At least 1,747 records · Page 97

Quantifying electron temperature distributions from time-integrated x-ray emission spectra

K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. Here we present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of $1310^{+90}_{-70}$ eV with significant contributions from temperatures down to 200 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applications of machine learning to a compact magnetic spectrometer for high repetition rate, laser-driven particle acceleration

Accurately and rapidly diagnosing laser–plasma interactions is often difficult due to the time-intensive nature of the analysis and will only become more so with the rise of high repetition rate lasers and the desire to implement feedback on a commensurate timescale. Diagnostic analysis employing machine learning techniques can help address this problem while maintaining a high degree of accuracy. We report on the application of machine learning to the analysis of a scintillator-based electron spectrometer for experiments on high intensity, laser–plasma interactions at the Colorado State University Advanced Lasers and Extreme Photonics facility. Our approach utilizes a neural network trained on synthetic data and tested on experiments to extract the accelerated electron temperature. By leveraging transfer learning, we demonstrate an improvement in the neural network accuracy, decreasing the network error by 50%.

Swanson, K. K. (ORCID:0000000286880568)↗

Observation and diagnostic application of Kr K-shell emission in magnetized liner inertial fusion experiments at Z

In a series of Magnetized Liner Inertial Fusion (MagLIF) experiments performed at the Z pulsed power accelerator of Sandia National Laboratories, beryllium liners filled with deuterium gas pressures in the 4–8 atm range and a tracer amount of krypton were imploded. At the collapse of the cylindrical implosion, temperatures in the 1–3 keV range and atom number densities of ∼1023 cm−3 were expected. The plasma was magnetized with a 10 T axial magnetic field. Krypton was added to the fuel for diagnosing implosion plasma conditions. Krypton K-shell line emission was recorded with the CRITR time-integrated transmission crystal x-ray spectrometer. The observation shows n = 2 to n = 1 line emissions in B-, Be-, Li-, and He-like Kr ions and is characteristic of the highest electron temperatures achieved in the thermonuclear plasma. Detailed modeling of the krypton atomic kinetics and radiation physics permits us to interpret the composite spectral feature, and it demonstrates that the spectrum is temperature sensitive. We discuss temperatures extracted from the krypton data analysis for experiments performed with several filling pressures.

Clapp, J. T. (ORCID:0000000219928146)↗

Design of a Multi-Monochromatic X-ray Imager (MMI) for Kr K-shell line emission

We report the Multi-Monochromatic X-ray Imager (MMI) is a time-gated spectrometer used in implosion experiments at the OMEGA laser facility. From the data, electron temperature and density spatial distributions can be obtained at different implosion times. Previous MMI designs used Ar K-shell emission (3–6 keV) as a spectroscopic tracer and provided a spectral resolution of around 20 eV. However, Ar K-shell line emission becomes less useful at electron temperatures above 2 keV due to over-ionization. Kr K-shell (12–16 keV) has been shown to be an attractive alternative to diagnose hot implosion cores in recent publications. The purpose of this paper is to show a new point design that allows the MMI to detect this higher photon energy range with suitable spectral resolution. The algorithm used to find the optimal design couples a ray-tracing code and an exhaustive parameter space search. This algorithm may be useful as a tool to find optimal MMI designs for other purposes, i.e., other spectral regions for other spectroscopic tracers. So, the main change between the two designs is the replacement of the multi-layer mirror with a flat Bragg Ge (220) crystal. The final Kr K-shell MMI design has a photon energy range from 12 to 16.1 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a multi-detector, single line-of-sight, time-of-flight system to measure time-resolved neutron energy spectra

In the dynamic environment of burning, thermonuclear deuterium–tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ~10 12 longer than inertial confinement fusion (ICF) plasmas. In this work, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV n DT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Installation of a solid state neutral particle analyzer array on mega ampere spherical tokamak upgrade

