Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Higher Chest Wall Dose Results in Improved Locoregional Outcome in Patients Receiving Postmastectomy Radiation

Purpose: Randomized trials demonstrating decreased locoregional recurrence (LRR) and improved overall survival (OS) in women receiving postmastectomy radiation therapy (PMRT) used up to 50 Gy to the chest wall (CW), but in practice, many centers boost the CW dose to {>=}60 Gy, despite lack of data supporting this approach. We evaluated the relationship between CW dose and clinical outcome. Methods and Materials: We retrospectively reviewed medical records of 582 consecutively treated patients who received PMRT between January 1999 and December 2009. We collected data on patient, disease, treatment characteristics, and outcomes of LRR, progression-free survival (PFS) and OS. Results: Median follow-up from the date of diagnosis was 44.7 months. The cumulative 5-year incidence of LRR as first site of failure was 6.2%. CW dose for 7% (43 patients) was {<=}50.4 Gy (range, 41.4-50.4 Gy) and 93% received >50.4 Gy (range, 52.4-74.4 Gy). A CW dose of >50.4 Gy vs. {<=}50.4 Gy was associated with lower incidence of LRR, a 60-month rate of 5.7% (95% confidence interval [CI], 3.7-8.2) vs. 12.7% (95% CI, 4.5-25.3; p = 0.054). Multivariate hazard ratio (HR) for LRR controlling for race, receptor status, and stage was 2.62 (95% CI, 1.02-7.13; p = 0.042). All LRR in the low-dose group occurred in patients receiving 50 to 50.4 Gy. Lower CW dose was associated with worse PFS (multivariate HR, 2.73; 95% CI, 1.64-4.56; p < 0.001) and OS (multivariate HR, 3.88; 95% CI, 2.16-6.99; p < 0.001). Conclusions: The addition of a CW boost above 50.4 Gy resulted in improved locoregional control and survival in this cohort patients treated with PMRT for stage II-III breast cancer. The addition of a CW boost to standard-dose PMRT is likely to benefit selected high-risk patients. The optimal technique, target volume, and patient selection criteria are unknown. The use of a CW boost should be studied prospectively, as has been done in the setting of breast conservation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reirradiation of Recurrent and Second Primary Head and Neck Cancer With Proton Therapy

Purpose: To report the clinical outcomes of head and neck reirradiation with proton therapy. Methods and Materials: From 2004 to 2014, 61 patients received curative-intent proton reirradiation, primarily for disease involving skull base structures, at a median of 23 months from the most recent previous course of radiation. Most had squamous cell (52.5%) or adenoid cystic (16.4%) carcinoma. Salvage surgery before reirradiation was undertaken in 47.5%. Gross residual disease was present in 70.5%. For patients with microscopic residual disease, the median dose of reirradiation was 66 Gy (relative biological effectiveness), and for gross disease was 70.2 Gy (relative biological effectiveness). Concurrent chemotherapy was given in 27.9%. Results: The median follow-up time was 15.2 months and was 28.7 months for patients remaining alive. The 2-year overall survival estimate was 32.7%, and the median overall survival was 16.5 months. The 2-year cumulative incidence of local failure with death as a competing risk was 19.7%; regional nodal failure, 3.3%; and distant metastases, 38.3%. On multivariable analysis, Karnofsky performance status ≤70%, the presence of a gastrostomy tube before reirradiation, and an increasing number of previous courses of radiation therapy were associated with a greater hazard ratio for death. A cutaneous primary tumor, gross residual disease, increasing gross tumor volume, and a lower radiation dose were associated with a greater hazard ratio for local failure. Grade ≥3 toxicities were seen in 14.7% acutely and 24.6% in the late setting, including 3 treatment-related deaths. Conclusions: Reirradiation with proton therapy, with or without chemotherapy, provided reasonable locoregional disease control, toxicity profiles, and survival outcomes for an advanced-stage and heavily pretreated population. Additional data are needed to identify which patients are most likely to benefit from aggressive efforts to achieve local disease control and to evaluate the potential benefit of proton therapy relative to other modalities of reirradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of volume loading and pressor agents in idiopathic orthostatic tachycardia

