Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Vacuum RF Breakdown of Accelerating Cavities in Multi-Tesla Magnetic Fields

Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures within multi-Tesla magnetic fields. The application of strong magnetic fields has been shown to lead to an increase in vacuum RF breakdown. This phenomenon imposes operational (i.e. gradient) limitations on cavities in ionization cooling channels, and has a bearing on the design and operation of other RF structures as well, such as photocathodes and klystrons. We present recent results from Fermilab's MuCool Test Area (MTA), in which 201 and 805 MHz cavities were operated at high power both with and without the presence of multi-Tesla magnetic fields. We present an analysis of damage due to breakdown in these cavities, as well as measurements related to dark current and their relation to a conceptual model describing breakdown phenomena.

43 PARTICLE ACCELERATORS↗

Dynamic Tuner Development for Medium β Superconducting Elliptical Cavities

The Facility for Rare Isotope Beams (FRIB) is developing a 5-cell 644 MHz β_{o}pt=0.65 elliptical cavity for a future linac energy upgrade to 400 MeV/u for the heaviest uranium ions. Superconducting elliptical cavities operated in continuous wave, such as the ones for FRIB, are prone to microphonics which can excite mechanical modes of the cavities. It has been shown that the detuning due to microphonics can be mitigated with the use of piezo actuators (fast tuner) as opposed to the costly option of increasing the input RF power. The FRIB slow/fast dynamic tuner will be based on the Fermilab experience with similar tuners like those developed for the linac coherent light source (LCLS) II and proton improvement plan (PIP) II. This paper will present the results of tuner properties on the bench.

43 PARTICLE ACCELERATORS↗

Development of Nb3Sn Coatings for Superconducting RF Cavities at Fermilab

Nb3Sn films are a promising alternative material for su-perconducting RF cavities, with proven high quality factors at medium fields and predictions for increased superheating field as well. In this contribution, we de-scribe the latest results from the Fermilab Nb3Sn SRF program. Early experiments have been focused on single cell 1.3 GHz cavities. We briefly review efforts to bring the parameters used in the coating process into a range where they produce uniform surfaces without regions showing signs of excess tin or thin/uncoated areas. We then present the latest cavity results, after modifications to the coating recipe based on feedback from film appear-ance and RF performance. These results show high Q0 at medium fields and a maximum field of ~18 MV/m.

43 PARTICLE ACCELERATORS↗

The Relation Between Field Flatness and the Passband Frequency in the Elliptical Cavities

A technique that predicts the field flatness of the operating pi-mode based on the passband frequency is highly desirable when the direct measurement of the field is not available. Such a technique was developed for the SNS-PPU cavity, a 6-cell SRF cavity whose field flatness is important for cold operation. In this paper, we will present the theory on the relations between field profile and passband frequencies of the arbitrary deformed cavities, the simulation studies, and comparison with the experimental measurements.

Park, G. -T.↗

The Need for Nb3Sn Coated Cu Cavities for Future Accelerators

Based on current efforts in the U.S. on the novel concept of parallel-feed RF accelerator structures, and in the U.S. and abroad in producing Nb3Sn films on either Cu or bronze, we rec-ommend that the Particle Physics community foster R&D in Superconducting Nb3Sn coated Cu RF Cavities instead of costly bulk Nb. The paper includes methods to process the coated cavi-ties at temperatures consistent with Cu retaining its shape. A devoted global effort in develop-ing Cu cavity structures coated with Nb3Sn would make the ILC or Higgs factories more afforda-ble and more likely to be built. Not only do parallel-feed RF structures enable both higher ac-celerating gradients and higher efficiencies, but they would be applicable to both Cu and Nb3Sn coated Cu cells. Increased effort on these two techniques would synergize expenditures to-wards progress, which will converge on the choice of technology for the RF of an ILC or any fu-ture accelerator. The current methods of Nb3Sn coatings on Cu or bronze can be geared also towards standard cavity cells. In conclusion, the use of distributed coupling structure topology within improved performance parameters together with Nb3Sn coating technology can lead to a paradigm shift for superconducting linacs, with higher gradient, higher temperature of opera-tion, and reduced overall costs for any future collider.

