Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “completely positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Advanced Modeling of Micromirror Devices

The flexure-beam micromirror device (FBMD) is a phase only piston style spatial light modulator demonstrating properties which can be used for phase adaptive corrective optics. This paper presents a complete study of a square FBMD, from advanced model development through final device testing and model verification. The model relates the electrical and mechanical properties of the device by equating the electrostatic force of a parallel-plate capacitor with the counter-acting spring force of the device's support flexures. The capacitor solution is derived via the Schwartz-Christoffel transformation such that the final solution accounts for non-ideal electric fields. The complete model describes the behavior of any piston-style device, given its design geometry and material properties. It includes operational parameters such as drive frequency and temperature, as well as fringing effects, mirror surface deformations, and cross-talk from neighboring devices. The steps taken to develop this model can be applied to other micromirrors, such as the cantilever and torsion-beam designs, to produce an advanced model for any given device. The micromirror devices studied in this paper were commercially fabricated in a surface micromachining process. A microscope-based laser interferometer is used to test the device in which a beam reflected from the device modulates a fixed reference beam. The mirror displacement is determined from the relative phase which generates a continuous set of data for each selected position on the mirror surface. Plots of this data describe the localized deflection as a function of drive voltage.

Michalicek, M. Adrian↗

Calibration of Gimbaled Platforms: The Solar Dynamics Observatory High Gain Antennas

Simple parameterization of gimbaled platform pointing produces a complete set of 13 calibration parameters-9 misalignment angles, 2 scale factors and 2 biases. By modifying the parameter representation, redundancy can be eliminated and a minimum set of 9 independent parameters defined. These consist of 5 misalignment angles, 2 scale factors, and 2 biases. Of these, only 4 misalignment angles and 2 biases are significant for the Solar Dynamics Observatory (SDO) High Gain Antennas (HGAs). An algorithm to determine these parameters after launch has been developed and tested with simulated SDO data. The algorithm consists of a direct minimization of the root-sum-square of the differences between expected power and measured power. The results show that sufficient parameter accuracy can be attained even when time-dependent thermal distortions are present, if measurements from a pattern of intentional offset pointing positions is included.

Hashmall, Joseph A.↗

Towards Autonomous Operation of Robonaut 2

The Robonaut 2 (R2) platform, as shown in Figure 1, was designed through a collaboration between NASA and General Motors to be a capable robotic assistant with the dexterity similar to a suited astronaut [1]. An R2 robot was sent to the International Space Station (ISS) in February 2011 and, in doing so, became the first humanoid robot in space. Its capabilities are presently being tested and expanded to increase its usefulness to the crew. Current work on R2 includes the addition of a mobility platform to allow the robot to complete tasks (such as cleaning, maintenance, or simple construction activities) both inside and outside of the ISS. To support these new activities, R2's software architecture is being developed to provide efficient ways of programming robust and autonomous behavior. In particular, a multi-tiered software architecture is proposed that combines principles of low-level feedback control with higher-level planners that accomplish behavioral goals at the task level given the run-time context, user constraints, the health of the system, and so on. The proposed architecture is shown in Figure 2. At the lowest-level, the resource level, there exists the various sensory and motor signals available to the system. The sensory signals for a robot such as R2 include multiple channels of force/torque data, joint or Cartesian positions calculated through the robot's proprioception, and signals derived from objects observable by its cameras.

Badger, Julia M.↗

Lessons Learned from Three Agrivoltaic Installations in New Jersey

Agrivoltaics is a new technology that has the potential to positively impact commercial farming by combining agricultural practices with the generation of solar energy. While some yield reduction is to be expected, resulting from less sunlight reaching the plant canopy and ground occupied by support structures, the generated electricity provides a low-risk supplemental income to farmers. In order to combine farming with electricity generation, agrivoltaic systems use a lower ground coverage ratio compared to normal solar farms and the PV panels are often mounted higher above the ground in order to facilitate the movement of agricultural equipment and to reduce the contrast between shaded and non-shaded areas. With funding provided from the state of New Jersey and the New Jersey Agricultural Experiment Station (NJAES), we designed and installed three unique agrivoltaic research systems at Rutgers/NJAES farms. These projects were recently completed and are generating electricity that is exported to the grid. This paper discusses the lessons we have learned along the way, including all the steps necessary to see an agrivoltaic project through to completion.

