Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

SU-E-T-300: Spatial Variations of Multiple Off-Axial Targets for a Single Isocenter SRS Treatment Plan in ExacTrac 6D Robotic Couch System

Purpose: To evaluate the spatial variations of multiple off-axial targets for a single isocenter stereotactic radiosurgery (SRS) treatment plan in ExacTrac 6D robotic couch system (BrainLab AG). Methods: Five metallic ball bearing (BB) markers were placed sparsely in 3D off-axial locations (non-coplanar) inside a skull phantom as the representatives of multiple targets mimicking multiple brain metastases. The locations of the BB markers were carefully chosen to minimize overlapping of each other in a port imaging detector plane. The skull phantom was immobilized by a frameless mask and CT scanned with a BrainLab Head and Neck Localizer using a GE Optima MDCT scanner. The CT images were exported to iPlan software (BrainLab AG) and a multiple target PTV was drawn by combining all the contours of the BBs. The margin of the MLC opening was selected as 3 mm expansion outward. Two coplanar arc beams were placed to generate a single isocenter SRS plan to treat the PTV. The arc beams were delivered using Novalis Tx system with portal imaging acquisition mode per 10% temporal resolution. The locations of the BBs were visualized and analyzed with respect to the MLC aperture in the treatment plan similar to the Winston-Lutz test. Results: All the BBs were clearly identified inside the MLC openings. The positional errors for the BBs were overall less than 1 mm along the rotational path of the two arcs. Conclusion: This study verified that the spatial deviations of multiple off-axial targets for a single isocenter SRS treatment plan is within sub-millimeter range in ExacTrac 6D robotic couch system. Accompanied with the Winston-Lutz test, this test will quality-assure the spatial accuracies of the isocenter as well as the positions of multiple off-axial targets for the SRS treatment using a single isocenter multiple target treatment plan.

60 APPLIED LIFE SCIENCES↗

SU-E-T-492: Implementing a Method for Brain Irradiation in Rats Utilizing a Commercially Available Radiosurgery Irradiator

Purpose: The purpose of the study was to implement a method for accurate rat brain irradiation using the Gamma Knife Perfexion unit. The system needed to be repeatable, efficient, and dosimetrically and spatially accurate. Methods: A platform (“rat holder”) was made such that it is attachable to the Leskell Gamma Knife G Frame. The rat holder utilizes two ear bars contacting bony anatomy and a front tooth bar to secure the rat. The rat holder fits inside of the Leskell localizer box, which utilizes fiducial markers to register with the GammaPlan planning system. This method allows for accurate, repeatable setup.A cylindrical phantom was made so that film can be placed axially in the phantom. We then acquired CT image sets of the rat holder and localizer box with both a rat and the phantom. Three treatment plans were created: a plan on the rat CT dataset, a phantom plan with the same prescription dose as the rat plan, and a phantom plan with the same delivery time as the rat plan. Results: Film analysis from the phantom showed that our setup is spatially accurate and repeatable. It is also dosimetrically accurate, with an difference between predicted and measured dose of 2.9%. Film analysis with prescription dose equal between rat and phantom plans showed a difference of 3.8%, showing that our phantom is a good representation of the rat for dosimetry purposes, allowing for +/- 3mm diameter variation. Film analysis with treatment time equal showed an error of 2.6%, which means we can deliver a prescription dose within 3% accuracy. Conclusion: Our method for irradiation of rat brain has been shown to be repeatable, efficient, and accurate, both dosimetrically and spatially. We can treat a large number of rats efficiently while delivering prescription doses within 3% at millimeter level accuracy.