43 PARTICLE ACCELERATORS↗

The collaborative effects of intrinsic and extrinsic impurities in low RRR SRF cavities

The superconducting radio-frequency (SRF) community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing and material analysis reveals a microscopic picture of why low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. We performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of oxygen and nitrogen to the RF layer further improves performance through changes in the mean free path and impurity profile. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of SRF surface treatments.

43 PARTICLE ACCELERATORS↗

Results from extended range SRF cavity tuner tests for LCLS-II-HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all the tests the tuners successfully achieved a frequency shift of -565±80 kHz from the 1.3 GHz value. This study discusses the cavity frequency during each stage of assembly from the cryomodule string to when they are finally tested at 2 K. Monitoring the cavity frequency from this initial stage contributed in reaching this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

IMPACT OF MEDIUM TEMPERATURE HEAT TREATMENT ON FLUX TRAPPING SENSITIVITY IN SRF CAVITIES

The effect of mid-T heat treatment on flux trapping sensitivity was measured on several 1.3 GHz single cell cavities subjected to medium temperature vacuum annealing at temperature of 150 - 400 ?C for a duration of 3 hours. The cavity was cooldown with residual magnetic field ?0 and ?20 mG in Dewar with cooldown condition of full flux trapped. The quality factor as a function of accelerating gradient was measured. The results show the correlation between the treatment temperature, quality factor, and sensitivity to flux trapping. Sensitivity increases with increasing heat treatment temperatures within the range of (200 - 325 ?C/3h).Moreover, variations in the effective penetration depth ofthe magnetic field and the density of quasi-particles can occur,influencing alterations in the cavity?s electromagneticresponse and resonance frequency.

Dhakal, P.↗

Redesign of the End Group in the 3.9 GHz LCLS-II Cavity

Development and production of Linac Coherent Light Source II (LCLS-II) is underway. The central part of LCLS-II is a continuous wave superconducting RF (CW SCRF) electron linac. The 3.9 GHz third harmonic cavity similar to the XFEL design will be used in LCLS-II for linearizing the longitudinal beam profile*. The initial design of the 3.9 GHz cavity developed for XFEL project has a large, 40 mm, beam pipe aperture for better higher-order mode (HOM) damping. It is resulted in dipole HOMs with frequencies nearby the operating mode, which causes difficulties with HOM coupler notch filter tuning. The CW linac operation requires an extra caution in the design of the HOM coupler in order to prevent its possible overheating. In this paper we present the modified 3.9 GHz cavity End Group for meeting the LCLS-II requirements

43 PARTICLE ACCELERATORS↗

Particulate Study on Materials for Cleanroom Assembly of SRF Cavities

Reducing particulates is an important aspect for cleanroom operation. Knowing that it is impossible to completely eliminate all particulates in a clean room, efforts have been made to prevent particulate from entering SRF cavities during high pressure rinsing (HPR) and assembly. At Jefferson Lab, one practice to achieve this goal has been clamping covers to cavity open flanges during assembly. Several cover materials that have been used are examined and alternative candidate materials are under development. Clamps as a known particulate generator are carefully examined and cleaning efficiency of different methods is studied. Assembly and cover tests were done on a dummy flange as well as real cavity flanges, which may help further understand the generation of particulate during assembly. Authored by Jefferson Science Associates, LLC under U.S. DOE Contracts DE-AC05-06OR23177 and DE-AC02-76SF00515 for the LCLS-II Project.

Zhao, Liang↗

Design of a 1.3 GHz RF-Dipole Crabbing Cavity for International Linear Collider

The International Liner Collider (ILC) requires crabbing systems to increase the luminosity of the colliding electron and positron bunches. There are several frequency options for the crabbing cavity. We have designed a 1.3 GHz compact 1-cell and 2-cell rf-dipole crabbing cavity to compensate for luminosity degradation due to large crossing angle. This paper presents the 1-cell and 2-cell cavities designed to meet the current specifications including the fundamental power coupler and higher order mode couplers.