A compact solid state neutral particle analyzer (SSNPA) diagnostic, previously installed at NSTX-U, has been moved to MAST-U and successfully operated in the first physics campaign (MU01). The SSNPA operates by detecting the flux of fast neutral particles produced by charge exchange (CX) reactions to diagnose the fast ion distribution. The diagnostic consists of three 16-channel sensors, which provide a radial view of the plasma and have a sightline intersection with the South–South neutral beam line. From this radial geometry, active CX signals from mostly trapped particles are observed. Each channel has a spatial resolution of 3–4 cm, a temporal resolution of 200 kHz, and an average pitch angle resolution of a few degrees. The three-sensor configuration allows for coarse energy resolution of the CX signals; each sensor sees similar sightlines but different filter thicknesses alter the energy cutoffs by known amounts. Experimental data show that all channels are collecting data as intended. The signal to noise ratio is typically around 15. Preliminary data analysis shows a correlation between the SSNPA signal and magnetohydrodynamic activity in the plasma as expected.

Instruments & Instrumentation↗

A reduced-model (nSOLT) simulation of neutral recycling effects on plasma turbulence in the divertor region of MAST-U

The 2D scrape-off-layer turbulence code (nSOLT), which includes 1D kinetic neutral–plasma interactions, is applied to study effects of neutral recycling on plasma turbulence for parameters illustrative of the MAST-U divertor region. Neutral recycling is modeled by injecting a fraction of the parallel plasma flux to the divertor back into the simulation domain as a source of Franck–Condon-distributed neutrals. Stationary sources, concentrated at the magnetic separatrix, model plasma streaming into the divertor region from the upstream scrape-off-layer and sustain plasma turbulence absent neutral recycling. Starting from one such no-neutrals equilibrium, we initiate recycling in a numerical experiment designed to diagnose and identify the effects of various neutral–plasma interactions on the divertor plasma, divertor turbulence, and plasma exhaust. The onset of recycling triggers an initial burst of enhanced cross field plasma transport that is quelled by ionization cooling and charge–exchange (CX) friction, with growing neutral pressure, leading to a quiescent, turbulence-free state. Diagnosis of this transient burst reveals that (1) the sudden increase in plasma density due to ionization dominates the onset of the burst, (2) electron cooling due to ionization increases collisionality and disconnects blob filaments from the sheath, and (3) CX friction drives tripole polarization of a blob that can dominate the curvature-driven dipole polarization, leading to the stagnation of blob propagation and reduced radial turbulent transport. It is shown that CX friction is negligible compared to sheath physics in determining equilibrium mean flow shearing rates, for parameters considered herein (specifically a short connection length to the divertor target), while it can significantly reduce interchange-instability growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strong collisionless coupling between an unmagnetized driver plasma and a magnetized background plasma

Fast-exploding plasmas traveling though magnetized, collisionless plasmas can occur in a variety of physical systems, such as supernova remnants, coronal mass ejections, and laser-driven laboratory experiments. To study these systems, it is important to understand the coupling process between the plasmas. Here, in this work, we develop a semi-analytical model of the parameters that characterize the strong collisionless coupling between an unmagnetized driver plasma and a uniformly and perpendicularly magnetized background plasma. In particular, we derive analytical expressions that describe the characteristic diamagnetic cavity and magnetic compression of these systems, such as their corresponding velocities, the compression ratio, and the maximum size of the cavity. The semi-analytical model is compared with collisionless 1D particle-in-cell simulations and experimental results with laser-driven plasmas. The model allows us to provide bounds for parameters that are otherwise difficult to diagnose in experiments with similar setups.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiative cooling effects on reverse shocks formed by magnetized supersonic plasma flows

We study the structure of reverse shocks formed by the collision of supersonic, magnetized plasma flows driven by an inverse (or exploding) wire array with a planar conducting obstacle. We observe that the structure of these reverse shocks varies dramatically with wire material, despite the similar upstream flow velocities and mass densities. For aluminum wire arrays, the shock is sharp and well-defined, consistent with magneto-hydrodynamic theory. In contrast, we do not observe a well-defined shock using tungsten wires, and instead we see a broad region dominated by density fluctuations on a wide range of spatial scales. We diagnose these two very different interactions using interferometry, Thomson scattering, shadowgraphy, and a newly developed imaging refractometer that is sensitive to small deflections of the probing laser corresponding to small-scale density perturbations. We conclude that the differences in shock structure are most likely due to radiative cooling instabilities, which create small-scale density perturbations elongated along magnetic field lines in the tungsten plasma. These instabilities grow more slowly and are smoothed by thermal conduction in the aluminum plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy transfer and scale dynamics in 2D and 3D laser-driven jets