60 APPLIED LIFE SCIENCES↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-BRA-02: An Efficient Atlas-Based Synthetic CT Generation Method

Purpose: A major obstacle for MR-only radiotherapy is the need to generate an accurate synthetic CT (sCT) from MR image(s) of a patient for the purposes of dose calculation and DRR generation. We propose here an accurate and efficient atlas-based sCT generation method, which has a computation speed largely independent of the number of atlases used. Methods: Atlas-based sCT generation requires a set of atlases with co-registered CT and MR images. Unlike existing methods that align each atlas to the new patient independently, we first create an average atlas and pre-align every atlas to the average atlas space. When a new patient arrives, we compute only one deformable image registration to align the patient MR image to the average atlas, which indirectly aligns the patient to all pre-aligned atlases. A patch-based non-local weighted fusion is performed in the average atlas space to generate the sCT for the patient, which is then warped back to the original patient space. We further adapt a PatchMatch algorithm that can quickly find top matches between patches of the patient image and all atlas images, which makes the patch fusion step also independent of the number of atlases used. Results: Nineteen brain tumour patients with both CT and T1-weighted MR images are used as testing data and a leave-one-out validation is performed. Each sCT generated is compared against the original CT image of the same patient on a voxel-by-voxel basis. The proposed method produces a mean absolute error (MAE) of 98.6±26.9 HU overall. The accuracy is comparable with a conventional implementation scheme, but the computation time is reduced from over an hour to four minutes. Conclusion: An average atlas space patch fusion approach can produce highly accurate sCT estimations very efficiently. Further validation on dose computation accuracy and using a larger patient cohort is warranted. The author is a full time employee of Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

An Advanced Integrated Diffusion/Transport Method for the Design, Analysis and Optimization of the Very-High-Temperature Reactors

The main objective of this research is to develop an integrated diffusion/transport (IDT) method to substantially improve the accuracy of nodal diffusion methods for the design and analysis of Very High Temperature Reactors (VHTR). Because of the presence of control rods in the reflector regions in the Pebble Bed Reactor (PBR-VHTR), traditional nodal diffusion methods do not accurately model these regions, within which diffusion theory breaks down in the vicinity of high neutron absorption and steep flux gradients. The IDT method uses a local transport solver based on a new incident flux response expansion method in the controlled nodes. Diffusion theory is used in the rest of the core. This approach improves the accuracy of the core solution by generating transport solutions of controlled nodes while maintaining computational efficiency by using diffusion solutions in nodes where such a treatment is sufficient. The transport method is initially developed and coupled to the reformulated 3-D nodal diffusion model in the CYNOD code for PBR core design and fuel cycle analysis. This method is also extended to the prismatic VHTR. The new method accurately captures transport effects in highly heterogeneous regions with steep flux gradients. The calculations of these nodes with transport theory avoid errors associated with spatial homogenization commonly used in diffusion methods in reactor core simulators

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron thermal transport analysis in Tokamak a Configuration Variable

A Tokamak a Configuration Variable (TCV) [G. Tonetti, A. Heym, F. Hofmann et al., in Proceedings of the 16th Symposium on Fusion Technology, London, U.K., edited by R. Hemsworth (North-Holland, Amsterdam, 1991), p. 587] plasma with high power density (up to 8 MW/m{sup 3}) core deposited electron cyclotron resonance heating at significant plasma densities ({<=}7x10{sup 19} m{sup -3}) is analyzed for the electron thermal transport. The discharge distinguishes itself as it has four distinct high confinement mode (H-mode) phases. An Ohmic H-mode with type III edge localized modes (ELMs), which turns into a type I ELMy H-mode when the ECRH is switched on. The ELMs then vanish, which gives rise to a quasistationary ELM-free H-mode. This ELM-free phase can be divided into two, one without magnetohydrodynamics (MHD) and one with. The MHD mode in the latter case causes the confinement to drop by {approx}15%. For all four phases both large-scale trapped electron (TEM) and ion temperature gradient (ITG) modes and small-scale electron temperature gradient (ETG) modes are analyzed. The analytical TEM formulas have difficulty in explaining both the magnitude and the radial profile of the electron thermal flux. Collisionality governs the drive of the TEM, which for the discharge in question implies it can be driven by either the temperature or density gradient. The TEM response function is derived and it is shown to be relatively small and to have sharp resonances in its energy dependence. The ETG turbulence, predicted by the Institute for Fusion Studies electron gyrofluid code, is on the other hand driven solely by the electron temperature gradient. Both trapped and passing electrons add to the ETG instability and turbulent thermal flux. For easy comparison of the results of the above approaches and also with the Weiland model, a dimensionless error measure, the so-called average relative variance is introduced. According to this method the ETG model explains 70% of the variation in the electron heat diffusivity whereas the predictive capabilities of the TEM-ITG models are poor. These results for TCV support the conclusion that the ETG model is able to explain a wide range of anomalous electron transport data, in addition to existing evidence from ASDEX [F. Ryter, F. Leuterer, G. Pereverzev, H.-U. Fahrbach, J. Stober, W. Suttrop, and the ASDEX Upgrade Team, Phys. Rev. Lett. 86, 2325 (2001)], Tore Supra [G. T. Hoang, W. Horton, C. Bourdelle, B. Hu, X. Garbet, and M. Ottaviani, Phys. Plasmas 10, 405 (2003)] and the Frascati Tokamak Upgrade [A. Jacchia, F. D. Luca, S. Cirant, C. Sozzi, G. Bracco, A. Brushi, P. Buratti, S. Podda, and O. Tudisco, Nucl. Fusion 42, 1116 (2002)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy

Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. Conclusions: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Preoperative Pazopanib in High-Risk Soft Tissue Sarcoma: Phase II Window-of Opportunity Study of the German Interdisciplinary Sarcoma Group (NOPASS/GISG-04)

Background: Preoperative devascularization might improve local control and thus the outcome of patients with soft tissue sarcoma (STS). The multikinase inhibitor pazopanib has antiangiogenic effects and is approved for treating metastatic STS. We conducted a trial of preoperative pazopanib therapy in high-risk STS. Methods: This single-arm, phase II trial included patients with resectable, non-metastatic, treatment-naïve, high-risk STS. Patients received pazopanib 800 mg daily while waiting for surgery (21-day ‘window of opportunity’). The primary endpoint was metabolic response rate (MRR; proportion of patients with ≥ 50% reduction of mean standardized uptake value [SUV{sub mean}] in post- vs. pretreatment fluorodeoxyglucose–positron emission tomography/computed tomography [FDG-PET-CT]). Planned sample size was 35 patients (type I error, 5%; type II error, 20%). A translational substudy explored associations between response and concentration of circulating angiogenic factors. Results: Futility analysis was performed after 21 patients (11 female, mean age 67 years; liposarcoma n = 15); 17/21 patients were evaluable for the primary endpoint. The MRR was 1/17 (5.9%, 95% confidence interval < 0.01–0.29). Mean change in SUV{sub mean} of post- versus pretreatment PET was a 6% decrease (range 65% decrease to 34% increase); 7/21 (33.3%) patients had 12 grade 3/4 toxicities, and 19/21 (95.2%) patients were resected (all R0). One (4.8%) patient suffered a grade 4 postoperative complication (anastomotic leakage). Circulating endothelial progenitor cells, soluble vascular endothelial growth factor, and angiopoietin-2 concentrations showed no relevant changes during treatment. Conclusions: Although this study showed that preoperative pazopanib is not effective for unselected high-risk STS patients, relevant treatment effects were observed in a single patient. Future research needs to better define subgroups potentially benefiting from preoperative pazopanib treatment. ClinicalTrials.gov identifier: NCT01543802.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safeguards Envelope: The First Steps

The possibility exists for real time accountancy and assay of nuclear materials as they move through a reprocessing facility. This project aims to establish working parameters and local figures of merit to identify possible diversion in real time with minimal operational impact. Factors such as pH, NOX gas concentration, flow speeds and radiation fields are rarely taken into account in safeguards methodologies and will be included to increase the confidence of location and assay of nuclear materials. An adaptable, real data model is being created of the contactors of the Advanced Fuel Cycle Facility and will be analyzed using the appropriate modeling codes. This model will then be subjected to three, diversion scenarios and a figure of merit methodology will be utilized to create the operational parameters under which these diversion scenarios would be detected. This analysis for figure of merit methodology will include statistical fluctuations, operator error, and a rudimentary analysis of transient conditions. The long term goal of the project includes expansion universally over the plant, methods of detection without requiring access to proprietary information, and an evaluation of the requirements for future figure of merit methodologies.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Asymptotic safety on the lattice: The nonlinear O(N) sigma model