BACKGROUND: Idiopathic orthostatic tachycardia (IOT) is characterized by an increase in heart rate (HR) with standing of > or = 30 bpm that is associated with elevated catecholamine levels and orthostatic symptoms. A dynamic orthostatic hypovolemia and alpha1-adrenoreceptor hypersensitivity have been demonstrated in IOT patients. There is evidence of an autonomic neuropathy affecting the lower-extremity blood vessels. METHODS AND RESULTS: We studied the effects of placebo, the alpha1-adrenoreceptor agonist midodrine (5 to 10 mg), the alpha2-adrenoreceptor agonist clonidine (0.1 mg), and I.V. saline (1 L) in 13 patients with IOT. Supine and upright blood pressure (BP) and HR were measured before and at 1 and 2 hours after intervention. Midodrine decreased both supine and upright HR (all HR values are given as bpm) at 2 hours (from 78+/-2 supine to 108+/-5 upright before treatment and from 69+/-2 supine to 95+/-5 upright after treatment, P<.005 for supine and P<.01 for upright). Saline decreased both supine and upright HR (from 80+/-3 supine to 112+/-5 upright before infusion and from 77+/-3 supine to 91+/-3 upright 1 hour after infusion, P<.005 for supine and P<.001 for upright). Clonidine decreased supine HR (from 78+/-2 to 74+/-2, P<.03) but did not affect the HR increase with standing. Clonidine very significantly decreased supine systolic BP (from 109+/-3 at baseline to 99+/-2 mm Hg at 2 hours, P<.001), and midodrine decreased supine systolic BP mildly. CONCLUSIONS: IOT responds best acutely to saline infusion to correct the underlying hypovolemia. Chronically, this can be accomplished with increased salt and water intake in conjunction with fludrocortisone. The response of patients to the alpha1-agonist midodrine supports the hypothesis of partial dysautonomia and indicates that the use of alpha1-agonists to pharmacologically replace lower-extremity postganglionic sympathetics is an appropriate overall goal of therapy. These findings are consistent with our hypothesis that the tachycardia and elevated catecholamine levels associated with IOT are principally due to hypovolemia and loss of adequate lower-extremity vascular tone.

Non-NASA Center↗

Dose Escalated Liver Stereotactic Body Radiation Therapy at the Mean Respiratory Position

Purpose: The dosimetric impact of dose probability based planning target volume (PTV) margins for liver cancer patients receiving stereotactic body radiation therapy (SBRT) was compared with standard PTV based on the internal target volume (ITV). Plan robustness was evaluated by accumulating the treatment dose to ensure delivery of the intended plan. Methods and Materials: Twenty patients planned on exhale CT for 27 to 50 Gy in 6 fractions using an ITV-based PTV and treated free-breathing were retrospectively evaluated. Isotoxic, dose escalated plans were created on midposition computed tomography (CT), representing the mean breathing position, using a dose probability PTV. The delivered doses were accumulated using biomechanical deformable registration of the daily cone beam CT based on liver targeting at the exhale or mean breathing position, for the exhale and midposition CT plans, respectively. Results: The dose probability PTVs were on average 38% smaller than the ITV-based PTV, enabling an average ± standard deviation increase in the planned dose to 95% of the PTV of 4.0 ± 2.8 Gy (9 ± 5%) on the midposition CT (P<.01). For both plans, the delivered minimum gross tumor volume (GTV) doses were greater than the planned nominal prescribed dose in all 20 patients and greater than the planned dose to 95% of the PTV in 18 (90%) patients. Nine patients (45%) had 1 or more GTVs with a delivered minimum dose more than 5 Gy higher with the midposition CT plan using dose probability PTV, compared with the delivered dose with the exhale CT plan using ITV-based PTV. Conclusions: For isotoxic liver SBRT planned and delivered at the mean respiratory, reduced dose probability PTV enables a mean escalation of 4 Gy (9%) in 6 fractions over ITV-based PTV. This may potentially improve local control without increasing the risk of tumor underdosing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near-field radiative heat transfer between irregularly shaped dielectric particles modeled with the discrete system Green's function method

