Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Precursory Off-Fault Deformation in Restraining and Releasing Step Overs: Insights From Discrete Element Method Models

Accelerating geophysical activity is detected preceding some, but not all, large earthquakes. This observation may indicate that no precursors occur before some earthquakes, or that the instrumentation lacks the required sensitivity. Here, to aid crustal monitoring efforts, we use discrete element method models to identify the locations and styles of deformation that may provide useful information about approaching fault reactivation. We model the reactivation of two healed rough faults in a variety of step over configurations, embedded in a host rock with varying amounts of damage subject to shear velocity loading parallel to the faults. Both the fault geometry and ratio of fault to host rock strength control the amount of off-fault deformation. Consistent with field observations, models with larger steps and more preexisting host rock damage produce higher amounts of off-fault deformation. We assess the size of the continuous regions of high velocities and strains to compare the value of the precursory information of each velocity and strain component. Comparing the three components of the velocity vector suggests that the fault-parallel velocity produces the largest and most temporally continuous regions of elevated velocity. The size of these regions increases toward failure, indicating the usefulness of tracking this component. Comparing the volumetric and shear components of the three-dimensional strain tensor suggests that during most of the interseismic period, the shear strain provides more information about approaching fault slip than the volumetric strain. However, in the days and months preceding fault reactivation, both the shear and volumetric strains provide similarly valuable information.

58 GEOSCIENCES↗

Software Error Incident Categorizations in Aerospace

Since the first use of computers in space and aircraft, software errors have occurred. These errors can manifest as loss-of-life or less catastrophically. As the demand for automation increases, software in safety-critical systems should be designed to be tolerant to the most likely software faults. This paper categorizes historic aerospace software errors to determine trends of how and where automation is most likely to fail. A distinction between software producing wrong (erroneous) output versus no output (fail-silent) is introduced. Of the historical incidents analyzed, 87% were from software acting unexpectedly rather than simply stopping. Rebooting was found to be ineffective to clear erroneous behavior, and only partially effective for silent software. Errors were traced back to the software logic itself in 62% of cases, 13% within configurable data, and 25% introduced through input. Thirty percent (30%) of unexpected software behavior was caused by the absence of software and 20% was due to “unknown-unknowns”. These findings indicate that to achieve fault tolerance in safety-critical systems, backup strategies must be employed to detect and respond to erroneous software behavior beyond only fail-silent cases, and robust off-nominal testing should be performed to uncover unanticipated situations.

Software↗

Investigation of Multiple Data Streams for Gearbox Bearing Fault Prediction Through Machine-Learning Models

Operations and maintenance (O&M) cost of wind plant accounts up to 30% of total energy cost, which can be reduced through continuous monitoring and successfully detecting incipient wind turbine failures. To accomplish this, condition monitoring and predictive maintenance systems are being implemented in wind industry to support O&M decision making. A wide range of approaches for condition monitoring and fault prediction have been developed. These approaches generally use historical data of wind turbines collected by Supervisory Control and Data Acquisition (SCADA) system to identify patterns that lead to failure. These SCADA data show the overall condition of a wind turbine and can be leveraged to detect when the turbine's performance is degrading and to identify if a fault is developing. However, it becomes challenging to predict the failure of a specific wind turbine gearbox bearing, because the SCADA data are often not directly linked to the component. To bridge the gap, we have investigated features calculated from SCADA data using physics-based models and the gearbox design over the years. The damaged metric we used in the physics domain is frictional energy. Combining these physics domain variables with SCADA data as inputs to various machine learning models for gearbox bearing fault prediction, we have demonstrated the benefits of leveraging both physics and data domain models. It was an attempt to improve frictional-energy-based damage metric by adding data domain inputs, as we had learned that the frictional-energy-based damage metric alone is not sufficient to single out failed bearings from healthy. As condition monitoring data (either vibration or oil debris data) has become available at more and more wind plants, we would like to evaluate whether by adding the condition monitoring data can help further improve the performance of frictional-energy-based damage metric for gearbox bearing fault prediction. Both cases by modeling through various machine learning algorithms are discussed in this study along with some observations.