We study the non-perturbative renormalization group flow of the nonlinear O(N) sigma model in two and three spacetime dimensions using a scheme that combines an effective local Hybrid Monte Carlo update routine, blockspin transformations and a Monte Carlo demon method. In two dimensions our results verify perturbative renormalizability. In three dimensions, we determine the flow diagram of the theory for various N and different truncations and find a non-trivial fixed point, which indicates non-perturbative renormalizability. It is related to the well-studied phase transition of the O(N) universality class and characterizes the continuum physics of the model. We compare the obtained renormalization group flows with recent investigations by means of the Functional Renormalization Group. - Highlights: • We compute the global flow diagram from lattice simulations. • Truncation of the effective action may lead to artificial fixed points. • Our optimization scheme effectively reduces truncation errors. • The Wilson–Fisher fixed point is identified as a non-trivial UV fixed point. • Asymptotic safety is realized for the 3D nonlinear sigma model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of different methods for measuring thermal conductivities

Two different methods for the measurement of the thermal conductivity have been applied to a glass (borosilicate) bulk sample. The first method was in the steady-state using an arrangement of gold wires on the sample to create a thermal gradient and to measure the temperatures locally. This allows one to calculate the in-plane thermal conductivity of the sample. The same wire arrangement was also used for a 3{omega}-measurement of the direction-independent bulk thermal conductivity. The 3{omega}-approach is based on periodical heating and a frequency dependent analysis of the temperature response. The results of both methods are in good agreement with each other for this isotropic material, if thermal and radiative losses are accounted for. Our results demonstrate that especially in the case of thin-film measurements, finite element analysis has to be applied to correct for heat losses due to geometry and radiation. In this fashion, the wire positions can be optimized in order to minimize measurement errors.

36 MATERIALS SCIENCE↗

DGDFT: A massively parallel method for large scale density functional theory calculations

We describe a massively parallel implementation of the recently developed discontinuous Galerkin density functional theory (DGDFT) method, for efficient large-scale Kohn-Sham DFT based electronic structure calculations. The DGDFT method uses adaptive local basis (ALB) functions generated on-the-fly during the self-consistent field iteration to represent the solution to the Kohn-Sham equations. The use of the ALB set provides a systematic way to improve the accuracy of the approximation. By using the pole expansion and selected inversion technique to compute electron density, energy, and atomic forces, we can make the computational complexity of DGDFT scale at most quadratically with respect to the number of electrons for both insulating and metallic systems. We show that for the two-dimensional (2D) phosphorene systems studied here, using 37 basis functions per atom allows us to reach an accuracy level of 1.3 × 10{sup −4} Hartree/atom in terms of the error of energy and 6.2 × 10{sup −4} Hartree/bohr in terms of the error of atomic force, respectively. DGDFT can achieve 80% parallel efficiency on 128,000 high performance computing cores when it is used to study the electronic structure of 2D phosphorene systems with 3500-14 000 atoms. This high parallel efficiency results from a two-level parallelization scheme that we will describe in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

No evidence for a dependence of the mass-size relation of early-type galaxies on environment in the local universe