Near-field radiative heat transfer (NFRHT) between irregularly shaped dielectric particles made of SiO 2 and morphology characterized by Gaussian random spheres is studied. Particles are modeled using the discrete system Green's function (DSGF) approach, which is a volume integral numerical method based on fluctuational electrodynamics. This method is applicable to finite, three-dimensional objects, and all system interactions are defined independent of thermal excitation by a generalized system Green's function. The DSGF method is deemed suitable to model NFRHT between irregularly shaped particles after verification against the analytical solution for chains of two and three SiO 2 spheres. The NFRHT results reveal that geometric irregularity in particles leads to a reduction of the total conductance from that of comparable perfect spheres at vacuum separation distances smaller than the particle size, a regime in which NFRHT is a surface phenomenon. At vacuum separation distances larger than the particle size, NFRHT becomes a volumetric process, and the total conductance between irregularly shaped particles converges to that of comparable perfect spheres. Spectral analysis reveals, however, that particle irregularity leads to damping and broadening of resonances at all separation distances, thereby highlighting the importance of the DSGF method for spectral engineering in the near field. The reduced spectral coherence when particle size is larger than the vacuum separation distance is attributed to coupling of surface phonon-polaritons within the randomly generated, distorted particle features. For particle size smaller than the vacuum separation distance, resonance broadening and damping are linked with the multiple localized surface phonon modes supported by the composite spherical harmonic morphologies of the Gaussian random spheres. In conclusion, this paper has direct implications for thermal management of packed particle systems, with applications in radiative property control, electronics, energy conversion, and nanomanufacturing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mesoporous silica nanoparticles for biomedical and catalytical applications

Mesoporous silica materials, discovered in 1992 by the Mobile Oil Corporation, have received considerable attention in the chemical industry due to their superior textual properties such as high surface area, large pore volume, tunable pore diameter, and narrow pore size distribution. Among those materials, MCM-41, referred to Mobile Composition of Matter NO. 41, contains honeycomb liked porous structure that is the most common mesoporous molecular sieve studied. Applications of MCM-41 type mesoporous silica material in biomedical field as well as catalytical field have been developed and discussed in this thesis. The unique features of mesoporous silica nanoparticles were utilized for the design of delivery system for multiple biomolecules as described in chapter 2. We loaded luciferin into the hexagonal channels of MSN and capped the pore ends with gold nanoparticles to prevent premature release. Luciferase was adsorbed onto the outer surface of the MSN. Both the MSN and the gold nanoparticles were protected by poly-ethylene glycol to minimize nonspecific interaction of luciferase and keep it from denaturating. Controlled release of luciferin was triggered within the cells and the enzymatic reaction was detected by a luminometer. Further developments by varying enzyme/substrate pairs may provide opportunities to control cell behavior and manipulate intracellular reactions. MSN was also served as a noble metal catalyst support due to its large surface area and its stability with active metals. We prepared MSN with pore diameter of 10 nm (LP10-MSN) which can facilitate mass transfer. And we successfully synthesized an organo silane, 2,2'-Bipyridine-amide-triethoxylsilane (Bpy-amide-TES). Then we were able to functionalize LP10-MSN with bipyridinyl group by both post-grafting method and co-condensation method. Future research of this material would be platinum complexation. This Pt (II) complex catalyst has been reported for a C-H bond activation reaction as an alternative of the traditional Friedel-Crafts reaction. And we will compare the turnover numbers of MSN supported material with homogenous catalyst to evaluate the catalytical efficiency of our material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single and Multi-Node Modeling of Direct, Submerged, and Self-Pressurization of A Cryogenic Propellant Tank Using Nodal Tools

