Dynamics and Control of Microgrids as a Resiliency Source

Microgrids can be operated in a utility-connected mode with the neighboring distribution system or in an islanded mode in separation with the distribution system. As the major disasters occur more and more often, islanded microgrid is proposed as a possible solution to serve essential loads until the utility service is restored. This paper evaluates the feasibility of using microgrids as a resiliency resource by a field test. A control scheme, integrating droop control and feedback control, is applied on a modified IEEE 13-node test feeders. The simulation results validate the proposed control scheme and the transient stability

Lee, Lung-An↗

Identification of Critical Switches for Integrating Renewable Distributed Generation by Dynamic Network Reconfiguration

With growing penetration of renewable distributed generations (DGs) in distribution systems, effective integration of DGs has become a major concern. Distribution system dynamic reconfiguration (DSDR), which relies on real-time operations of remote-controlled switches, is potentially an efficient strategy receiving inadequate attention. Moreover, in most DSDR-related publications, normally all switches are assumed remotely controllable, which is not practical. Here we borrow the concept of critical switches to denote the switches that are most effective in accommodating DGs by DSDR. In this regard, the problem of identifying critical switches is not well investigated, although in several related publications, selected switches are assumed remote-controlled based on experience. In this work, we study the application of DSDR for DG integration. Critical switches, which optimally enable intra-day DSDR to minimize DG curtailments, are identified by limiting the number of switches to be operated and the switch-type-dependent operation constraints. Considering uncertainties of loads and DGs, the problem is formulated as a two-stage robust optimization model solved by a nested column-and-constraint generation algorithm. Illustrative cases show that DG curtailments can be significantly reduced by a small number of critical switches that operate only several times in intra-day DSDR. The proposed method can be used to provide insights for switch allocation, maintenance, and operation

Lei, Shunbo (ORCID:0000000181690821)↗

A controlled experiment on the impact of software structure on maintainability

The impact of software structure on maintainability aspects including comprehensibility, locality, modifiability, and reusability in a distributed system environment is studied in a controlled maintenance experiment involving six medium-size distributed software systems implemented in LADY (language for distributed systems) and six in an extended version of sequential PASCAL. For all maintenance aspects except reusability, the results were quantitatively given in terms of complexity metrics which could be automated. The results showed LADY to be better suited to the development of maintainable software than the extension of sequential PASCAL. The strong typing combined with high parametrization of units is suggested to improve the reusability of units in LADY.

Rombach, Dieter H.↗

Realistic Synthetic Distribution Grids: Summary of Validation Results

The presentation slides will walk us through the validation process and results of the synthetic distribution grid data. The synthetic grids for the distribution systems were developed as part of the ARPA-E funded GRIDDATA program project, SMART-DS. Three large scale datasets for US style distribution system were developed: 1) SAF: Santa Fe urban region, 2) GSO: Greensboro urban, semi-urban and industrial region, and 3) SFO: San Francisco Bay Area urban, semi-urban, industrial and rural areas. These datasets were validated using a three-pronged validation process, including statistical, operational and expert validation phases; the results of which have been summarized in this deck.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

A distributed microprocessor system for spacecraft control and data handling

The specific requirements for spacecraft computing systems are considered. These requirements are partly related to the constraints of limited resources of power, weight, and volume. Another important factor is the requirement of extremely high reliability. These reliability requirements have led to introduction of automated redundancy techniques on board the spacecraft. The various redundant computers check each other and provide recovery procedures when a computer is found to have failed. Past and future capabilities are considered along with distributed processing requirements. System considerations are discussed, taking into account suboptimum computer throughput, sensitivity to software modifications, hierarchic timing, I/O granularity, restricted communications, synchronous functions, hierarchic control, and concurrent error detection. A description is presented of the Unified Data System (UDS), which consists of a set of standard microcomputers connected by several buses. Attention is also given to synchronization and timing, the executive control structure, the programming language, and the executive program.

Rennels, D. A.↗

Conceptual design of the FRIB cryogenic system

The Facility for Rare Isotope Beams (FRIB) is a new nuclear science facility funded by the DOE Office of Science and Michigan State University (MSU). FRIB is currently under design and will be located on the MSU campus. The centerpiece of FRIB is a heavy ion linac utilizing superconducting RF cavities and magnets which in turn requires a large cryogenic system. The cryogenic system consists of a commercially produced helium refrigeration plant and an extensive distribution system. Superconducting components will operate at both 4.5 K and 2 K. This paper describes the conceptual design of the system including the expected heat loads and operating modes. The strategy for procuring a custom turnkey helium refrigeration plant from industry, an overview of the distribution system, the interface of the cryogenic system to the conventional facilities and the project schedule are also described.