The early-type galaxy (ETG) mass-size relation has largely been studied to understand how these galaxies assembled their mass. One key observational result of the last years is that massive galaxies increased their size by a factor of a few at fixed stellar mass from z ∼ 2. Hierarchical models favor minor mergers as a plausible driver of this size growth. Some of these models predict a significant environmental dependence in the sense that galaxies residing in more massive halos tend to be larger than galaxies in lower mass halos, at fixed stellar mass and redshift. At present, observational results of this environmental dependence are contradictory. In this paper we revisit this issue in the local universe, by investigating how the sizes of massive ETGs depend on a large-scale environment using an updated and accurate sample of ETGs in different environments—field, group, and clusters—from the Sloan Digital Sky Survey DR7. Our analysis does not show any significant environmental dependence of the sizes of central and satellite ETGs at fixed stellar mass at z ∼ 0. The size-mass relation of early-type galaxies at z ∼ 0 seems to be universal, i.e., independent of the mass of the host halo and of the position of the galaxy in that halo (central or satellite). The result is robust to different galaxy selections based on star formation, morphology, or central density. Considering our observational errors and the size of the sample, any size ratio larger than 30%-40% between massive galaxies (log(M {sub *}/M {sub ☉}) > 11) living in clusters and in the field can be ruled out at 3σ level.

79 ASTRONOMY AND ASTROPHYSICS↗

The need for accurate redshifts in supernova cosmology

Recent papers have shown that a small systematic redshift shift (Δ z ∼ 10{sup −5}) in measurements of type Ia supernovae can cause a significant bias (∼1%) in the recovery of cosmological parameters. Such a redshift shift could be caused, for example, by a gravitational redshift due to the density of our local environment. The sensitivity of supernova data to redshift shifts means supernovae make excellent probes of inhomogeneities. We therefore invert the analysis, and try to diagnose the nature of our local gravitational environment by fitting for Δ z as an extra free parameter alongside the usual cosmological parameters. Using the Joint Light-curve SN Ia dataset we find the best fit includes a systematic redshift shift of Δ z = (2.6{sup +2.7}{sub −2.8}) × 10{sup −4}. This is a larger shift than would be expected due to gravitational redshifts in a standard Λ-Cold Dark Matter universe (though still consistent with zero), and would correspond to a monopole Doppler shift of about 100 km s{sup −1} moving away from the Milky-Way. However, since most supernova measurements are made to a redshift precision of no better than 10{sup −3}, it is possible that a systematic error smaller than the statistical error remains in the data and is responsible for the shift; or that it is an insignificant statistical fluctuation. We find that when Δ z is included as a free parameter while fitting to the JLA SN Ia data, the constraints on the matter density shifts to Ω {sub m} = 0.313{sup +0.042}{sub −0.040}, bringing it into better agreement with the CMB cosmological parameter constraints from Planck. A positive Δ z ∼ 2.6×10{sup −4} would also cause us to overestimate the supernova measurement of Hubble's constant by Δ H {sub 0} ∼ 1 kms{sup −1}Mpc{sup −1}. However this overestimation should diminish as one increases the low-redshift cutoff, and this is not seen in the most recent data.

79 ASTRONOMY AND ASTROPHYSICS↗

Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array

Purpose: Transcranial focused ultrasound (FUS) shows great promise for a range of therapeutic applications in the brain. Current clinical investigations rely on the use of magnetic resonance imaging (MRI) to monitor treatments and for the registration of preoperative computed tomography (CT)-data to the MR images at the time of treatment to correct the sound aberrations caused by the skull. For some applications, MRI is not an appropriate choice for therapy monitoring and its cost may limit the accessibility of these treatments. An alternative approach, using high frequency ultrasound measurements to localize the skull surface and register CT data to the ultrasound treatment space, for the purposes of skull-related phase aberration correction and treatment targeting, has been developed. Methods: A prototype high frequency, hemispherical sparse array was fabricated. Pulse-echo measurements of the surface of five ex vivo human skulls were made, and the CT datasets of each skull were obtained. The acoustic data were used to rigidly register the CT-derived skull surface to the treatment space. The ultrasound-based registrations of the CT datasets were compared to the gold-standard landmark-based registrations. Results: The results show on an average sub-millimeter (0.9 ± 0.2 mm) displacement and subdegree (0.8° ± 0.4°) rotation registration errors. Numerical simulations predict that registration errors on this scale will result in a mean targeting error of 1.0 ± 0.2 mm and reduction in focal pressure of 1.0% ± 0.6% when targeting a midbrain structure (e.g., hippocampus) using a commercially available low-frequency brain prototype device (InSightec, 230 kHz brain system). Conclusions: If combined with ultrasound-based treatment monitoring techniques, this registration method could allow for the development of a low-cost transcranial FUS treatment platform to make this technology more widely available.