We demonstrate a methodology for diagnosing the multiscale dynamics and energy transfer in complex HED flows with realistic driving and boundary conditions. The approach separates incompressible, compressible, and baropycnal contributions to energy scale-transfer and quantifies the direction of these transfers in (generalized) wavenumber space. We use this to compare the kinetic energy (KE) transfer across scales in simulations of 2D axisymmetric vs fully 3D laser-driven plasma jets. Using the FLASH code, we model a turbulent jet ablated from an aluminum cone target in the configuration outlined. We show that, in addition to its well known bias for underestimating hydrodynamic instability growth, 2D modeling suffers from significant spurious energization of the bulk flow by a turbulent upscale cascade. In 2D, this arises as vorticity and strain from instabilities near the jet's leading edge transfer KE upscale, sustaining a coherent circulation that helps propel the axisymmetric jet farther (⁠ ≈25% by 3.5 ns) and helps keep it collimated. In 3D, the coherent circulation and upscale KE transfer are absent. Here, the methodology presented here may also help with inter-model comparison and validation, including future modeling efforts to alleviate some of the 2D hydrodynamic artifacts highlighted in this study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A coded aperture with sub-mean-free-path thickness for implosion geometry imaging on ICF and IFE experiments

Inertial confinement fusion and inertial fusion energy experiments diagnose the geometry of the fusion region through imaging of the neutrons released through fusion reactions. Pinhole arrays typically used for such imaging require thick substrates to obtain high contrast along with a small pinhole diameter to obtain high resolution capability, resulting in pinholes that have large aspect ratios. This leads to expensive pinhole arrays that have small solid angles and are difficult to align. Here, we propose a coded aperture with scatter and partial attenuation (CASPA) for fusion neutron imaging that relaxes the thick substrate requirement for good image contrast. These coded apertures are expected to scale to larger solid angles and are easier to align without sacrificing imaging resolution or throughput. We use Monte Carlo simulations (Geant4) to explore a coded aperture design to measure neutron implosion asymmetries on fusion experiments at the National Ignition Facility (NIF) and discuss the viability of this technique, matching the current nominal resolution of 10 µm. The results show that a 10 mm thick tungsten CASPA can image NIF implosions with neutron yields above 10 14 with quality comparable to unprocessed data from a current NIF neutron imaging aperture. Furthermore, this CASPA substrate is 20 times thinner than the current aperture arrays for fusion neutron imaging and less than one mean free-path of 14.1 MeV neutrons through the substrate. Since the resolution, solid angle, and throughput are decoupled in coded aperture imaging, the resolution and solid angle achievable with future designs will be limited primarily by manufacturing capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiochemical diagnostics at the National Ignition Facility

Since the National Ignition Facility (NIF) was commissioned in 2009, radiochemical techniques have been viewed as a potential method for diagnosing the performance of an NIF fusion shot. Radiochemical methods can also be used in conjunction with NIF shots to measure nuclear reaction cross sections in regimes that are inaccessible at accelerator facilities and can provide a route to produce radioactive tracer materials that can be used for other applications. Here, this review presents the current status of radiochemical diagnostics at the NIF. Experimental results and the status of both solid and gaseous debris collection radiochemistry are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of mix at the fuel–ablator interface in indirectly driven capsule implosions on the National Ignition Facility

The interface between the capsule ablator and fuel ice layer is susceptible to hydrodynamic instabilities. The subsequent mixing of hot ablator material into the ice reduces fuel compression at stagnation and is a candidate for reduced capsule performance. The ability to diagnose ice–ablator mix is critical to understanding and improving stability at this interface. Combining the crystal backlighter imager with the single line of sight camera on the National Ignition Facility (NIF) allows direct measurement of ice–ablator mix by providing multiple quasi-monochromatic radiographs of layered capsule implosions per experiment with high spatial (∼12 μm) and temporal (∼35 ps) resolution. The narrow bandwidth of this diagnostic platform allows radiography of the inner edge of the capsule limb close to stagnation without capsule self-emission contaminating the data and removes opacity uncertainties typically associated with the spectral content of the radiograph. Analysis of radiographic data via a parameterized forward-fitting Abel inversion technique provides measurements of the distribution of mix mass inwards from the ice–ablator interface. The sensitivity of this mix measurement technique was demonstrated by applying it to layered experiments in which the stability of the ice–ablator interface was expected to vary significantly. Additional experiments suggest that high-density carbon capsules that employ a buried-layer dopant profile suffer from mixing at the innermost doped–undoped interface. Data from these experiments suggest that opacity models used in hydrodynamic simulations of NIF experiments can potentially over-predict the opacity of doped capsules. LLNL-JRNL-850535-DRAFT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature and density dependence of Kr L-shell spectrum in hot dense plasmas

