Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Design of a Particle Shadow-graph Velocimetry and Size (PSVS) System to Determine Particle Size and Density Distributions in Hanford Nuclear Tank Wastes - 12280

Accurate particle size and density distributions for nuclear tank waste materials are essential information that helps determine the engineering requirements for a host of waste management unit operations (e.g., tank mixing, pipeline transport, and filtration). The most prevalent approach for determining particle size and density distribution is highly laborious and involves identifying individual particles using scanning electron microscope/x-ray diffraction and then acquiring the density of the materials from the technical literature. Other methods simply approximate individual particle densities by assuming chemical composition, rather than obtaining actual measurements of particle density. To overcome these limitations, a Particle Shadow-graph Velocimetry and Size (PSVS) system has been designed to simultaneously obtain particle size and density distributions for a broad range of Hanford tank waste materials existing as both individual particles and agglomerates. The PSVS system uses optical hardware, a temperature-controlled settling column, and particle introduction chamber to accurately and reproducibly obtain images of settling particles. Image analysis software provides a highly accurate determination of both particle terminal velocity and equivalent spherical particle diameter. The particle density is then calculated from Newton's terminal settling theory. The PSVS system was designed to accurately image particle/agglomerate sizes between 10 and 1000 μm and particle/agglomerate densities ranging from 1.4 to 11.5 g/cm{sup 3}, where the maximum terminal velocity does not exceed 10 cm/s. Preliminary testing was completed with standard materials and results were in good agreement with terminal settling theory. Recent results of this method development are presented, as well as experimental design. The primary goal of these PSVS system tests was to obtain accurate and reproducible particle size and velocity measurements to estimate particle densities within 20 percent of direct measured density values. The average percent error observed in particle densities was 4.8, 8.2, and 25.8 percent for S1D3 (high-density soda-lime glass), S3D4 (zirconia), and S1D2 (soda-lime glass) beads, respectively. The maximum measured particle density error observed was 14.5, 21.0, and 58.4, for S1D3, S3D4, and S1D2 beads, respectively. Multiple sources of error can exist that contribute to inaccurate estimates of particle density using the PSVS approach. Two significant influences observed were thermal convective currents in the settling column fluid and non-spherical (irregular) particle shapes in the standard test materials. Experimental results using buoyant beads suggest thermal convective currents can influence the movement of settling particles as much as 4 mm/s. These thermal convective currents are clearly a significant concern for smaller and less-dense particles/agglomerates which have terminal velocities of the same magnitude. Significant effort went into the design and fabrication of a thermal control system for the PSVS settling column. However, small temperature variations (<0.3 deg. C) are difficult to prevent and measure accurately. Therefore, although designing the thermal control system was necessary, it is not considered the only solution to minimize error due to thermal convective currents. The use of small diameter (10 to 27 μm) polyethylene buoyant beads (in low concentrations) during actual settling experiments may be necessary to provide insight into particle-particle interactions and fluid velocity correction factors to account for potential influences from thermal convective currents. Future testing will incorporate the buoyant beads into the analysis technique when the suspension fluid is chemically compatible. The use of the Newton's law to calculate particle/agglomerate densities assumes spherical particle shapes. As the actual particle/agglomerates diverge from spherical, the margin of error increases. The selection of high quality (in density and shape) monodispersed particle standards was a direct attempt to reduce the uncertainties associated with non-spherical or irregular particles and to only observe the PSVS method and analysis error. While investigating the source of data scatter for the S1D3 bead (nominal 700 μm) standard, significant irregular particles where discovered. Yet, a subsequent investigation into the S3D4 bead standard was also conducted and it was determined that 60 percent of the particles had a 0.9 to 0.8 centricity, 32 percent were between 0.8 and 0.7, only 7 percent were between 1.0 and 0.9, and the remaining 1 percent of the particles had centricities between 0.7 and 0.6. Contrast this with the S1D3 bead standard, where 100 percent of particles had centricities between 0.95 and 0.98, upon applying the centricity filter. The influence of the non-spherical shape of the S3D4 bead standard is evident when comparing a 3.9 percent average density error for S1D3 glass bead standard with an 8.3 percent average density error for the S3D4 bead standard. Model corrections for non-spherical shape must be implemented to account for these measurement errors during future method validation and system performance assessments. In addition, further work is needed to resolve the higher than expected velocities for the smaller S1D2 particles. Initial measurements conducted with buoyant beads as fluid velocity tracers indicate that fluid velocities can be subtracted from the increased particle velocities to determine the particle terminal velocity, regardless of the surrounding fluid velocity. However, this approach is in its infancy and will need to be carefully and methodically validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Fermi–Löwdin self-interaction correction for ionization energies of organic molecules

