test masses improves systematics coming from vibrations and acceleration noise, and significantly reduces spacecraft control requirements. We analyze the backgrounds in this configuration and discuss methods for controlling them to the required levels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