fault prediction↗

An astrometric facility for planetary detection on the Space Station

The preliminary system definition study for an Astrometric Telescope Facility (ATF) designed for the Space Station IOC is discussed, and a strawman system is designed which is found to meet the requirements for extrasolar planetary systems search and study. The strawman facility design, with a prime-focus 1.25-m aperture telescope and an f ratio of 13, was selected to minimize random and systematic errors. A basic operations approach is identified, including the approach to launch, initial on-orbit assembly and checkout, normal operations, and the response to anomolous conditions or failures. The preliminary system is designed to be fail-safe and single-fault tolerant. Mission analysis indicates that the basic viewing required for planetary detection can be accomplished in about 2/3 of the total viewing time.

Nishioka, Kenji↗

Decision Tree Based Anomaly Detection for Remedial Action Scheme in Smart Grid using PMU Data

The advanced and persistent cyber threats facing the critical infrastructure such as the smart grid are exponentially rising which require sophisticated defense strategy. Remedial Action Scheme (RAS), also known as Special Protection Scheme (SPS), relies on the interconnected cyber physical system for automated protection which is exposed to the multitude of vulnerabilities. In this paper, we propose an innovative approach to develop an Intelligent Remedial Action Scheme (IRAS) which can detect and distinguish cyber attacks from the physical disturbances in smart grid and later take smart corrective actions as required to minimize the impact on system reliability and economy. Specifically, we have proposed the decision tree based anomaly detection methodology which can distinguish between the normal tripping during power line faults and malicious tripping attack on the physical relays in the context of RAS. The classification model is developed using differential features of voltage and current phasors. Next, as a proof of concept, we have implemented and validated the proposed methodology in cyber physical environment at Iowa State's PowerCyber testbed. Finally, the proposed methodology is tested on modified IEEE 39 bus system in offline and real-time mode. Our experimental results show that the proposed method is efficient in detecting attacks and performing corrective actions within an acceptable time frame.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliable and Efficient Parallel Processing Algorithms and Architectures for Modern Signal Processing

Least-squares (LS) estimations and spectral decomposition algorithms constitute the heart of modern signal processing and communication problems. Implementations of recursive LS and spectral decomposition algorithms onto parallel processing architectures such as systolic arrays with efficient fault-tolerant schemes are the major concerns of this dissertation. There are four major results in this dissertation. First, we propose the systolic block Householder transformation with application to the recursive least-squares minimization. It is successfully implemented on a systolic array with a two-level pipelined implementation at the vector level as well as at the word level. Second, a real-time algorithm-based concurrent error detection scheme based on the residual method is proposed for the QRD RLS systolic array. The fault diagnosis, order degraded reconfiguration, and performance analysis are also considered. Third, the dynamic range, stability, error detection capability under finite-precision implementation, order degraded performance, and residual estimation under faulty situations for the QRD RLS systolic array are studied in details. Finally, we propose the use of multi-phase systolic algorithms for spectral decomposition based on the QR algorithm. Two systolic architectures, one based on triangular array and another based on rectangular array, are presented for the multiphase operations with fault-tolerant considerations. Eigenvectors and singular vectors can be easily obtained by using the multi-pase operations. Performance issues are also considered.

Liu, Kuojuey Ray↗

Learning the Low Frequency Earthquake Activity on the Central San Andreas Fault

Abstract Low frequency earthquakes (LFEs) originating below the central San Andreas Fault are associated with slow‐slip beneath the seismogenic zone within the more ductile portion of the crust. Monitoring efforts over 15 years detected >1 million LFEs. We train a gradient boosted tree model using statistical features describing the seismic waveforms to estimate the hourly LFE event count. The burst‐like LFE behavior is reproduced, while lower amplitudes are predicted during the most active periods. The hourly event counts are up to 18% greater than the catalog. The ability to continuously monitor LFE activity provides insight to when geodetic measurements of slow slip are possible, without the need for developing a computational‐intensive template‐matching catalog. Similar waveform statistical features are found between detecting LFEs and tremors, which provides additional evidence tremors are composed of LFEs. The approach extracts information contained in continuous seismic waveforms that might benefit detecting precursory signals.