(Semi)-local density functional approximations (DFAs) suffer from self-interaction error (SIE). When the first ionization energy (IE) is computed as the negative of the highest occupied orbital (HO) eigenvalue, DFAs notoriously underestimate them compared to quasi-particle calculations. Here, the inaccuracy for the HO is attributed to SIE inherent in DFAs. We assessed the IE based on Perdew-Zunger self-interaction correction on 14 small to moderate-sized organic molecules relevant in organic electronics and polymer donor materials. Though self-interaction corrected DFAs were found to significantly improve the IE relative to the uncorrected DFAs, they overestimate. However, when the self-interaction correction is interiorly scaled using a function of the iso-orbital indicator zs , only the regions where SIE is significant get a correction. We discuss these approaches and show how these methods significantly improve the description of the HO eigenvalue for the organic molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bias correcting regional scale Earth system model projections: novel approach using empirical mode decomposition

Bias correction is a crucial step in using Earth system model outputs for assessments, as it adjusts systematic errors by comparing the model to observations. However, standard methods – ranging from mean-based linear scaling to distribution-based quantile mapping typically treat bias correction as a single-scale process, overlooking the fact that biases can manifest differently across daily, seasonal, and annual timescales. In this study, we propose a novel, timescale-aware bias-correction approach built on Empirical Mode Decomposition. By decomposing the meteorological signal into multiple oscillatory components and aggregating them to represent distinct timescales, we apply targeted corrections to each component, thereby preserving both short- and long-term structure in the data. Experimental illustrations show that the timescale-aware EMDBC framework matches the performance of conventional quantile-delta mapping (QDM) at the native daily scale and achieves progressively larger bias reductions at bi-weekly, seasonal, and annual scales. As a result, the proposed approach offers a more robust path to accurate and reliable Earth system projections, strengthening their utility for resilience and adaptation planning.

Ganguli, Arkaprabha [Argonne National Laboratory (↗

Development of an ultraprecise glue-free bimorph deformable mirror with a length of 460 mm

Lead zirconate titanate (PZT) bimorph mirrors are essential for performing multiple functions, such as beam shaping, wavefront correction, and dynamic focusing with adjustable beam sizes. They typically consist of a mirror substrate with PZT electrodes bonded to the substrate using a thin epoxy film. However, glue-bonded PZT mirrors exhibit low reproducibility in measurement results. One source of this variability is water absorption by the substrate’s epoxy adhesive during wet fabrication processes, such as elastic emission machining (EEM), which leads to swelling and deformation. Additionally, longer deformable bimorph mirrors require larger PZT electrodes, further complicating their design and fabrication, particularly during bonding and ultraprecise metrology. To address these challenges, silver nanoparticles were employed to bond PZT elements to the silicon (Si) mirror, eliminating the need for epoxy glue. Here, in this study, we developed an inorganic-glue-free PZT bimorph mirror with a length of 460 mm and 28 channels. The glue-free bonding method successfully ensured the high reproducibility of measurements after water immersion. This approach resulted in a shape error of only 0.41 nm root mean square after the figure correction process using an ultraprecise EEM process. Scanning acoustic tomography and basic response function tests confirmed the success of the bonding process, showing no critical voids. Furthermore, the shape changes induced by applying voltages to the PZT electrodes closely matched predictions obtained from simulations. These results demonstrate the reliability and precision of the proposed glue-free bonding technique, paving the way for improved performance of new PZT bimorph mirrors.

