Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Radon Dose Determination for Cave Guides in Czech Republic

According to recommended approach there are six (from total of twelve) open-to-public caves in Czech Republic, reaching near to an effective lung-dose of 6mSv/year. A conservative approach for estimating the potential effective lung-dose in caves (or underground) is based on two season's measurements, using solid state alpha track detector (Kodak in plastic diffusion chamber). The obtained dataset is converted into an annual effective dose, in agreement with the ICRP65 recommendation, using the 'cave factor' 1.5. The value of 'cave factor' which depends on the spectrum of aerosol particles, or on the proportional representation of the unattached/attached ratio (6.5 : 93.5 for residential places, 13.6 : 86.4 for caves due to lower concentration of free aerosols) and on the equilibrium factor. Thus conversion factor is 1.5 times higher in comparison with ICRP 65. Is this correct? Because a more precisely determined dose value would have a significant impact on radon remedies, or on restricting the time workers stay underground, a series of measurement was initiated in 2003 with the aim to specify input data, computation and errors in effective dose assessment in each one of the evaluated caves separately. The enhancement of personal dosimetry for underground work places includes a study of the given questions, from the following points of view in each cave: continual radon measurement; regular measurements of radon and its daughters to estimate the equilibrium factor and the presence of free {sup 218}Po; regular indoor air flow measurements to study the location of the radon supply and its transfer among individual areas of the cave; natural radioactive element content evaluation in subsoil and in water inside/outside, a study of the radon sources in the cave; determination of the free fraction from continual unattached and attached fraction measurement (grid and filter); thoron measurement. Air flow measurements provide very interesting information about the origin of 'radon pockets' with very high radon concentration, and enable study of the location of the radon supply and its transfer among individual areas of the cave. Most of the results show the equilibrium factor around F = 0.2-0.7 and the unattached fraction around 2%-30%. One of the most important question remains: how accurately was the unattached fraction measured? Part of this project was to verify the influence of etched track detector position in the cave.

54 ENVIRONMENTAL SCIENCES↗

Determination of helicities in unidirectional assemblies of graphitic or graphiticlike tubular structures

Here we propose a universal method for the determination of all helicities present in unidirectional assemblies of hexagon-based graphitic or graphiticlike tubular structures, e.g., multiwalled or bundled carbon nanotubes (CNTs) or boron-nitride nanotubes and their structural analogs. A critical dimension characteristic of a fundamental structural property, i.e., the atomic bond length, is discerned from electron diffraction patterns by which all helicities present in the assemblies are identified. Using this method, we determine the helicity population in a single-walled CNT sample produced by laser ablation technique.

36 MATERIALS SCIENCE↗

Improvement of the Determination of the WIMP Mass from Direct Dark Matter Detection Data

Weakly Interacting Massive Particles (WIMPs) are one of the leading candidates for Dark Matter. We developed a model--independent method for determining the WIMP mass by using data (i.e., measured recoil energies) of direct detection experiments. Our method is independent of the as yet unknown WIMP density near the Earth, of the form of the WIMP velocity distribution, as well as of the WIMP-nucleus cross section. It requires however positive signals from at least two detectors with different target nuclei. At the first phase of this work we found a systematic deviation of the reconstructed WIMP mass from the real one for heavy WIMPs. Now we improved this method so that this deviation can be strongly reduced for even very high WIMP mass. The statistical error of the reconstructed mass has also been reduced. In a background-free environment, a WIMP mass of {approx}50 GeV could in principle be determined with an error of {approx}35% with only 2x50 events.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of Microlensing Selection Criteria for the SuperMACHO Survey

The SuperMACHO project is a 5 year survey to determine the nature of the lens population responsible for the excess microlensing rate toward the Large Magellanic Cloud observed by the MACHO project [1]. The survey probes deeper than earlier surveys unveiling many more extragalactic contaminants, particularly type Ia supernovae and active galactic nuclei. Using {approx}10{sup 7} simulated light curves of both microlensing events and type Ia supernovae we determine selection criteria optimized to maximize the microlensing detection efficiency while minimizing the contamination rate from non-microlensing events. We discuss these simulations and the selection criteria.

