Three-dimensional measurements of plasma parameters in an inductively coupled plasma processing chamber

Inductively coupled plasmas (ICPs) are extensively used for materials processing and microelectronics fabrication. However, their electromagnetic properties have not been fully characterized. In this regard, we have performed fully three dimensional (3D), time dependent measurements of the magnetic field, electron density, and electron temperature for an ICP sustained in argon in an industrial reactor designed for plasma etching in microelectronics fabrication. These measurements were compared to modeling results. The plasma was generated using pulsed power delivered at 2 MHz by a planar coil. The magnetic field was measured using a three axis magnetic probe at 15 366 locations throughout the plasma volume during the H-mode portion of the pulse at temporal intervals of 2 ns. A swept Langmuir probe was used to measure plasma parameters at the same locations. The plasma density measurement was calibrated with line-integrated densities obtained using a 96 GHz interferometer. During a single radio frequency (RF) cycle, the 3D current density [derived from B(r→,t)]is initially maximum just below the coil and moves downward toward the center of the chamber. Isosurfaces of current are nearly symmetric toroids. The total electric field, space charge field, and inductive electric field were derived and used to calculate the dissipated power, plasma current, and Poynting flux. Computer modeling of the experiment reproduces the phase dependent behavior. Animations showing the time dependent 3D measurements are presented in the supplementary material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced particle flux due to localized divertor MHD instability in DIII-D tokamak

An MHD mode with a frequency of <10 kHz has been identified near the inner strike point from various diagnostics, i.e., divertor Langmuir probes, magnetics sensors, and interferometers, but does not appear in the upstream and core diagnostics. This MHD mode is associated with magnetic oscillations of ≳5 G, has a long wavelength in the toroidal direction with toroidal mode number n=1, but is localized in a narrow radial region of a few cm. The mode appears when the outer strike point remains attached and the inner strike point nearly detaches, grows with increasing density, and eventually weakens and vanishes as the outer strike point detaches. This mode results in particle flux with an order of magnitude higher than the background plasmas near the inner strike point. The mode characteristics are consistent with the Current-Convective-Instability theory prediction. Initial simulations based on experimental input have found oscillations with similar frequencies but weaker amplitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interferometric two-photon-absorption spectroscopy with three entangled photons

In this work, we propose an interferometric pump-probe technique that employs three entangled photons generated by cascaded spontaneous parametric downconversion. A Mach–Zehnder interferometer made of two three-port waveguide arrays is inserted in the optical path. Two independent phases introduced to manipulate the entangled photon state serve as control parameters and can selectively excite matter pathways. Compared to two-photon-absorption of an entangled photon-pair, the three-photon signals are significantly enhanced by frequency-dispersed photon-counting detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision shock equation of state measurements for metallic fluid carbon between 15 and 20 Mbar

Diamond is an efficient ablator material to convert the energy of high-power giant lasers into ablation pressure with applications for High-Energy-Density (HED) science, planetary science, and Inertial Confinement Fusion (ICF) research at the National Ignition Facility (NIF). Unfortunately, current theoretical equation of state models cannot reproduce all the observed experimental data in the multi-megabar regime particularly relevant for HED and ICF research. New experimental data on the behavior of carbon at extreme pressures and temperatures are, therefore, essential to improve our predictive capability to design and analyze dynamic compression experiments for HED or ICF research and build improved equation of state models in the future. In this paper, we report high-precision laser-driven shock compression measurements on diamond single crystals at the Omega Laser Facility. Using ultrafast Doppler optical Velocimetry Interferometer System for Any Reflector (VISAR) to track the leading shock front and a quartz plate as an in situ reference, we obtain relative pressure-density shock equation-of-state measurements between 15 and 20 Mbar with an impedance-matching procedure. We also report shock-and-release measurements in a spherical geometry at the NIF. The new data provide tight constraints on the compressibility of warm dense carbon along the Hugoniot of full density diamond, allowing us to discriminate between existing theoretical equation-of-state models. We find that both LLNL LEOS 9061 and LANL Sesame 7835 models capture well the shock compressibility in the explored range. LANL Sesame 7835 also reproduces well the observed shock-and-release behavior of diamond near 10–20 Mbar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multidimensional four-wave-mixing spectroscopy with squeezed light

A set of nonlinear spectroscopic measurements with quantum light is presented here. It involves a strong pump with frequency ω pu and a weak probe atω pr interacting with a solid state target to generate a conjugated beam ω c =2ω pu -ω pr via nondegenerate four-wave mixing. The $\chi^{(3)}$ susceptibility can be measured by the noise spectra of the intensity difference of the squeezed beams. We discuss three spectroscopic setups based on squeezed light: first, single four-wave mixing in a single crystal; second, cascading scheme involving two crystals; third, an $\textit{SU}$(1, 1) interferometer based on two separate four-wave mixing processes. We further investigate the microscopic noise and optical losses in all three setups. Simulations are presented for silicon-vacancy color centers in diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths

Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.