Ichii, Yoshio [SLAC National Accelerator Laborator↗

Fetal progenitor cell transplantation treats methylmalonic aciduria in a mouse model

Highlights: Black-Right-Pointing-Pointer Fetal cells were transplanted into a methylmalonic acid mouse model. Black-Right-Pointing-Pointer Cell engraftment was detected in liver, spleen and bone marrow. Black-Right-Pointing-Pointer Biochemical disease correction was measured in blood samples. Black-Right-Pointing-Pointer A double dose of 5 million cells (1 week apart) proved more effective. Black-Right-Pointing-Pointer Higher levels of engraftment may be required for greater disease correction. -- Abstract: Methylmalonic aciduria is a rare disorder caused by an inborn error of organic acid metabolism. Current treatment options are limited and generally focus on disease management. We aimed to investigate the use of fetal progenitor cells to treat this disorder using a mouse model with an intermediate form of methylmalonic aciduria. Fetal liver cells were isolated from healthy fetuses at embryonic day 15-17 and intravenously transplanted into sub-lethally irradiated mice. Liver donor cell engraftment was determined by PCR. Disease correction was monitored by urine and blood methylmalonic acid concentration and weight change. Initial studies indicated that pre-transplantation sub-lethal irradiation followed by transplantation with 5 million cells were suitable. We found that a double dose of 5 million cells (1 week apart) provided a more effective treatment. Donor cell liver engraftment of up to 5% was measured. Disease correction, as defined by a decrease in blood methylmalonic acid concentration, was effected in methylmalonic acid mice transplanted with a double dose of cells and who showed donor cell liver engraftment. Mean plasma methylmalonic acid concentration decreased from 810 {+-} 156 (sham transplanted) to 338 {+-} 157 {mu}mol/L (double dose of 5 million cells) while mean blood C3 carnitine concentration decreased from 20.5 {+-} 4 (sham transplanted) to 5.3 {+-} 1.9 {mu}mol/L (double dose of 5 million cells). In conclusion, higher levels of engraftment may be required for greater disease correction; however these studies show promising results for cell transplantation biochemical correction of a metabolic disorder.

60 APPLIED LIFE SCIENCES↗

Quality-Controlled Upper-Air Sounding Dataset for DYNAMO/CINDY/AMIE: Development and Corrections

The upper-air sounding network for DYNAMO (Dynamics of the Madden-Julian Oscillation or MJO) has provided an unprecedented set of observations for studying the MJO over the Indian Ocean (IO) where coupling of this oscillation with deep convection first occurs. With 72 sounding sites and dropsonde data from 13 aircraft mission, the sonde network covers the tropics from Eastern African to the West Pacific. In total nearly 26,000 sondes were collected from this network during the experiment’s 6-month extended observing period (from October 2011 to March 2012). Slightly more than half of the sondes, collected from 33 sites, are at high vertical resolution. Rigorous post-field phase processing of the sonde data included several levels of quality checks and a variety of corrections which address a number of issues (e.g., daytime dry bias, baseline surface data errors, ship deck-heating effects, artificial dry spikes in slow ascent sondes). Because of the importance of an accurate description of the moisture field in meeting the scientific goals of the experiments, particular attention is given to humidity correction and its validation. The humidity corrections, though small relative to some previous field campaigns, produced high fidelity moisture analyses in which sonde precipitable water compared well with independent estimates. An assessment of model operational analyses moisture using corrected sonde data shows an overall good agreement with the exception at upper-levels where model moisture and clouds are more abundant than the sounding data would indicate.