Both, A. J. (ORCID:0000000150845296)↗

SNC Meteorites, Organic Matter and a New Look at Viking

Recently, evidence has begun to grow supporting the possibility that the Viking GC-MS would not have detected certain carboxylate salts that could have been present as metastable oxidation products of high molecular weight organic species. Additionally, despite the instrument's high sensitivity, the possibility had remained that very low levels of organic matter, below the instrument's detection limit, could have been present. In fact, a recent study indicates that the degradation products of several million microorganisms per gram of soil on Mars would not have been detected by the Viking GC-MS. Since the strength of the GC-MS findings was considered enough to dismiss the biology packet, particularly the LR results, any subsequent evidence suggesting that organic molecules may in fact be present on the Martian surface necessitates a re-evaluation of the Viking LR data. In addition to an advanced mass spectrometer to look for isotopic signatures of biogenic processes, future lander missions will include the ability to detect methane produced by methanogenic bacteria, as well as techniques based on biotechnology. Meanwhile, the identification of Mars samples already present on Earth in the form of the SNC meteorites has provided us with the ability to study samples of the Martian upper crust a decade or more in advance of any planned sample return missions. While contamination issues are of serious concern, the presence of indigenous organic matter in the form of polycyclic aromatic hydrocarbons has been detected in the Martian meteorites ALH84001 and Nakhla, while there is circumstantial evidence for carbonaceous material in Chassigny. The radiochronological ages of these meteorites are 4.5 Ga, 1.3 Ga, and 165 Ma respectively representing a span of time in Earth history from the earliest single-celled organisms to the present day. Given this perspective on organic material, a biological interpretation to the Viking LR results can no longer be ruled out. In the LR experiment, a solution containing C-14 labeled organic compounds was injected into soil samples. The detection of radioactivity in the overhead space would indicate that one or more of the substrates had been chemically converted into a carbon-containing gas. To serve as a control, some samples were heated enough to destroy most known terrestrial microbes so that an indication for life would be a positive response from unheated samples and a negative response from heated samples. On Mars, the LR results had met minimum criteria for a biological interpretation but due to the GC-MS results, the LR responses were later attributed to putative soil inorganic oxidants. Since the time of Viking, studies have been carried out with the objective of determining an oxidant or combination of oxidants that might exist on Mars and have produced the observed kinetics of the LR response. To date, no such agent has been found that produces all aspects of the LR results on Mars. While the above considerations in no way imply the existence of life forms at the two Viking landing sites, inorganic and biological explanations for the Viking LR data should now be considered equally plausible until more complete studies of the Martian surface are carried out. Therefore, in light of the SNC meteorites data and their implications for the possibility of organic matter near or on the Martian surface the Viking biology experiments should thus be seen, not as failures for their inability to provide unambiguous evidence for or against Martian life, but as a foundation for the development of future life-detection instruments. Additional information is contained in the original extended abstract.

Warmflash, David M.↗

Cryogenic Fluid Management Using CFD - Development and Applications

The Fluid Dynamics Branch has positioned itself to support a wide range of customers in need of Cryogenic Fluid Management (CFM) analysis. A computational fluid dynamics (CFD) tool used for all manner of internal and external propulsion applications has been extended and refined to better model cryogenic propellant storage and tanking operations. Through the CFM Portfolio project, several validation activities were initiated. Validation of propellant tank self-pressurization, autogenous pressurization, slosh-induced ullage collapse, and jet-induced mixing all aid in defining model accuracy. The on-going validation effort has enabled confident application of the tool to in-line design and evaluation of CFM hardware and operations. Recent project support included design of no-vent fill operations using various techniques for the Human Landing System (HLS). Propellant transfer dynamics were predicted to ensure complete propellant delivery. Many more activities in support of HLS and other projects and programs were supported. The branch has engaged the CFM community to share recent findings and capabilities through conferences. To reach the wider community, a consolidation of fundamental findings from work on in-space pulsed settling maneuvers was distilled in an AIAA paper. Development and demonstration of CFM modeling capabilities continues in order to meet the needs of the agency and its industry partners in the endeavor to sustainably reach the Moon and beyond.