Sun, K. -X. (ORCID:0000000224659235)↗

Techniques for studying materials under extreme states of high energy density compression

The properties of materials under extreme conditions of pressure and density are of key interest to a number of fields, including planetary geophysics, materials science, and inertial confinement fusion. In geophysics, the equations of state of planetary materials, such as hydrogen and iron, under ultrahigh pressure and density provide a better understanding of their formation and interior structure [Celliers et al., “Insulator-metal transition in dense fluid deuterium,” Science 361, 677–682 (2018) and Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)]. The processes of interest in these fields occur under conditions of high pressure (100 GPa–100 TPa), high temperature (>3000 K), and sometimes at high strain rates (>103 s−1) depending on the process. With the advent of high energy density (HED) facilities, such as the National Ignition Facility (NIF), Linear Coherent Light Source, Omega Laser Facility, and Z, these conditions are reachable and numerous experimental platforms have been developed. To measure compression under ultrahigh pressure, stepped targets are ramp-compressed and the sound velocity, measured by the velocity interferometer system for any reflector diagnostic technique, from which the stress-density of relevant materials is deduced at pulsed power [M. D. Knudson and M. P. Desjarlais, “High-precision shock wave measurements of deuterium: Evaluation of exchange-correlation functionals at the molecular-to-atomic transition,” Phys. Rev. Lett. 118, 035501 (2017)] and laser [Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)] facilities. To measure strength under high pressure and strain rates, experimenters measure the growth of Rayleigh–Taylor instabilities using face-on radiography [Park et al., “Grain-size-independent plastic flow at ultrahigh pressures and strain rates,” Phys. Rev. Lett. 114, 065502 (2015)]. The crystal structure of materials under high compression is measured by dynamic x-ray diffraction [Rygg et al., “X-ray diffraction at the national ignition facility,” Rev. Sci. Instrum. 91, 043902 (2020) and McBride et al., “Phase transition lowering in dynamically compressed silicon,” Nat. Phys. 15, 89–94 (2019)]. Medium range material temperatures (a few thousand degrees) can be measured by extended x-ray absorption fine structure techniques, Yaakobi et al., “Extended x-ray absorption fine structure measurements of laser-shocked V and Ti and crystal phase transformation in Ti,” Phys. Rev. Lett. 92, 095504 (2004) and Ping et al., “Solid iron compressed up to 560 GPa,” Phys. Rev. Lett. 111, 065501 (2013), whereas more extreme temperatures are measured using x-ray Thomson scattering or pyrometry. This manuscript will review the scientific motivations, experimental techniques, and the regimes that can be probed for the study of materials under extreme HED conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved optical standing-wave beam splitters for dilute Bose–Einstein condensates

Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. Here, in simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new woven composite constitutive model validated by shock wave experiments

In this paper, we present results of plate impact simulations of shock compressed woven glass fiber-reinforced plastic (GRP) performed using the Arbitrary Lagrangian–Eulerian three-dimensional finite element code. A hyperelastic large-strain-based empirical Continuum Damage Mechanics (CDM) formulation is employed to describe damage initiation and growth in the shock-compressed GRP. The model parameters calibration scheme utilizes the Velocity Interferometer System for Any Reflector normal particle velocity measurements at the free surface of the GRP target plates. The impact velocity in the experiments ranged from 8.5 to 418 m/s. The finite element model considered planar 0°/90° bidirectional plies with an individual ply thickness of 0.68 mm, stacked to reach a total laminate thickness of 6.8 mm. The anisotropic elastic strains were estimated from the experimentally determined tetragonal symmetry stiffness matrix for the GRP. The strain-based damage model captures several salient features observed in the measured free surface particle wave profiles, including the shock rise time, onset of Elastic—Elastic Cracking, and the shape of the nonlinear portion of the experimental particle velocity profiles. Furthermore, the CDM model predicts the dominant damage mode to be matrix microcracking due to shear and the associated bulk expansion (bulking) under the global compressive loading in the plate impact configuration.

42 ENGINEERING↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-inductive plasma vertical position measurement for the 1056 s discharge on EAST

Vertical position stability plays a crucial role in maintaining safe and reliable plasma operation for long-pulse fusion devices. In general, the vertical position is measured by using inductive magnetic coils installed inside the vacuum vessel; however, the integration drift effects are inherent for steady-state or long-pulse plasma operation. Further, developing a non-magnetic approach provides a fusion reactor-relevant steady-state solution that avoids the negative impact of integration drift. In this paper, we compare the non-inductively determined vertical position achieved by line-integrated interferometer and polarimeter measurements to that employing an inductive flux loop for a 1056 s discharge recently achieved on EAST (Experimental Advanced Superconducting Tokamak). Experimental results show that the non-inductive measurement is more robust than flux loops after 300 s if the integrator is not reset to suppress integrator drift. Real-time vertical position control using the non-inductive system is proposed for the next EAST experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementing Faraday effect measurement constraints into the Grad–Shafranov equilibrium fitting code EFIT

A new tool for the exploration and diagnosis of the internal magnetic field of plasmas in the DIII-D tokamak in the form of a constraint on the EFIT (Equilibrium Fitting) Grad–Shafranov code based on the Faraday-effect Radial Interferometer-Polarimeter (RIP) diagnostic is presented, including description, verification, and sample application. The physics underlying the diagnostic and its implementation into EFIT are discussed, and the results showing the verification of the model are given, and the model’s limitations are discussed. The influence of the diagnostic’s input on the resulting equilibrium parameters is characterized. Furthermore, the effect of electron density profile refinement is evaluated and found to be negligible. A sample application of the diagnostic is shown, indicating that the RIP constraint has similar effects on the equilibrium as motional Stark effect constraints do.

47 OTHER INSTRUMENTATION↗