The pressurization of cryogenic propellant tanks will always be an important process so long as cryogenic liquids are being considered as fuel sources or used for other in-space applications. Pressure control of the tank ullage is necessary for managing propellant flowrates to an engine or a receiver tank, and modeling of the process is used to predict the pressurant requirements and the amount of propellant boiloff. Direct ullage pressurization is the more traditional approach to tank pressurization, as the physics are straight-forward, and ample test (flight) data have been collected and analyzed over the past several decades. Submerged injection pressurization is an alternate method for tank pressurization and has been shown to reduce pressurant requirements, subcool the propellant, and reduce the risk of ullage collapse. Additionally, the pressurant gas entering the ullage is usually much colder when using the submerged pressurization approach, resulting in reduced propellant boiloff. These benefits are at the expense of vaporizing a small percentage of the propellent. Both tank pressurization methods are viable options for current and future space missions, and it is important to have the capability of analyzing the tank ullage conditions for both approaches. Our previous work has demonstrated the development of a Generalized Fluid System Simulation Program (GFSSP) model, which contains a thermodynamic equilibrium heat and mass transfer subroutine capable of effectively analyzing both direct and submerged pressurization systems [1-2]. This subroutine has most recently been enhanced to include the non-equilibrium effect of pressurant dissolution into the propellant. To date the ullage has always been represented as a single node, and although the simulated single-node temperatures have good comparison with the volume-averaged ullage temperatures computed from test data, the physics of the thermal stratification in the ullage were never captured, and adjustment factors in the model were required. The purpose of this paper is to introduce the development of a multi-node ullage model using GFSSP and to discuss the improvements of the simulated ullage temperature distribution and its resulting effects on ullage heat transfer processes. Test data from the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) was used for model validation. For additional comparison, a Thermal Desktop (TD) model was also developed to analyze the CPST EDU direct ullage pressurization tests using both a single node and multi-node approach. The model includes the direct pressurant line, vent line, fill/drain line, and a TD FloCAD Compartment. The TD FloCAD Compartment is employed to represent the liquid and ullage as single volumes inside the tank, to include a liquid/vapor interface, and to generate network level objects such as lumps (analogous to nodes in GFSSP), paths, and ties between the fluid and thermal elements. An established heat load on the model tank was leveraged from a pre-existing higher-fidelity model correlated to CPST EDU test data.

pressurization↗

The risk of renal stone formation during and after long duration space flight

BACKGROUND: The formation of a renal stone during space flight may have serious negative effects on the health of the crewmember and the success of the mission. Urinary biochemical factors and the influence of dietary factors associated with renal stone development were assessed during long duration Mir Space Station missions. METHODS: Twenty-four-hour urine samples were collected prior to, during and following long duration space flight. The relative urinary supersaturation of calcium oxalate, calcium phosphate (brushite), sodium urate, struvite and uric acid were determined. RESULTS: Changes in the urinary biochemistry of crewmembers during long duration spaceflight demonstrated increases in the supersaturation of the stone-forming salts. In-flight hypercalciuria was evident in a number of individual crewmembers and 24-hour dietary fluid intake and urine volume were significantly lower. During flight, there was a significant increase in brushite supersaturation. CONCLUSIONS: These data suggest acute effects of space flight and postflight changes in the urinary biochemistry favoring increased crystallization in the urine. The effects of dietary intake, especially fluid intake, may have a significant impact on the potential for renal stone formation. Efforts are now underway to assess the efficacy of a countermeasure to mitigate the increased risk.

manned↗

Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of hydrogen sensor performance are being developed. Various commercial sensor platforms (e.g., thermal conductivity, catalytic and metal semiconductor) were used to demonstrate the advantages and issues with the flow through methodology.

14 SOLAR ENERGY↗

Oligometastases Treated With Stereotactic Body Radiotherapy: Long-Term Follow-Up of Prospective Study

Purpose: To analyze the long-term survival and tumor control outcomes after stereotactic body radiotherapy (SBRT) for metastases limited in number and extent. Methods and Materials: We prospectively analyzed the long-term overall survival (OS) and cancer control outcomes of 121 patients with five or fewer clinically detectable metastases, from any primary site, metastatic to one to three organ sites, and treated with SBRT. Freedom from widespread distant metastasis (FFDM) was defined as metastatic disease not amenable to local therapy (i.e., resection or SBRT). Prognostic variables were assessed using log-rank and Cox regression analyses. Results: For breast cancer patients, the median follow-up was 4.5 years (7.1 years for 16 of 39 patients alive at the last follow-up visit). The 2-year OS, FFDM, and local control (LC) rate was 74%, 52%, and 87%, respectively. The 6-year OS, FFDM, and LC rate was 47%, 36%, and 87%, respectively. From the multivariate analyses, the variables of bone metastases (p = .057) and one vs. more than one metastasis (p = .055) were associated with a fourfold and threefold reduced hazard of death, respectively. None of the 17 bone lesions from breast cancer recurred after SBRT vs. 10 of 68 lesions from other organs that recurred (p = .095). For patients with nonbreast cancers, the median follow-up was 1.7 years (7.3 years for 7 of 82 patients alive at the last follow-up visit). The 2-year OS, FFDM, and LC rate was 39%, 28%, and 74%, respectively. The 6-year OS, FFDM, and LC rate was 9%, 13%, and 65%, respectively. For nonbreast cancers, a greater SBRT target volume was significantly adverse for OS (p = .012) and lesion LC (p < .0001). Patients whose metastatic lesions, before SBRT, demonstrated radiographic progression after systemic therapy experienced significantly worse OS compared with patients with stable or regressing disease. Conclusions: Select patients with limited metastases treated with SBRT are long-term survivors. Future research should address the therapeutic benefit of SBRT for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-H-BRA-03: Development of a Model to Include the Evolution of Resistant Tumor Subpopulations Into the Treatment Optimization Process for Schedules Involving Targeted Agents in Chemoradiation Therapy