Jacob Brodnick↗

Lessons Learned from Three Agrivoltaic Installations in New Jersey

Agrivoltaics is a new technology that has the potential to positively impact commercial farming by combining agricultural practices with the generation of solar energy. While some yield reduction is to be expected, resulting from less sunlight reaching the plant canopy and ground occupied by support structures, the generated electricity provides a low-risk supplemental income to farmers. In order to combine farming with electricity generation, agrivoltaic systems use a lower ground coverage ratio compared to normal solar farms and the PV panels are often mounted higher above the ground in order to facilitate the movement of agricultural equipment and to reduce the contrast between shaded and non-shaded areas. With funding provided from the state of New Jersey and the New Jersey Agricultural Experiment Station (NJAES), we designed and installed three unique agrivoltaic research systems at Rutgers/NJAES farms. These projects were recently completed and are generating electricity that is exported to the grid. This paper discusses the lessons we have learned along the way, including all the steps necessary to see an agrivoltaic project through to completion.

14 SOLAR ENERGY↗

Lessons Learned from Three Agrivoltaic Installations in New Jersey

Agrivoltaics is a new technology that has the potential to positively impact commercial farming by combining agricultural practices with the generation of solar energy. While some yield reduction is to be expected, resulting from less sunlight reaching the plant canopy and ground occupied by support structures, the generated electricity provides a low-risk supplemental income to farmers. In order to combine farming with electricity generation, agrivoltaic systems use a lower ground coverage ratio compared to normal solar farms and the PV panels are often mounted higher above the ground in order to facilitate the movement of agricultural equipment and to reduce the contrast between shaded and non-shaded areas. With funding provided from the state of New Jersey and the New Jersey Agricultural Experiment Station (NJAES), we designed and installed three unique agrivoltaic research systems at Rutgers/NJAES farms. These projects were recently completed and are generating electricity that is exported to the grid. This paper discusses the lessons we have learned along the way, including all the steps necessary to see an agrivoltaic project through to completion.

14 SOLAR ENERGY↗

Solid State Reduction Driven Synthesis of Mn Containing Multi-principal Component Alloys

In recent years, high entropy alloys (HEAs), also known as multi-principal component alloys (MPCAs) have emerged as a new and exciting class of materials. This paper reports on the solid state reduction synthesis of a series of CoFeNiMn-based MPCA compositions, starting from a mixture of the corresponding oxides. One of the aims of the study was to test whether the degree of reduction of MnO, a highly stable oxide, could be enhanced by tailoring the alloy composition. Specifically, the influence of Ni content was studied because Ni exhibits a significant negative enthalpy of mixing with Mn. High purity precursor powders of Co(OH) 2 , Fe 2 O 3 , MnO 2 , and NiO were milled and mixed using standard ceramic processing methods. Here, the nominal sample compositions (assuming complete oxide reduction) were (CoFeMn) x Ni (1-x) , for x = 0, 0.083, 0.166, and 0.25. The oxide samples were subjected to a series of isothermal reduction anneals in flowing 3 pct H 2 –Ar at 1100 °C. The resulting microstructures were characterized using scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). The composition of the resulting MPCAs was determined quantitatively using wavelength dispersive spectroscopy (WDS) in the electron microprobe. The study revealed that for each of the initial oxide compositions studied, it was possible to achieve an MPCA with ~ 25 at. pct Mn. These results were found to be consistent with the predictions of a thermodynamic model whereby a negative enthalpy of mixing (ΔH mix ), combined with a contribution from configurational entropy, can offset a positive free energy of reduction (ΔG red ). The incorporation of vibrational entropy into first principles calculations was found to have a significant effect on the predicted crystal structure of the MPCAs.