43 PARTICLE ACCELERATORS↗

DSO+T: Integrated System Simulation (DSO+T Study: Volume 2)

This report summarizes an integrated co-simulation model used by the Distribution System Operator with Transactive (DSO+T) study to represent an electrical generation, delivery, and end-load systems for the purposes of assessing the viability and value proposition of transactive energy coordination of flexible assets versus a business-as-usual case. The integrated co-simulation model includes the bulk generation and transmission system, including the day-ahead and real-time scheduling and dispatch of thermal generators. Forty distribution system operators were modelled in detail, including tens of thousands of residential and commercial buildings and their flexible end-loads. These included HVAC systems, residential water heaters, electric vehicles, and stationary, behind-the-meter, batteries. Both wholesale market and end-load results for the business-as-usual case are presented and compared to actual ERCOT system data to assess the accuracy and representativeness of the resulting model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enriching Load Data Using Micro-PMUs and Smart Meters

In modern distribution systems, load uncertainty can be fully captured by micro-PMUs, which can record high-resolution data; however, in practice, micro-PMUs are installed at limited locations in distribution networks due to budgetary constraints. In contrast, smart meters are widely deployed but can only measure relatively low-resolution energy consumption, which cannot sufficiently reflect the actual instantaneous load volatility within each sampling interval. In this paper, we have proposed a novel approach for enriching load data for service transformers that only have low-resolution smart meters. The key to our approach is to statistically recover the high-resolution load data, which is masked by the low-resolution data, using trained probabilistic models of service transformers that have both high- and low-resolution data sources, i.e., micro-PMUs and smart meters. The overall framework consists of two steps: first, for the transformers with micro-PMUs, a Gaussian Process is leveraged to capture the relationship between the maximum/minimum load and average load within each low-resolution sampling interval of smart meters; a Markov chain model is employed to characterize the transition probability of known high-resolution load. Next, the trained models are used as teachers for the transformers with only smart meters to decompose known low-resolution load data into targeted high-resolution load data. The enriched data can recover instantaneous load uncertainty and significantly enhance distribution system observability and situational awareness. Here, we have verified the proposed approach using real high- and low-resolution load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

R-SEEDS Final Report

DER aggregation and grid digitalization imply a future grid that would benefit from more fluid interaction between the bulk power system and the distribution system. This scenario presents a challenge for grid modeling, which treats the two systems separately. Grid modeling also focuses on the engineering aspects of grids without incorporating modeling of the human and social dimensions of the grid as a cyber-physical-social system. The R-SEEDS project examines the integration of human and social models into grid modeling and its implications on decarbonization, energy justice, and distributional impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The effect of concentrator field layout on the performance of point-focus distributed receiver systems

The effect of concentrator field layout on the technical-economic performance of a point-focusing distributed receiver (PFDR) solar thermal power plant is presented. The plant design is based on the small community prototype system currently under development for JPL/DOE; parabolic dish concentrators are employed, and small heat engines are used to generate electricity at each dish. The effect of field size, array proportions, dish-to-dish spacing and packing fraction (concentrator-land area ratio) are presented for typical PFDR layouts. Economic analyses are carried out to determine optimum packing fraction as a function of site cost.

Pons, R. L.↗

The WorkPlace distributed processing environment

Real time control problems require robust, high performance solutions. Distributed computing can offer high performance through parallelism and robustness through redundancy. Unfortunately, implementing distributed systems with these characteristics places a significant burden on the applications programmers. Goddard Code 522 has developed WorkPlace to alleviate this burden. WorkPlace is a small, portable, embeddable network interface which automates message routing, failure detection, and re-configuration in response to failures in distributed systems. This paper describes the design and use of WorkPlace, and its application in the construction of a distributed blackboard system.

Ames, Troy↗

Flexible Operation of Microgrids Through Operator-Configurable Microgrid Controllers

Microgrids are becoming critical assets in power distribution systems. This is partly due to the resiliency and reliability challenges faced by power distribution systems in the last decade and partly due to the increased integration of distributed energy resource assets, such as solar photovoltaic. This increased need for microgrids has created a multitude of needs for microgrid controllers. Most microgrid controllers in the past decade have been uniquely programmed or custom programmed to meet the needs of a specific microgrid. Currently, IEEE standards aim to integrate the needs and capabilities of microgrid controllers under a unified umbrella. But the standards do not recommend necessary or appropriate software development practices for microgrid controllers. In addition, the programmable nature and maintenance of controllers are also key characteristics that fall outside the coverage of the standards. In this paper, we present the best software practices that utility engineers and microgrid operators should consider in the microgrid software platform. This paper can be used as an information document for developing documentation of controller requirements and assessing microgrid controller requirements.

Banshee microgrid↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of Network Model Detail on Estimated Health Effects of Drinking Water Contamination Events

Network model detail can influence the accuracy of results from analyses of water distribution systems. Previous work has shown the limitations of skeletonized network models when considering water quality and hydraulic effects. Loss of model detail is potentially less important for aggregated effects such as the systemwide health effects associated with a contamination event, but has received limited attention. The influence of model detail on such effects is examined here by comparing results obtained for contamination events using three large network models and several skeletonized versions of the models. Loss of model detail decreases the accuracy of estimated aggregated adverse effects related to contamination events. It has the potential to have a large negative influence on the results of consequence assessments and the design of contamination warning systems. However, the adverse influence on analysis results can be minimized by restricting attention to high percentile effects (i.e., 95th percentile or higher).

Davis, Michael J.↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-mode fiber systems for deep space communication network

The present investigation is concerned with the development of single-mode optical fiber distribution systems. It is pointed out that single-mode fibers represent potentially a superior medium for the distribution of frequency and timing reference signals and wideband (400 MHz) IF signals. In this connection, single-mode fibers have the potential to improve the capability and precision of NASA's Deep Space Network (DSN). Attention is given to problems related to precise time synchronization throughout the DSN, questions regarding the selection of a transmission medium, and the function of the distribution systems, taking into account specific improvements possible by an employment of single-mode fibers.

Lutes, G.↗