Purpose: To develop a model that includes the process of resistance development into the treatment optimization process for schedules that include targeted therapies. Further, to validate the approach using clinical data and to apply the model to assess the optimal induction period with targeted agents before curative treatment with chemo-radiation in stage III lung cancer. Methods: Growth of the tumor and its subpopulations is modeled by Gompertzian growth dynamics, resistance induction as a stochastic process. Chemotherapy induced cell kill is modeled by log-cell kill dynamics, targeted agents similarly but restricted to the sensitive population. Radiation induced cell kill is assumed to follow the linear-quadratic model. The validation patient data consist of a cohort of lung cancer patients treated with tyrosine kinase inhibitors that had longitudinal imaging data available. Results: The resistance induction model was successfully validated using clinical trial data from 49 patients treated with targeted agents. The observed recurrence kinetics, with tumors progressing from 1.4–63 months, result in tumor growth equaling a median volume doubling time of 92 days [34–248] and a median fraction of pre-existing resistance of 0.035 [0–0.22], in agreement with previous clinical studies. The model revealed widely varying optimal time points for the use of curative therapy, reaching from ∼1m to >6m depending on the patient’s growth rate and amount of pre-existing resistance. This demonstrates the importance of patient-specific treatment schedules when targeted agents are incorporated into the treatment. Conclusion: We developed a model including evolutionary dynamics of resistant sub-populations with traditional chemotherapy and radiation cell kill models. Fitting to clinical data yielded patient specific growth rates and resistant fraction in agreement with previous studies. Further application of the model demonstrated how proper timing of chemo-radiation could minimize the probability of resistance, increasing tumor control significantly.