36 MATERIALS SCIENCE↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Genomics, Exometabolomics, and Metabolic Probing Reveal Conserved Proteolytic Metabolism of Thermoflexus hugenholtzii and Three Candidate Species From China and Japan

Thermoflexus hugenholtzii JAD2 T , the only cultured representative of the Chloroflexota order Thermoflexales, is abundant in Great Boiling Spring (GBS), NV, United States, and close relatives inhabit geothermal systems globally. However, no defined medium exists for T. hugenholtzii JAD2 T and no single carbon source is known to support its growth, leaving key knowledge gaps in its metabolism and nutritional needs. Here, we report comparative genomic analysis of the draft genome of T. hugenholtzii JAD2 T and eight closely related metagenome-assembled genomes (MAGs) from geothermal sites in China, Japan, and the United States, representing “Candidatus Thermoflexus japonica,” “Candidatus Thermoflexus tengchongensis,” and “Candidatus Thermoflexus sinensis.” Genomics was integrated with targeted exometabolomics and 13 C metabolic probing of T. hugenholtzii. The Thermoflexus genomes each code for complete central carbon metabolic pathways and an unusually high abundance and diversity of peptidases, particularly Metallo- and Serine peptidase families, along with ABC transporters for peptides and some amino acids. The T. hugenholtzii JAD2 T exometabolome provided evidence of extracellular proteolytic activity based on the accumulation of free amino acids. However, several neutral and polar amino acids appear not to be utilized, based on their accumulation in the medium and the lack of annotated transporters. Adenine and adenosine were scavenged, and thymine and nicotinic acid were released, suggesting interdependency with other organisms in situ. Metabolic probing of T. hugenholtzii JAD2 T using 13 C-labeled compounds provided evidence of oxidation of glucose, pyruvate, cysteine, and citrate, and functioning glycolytic, tricarboxylic acid (TCA), and oxidative pentose-phosphate pathways (PPPs). However, differential use of position-specific 13 C-labeled compounds showed that glycolysis and the TCA cycle were uncoupled. Thus, despite the high abundance of Thermoflexus in sediments of some geothermal systems, they appear to be highly focused on chemoorganotrophy, particularly protein degradation, and may interact extensively with other microorganisms in situ.

59 BASIC BIOLOGICAL SCIENCES↗

AOPA Survey Summary of AGATE Concepts Demonstration October 17-19, 1996: Basic Report - Volume 1

An AGATE Concepts Demonstration was conducted at the Annual Aircraft Owners and Pilots Association (AOPA) Convention in 1996. The demonstration consisted of an interactive simulation of a single-pilot, single-engine aircraft in which the participant took off, flew a brief enroute segment and then flew a Global Positioning System (GPS) approach and landing. The participant was provided an advanced 'pathway-in-the-sky' presentation on both a head-up display and a head-down display to follow throughout the flight. A single lever power control and display concept was also provided for control of the engine throughout the flight. A second head-down, multifunction display in the instrument panel provided a moving map display for navigation purposes and monitoring of the status of the aircraft's systems. An estimated 352 people observed or participated in the demonstration, and 144 surveys were collected. The pilot ratings of the participants ranged from student to Air Transport Rating with an average of 1850 hours total flight time. The performance of the participants was surprisingly good, considering the minimal training in a completely new system concept. The overwhelming response was that technologies that simplify piloting tasks are enthusiastically welcomed by pilots of all experience levels. The increase in situation awareness and reduction in pilot workload were universally accepted and lauded as steps in the right direction.