99 GENERAL AND MISCELLANEOUS↗

A Novel Method to Determine the Hydrodynamic Coefficients of an Eyeball ROV

A good dynamics model is essential and critical for the successful design of navigation and control system of an underwater vehicle. However, it is difficult to determine from the hydrodynamic forces, the inertial added mass terms and the drag coefficients. In this paper, a new experimental method has been used to find the hydrodynamic forces for the ROV II, a remotely operated underwater vehicle. The proposed method is based on the classical free decay test, but with the spring oscillation replaced by a pendulum motion. The experiment results determined from the free decay test of a scaled model compared well with the simulation results obtained from well‐established computational fluid dynamics (CFD) program. Thus, the proposed approach can be used to find the added mass and drag coefficients for other underwater vehicles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward an Experimentally Determined {sup 26m}Al(p,{gamma}){sup 27}Si Reaction Rate in ONe Novae

Evidence of the ongoing nucleosynthesis of {sup 26}Al in our galaxy has been found in presolar grains and in observations of the 1.809-MeV {gamma} ray, which results from the {beta} decay of the ground state of {sup 26}Al({sup 26g}Al; t{sub 1/2} = 7.2x 10{sup 5} yrs) to an excited state in {sup 26}Mg. The nucleosynthesis of {sup 26}Al is complicated by the existence of the isomeric state, {sup 26m}Al, at 228 keV (t{sub 1/2} = 6.3 s), which must be treated independently from {sup 26g}Al in certain stellar environments, such as ONe novae, where temperatures are below 0.4 GK [1]. {sup 26m}Al{beta} decays directly to {sup 26g}Mg, bypassing the emission of the 1.809-MeV {gamma} ray. The {sup 26g}Al(p,{gamma}){sup 27}Si and {sup 26m}Al(p,{gamma}){sup 27}Si reactions destroy {sup 26}Al in novae and have a direct impact on the net amount of {sup 26}Al produced. While the {sup 26g}Al(p,{gamma}){sup 27}Si reaction rate has been studied extensively, there has been virtually no information published on resonances of the {sup 26m}Al(p,{gamma}){sup 27}Si reaction and previously published reaction rates [2] have been based on {sup 26g}Al+p resonances and Hauser-Feshbach calculations. The {sup 27}Al({sup 3}He,t){sup 27}Si*(p){sup 26}Al and {sup 28}Si({sup 3}He,{alpha}){sup 27}Si*(p){sup 26}Al reactions have been studied at the Wright Nuclear Structure Laboratory at Yale University. Proton decays from the excited states in {sup 27}Si populated via the {sup 27}Al({sup 3}He,t){sup 27}Si and {sup 28}Si({sup 3}He,{alpha}){sup 27}Si transfer reactions were detected in coincidence with the reaction products of interest, which were detected at the focal plane of the Yale Enge spectrograph. Angular correlations were measured to constrain spins and determine proton branching ratios for {sup 26m}Al+p resonances with E{sub cm}>450 keV and excitation energies of {sup 27}Si were measured. Using this information a {sup 26m}Al(p,{gamma}){sup 27}Si reaction rate based on experimental information has been calculated for the first time. The extreme differences in proton decays from excited states in {sup 27}Si to {sup 26g}Al and {sup 26m}Al show that {sup 26m}Al(p,{gamma}){sup 27}Si reaction rates found using experimental data for {sup 26g}Al+p resonances are not valid, and a direct {sup 26m}Al(p,{gamma}){sup 27}Si measurement must be made to reliably determine the strengths of low-energy resonances, which most likely dominate the reaction rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative Determination of Deuterium Atom Concentration in Zinc Oxide Thin Films by Time-of-Flight Secondary Ion Mass Spectrometry

ZnO is a wide-gap semiconductor with very interesting electronic properties.[1,2] Therefore, it has been extensively studied for many years. It has been found that even low centrations of hydrogen in ZnO film can considerably change its electronic behavior.[3-5] Quite a few papers have discussed this issue but it has not been fully understood. Lack of experimental data, especially quantitative data on hydrogen concentration in ZnO samples is an important reason. Dynamic SIMS is the best technique to determine concentration of hydrogen atoms in materials.[6-9] However, it is a very specific technique and the entation is mostly available in semiconductor industry. ToF-SIMS is a more versatile instrument and it is more available in universities and research institutes. Background hydrogen interference has been known to be a serious problem in quantifying hydrogen atoms in solid samples. Although SIMS is an ultra-high vacuum (UHV) technique, there are still some residual gases existing in vacuum chambers during analysis. Most of them are H2, H2O or CH4, which lead to a background that greatly interferes quantitative detection of hydrogen. Therefore, deuterium atoms have been intentionally introduced into the system to avoid this problem. Standard samples are very important for SIMS quantitative analysis. A common method to prepare such kind of standard samples is ion-implanting. Therefore, a set of standard D-ZnO samples were prepared by ion-implanting in our work. In this paper, we report using ToF-SIMS to quantitatively determine the concentration of deuterium atoms in a number of high-quality epitaxial ZnO films, with a set of standard samples as references. We are especially interested in the detection limit of deuterium concentration in ZnO. In addition, hydrogen background interference was also investigated.