Kr L-shell spectroscopy modeling results are discussed in this paper, focusing on the n = 4 to n = 2 line transitions of Be- and Li-like Kr ions. Collisional radiative atomic kinetic and Stark-broadened spectral line shape calculations show electron temperature Te and density ne sensitivity in the spectrum. The combination of the Te dependence due to the relative intensity of Be-like to Li-like line emissions in the range from 1.5 to 3 keV and the ne sensitivity from the Stark broadening effect on the line shapes in the range from 5×1023 to 2×1024/ cc results in a spectrum that can be employed to diagnose Te and ne. Two different collisional radiative atomic kinetic models i.e., Prismspect [J. J. MacFarlane, et al., Int. Fusion Sci. Appl. Conf. Proc. 457 (2003)] and ABAKO [Florido, et al., PRE, 80, 056402 (2009)] produce similar results in level populations and spectra. In x-ray spectroscopy of implosion cores, this Kr L-shell spectrum may prove useful in an intermediate Te range in which Ar is too ionized for its K-shell to be of diagnostic value and Kr is not ionized enough for its K-shell emission to be useful.

Physics↗

Generation of strong fields with subcritical density plasmas to study the phase transitions of magnetized warm dense matter

Warm dense matter (WDM) is a regime where Fermi degenerate electrons play an important role in the macroscopic properties of a material. Recent experiments have brought us closer to understanding unmagnetized processes in WDM, but magnetized WDM remains unexplored because kilotesla magnetic fields are required. Although there are examples of field compression generating such fields by imploding pre-magnetized targets, these existing methods give no independent control over the parameters of the magnetized plasma and result in limited laser access for sample creation and diagnosis. In this paper, numerical simulations show that kilotesla magnetic fields can be obtained by shining laser beams onto the inner surface of a cylindrical target, rather than on the outer surface. This approach relies on field compression by a low-density, high-temperature plasma, rather than a high-density, low-temperature plasma, used in the more conventional approach. With this novel configuration, the region of peak magnetic field is mostly free of plasma, hence, other beams can reach a sample placed in the region of the peak field to form WDM and diagnose it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward electron temperature profiles in hot-dense plasmas from x-ray spectral ensembles

High repetition rate laser systems enable new strategies for diagnosing plasma behavior with large datasets. Here, we define an ensemble technique that relies on randomized targeting of x-ray tracer micro-stripes. On each shot, a high-intensity laser pulse is focused on a solid target with Ti tracer stripes embedded in an Al foil, randomly targeting a micro-stripe, a portion of a stripe, or a gap between stripes. High-resolution, time-integrated x-ray spectrometers capture line emission from the portion of the micro-stripe that is heated to sufficiently high electron temperatures. Accumulation of many such cases is used to construct ensemble distributions of x-ray line intensities that encompass all relative offsets of the laser focus to the micro-stripe centers. Synthetic intensity distributions are likewise generated using collisional-radiative modeling. Bayesian fitting of modeled to measured intensity distributions establishes the most likely radial temperature profiles, enabling comparison to hydrodynamic models and calling into question the cylindrical symmetry of these micro-stripe-embedded systems. Ensemble techniques have significant potential for high-energy-density plasma diagnostics, especially with the advent of high repetition rate experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the electron cyclotron emission radiation signature from suprathermal electrons in a tokamak

An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron–microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v ⊥ and v || , while the X2 mode is dominantly sensitive to suprathermal electrons of a high v ⊥ . Finally, the modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.