Source record↗

AOPA Survey Summary of AGATE Concepts Demonstration, October 17-19, 1996: Original Survey Data - Volume 2

An AGATE Concepts Demonstration was conducted at the Annual Aircraft Owners and Pilots Association (AOPA) Convention in 1996. The demonstration consisted of an interactive simulation of a single-pilot, single-engine aircraft in which the participant took off, flew a brief enroute segment and then flew a Global Positioning System (GPS) approach and landing. The participant was provided an advanced 'pathway-in-the-sky' presentation on both a head-up display and a head-down display to follow throughout the flight. A single lever power control and display concept was also provided for control of the engine throughout the flight A second head-down, multifunction display in the instrument panel provided a moving map display for navigation purposes and monitoring of the status of the aircraft's systems. An estimated 352 people observed or participated in the demonstration, and 144 surveys were collected. The pilot ratings of the participants ranged from student to Air Transport Rating with an average of 1850 hours total flight time. The performance of the participants was surprisingly good, considering the minimal training in a completely new system concept. The overwhelming response was that technologies that simplify piloting tasks are enthusiastically welcomed by pilots of all experience levels. The increase in situation awareness and reduction in pilot workload were universally accepted and lauded as steps in the right direction.

Source record↗

Regulatory Mechanism of Muscle Disuse Atrophy in Adult Rats

During the last phase of NAG 2-386 we completed three studies. The effects of 14 days of weightlessness; the vastus medialis (VM) from flight rats in COSMOS 2044 was compared with the VM from tail suspended rats and other controls. The type I and II fibers in the mixed fiber portion of the VM were significantly reduced in flight rats and capillary densities paralleled the fiber density changes. The results of this project compared favorably with those in the extensor digitorum longus following seven days of flight in SL 3. The cardiovascular projects focused on the blood pressure changes in head down tilted rats (HDT) and non-head down tilted (N-HDT) rats. Blood pressures (MAP, SP and DP) were significantly elevated through seven days of HDT and rapidly returned to control levels within one day after removal from the HDT position. The N-HDT showed some slight rise in blood pressure but these were not as great and they were not as rapid. The HDT rats were characterized as exhibiting transient hypertension. These results led to some of the microvascular and vascular graduate student projects of Dr. Bernhard Stepke. Also our results refute or, at least, do not agree with previous reports from other laboratories. Each animal, in our blood pressure projects, served as its own control thereby providing more accurate results. Also, our experiments focused on recovery studies which can, in and of themselves, provide guidelines for flight experiments concerned with blood pressure changes. Another experiment was conducted to examine the role of testicular atrophy in whole body suspended (WBS) and tail suspended (TS) rats. We worked in conjunction with Dr. D.R. Deaver's laboratory at Pennsylvania State University and Dr. R. P. Amann at Colorado State University. In the TS rats the testes are retracted into the abdominal cavity, unless a ligature is placed to maintain them in the external scrotal sac. The cryptorchid condition in TS rats results in atrophy of the testes and lowered levels of spermatid formation. Hormonal changes due to testes atrophy must be considered in future experiments where related effects may modify muscle, bone or other tissue changes. Also, some new assessments of past results (published by many researchers) may warrant revised interpretations. The blood pressure studies and the testicular function results were presented and reviewed during an invited lecture at the University of Bordeaux II during the Animals in Space Symposium in March 1993. In summary, each of these three projects complied with the objectives of the proposal and serve to demonstrate the utility of animal models in preparations and interpretations of space flight results. All funding has been expended in accordance with the approved budget.