dataset↗

STUDYING THE WARM HOT INTERGALACTIC MEDIUM WITH GAMMA-RAY BURSTS

We assess the possibility of detecting and characterizing the physical state of the missing baryons at low redshift by analyzing the X-ray absorption spectra of the gamma-ray burst (GRB) afterglows, measured by a microcalorimeter-based detector with 3 eV resolution and 1000 cm{sup 2} effective area and capable of fast repointing, similar to that on board of the recently proposed X-ray satellites EDGE and XENIA. For this purpose we have analyzed mock absorption spectra extracted from different hydrodynamical simulations used to model the properties of the warm hot intergalactic medium (WHIM). These models predict the correct abundance of O VI absorption lines observed in UV and satisfy current X-ray constraints. According to these models space missions such as EDGE and XENIA should be able to detect {approx}60 WHIM absorbers per year through the O VII line. About 45% of these have at least two more detectable lines in addition to O VII that can be used to determine the density and the temperature of the gas. Systematic errors in the estimates of the gas density and temperature can be corrected for in a robust, largely model-independent fashion. The analysis of the GRB absorption spectra collected in three years would also allow to measure the cosmic mass density of the WHIM with {approx}15% accuracy, although this estimate depends on the WHIM model. Our results suggest that GRBs represent a valid, if not preferable, alternative to active galactic nuclei to study the WHIM in absorption. The analysis of the absorption spectra nicely complements the study of the WHIM in emission that the spectrometer proposed for EDGE and XENIA would be able to carry out thanks to its high sensitivity and large field of view.

79 ASTRONOMY AND ASTROPHYSICS↗

Pipelining RDP Data to the "Taxomatic" (Final Report)

This project builds on the results of previously funded research by integrating data and software that had been previously used in building resources used in the preparation of Bergey's Manual of Systematic Bacteriology, 2 nd Edition (Volumes 1 & 2A-C) and the Ribosomal Database Project-II (RDP-II) so as to both enhance the value of the data and create a pipeline approach to keeping the data current. Earlier, we demonstrated the value of using exploratory data analysis (EDA) to visualize large sets of sequence data (notably SSU rRNA gene sequences used in constructing a comprehensive phylogeny of prokaryotes. While the Self- Organizing Self-Correcting Classification (SOSCC) algorithms we developed were computationally efficient and useful for unraveling problems within the underlying data (e.g., identification of annotation errors, detection of unresolved synonymies, taxonomic and nomenclatural errors), bottlenecks at the preprocessing stage limited deployment of our applications as tools for end-users. To overcome the bottlenecks (which included hand alignment and computation of large matrices of pair-wise evolutionary distances), we proposed building a data pipeline between the "Taxomatic" application and RDP-II. The objectives were to accelerate the production and distribution of the updated versions of the prokaryotic taxonomy in lock-step with publication of new taxa and rearrangement of existing taxa, and to distribute these data more readily with the RDP-II and and other stakeholders in the community. A related goal of the current project is to deploy our visualization techniques as an interactive web application by which end-users can view manipulate, and select datasets of particular interest based upon phylogenetic and genomic information, access sequence data, and ultimately the scientific literature where the original observations were made and those that build on the original observations. The Taxomatic is a web-based tool to visualize distance matrices. The tool accepts raw distance matrices or aligned sequence information as data sources. When sequence information is provided the distance matrix is computed using the uncorrected distance model. Users can upload files to the Taxomatic website or sequences can be submitted by a SOAP service. This SOAP service is used by RDP to streamline Taxomatic use with RDP data. In addition to supplying source information, users can either supply their own taxonomic information by uploading it in XML, retrieve data taxonomic information from the RDP using either RDP or Genbank identifiers as source data, with or without classification by the RDP Classifier web service, or completely omit taxonomic data. In the latter case, the input distance matrix can be viewed in the order in which it was loaded.

59 BASIC BIOLOGICAL SCIENCES↗

Improvements in the orbitalwise scaling down of Perdew–Zunger self-interaction correction in many-electron regions