08 HYDROGEN↗

Imaging and Radiography with Nuclear Resonance Fluorescence and Effective-Z (EZ-3D) Determination; SNM Detection Using Prompt Neutrons from Photon Induced Fission

Four new technologies have been developed for use in non-intrusive inspection systems to detect nuclear materials, explosives and contraband. Nuclear Resonance Fluorescence (NRF) provides a three dimensional image of the isotopic content of a container. NRF determines the isotopic composition of a region and specifies the isotopic structure of the neighboring regions, thus providing the detailed isotopic composition of any threat. In transmission mode, NRF provides a two dimensional projection of the isotopic content of a container, much as standard X-ray radiography provides for density. The effective-Z method (EZ-3D) uses electromagnetic scattering processes to yield a three-dimensional map of the effective-Z and the density in a container. The EZ-3D method allows for a rapid discrimination based on effective Z and mass of materials such as those with high Z, as well as specifying regions of interest for other contraband. The energy spectrum of prompt neutrons from photon induced fission (PNPF) provides a unique identification of the presence of actinides and SNM. These four new technologies can be used independently or together to automatically determine the presence of hazardous materials or contraband. They can also be combined with other technologies to provide added specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of K-capture Probability in the Decay of {sup 139}Ce

We have been studying the KX and gamma rays spectra in the electron capture decay of {sup 139}Ce{yields}{sup 139}La, which were measured by Ge-spectrometer. The absolute intensity of KX and the 165.8 keV gamma rays has been determined and the known conversion coefficients of the 165.8 keV gamma transition of {sup 139}La were used. The probability P{sub K} was determined as 0.755{+-}0.054. Our results have good agreement with the results of other works.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method for Atomic Level Polarization Time Decay Determination

A general theory of atomic level polarization momenta decay time is developed without preliminary determination of transversal times of relaxation or any limitation on pulse duration. The essence of the method is to measure the time decay of probe signal polarization plane rotation, which is caused by the time-leading intensive polarized pulse. The interaction of intense elliptically polarized light with the resonant medium consisting of identical two-level atoms with arbitrary total angular momenta is considered. The theory is based on irreducible tensorial formalism, which allows diagonalization of relaxation matrix, introduction of effective decay times associated with the population relaxation, as well as coherence relaxation between magnetic sublevels of a resonant system. The tensor of nonlinear susceptibility of the medium with initial nonequilibrium population at the frequency of the probe signal is obtained. From the formulae it is seen that orientation vector determining hydrotropic properties of the medium depends only on the degree of circular polarization of the intense wave. In the general case of the wave elliptic polarization, all tensor components are different. For example, the medium has both hydrotropic properties and the properties of biaxial crystals.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determining the CH{sub 3}SO{sub 2}{yields}CH{sub 3}+SO{sub 2} barrier from methylsulfonyl chloride photodissociation at 193 nm using velocity map imaging

