Enhancing the Useability of the IAEA's Physical Model: An Analysis of User Feedback

This study presents the results of Physical Model user interviews conducted with 12 people who have International Atomic Energy Agency (IAEA) safeguards experience. The goal of this report is to provide additional context for policy makers when prioritizing the needs of the IAEA regarding support for enhancements to the Physical Model. The interviews covered the general usability of the Physical Model, its effectiveness as a technical reference, and the scope and utility of the Physical Model's indicators and content. The key conclusions from these interviews are as follows: 1) The Physical Model is difficult to find and not well advertised. 2) The Physical Model can be difficult to use due to its format, which makes searching for information difficult, and lack of visual content. Therefore, the Physical Model should be supported in multiple formats (print, PDF, web) to maximize its usability for different stakeholders. 3) The scope of the Physical Model's content and indicators is likely sufficient, and translating indicators into other languages is unlikely to be worth the effort. 4) Despite its inefficiencies and other issues, the Physical Model in its current form is a vital (albeit under-utilized) resource for key stakeholders. 5) Despite its broad use case the Physical Model is not a catch-all tool and force-fitting the Physical Model into functions for which it has not been designed for would likely diminish its value. 6) It can be difficult to disentangle challenges related to the Physical Model and its usability from broader challenges at the Agency, such as general issues with communication and coordination. Based on these conclusions and considering the results of past studies on the Physical Model funded by NA-241, the analysis team developed a list of recommendations and associated actions for IAEA consideration. These recommendations are prioritized based on the assessed level of difficulty for the IAEA to implement a recommendation, emphasizing low hanging fruit then building to more ambitious changes to the Physical Model's format and content.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Uncertainty Quantification of CFD Model Assumptions Against Sonic Boom Noise Prediction of a Commercial Supersonic Transport

This paper presents the results of uncertainty modeling of sonic boom noise generation from commercial supersonic transport considering the Spalart-Allmaras (SA) turbulence modeling parameters as well as Mach number, angle of attack and altitude. Sample generation and analysis for this uncertainty model was performed by UQPCE, which is a software package developed at the NASA Langley Research Center. To build the uncertainty model, 42 cases of sonic boom noise calculation were performed. Computation of the ground noise can be briefly summarized in two steps. First, the near field pressure waveforms are sampled from CFD calculation using the NASA Langley’s FUN3D solver. Second, this information is passed to an atmospheric propagation code, sBOOM, which solves an augmented Burger’s equation and simulates how the near field waveforms will change while passing through the atmosphere. The ground signature is further processed to obtain the perceived loudness, PLdB. Having a high spatial resolution near the shockwave in the CFD calculation is critical in sonic boom noise prediction. Because the variation in the input parameters for the current uncertainty quantification (UQ) study is likely to lead to change in shock location, angle and strength, the grid adaptation for shock capturing is independently applied for each condition. The final mesh used in the CFD calculation consists of approximately 420 million cells. The pressure signatures are sampled at three, four and five body lengths away from the aircraft to make sure the three dimensional effects around the aircraft are resolved. The results of the UQ analysis shows that within the three aleatory variables, the angle of attack had the most impact against ground noise, followed by the altitude and the Mach number. Between the two SA model parameters, the Kármán constant (𝜅) was significantly more important than the turbulent Prandtl number (𝜎), but these two parameters were only marginally significant in the overall prediction variance in ground noise. The UQ procedure explained in this paper can be widely applied to other model parameters.

Uncertainty Quantification↗

Synthesis, crystal and electronic structure of the Zintl phase Ba 16 Sb 11 . A case study uncovering greater structural complexity via monoclinic distortion of the tetragonal Ca 16 Sb 11 structure type

The binary Zintl phase Ba 16 Sb 11 has been synthesized and structurally characterized. Detailed studies via single-crystal X-ray diffraction methods indicate that although Ba 16 Sb 11 appears to crystallize in the tetragonal Ca 16 Sb 11 structure type (space group $P\bar{4}2_1$m with a=13.5647(9) Å, c=12.4124(12)Å, Z=2, R 1 = 3.14%; wR 2 = 4.77%), there exists an extensive structural disorder. Some Ba 16 Sb 11 crystals were found to be monoclinic and the structure was solved and refined in space group P2 1 (a=18.3929(12) Å, b=13.5233(8) Å, c=18.3978(12) Å, β=94.6600(10)°; Z=4, R 1 =5.84 %; wR 2 =9.58 %). The latter corresponds to a 2-fold superstructure of the tetragonal one, which provides a disorder-free structural model. In both descriptions, the disordered tetragonal and the ordered monoclinic superstructure, the basic building units that make up the structure of this Ba-rich compound are pairs of face-shared square antiprisms of Ba atoms, which are centered by Sb atoms. The dimerized antiprisms are linked into parallel chains via square prisms of Ba atoms, which are also centered by Sb atoms. The Zintl concept can be applied in a straightforward manner and as result, the structure of Ba 32 Sb 22 (=2×Ba 16 Sb 11 ) can be rationalized as (Ba 2+ ) 32 (Sb 3– ) 20 [Sb 2 ] 4– . Notably, the partitioning of the valence electrons is done taking into an account the homoatomic Sb–Sb contacts (d=3.01 Å), which can be clearly distinguished in the lower symmetry space group. Electronic structure calculations of Ba 16 Sb 11 are in good accordance with the Zintl rationalization and predict a semiconductor with a band gap of 0.77 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-state diffusion in amorphous zirconolite