The Perdew-Zunger (PZ) method offers a way to remove the self-interaction (SI) error from density functional approximations on an orbital by orbital basis. The PZ method provides significant improvements for the properties such as barrier heights or dissociation energies but results in over-correcting the properties well described by SI-uncorrected semi-local functional. One cure to rectify the over-correcting tendency is to scale down the magnitude of SI-correction of each orbital in the many electron region. We have implemented the orbitalwise scaled down SI-correction (OSIC) scheme of Vydrov et al. [J. Chem. Phys. 124, 094108 (2006)] using the Fermi-L owdin SI-correction method. After validating the OSIC implementation with previously reported OSICLSDA results, we examine its performance with the most successful non-empirical SCAN meta-GGA functional. Using different forms of scaling factors to identify one-electron regions, we assess the performance of OSIC-SCAN for a wide range of properties: total energies, ionization potentials and electron affinities for atoms, atomization energies, dissociation and reaction energies, and reaction barrier heights of molecules. Our results show that OSIC-SCAN provides superior results than the previously reported OSIC-LSDA, -PBE, and -TPSS results. Furthermore, we propose selective scaling of OSIC (SOSIC) to remove its major shortcoming that destroys the -1/r asymptotic behavior of the potentials. The SOSIC method gives the highest occupied orbital eigenvalues practically identical to those in PZSIC and unlike OSIC provides bound atomic anions even with larger powers of scaling factors. Furthermore, SOSIC compared to PZSIC or OSIC provides more balanced description of total energies and barrier heights.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating Subhourly Inverter Clipping Loss From Satellite-Derived Irradiance Data

Photovoltaic system production simulations are conventionally run using hourly weather datasets. Hourly simulations are sufficiently accurate to predict the majority of long-term system behavior but cannot resolve high-frequency effects like inverter clipping caused by short-duration irradiance variability. Direct modeling of this subhourly clipping error is only possible for the few locations with high-resolution irradiance datasets. This paper describes a method of predicting the magnitude of this error using a machine learning regressor ensemble model, comprised of a random forest and an XGBoost model, and 30-minute satellite irradiance data. The method predicts a correction for each 30-minute interval with the potential to roll up into 60-minute corrections to match an hourly energy model. The model is trained and validated at locations where the error can be directly simulated from 1-minute ground data. The validation shows low bias at most ground station locations. The model is also applied to gridded satellite irradiance to produce a heatmap of the estimated clipping error across the United States. Finally, the relative importance of each predictor satellite variable is retrieved from the model and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Explicitly correlated ring-coupled-cluster-doubles theory

The connection between the random-phase approximation and the ring-coupled-cluster-doubles method bridges the gap between density-functional and wave-function theories and the importance of the random-phase approximation lies in both its broad applicability and this linking role in electronic-structure theory. In this contribution, we present an explicitly correlated approach to the random-phase approximation, based on the direct ring-coupled-cluster-doubles ansatz, which overcomes the problem of slow basis-set convergence, inherent to the random-phase approximation. Benchmark results for a test set of 106 molecules and a selection of 10 organic complexes from the S22 test set demonstrate that convergence to within 99% of the basis-set limit is reached for triple-zeta basis sets for atomisation energies, while quadruple-zeta basis sets are required for interaction energies. Corrections due to single excitations into the complementary auxiliary space reduce the basis-set incompleteness error by one order of magnitude, while contributions due to the coupling of conventional and geminal amplitudes are in general negligible. We find that a non-iterative explicitly correlated correction to first order in perturbation theory exhibits the best ratio of accuracy to computational cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison Between Electronic Portal Imaging Device and Cone Beam CT in Radiotherapy Verification of Nasopharyngeal Carcinoma

The demand of greater accuracy in intensity-modulated radiotherapy (IMRT) has driven the development of more advanced verification systems. The purpose of this study is to investigate the differences in verification accuracy in terms of the position error detected between cone-beam computed tomography (CBCT) and electronic portal imaging device (EPID) in the IMRT of nasopharyngeal carcinoma (NPC). Two groups of NPC patients (n = 22 and n = 28) verified by CBCT (G1-CB), EPID (G1-EP), and EPID (G2-EP) only, respectively, were recruited. The positional errors between the G1-CB group and the G2-EP group were compared. In addition, the magnitudes of the position errors of EPID taken in the same session of the CBCT, but after necessary corrections (G1-EP), were analyzed. In the CBCT group, 455 CBCT images (G1-CB) and 206 EPID images (G1-EP) were collected, whereas 319 EPID images (G2-EP) for the EPID group, were recorded. The median position errors detected in CBCT were between 0.80 and 0.90 mm in the antero-posterior (A-P), left-right (L-R), and supero-inferior (S-I) directions, whereas those of the EPID were all 0.50 mm. The magnitude of position deviation detected by the CBCT was higher than that of the EPID and their differences were extremely significant (p < 0.001). The frequencies in the G2-EP group with position errors greater than the tolerance (2 mm) were 32, 42, and 27 in the A-P, L-R, and S-I directions, respectively, which accounted for 16.5%, 21.6%, and 13.9% of the total number of EPID. There was difference in verification capability between the CBCT and EPID when applied to IMRT of NPC patients. Because an average of 1 of 6 verifications in EPID was inferior to that of the CBCT, verification by CBCT is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modernizing the active neutron collar poison rod correction using simulations to enhance PWR fresh fuel verification