These imaging experiments study the formation of the methylsulfonyl radical, CH{sub 3}SO{sub 2}, from the photodissociation of CH{sub 3}SO{sub 2}Cl at 193 nm and determine the energetic barrier for the radical's subsequent dissociation to CH{sub 3}+SO{sub 2}. We first state-selectively detect the angular and recoil velocity distributions of the Cl({sup 2}P{sub 3/2}) and Cl({sup 2}P{sub 1/2}) atoms to further refine the distribution of internal energy partitioned to the momentum-matched CH{sub 3}SO{sub 2} radicals. The internal energy distribution of the radicals is bimodal, indicating that CH{sub 3}SO{sub 2} is formed in both the ground state and low-lying excited electronic states. All electronically excited CH{sub 3}SO{sub 2} radicals dissociate, while those formed in the ground electronic state have an internal energy distribution which spans the dissociation barrier to CH{sub 3}+SO{sub 2}. We detect the recoil velocities of the energetically stable methylsulfonyl radicals with 118 nm photoionization. Comparison of the total recoil translational energy distribution for all radicals to the distribution obtained from the detection of stable radicals yields an onset for dissociation at a translational energy of 70{+-}2 kcal/mol. This onset allows us to derive a CH{sub 3}SO{sub 2}{yields}CH{sub 3}+SO{sub 2} barrier height of 14{+-}2 kcal/mol; this determination relies on the S-Cl bond dissociation energy, taken here as the CCSD(T) predicted energy of 65.6 kcal/mol. With 118 nm photoionization, we also detect the velocity distribution of the CH{sub 3} radicals produced in this experiment. Using the velocity distributions of the SO{sub 2} products from the dissociation of CH{sub 3}SO{sub 2} to CH{sub 3}+SO{sub 2} presented in the following paper, we show that our fastest detected methyl radicals are not from these radical dissociation channels, but rather from a primary S-CH{sub 3} bond photofission channel in CH{sub 3}SO{sub 2}Cl. We also present critical points on the ground state potential energy surface of CH{sub 3}SO{sub 2} at the //CCSD(T)/aug-cc-pV(Q+d)ZCCSD(T)/6-311++G(2df,p) level. We include harmonic zero-point vibrational corrections as well as core-valence and scalar-relativistic corrections. The CCSD(T) predicted barrier of 14.6 kcal/mol for CH{sub 3}SO{sub 2}{yields}CH{sub 3}+SO{sub 2} agrees well with our experimental measurement. These results allow us to predict the unimolecular dissociation kinetics of CH{sub 3}SO{sub 2} radicals and critique the analysis of prior time-resolved photoionization studies on this system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method of determining narrow energy spread electron beams from a laser plasma wakefield accelerator using undulator radiation

In this paper a new method of determining the energy spread of a relativistic electron beam from a laser-driven plasma wakefield accelerator by measuring radiation from an undulator is presented. This could be used to determine the beam characteristics of multi-GeV accelerators where conventional spectrometers are very large and cumbersome. Simultaneous measurement of the energy spectra of electrons from the wakefield accelerator in the 55-70 MeV range and the radiation spectra in the wavelength range of 700-900 nm of synchrotron radiation emitted from a 50 period undulator confirm a narrow energy spread for electrons accelerated over the dephasing distance where beam loading leads to energy compression. Measured energy spreads of less than 1% indicates the potential of using a wakefield accelerator as a driver of future compact and brilliant ultrashort pulse synchrotron sources and free-electron lasers that require high peak brightness beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density-based Energy Decomposition Analysis for Intermolecular Interactions with Variationally Determined Intermediate State Energies

The first purely density-based energy decomposition analysis (EDA) for intermolecular binding is developed within the density functional theory. The most important feature of this scheme is to variationally determine the frozen density energy, based on a constrained search formalism and implemented with the Wu-Yang algorithm [Q. Wu and W. Yang, J. Chem. Phys. 118, 2498 (2003) ]. This variational process dispenses with the Heitler-London antisymmetrization of wave functions used in most previous methods and calculates the electrostatic and Pauli repulsion energies together without any distortion of the frozen density, an important fact that enables a clean separation of these two terms from the relaxation (i.e., polarization and charge transfer) terms. The new EDA also employs the constrained density functional theory approach [Q. Wu and T. Van Voorhis, Phys. Rev. A 72, 24502 (2005)] to separate out charge transfer effects. Because the charge transfer energy is based on the density flow in real space, it has a small basis set dependence. Applications of this decomposition to hydrogen bonding in the water dimer and the formamide dimer show that the frozen density energy dominates the binding in these systems, consistent with the noncovalent nature of the interactions. A more detailed examination reveals how the interplay of electrostatics and the Pauli repulsion determines the distance and angular dependence of these hydrogen bonds.