De Silva, S.U.↗

Standardization of ancillary installation tooling for SRF cavities at Fermilab

For assemblies of cavities in cleanrooms, single-use tooling systems are made for the alignment and installation of ancillary components such as couplers and bellows. To minimize the number of tooling sets created, a design has been created to standardize alignment features to allow for assembly of different components with one set of tooling. A prototype set of tooling has been developed to with the required degrees of freedom for multiple assemblies while minimizing deformation during the assembly process. Prototype designs have been created for PIP-II SSR2 and 650 Cavities and for AUP Crab Cavities. Using 3D printing, this tooling can be quickly adjusted to allow for different ancillary components. The development process and status of the design will be discussed.

Narug, C. [Fermilab]↗

Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab

PIP-II cryomodules use a computer vision system (H-BCAMs system) to monitor the alignment of SRF cavities and focusing lenses during assembly, testing, and operation. This contribution details the integration of the H-BCAMs into the Spoke Test Cryostat (STC) at Fermilab, which is utilized for cold testing SRF cavities prior to their integration into the string assembly. Thermal and structural finite element analyses were employed to estimate the cavities’ deformations, to be validated during cold testing in the STC using H-BCAMs. Notably, this marks the first instance of H-BCAMs integration into a cryostat and operation within a cryogenic environment.

43 PARTICLE ACCELERATORS↗

High pressure rinse simulations for PIP-II SRF cavities

The implementation of High Pressure Rinse (HPR) not only ensures thorough cleaning of the inner high purity niobium surface of Superconducting Radio Frequency (SRF) cavities but also unlocks their full potential for achieving peak performance. By effectively removing contaminants and impurities, HPR sets the stage for enhanced superconducting properties, improved energy efficiency, and superior operational stability. A simulation tool has been developed, facilitating the accurate prediction of both the quality and effectiveness of the rinsing process before its execution in the cleanroom. This tool, the focus of this paper, stands as a pivotal advancement in optimizing Superconducting Radio Frequency (SRF) cavity preparation. Furthermore, our paper will also present correlations with cavity cold testing results, demonstrating the practical applicability and reliability of the simulation predictions in real-world scenarios.

43 PARTICLE ACCELERATORS↗

RF AND MECHANICAL DESIGN OF A 915 MHz SRF CAVITY FOR CONDUCTION-COOLED CRYOMODULES

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi↗

Field-Emission Electron Source Embedded in a Field-Enhanced Conduction-Cooled Superconducting RF Cavity

We present simulations and experimental progress toward the development of a high-current electron source with the potential to deliver high charge electron bunches at GHz-level repetition rates. To achieve these goals electrons are generated through field-emission and the cathode is immersed in a conduction-cooled superconducting 650-MHz RF cavity. The field-emitters consist of microscopic silicon pyramids and have a typical enhancement factor of about 500. To trigger field-emission, the peak field inside the RF cavity of about 6 MV/m is further enhanced by placing the field-emitters on the top of a superconducting Nb rod inserted in the RF cavity. So far, we cannot control the duration of the electron bunches which is of the order of RF period. Also, the present cryo-cooler power of about 2 W limits the beam current to microamp level.

43 PARTICLE ACCELERATORS↗

6-D ELEMENT-BY-ELEMENT PARTICLE TRACKING WITH CRAB CAVITY PHASE NOISE AND WEAK-STRONG BEAM-BEAM INTERACTION FOR THE HADRON STORAGE RING OF THE ELECTRON-ION COLLIDER

The Electron Ion Collider (EIC) presently under construction at Brookhaven National Laboratory will collide polarized high energy electron beams with hadron beams with luminosities up to 10^34 cm?^2 s^?1 in center mass energy range of 20-140 GeV. Crab cavities are used to compensate the geometric luminosity due to a large crossing angle 25 mrad in the EIC. It was found that the phase noise in crab cavities will generate a significant emittance growth for the hadron beams. The phase noise tolerance from the analytical calculation is very small for the Hadron Storage Ring (HSR) of the EIC. In this article, we present our preliminary numerical simulation results with a 6-d symplectic particle tracking to determine the proton emittance growth rate with crab cavity phase noise and beam-beam interaction for the HSR.

Luo, Y.↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