The declared inventory of 235 U in fresh, low enriched uranium, nuclear fuel assemblies is routinely verified by nuclear safeguards inspectorates using the UNCL (Uranium Neutron Collar – Light Water Reactor Fuel) nondestructive assay instrument. The trend in modern fuels is towards higher initial enrichment, which in turn requires a larger number of burnable poison pins with higher Gadolinia concentration to hold down the initial reactivity. UNCL assay error for modern fuel assemblies typically exceeds 10%. The traditional algorithm used to correct the response for burnable poison content needs revision to achieve accuracy comparable to the $\sigma_\text{R}$ of 4.5% expected for poison-free assemblies. Here we review the problem and use a large set of 287 Monte Carlo simulations based on an experimentally benchmarked model corresponding to the 16×16 PWR array used in Brazilian Angra type II and III fuel. Simulated relative responses are used to evaluate the functional form of the poison correction and determine parameters optimal for 16×16 PWR assemblies. This update is conducted using between 4–24 Gadolinia pins ranging 2–11 wt% Gd 2 O 3 with assemblies having mean enrichments ranging 2.5%–5%. Experimental validation of the updated coefficients using seven measurements shows bias is reduced by an order of magnitude and $\sigma_\text{R}$R reduced from 10% to less than 2%. Two updated sets of coefficients are provided, the most accurate of which is directly useable in the existing analysis code (INCC) in use by inspectorate at fuel fabrication facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEMPERATURE STRUCTURE AND METALLICITY IN H II REGIONS

The metallicities implied by collisionally excited lines (CELs) of heavy elements in H II regions are systematically lower than those implied by recombination lines (RLs) by factors of approx2, introducing uncertainties of the same order in the metallicities inferred for the interstellar medium of any star-forming galaxy. Most explanations of this discrepancy are based on the different sensitivities of CELs and RLs to electron temperature, and invoke either some extra heating mechanism producing temperature fluctuations in the ionized region or the addition of cold gas in metal-rich inclusions or ionized by cosmic rays or X-rays. These explanations will change the temperature structure of the ionized gas from the one predicted by simple photoionization models, and depending on which one is correct, will imply different metallicities for the emitting gas. We select nine H II regions with observed spectra of high quality and show that simple models with metallicities close to the ones implied by oxygen CELs reproduce easily their temperature structure, measured with T{sub e}([N II])/T{sub e}([O III]), and their oxygen CELs emission. We discuss the strong constraints that this agreement places on the possible explanations of the discrepancy and suggest that the simplest explanation, namely errors in the line recombination coefficients by factors approx2, might be the correct one. In such case, CELs will provide the best estimates of metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-123: Targeting Accuracy of Image-Guided Radiosurgery for Intracranial Lesions