08 HYDROGEN↗

New methodology for simultaneous volumetric and calorimetric measurements: Direct determination of {alpha}{sub p} and C{sub p} for liquids under pressure

A new batch cell has been developed to measure simultaneously both isobaric thermal expansion and isobaric heat capacity from calorimetric measurements. The isobaric thermal expansion is directly proportional to the linear displacement of an inner flexible below and the heat capacity is calculated from the calorimetric signal. The apparatus used was a commercial Setaram C-80 calorimeter and together with this type of vessels can be operated up to 20 MPa and in the temperature range of 303.15-523.15 K, In this work, calibration was carried out using 1-hexanol and subsequently both thermophysical properties were determined for 3-pentanol, 3-ethyl-3-pentanol, and 1-octanol at atmospheric pressure, 5 and 10 MPa, and from 303.15 to 423.15 K in temperature. Finally experimental values were compared with the literature in order to validate this new methodology, which allows a very accurate determination of isobaric thermal expansion and isobaric heat capacity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of explosive blast loading equivalencies with an explosively driven shock tube

Recently there has been significant interest in evaluating the potential of many different non-ideal energetic materials to cause blast damage. We present a method intended to quantitatively compare the blast loading generated by different energetic materials through use of an explosively driven shock tube. The test explosive is placed at the closed breech end of the tube and initiated with a booster charge. The resulting shock waves are then contained and focused by the tube walls to form a quasi-one-dimensional blast wave. Pressure transducers along the tube wall measure the blast overpressure versus distance from the source and allow the use of the one-dimensional blast scaling relationship to determine the energy deposited into the blast wave per unit mass of test explosive. These values are then compared for different explosives of interest and to other methods of equivalency determination.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Determination of layer-thickness variation in periodic multilayer by x-ray reflectivity

A method basically determining individual layer thicknesses in actual periodic multilayers has been developed, that solves simultaneous equations of positions of peaks appearing in wavelet transform curve of x-ray grazing incidence reflectivity. The determination was demonstrated on a Ni/C periodic multilayer fabricated by magnetron sputtering. Using the layer thicknesses obtained by the method, further accurate of thickness, roughness, and density of each layer was performed by Parratt's model. The special feature that the topmost and bottom-most layers were thicker than other layers was clearly observed. The former is attributed to oxidation and the latter is attributed to the effect of deposition on thick substrate. The mean fluctuations of other layers are 2.6% in C layers and 4.2% in Ni layers attributed to random fluctuations at deposition. Numerical analysis and statistical hypothesis tests have been carried out to discuss noncumulative and cumulative layer-thickness fluctuations in fabrication process.

36 MATERIALS SCIENCE↗

Submicrometer Single Crystal Diffractometry for Highly Accurate Structure Determination

Submicrometer single crystal diffractometry for highly accurate structure determination was developed using the extremely stable and highly brilliant synchrotron radiation from SPring-8. This was achieved using a microbeam focusing system and the submicrometer precision low-eccentric goniometer system. We demonstrated the structure analyses with 2x2x2 {mu}m{sup 3} cytidine, 600x600x300 nm{sup 3} BaTiO{sub 3}, and 1x1x1 {mu}m{sup 3} silicon. The observed structure factors of the silicon crystal were in agreement with the structure factors determined by the Pendelloesung method and do not require absorption and extinction corrections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Site-Selective Determination of Magnetic Helices in BaTiCoFe{sub 10}O{sub 19} by Resonant Magnetic Scattering

Synchrotron radiation intensity measurements were made for single crystals of ferrimagnetic BaTiCoFe{sub 10}O{sub 19} at the BL-6C(3A) beamline of the Photon Factory. The resonant x-ray magnetic scattering (RXMS) method at the Fe K edge makes it possible to determine the magnetic crystal structure, having the magnetic helices for Fe ions in tetrahedral 4f{sub 1}, bipyramidal 2b, and octahedral 2a, 4f{sub 2} and 12k sites. Based on the information on x-ray magnetic circular dichroism (XMCD) and a resonant magnetic scattering factor f''{sub m} ( = 0.23) estimated from BaFe{sub 12}O{sub 19} at E = 7128.2 eV, the magnetic structures have been determined from an asymmetrical ratio {Delta}R (Y{sup +}-Y{sup -})/(Y{sup +}+Y{sup -}), where Y{sup +} and Y{sup -} are scattering intensities for left- and right-circular polarizations, respectively. Spin orientations were estimated in the least-squares procedure to minimize a residual factor of {Sigma}({Delta}R{sub obs}-{Delta}R{sub calc}){sup 2}. The canting angles estimated in this study are 180 deg., 19 deg., 118 deg., 180 deg. and 65 deg. for the magnetic moments of Fe ions in 4f{sub 1}, 2b, 2a, 4f{sub 2} and 12k sites, respectively.

36 MATERIALS SCIENCE↗