60 APPLIED LIFE SCIENCES↗

Nanomaterials for LightManagement in Electro-Optical Devices

In the past decade, nanostructured materials and nanoparticles have emerged as the necessary ingredients for electrooptical applications and enhancement of device performance, in particular by making use of the light management aspects of the nanomaterials. The application areas that are being transformed profoundly include smart coating devices (e.g., electrochromic, photochromic, and thermochromic devices), solar energy, and sensing. Despite the large volume of work in the past on smart coating devices, and in particular on electrochromic devices and thermochromic fenestrations, for optical transmission or reflection control, applications remain limited because of slow response time and nonuniformity in the case of large surfaces. Recent works in the field indicate that nanostructured electrochromic coatings would be an integral part of the solution to the above problem. One aspect that can thus be focused on would be the fabrication and characterization of the nanostructured smart coating materials and their compatibility with other layers in the overall smart coating device. In the area of solar photovoltaics, nanomaterials have been used in designing light-trapping schemes for inorganic as well as organic solar cells. One particular category of solar cells that has attracted much interest is the plasmonic solar cells in which metallic nanoparticles are incorporated, helping in enhancing their energy conversion efficiency. Nanostructured solar cells would eventually develop into a 'game changing' technology for making solar cells that are affordable and highly efficient, providing a sizeable alternative energy source for our ever-increasing energy needs. Sensors based on the optical properties of constituting nanostructures and nanoparticles also form a most interesting class of bio- and electrochemical sensing devices. The possibility of synthetizing nanoparticles and structures of specifically desired sizes and shapes has indeed opened a whole new range of sensing applications. In parallel to the experimental development of nanomaterials for light management in devices, theoretical modeling and analysis have also accomplished much progress, and different methods for simulating the optical properties of nanoparticles and structures have been proposed. This special issue of the Journal of Nanomaterials is thus dedicated to articles dealing with nanostructured materials that can be used for light management purpose in different applications. Silicon-rich oxide (SRO) is a dielectric material that contains Si nanoparticles and exhibits interesting physical characteristics for applications in optoelectronic devices. The work by Aceves-Mijares et al. examine, in detail the electro-, cathode- and photoluminescence properties of SRO and discuss the origin of light emission in this type of materials. SRO films, of high and medium silicon excess density, obtained by low-pressure chemical vapor deposition and annealed at 1,100 C have been studied. Results obtained by the authors have led to conclude that SRO emission properties are due to oxidation state nanoagglomerates rather than to nanocrystals, and the emission mechanism is similar to that in the donor-acceptor decay in semiconductors with a specific wide emission spectrum. Two papers are devoted to nanostructured electrochromic thin films, a category of materials most suitable for controlling light transmission or absorption in electrooptical devices, including smart window coatings. Dinh et al. have shown that by mixing nanostructured Ti and W oxides films, one can obtain devices with considerable enhancement of electrochromic efficiency and electrochemical stability as compared to the conventional nonnanostructured films. As large-area mixed Ti and W oxides can be prepared by the simple doctor blade technique followed by an electrochemical process, this type of nanostructured electrochromic films can be considered a good candidate for smart window applications. Djaoued et al. have presented their studies on the synthesis, characterization, and electrochromic applications of porous WO{sub 3} thin films with different nanocrystalline phases. Asymmetric type electrochromic devices have been constructed using hexagonal, monoclinic, and orthorhombic porous WO{sub 3} thin porous films, and their enhanced electrochromic functionality has been well demonstrated. The paper on smart materials by Chen et al. presents the synthesis of thermochromic W-doped VO{sub 2} (monoclinic/rutile) nanopowders using a novel and simple solution-based process as opposed to other conventional techniques such as excimer laser-assisted metal organic deposition and magnetron sputtering. This simple process is based on the reaction of ammonium metavanadate (NH{sub 4}VO{sub 3}) and oxalic acid dihydrate (C{sub 2}H{sub 2}O{sub 4} {center_dot} 2H{sub 2}O) followed by addition of appropriate ammonium tungstate (N{sub 5}H{sub 37}W{sub 6}O{sub 24} {center_dot} H{sub 2}O).

14 SOLAR ENERGY↗

A Cost Effective System Design Approach for Critical Space Systems

NASA-JSC required an avionics platform capable of serving a wide range of applications in a cost-effective manner. In part, making the avionics platform cost effective means adhering to open standards and supporting the integration of COTS products with custom products. Inherently, operation in space requires low power, mass, and volume while retaining high performance, reconfigurability, scalability, and upgradability. The Universal Mini-Controller project is based on a modified PC/104-Plus architecture while maintaining full compatibility with standard COTS PC/104 products. The architecture consists of a library of building block modules, which can be mixed and matched to meet a specific application. A set of NASA developed core building blocks, processor card, analog input/output card, and a Mil-Std-1553 card, have been constructed to meet critical functions and unique interfaces. The design for the processor card is based on the PowerPC architecture. This architecture provides an excellent balance between power consumption and performance, and has an upgrade path to the forthcoming radiation hardened PowerPC processor. The processor card, which makes extensive use of surface mount technology, has a 166 MHz PowerPC 603e processor, 32 Mbytes of error detected and corrected RAM, 8 Mbytes of Flash, and I Mbytes of EPROM, on a single PC/104-Plus card. Similar densities have been achieved with the quad channel Mil-Std-1553 card and the analog input/output cards. The power management built into the processor and its peripheral chip allows the power and performance of the system to be adjusted to meet the requirements of the application, allowing another dimension to the flexibility of the Universal Mini-Controller. Unique mechanical packaging allows the Universal Mini-Controller to accommodate standard COTS and custom oversized PC/104-Plus cards. This mechanical packaging also provides thermal management via conductive cooling of COTS boards, which are typically designed for convection cooling methods.