Source record↗

Global Energy and Water Budgets in MERRA

Reanalyses, retrospectively analyzing observations over climatological time scales, represent a merger between satellite observations and models to provide globally continuous data and have improved over several generations. Balancing the Earth s global water and energy budgets has been a focus of research for more than two decades. Models tend to their own climate while remotely sensed observations have had varying degrees of uncertainty. This study evaluates the latest NASA reanalysis, called the Modern Era Retrospective-analysis for Research and Applications (MERRA), from a global water and energy cycles perspective. MERRA was configured to provide complete budgets in its output diagnostics, including the Incremental Analysis Update (IAU), the term that represents the observations influence on the analyzed states, alongside the physical flux terms. Precipitation in reanalyses is typically sensitive to the observational analysis. For MERRA, the global mean precipitation bias and spatial variability are more comparable to merged satellite observations (GPCP and CMAP) than previous generations of reanalyses. Ocean evaporation also has a much lower value which is comparable to observed data sets. The global energy budget shows that MERRA cloud effects may be generally weak, leading to excess shortwave radiation reaching the ocean surface. Evaluating the MERRA time series of budget terms, a significant change occurs, which does not appear to be represented in observations. In 1999, the global analysis increments of water vapor changes sign from negative to positive, and primarily lead to more oceanic precipitation. This change is coincident with the beginning of AMSU radiance assimilation. Previous and current reanalyses all exhibit some sensitivity to perturbations in the observation record, and this remains a significant research topic for reanalysis development. The effect of the changing observing system is evaluated for MERRA water and energy budget terms.

Bosilovich, Michael G.↗

Evaluating Retention Index Score Assumptions to Refine GC–MS Metabolite Identification

As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Redefining Eligibility by Analyzing Canceled Intraoperative Radiotherapy as a Boost for Patients Undergoing Breast-Conserving Treatment

Background: Intraoperative radiotherapy (IORT) with a 50-kV x-ray is used for a tumor bed boost during breast-conserving surgery. This study evaluated the anatomicosurgical factors associated with cancellation of planned IORT. Methods: Patient eligibility for the study included age of 20 years or older, compatibility for lumpectomy, and ductal carcinoma in situ or stages 1–3 invasive carcinoma. All the patients underwent magnetic resonance imaging (MRI) and multidisciplinary team evaluations. Resection margins were assessed by frozen pathology. Pre- and intraoperative variables were compared between the IORT and IORT-cancellation groups. Results: A total of 434 patients underwent surgeries for IORT between August 2014 and December 2017. For 90 of these patients, IORT was canceled because of repeated positive margins leading to a large cavity or total mastectomy (n = 27), insufficient cavity-skin distance (n = 14), satellite lesions leading to a large cavity or total mastectomy (n = 12), MRI findings of a large primary tumor or uncertain margins leading to a large cavity (n = 6), cavity geometry unsuitable for IORT (n = 6), subareolar tumor extension (n = 6), tumor abutting the pectoralis muscle (n = 3), patient refusal (n = 5), intraoperative confirmation of bilateral breast cancer (n = 3) or benign pathology (n = 3), device malfunction (n = 3), or scheduling difficulty (n = 2). A tumor larger than 2 cm (P = 0.014) and the presence of satellite lesions (P = 0.014) were independent predictors of IORT cancellation. Conclusions: Surgical procedures resulting in large cavities were the leading cause of IORT cancellation. Multidisciplinary evaluations using MRI were critical for completion of IORT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Transport System Vacuum Simulations and LED Atom Tracker

MAGIS-100 is an experiment using atom interferometry on strontium atoms in a 100m vacuum chamber. The laser travels through a laser transport system (LTS) before going down the chamber. Two projects were completed over the course of the internship. One project was conducting vacuum simulations on the LTS to ensure it meets the experimental pressure requirement of 10-11 torr. This was done by characterizing the pressure profile with variations in pump size, pump spacing, and orifice size. The initial design of the LTS included one 30 L/s ion pump in the high vacuum (HV) region, a lens mount with holes of diameter 0.788”, and three 150 L/s ion pumps in the ultra-high vacuum (UHV) region. After adjusting these variables, it was concluded that the lens mount holes could be reduced to 0.200” in diameter and one 150 L/s ion pump in the UHV could be removed and still meet the experimental requirements. The other project was to design an LED atom tracker that shows the position of the strontium atoms in the 100m shaft. This will help with public outreach by allowing visitors to have a visual of the experiment. An Arduino Uno and Arduino Due were programmed using classical physics formulas to direct the RGB LED strips to flash in sync with the falling atoms. The requirements for powering and connecting the hardware were calculated and recommendations for scaling the system to 100m were made.

43 PARTICLE ACCELERATORS↗