60 APPLIED LIFE SCIENCES↗

A machine-learning approach to measuring the escape of ionizing radiation from galaxies in the reionization epoch

Recent observations of galaxies at z≳7, along with the low value of the electron scattering optical depth measured by the Planck mission, make galaxies plausible as dominant sources of ionizing photons during the epoch of reionization. However, scenarios of galaxy-driven reionization hinge on the assumption that the average escape fraction of ionizing photons is significantly higher for galaxies in the reionization epoch than in the local universe. The NIRSpec instrument on the James Webb Space Telescope (JWST) will enable spectroscopic observations of large samples of reionization-epoch galaxies. While the leakage of ionizing photons will not be directly measurable from these spectra, the leakage is predicted to have an indirect effect on the spectral slope and the strength of nebular emission lines in the rest-frame ultraviolet and optical. Here, we apply a machine learning technique known as lasso regression on mock JWST/NIRSpec observations of simulated z = 7 galaxies in order to obtain a model that can predict the escape fraction from JWST/NIRSpec data. Barring systematic biases in the simulated spectra, our method is able to retrieve the escape fraction with a mean absolute error of Δf{sub esc}≈0.12 for spectra with signal-to-noise ratio ≈ 5 at a rest-frame wavelength of 1500 Å for our fiducial simulation. This prediction accuracy represents a significant improvement over previous similar approaches.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY ABSORPTION SPECTROSCOPY OF YB3+-DOPED OPTICAL FIBERS

Optical fibers doped with Ytterbium-3+ have become increasingly common in fiber lasers and amplifiers. Yb-doped fibers provide the capability to produce high power and short pulses at specific wavelengths, resulting in highly effective gain media. However, little is known about the local structure, distribution, and chemical coordination of Yb3+ in the fibers. This information is necessary to improve the manufacturing process and optical qualities of the fibers. Five fibers doped with Yb3+ were studied using Extended X-ray Absorption Fine Structure (EXAFS) spectroscopy and X-ray Absorption Near Edge Spectroscopy (XANES), in addition to Yb3+ mapping. The Yb3+ distribution in each fiber core was mapped with 2D and 1D intensity scans, which measured X-ray fluorescence over the scan areas. Two of the five fibers examined showed highly irregular Yb3+ distributions in the core center. In four of the five fibers Yb3+ was detected outside of the given fiber core dimensions, suggesting possible Yb3+ diffusion from the core, manufacturing error, or both. X-ray absorption spectroscopy (XAS) analysis has so far proven inconclusive, but did show that the fibers had differing EXAFS spectra. The Yb3+ distribution mapping proved highly useful, but additional modeling and examination of fiber preforms must be conducted to improve XAS analysis, which has been shown to have great potential for the study of similar optical fi bers.

Citron, Robert↗

Fracton models from product codes

We explore a deep connection between fracton order and product codes. In particular, we propose and analyze conditions on classical seed codes which lead to fracton order in the resulting quantum product codes. Depending on the properties of the input codes, product codes can realize either Type-I or Type-II fracton models, in both nonlocal and local constructions. For the nonlocal case, we show that a recently proposed model of lineons on nonlocal graphs can be obtained as a hypergraph product code. Interestingly, constrained mobility in this model arises only from energy barriers associated with the graph. For the local case, we introduce a novel type of classical LDPC code defined on a planar aperiodic tiling. By considering the specific example of the pinwheel tiling, we demonstrate the systematic construction of local Type-I and Type-II fracton models as product codes. Our work establishes product codes as a natural setting for exploring fracton order.

Fractons↗