58 GEOSCIENCES↗

En echelon faults reactivated by wastewater disposal near Musreau Lake, Alberta

We use machine-learning and cross-correlation techniques to enhance earthquake detectability by two magnitude units for the earthquake sequence near Musreau Lake, Alberta, which is induced by wastewater disposal. This deep catalogue reveals a series of en echelon ~N–S oriented strike-slip faults that are favourably oriented for reactivation. These faults require only ~0.6 MPa overpressure for triggering to occur. Earthquake activity occurs in bursts, or episodes; episodes restricted to the largest fault tend to have earthquakes starting near the southern end (distant from injectors) and progressing northwards (towards the injectors). While most events are concentrated along these ~N–S oriented faults, we also delineate smaller faults. Together, these findings suggest pore pressure as the triggering mechanism, where a time-dependent increase in pore pressure likely caused these faults to progressively reawaken. Analysis of the ‘next record-breaking event’, a statistical model that forecasts the sequencing of earthquake magnitudes, suggests that the next largest event would be M L ~4.3. The seismically illuminated length of the largest fault indicates potential magnitudes as large as M w 5.3.

58 GEOSCIENCES↗

Small Seismic Events in Oklahoma Detected and Located by Machine Learning–Based Models

A complete earthquake catalog is essential to understand earthquake nucleation and fault stress. Following the Gutenberg–Richter law, smaller, unseen seismic events dominate the earthquake catalog and are invaluable for revealing the fault state. The published earthquake catalogs, however, typically miss a significant number of small earthquakes. Part of the reason is due to a limitation of conventional algorithms, which can hardly extract small signals from background noise in a reliable and efficient way. To address this challenge, we utilized a machine learning method and developed new models to detect and locate seismic events. These models are efficient in processing a large amount of seismic data and extracting small seismic events. We applied our method to seismic data in Oklahoma, United States, and detected ~14 times more earthquakes compared with the standard Oklahoma Geological Survey catalog. The rich information contained in the new catalog helps better understand the induced earthquakes in Oklahoma.

58 GEOSCIENCES↗

Flight test results of the Strapdown hexad Inertial Reference Unit (SIRU). Volume 1: Flight test summary

Flight test results of the strapdown inertial reference unit (SIRU) navigation system are presented. The fault-tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance.

Hruby, R. J.↗

Flight test results of the strapdown hexad inertial reference unit (SIRU). Volume 2: Test report

Results of flight tests of the Strapdown Inertial Reference Unit (SIRU) navigation system are presented. The fault tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance. Performance shortcomings are analyzed.

Hruby, R. J.↗

Flight test results of the Strapdown hexad Inertial Reference Unit (SIRU). Volume 3: Appendices A-G

Results of flight tests of the Strapdown Inertial Reference Unit (SIRU) navigation system are presented. The fault tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance. Selected facets of the flight tests are also described in detail and include some of the following: (1) flight test plans and ground track plots; (2) navigation residual plots; (3) effects of approximations in navigation algorithms; (4) vibration spectrum of the CV-340 aircraft; and (5) modification of the statistical FDICR algorithm parameters for the flight environment.

Hruby, R. J.↗

Efficient Client Selection in Federated Learning

Federated Learning (FL) enables decentralized machine learning while preserving data privacy. This paper proposes a novel client selection framework that integrates differential privacy and fault tolerance. The adaptive client selection adjusts the number of clients based on performance and system constraints, with noise added to protect privacy. Evaluated on the UNSW-NB15 and ROAD datasets for network anomaly detection, the method improves accuracy by 7% and reduces training time by 25 % compared to baselines. Fault tolerance enhances robustness with minimal performance trade-offs.