Abbott, Larry Wayne↗

Prognostic Significance of Carbohydrate Antigen 19-9 in Unresectable Locally Advanced Pancreatic Cancer Treated With Dose-Escalated Intensity Modulated Radiation Therapy and Concurrent Full-Dose Gemcitabine: Analysis of a Prospective Phase 1/2 Dose Escalation Study

Purpose: Although established in the postresection setting, the prognostic value of carbohydrate antigen 19-9 (CA19-9) in unresectable locally advanced pancreatic cancer (LAPC) is less clear. We examined the prognostic utility of CA19-9 in patients with unresectable LAPC treated on a prospective trial of intensity modulated radiation therapy (IMRT) dose escalation with concurrent gemcitabine. Methods and Materials: Forty-six patients with unresectable LAPC were treated at the University of Michigan on a phase 1/2 trial of IMRT dose escalation with concurrent gemcitabine. CA19-9 was obtained at baseline and during routine follow-up. Cox models were used to assess the effect of baseline factors on freedom from local progression (FFLP), distant progression (FFDP), progression-free survival (PFS), and overall survival (OS). Stepwise forward regression was used to build multivariate predictive models for each endpoint. Results: Thirty-eight patients were eligible for the present analysis. On univariate analysis, baseline CA19-9 and age predicted OS, CA19-9 at baseline and 3 months predicted PFS, gross tumor volume (GTV) and black race predicted FFLP, and CA19-9 at 3 months predicted FFDP. On stepwise multivariate regression modeling, baseline CA19-9, age, and female sex predicted OS; baseline CA19-9 and female sex predicted both PFS and FFDP; and GTV predicted FFLP. Patients with baseline CA19-9 ≤90 U/mL had improved OS (median 23.0 vs 11.1 months, HR 2.88, P<.01) and PFS (14.4 vs 7.0 months, HR 3.61, P=.001). CA19-9 progression over 90 U/mL was prognostic for both OS (HR 3.65, P=.001) and PFS (HR 3.04, P=.001), and it was a stronger predictor of death than either local progression (HR 1.46, P=.42) or distant progression (HR 3.31, P=.004). Conclusions: In patients with unresectable LAPC undergoing definitive chemoradiation therapy, baseline CA19-9 was independently prognostic even after established prognostic factors were controlled for, whereas CA19-9 progression strongly predicted disease progression and death. Future trials should stratify by baseline CA19-9 and incorporate CA19-9 progression as a criterion for progressive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Outcome for Patients With Pathologic Node-Positive Prostate Cancer Treated With Intensity Modulated Radiation Therapy and Androgen Deprivation Therapy: A Case-Matched Analysis of pN1 and pN0 Patients

Purpose: Improved outcome is reported after surgery or external beam radiation therapy (EBRT) plus androgen deprivation therapy (ADT) for patients with lymph node (LN) positive (N1) prostate cancer (PC). Surgical series have shown that pathologic (p)N1 PC does not behave the same in all patients. The aim of this study was to perform a matched-case analysis to compare the outcome of pN1 and pN0 PC after high-dose EBRT plus ADT. Methods and Materials: Radiation therapy up to 80 Gy was delivered to the prostate with a minimal dose of 45 Gy to the pelvis for pN1 patients. After matching, Kaplan-Meier statistics were used to compare the 5-year biochemical and clinical relapse-free survival (bRFS and cRFS), prostate cancer–specific survival (PCSS), and overall survival (OS). Acute and late rectal and urinary toxicity was evaluated. Results: Sixty-nine pN1 PC patients were matched 1:1 with pN0 PC patients. The median follow-up time was 60 months. The 5-year bRFS and cRFS for pN1 versus pN0 PC patients were 65% ± 7% versus 79% ± 5% (P=.08) and 70% ± 6% versus 83% ± 5% (P=.04) respectively. No significant difference was found in bRFS or cRFS rates between low volume pN1 (≤2 positive LNs) and pN0 patients. The 5-year PCSS and OS were comparable between pN1 and pN0 PC patients: PCSS: 92% ± 4% versus 93% ± 3% (P=.66); OS: 82% ± 5% versus 80% ± 5% (P=.58). Severe toxicity was rare for both groups, although pN1 patients experienced significantly more acute grade 2 rectal toxicity. Conclusion: Primary EBRT plus 2 to 3 years of ADT is a legitimate treatment option for pN1 PC patients, especially those with ≤2 positive LNs, and this with bRFS and cRFS rates comparable to those in pN0 PC patients. For pN1 PC patients with >2 positive LNs, bRFS and cRFS are worse than in pN0 patients, but even in this subgroup, long-term disease control is obtained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