Purpose: To evaluate the setup accuracies of image-guided intracranial radiosurgery across several different linear accelerator platforms. Methods: A CT scan with a slice thickness of 1.0 mm was acquired of a Rando head phantom (The Phantom Laboratory) in a U-frame mask (BrainLAB AG). The phantom had three embedded BBs, simulating a central, left, and anterior lesion. The phantom was setup with each BB placed at the radiation isocenter under image guidance. Four different setup procedures were investigated: (1) NTX-ExacTrac: 6 degree-of-freedom (6D) correction on a Novalis Tx (BrainLAB AG) with ExacTrac localization (BrainLAB AG); (2) NTX-CBCT: 4D correction on the Novalis Tx with cone-beam computed tomography (CBCT); (3) TrueBeam-CBCT: 4D correction on a TrueBeam (Varian) with CBCT; (4) Edge-CBCT: 6D correction on an Edge (Varian) with CBCT. The experiment was repeated 5 times with different initial setup error at each BB location on each platform, and the mean (μ) and one standard deviation (σ) of the residual error was compared.The congruence between radiation and imaging isocenters on each platform was evaluated by acquiring Winston Lutz (WL) images of a WL jig followed by imaging using ExacTrac or CBCT. The difference in coordinates of the jig relative to radiation and imaging isocenters was then recorded. Results: Averaged over all three BB locations, the residual vector setup errors (μ±σ) of the phantom in mm were 0.6±0.2, 1.0±0.5, 0.2±0.1, and 0.3±0.1 on NTX-ExacTrac, NTX-CBCT, TrueBeam-CBCT, and Edge-CBCT, with their ranges in mm being 0.4∼1.1, 0.4∼1.9, 0.1∼0.5, and 0.2∼0.6, respectively. And imaging isocenter was found stable relative to radiation isocenter, with the congruence to radiation isocenter in mm being 0.6±0.1, 0.7±0.1, 0.3±0.1, 0.2±0.1, respectively, on the four systems in the same order. Conclusion: Millimeter accuracy can be achieved with image-guided radiosurgery for intracranial lesions based on this set of experiments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refined Telluric Absorption Correction for Low-resolution Ground-based Spectroscopy: Resolution and Radial Velocity Effects in the O{sub 2}A-band for Exoplanets and K i Emission Lines

Telluric correction of spectroscopic observations is either performed via standard stars that are observed close in time and airmass along with the science target, or recently growing in importance, by theoretical telluric absorption modeling. Both approaches work fine when the telluric lines are resolved, i.e., at a spectral resolving power larger than about 10,000, and it is sufficient to facilitate the detection of spectral features at lower resolution. However, a meaningful quantitative analysis also requires the reliable recovery of line strengths. Here, we show for the Fraunhofer A-band of molecular O{sub 2} that the standard telluric correction approach fails in this at lower spectral resolutions, as an example for the general problem. Doppler-shift-dependent errors of the restored flux may arise, which can amount to more than 50% in extreme cases, depending on the line shapes of the target spectral features. Two applications are discussed: the recovery of the O{sub 2} band in the reflected light of an Earth analog atmosphere, as facilitated potentially in the future using an orbiting starshade and a ground-based extremely large telescope; and the recovery of the intrinsic ratio of the K i lines in the post-nova V4332 Sgr tracing the optical depth of the emitting region, to exemplify the relevance using present-day instrumentation. We show how one should derive correction functions for the compensation of the error in dependence of radial velocity shift, spectral resolution, and target line-profile function by use of high-resolution atmospheric transmission modeling, which has to be solved for the individual case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: An improved calibration system with phase correction for electronic transformers with digital output

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ensuring Σ s Y s = 1 in transport of species mass fractions

When transporting species mass fractions in reacting flow simulations, there are physical constraints that must be met. Unfortunately, nonlinear transport schemes such as weighted essentially non-oscillatory (WENO) schemes do not ensure that the sum of mass fractions equals 1. In detonation simulations, errors in the sum of mass fractions are observed to worsen over time when the standard WENO scheme is used. To prevent this, typically one species is forced to absorb all or most of the error in the sum of mass fractions. Here, this work presents an alternative method for correcting the WENO-interpolated mass fractions such that inert species do not change. The method is demonstrated for both argon and nitrogen-diluted hydrogen detonations in one dimension. Using the modified WENO interpolations, the error in the sum is reduced significantly. In addition, the new approach is better able to capture the physical instability expected for nitrogen-diluted detonations.

74 ATOMIC AND MOLECULAR PHYSICS↗