Marfo, William [University of Texas at El Paso,Dep↗

Phasor Measurement Units Optimal Placement and Performance Limits for Fault Localization

Here, the performance limits of faults localization are investigated using synchrophasor data. The focus is on a non-trivial operating regime where the number of Phasor Measurement Unit (PMU) sensors available is insufficient to have full observability of the grid state. Proposed analysis uses the Kullback Leibler (KL) divergence between the distributions corresponding to different fault location hypotheses associated with the observation model. This analysis shows that the most likely locations are concentrated in clusters of buses more tightly connected to the actual fault site akin to graph communities. Consequently, a PMU placement strategy is derived that achieves a near-optimal resolution for localizing faults for a given number of sensors. The problem is also analyzed from the perspective of sampling a graph signal, and how the placement of the PMUs i.e. the spatial sampling pattern and the topological characteristic of the grid affect the ability to successfully localize faults. To highlight the superior performance of presented fault localization and placement algorithms, the proposed strategy is applied to a modified IEEE 34, IEEE-123 bus test cases and to data from a real distribution grid. Additionally, the detection of cyber-physical attacks is also examined where PMU data and relevant Supervisory Control and Data Acquisition (SCADA) network traffic information are compared to determine if a network breach has affected the integrity of the system information and/or operations.

42 ENGINEERING↗

Fractional Josephson current through a Luttinger liquid with topological excitations

Recently, the Majorana fermion has received great attentions due to its promising application in the fault-tolerant quantum computation. This application requires more accessible methods to detect the motion and braiding of the Majorana fermions. We use a Luttinger liquid ring to achieve this goal, where the ring geometry is nontrivial in the sense that it leads to fermion-parity-dependent topological excitations. First, we briefly review the essential physics of the Luttinger liquid and the Majorana fermion, in order to give an introduction of the general framework used in the following main work. Then, we theoretically investigated the DC Josephson effect between two topological superconductors via a Luttinger liquid ring. A low-energy effective Hamiltonian is derived to show the existence of the fractional Josephson current. Also, we find that the amplitude of the Josephson current, which is determined by the correlation function of Luttinger liquid, exhibits different behaviors in terms of the parity of Luttinger liquid due to the topological excitations. Our results suggest a possible method to detect the Majorana fermions and their tunneling process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microstructure characterization of SiC nanowires as reinforcements in composites

SiC nanowires have been rarely investigated or explored along their axial direction by transmission electron microscopy (TEM). Here we report the investigation of the cross-section microstructure of SiC nanowires by embedding them into Al matrix. Morphology of SiC nanowires was cylindrical with smooth surface or bamboo shape. Cubic (3C-SiC) and hexagonal structure (2H-SiC) phases were detected by X-ray diffraction (XRD) analysis. High density stacking faults were observed in both the cylindrical and bamboo shaped nanowires which were perpendicular to their axial direction. Selected area electron diffraction (SAED) patterns of the cylindrical and bamboo shaped SiC nanowires both in the perpendicular and parallel direction to the axial direction were equivalent in the structure. After calculation and remodeling, it has been found that the SAED patterns were composed of two sets of diffraction patterns, corresponding to 2H-SiC and 3C-SiC, respectively. Therefore, it could be concluded that the SiC nanowires are composed of a large number of small fragments that are formed by hybrid 3C-SiC and 2H-SiC structures. - Graphical abstract: Display Omitted - Highlights: • Cross-section microstructure of SiC nanowires was observed in Al composite. • Cylindrical with smooth surface or bamboo shape SiC nanowires were found. • The cylindrical and bamboo shaped SiC nanowires were equivalent in structure. • Structure of SiC nanowires was remodeled. • SiC nanowires are composed of hybrid 3C-SiC and 2H-SiC structures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

Contactless Electroluminescence Imaging for Cell and Module Characterization

Module performance can be characterized by imaging using baseline and periodic images to track defects and degradation. Both thermal images, which can be acquired during sunny operating conditions, and photoluminescence images, which could be acquired at night, can be collected without electrical connection. Electroluminescence (EL) images, which are useful to detect many types of defects such as cracks, interconnect and solder faults, and resistances, have typically required electrical connection to drive current in the cells and modules. Here, a contactless EL imaging technique is proposed, which provides an EL image without the need for electrical connection to drive current through the module. Such EL imaging has the capability to be collected at night without disruption to daytime power generation.

14 SOLAR ENERGY↗