We discuss how structural disorder and amorphization affect solid-state diffusion, and consider zirconolite as a currently important case study. By performing extensive molecular dynamics simulations, we disentangle the effects of amorphization and density, and show that a profound increase of solid-state diffusion takes place as a result of amorphization. Importantly, this can take place at the same density as in the crystal, representing an interesting general insight regarding solid-state diffusion. We find that decreasing the density in the amorphous system increases pre-factors of diffusion constants, but does not change the activation energy in the density range considered. We also find that atomic species in zirconolite are affected differently by amorphization and density change. Our microscopic insights are relevant for understanding how solid-state diffusion changes due to disorder and for building predictive models of operation of materials to be used to encapsulate nuclear waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Barrier-Certificated Reinforcement Learning Approach for Enhancing Power System Transient Stability

Increasing integration of renewable resources brings more flexibility and poses new challenges to modern power systems, leading to highly nonlinear and complex dynamics. Here, this paper aims to provide a general solution framework to traditional control problems, such as frequency control and voltage control, which attempt to maintain the stability of either synchronous generators-governed or inverter-governed systems when subjected to a disturbance and simultaneously guarantee operational constraints, providing a complete complement to existing works on control design. Building on reinforcement learning (RL) and control barrier functions, the framework includes two subsystems, i.e., a model-free controller and a barrier-certification system, which discover RL-based control actions and sequentially filter them using a barrier certificate to satisfy operational constraints. Calculating a barrier function is generally challenging for a complex power system. This is addressed by representing the barrier function using neural networks (NNs) and data-based approaches. An adaptive method is introduced to certify the neural barrier function that perseveres barrier conditions, which is more compatible with online implementation. The proposed framework synthesizes a stabilizing controller that satisfies predefined safety regions. The effectiveness of the proposed framework is demonstrated via several comparative case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Avista’s Shared Energy Economy Model Pilot: A Techno-economic Assessment

As part of the second round of the Washington Clean Energy Fund, Avista Corp received a $3.5 million matching grant in support of a shared energy economy project to test the integration of energy assets–from rooftop solar and battery storage to building energy management systems–that can be shared and used for multiple purposes. The goal of this project is to demonstrate how both the customer and the utility can benefit from this shared energy economy model and demonstrate that the electric grid can become more reliable, efficient, resilient, and flexible. Pacific Northwest National Laboratory was engaged by the U.S. Department of Energy and the Washington State Department of Commerce to work with Avista in assessing the benefits of the shared energy economy model. This report documents the techno-economic assessment of the shared energy economy model, including the definition of use cases and applications, collection and preparation of data and input parameters, development of modeling and optimization methods, and case studies and analysis results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Uncertainty Quantification of CFD Model Assumptions Against Sonic Boom Noise Prediction of a Commercial Supersonic Transport

This paper presents the results of uncertainty modeling of sonic boom noise generation from commercial supersonic transport considering the Spalart-Allmaras (SA) turbulence modeling parameters as well as Mach number, angle of attack and altitude. Sample generation and analysis for this uncertainty model was performed by UQPCE, which is a software package developed at the NASA Langley Research Center. To build the uncertainty model, 42 cases of sonic boom noise calculation were performed. Computation of the ground noise can be briefly summarized in two steps. First, the near field pressure waveforms are sampled from CFD calculation using the NASA Langley’s FUN3D solver. Second, this information is passed to an atmospheric propagation code, sBOOM, which solves an augmented Burger’s equation and simulates how the near field waveforms will change while passing through the atmosphere. The ground signature is further processed to obtain the perceived loudness, PLdB. Having a high spatial resolution near the shock wave in the CFD calculation is critical in sonic boom noise prediction. Because the variation in the input parameters for the current uncertainty quantification (UQ) study is likely to lead to change in shock location, angle and strength, the grid adaptation for shock capturing is independently applied for each condition. The final mesh used in the CFD calculation consists of approximately 420 million cells. The pressure signatures are sampled at three, four and five body lengths away from the aircraft to make sure the three dimensional effects around the aircraft are resolved. The results of the UQ analysis shows that within the three aleatory variables, the angle of attack had the most impact against ground noise, followed by the altitude and the Mach number. Between the two SA model parameters, the Kármán constant (𝜅) was significantly more important than the turbulent Prandtl number (𝜎), but these two parameters were only marginally significant in the overall prediction variance in ground noise. The UQ procedure explained in this paper can be widely applied to other model parameters.

Uncertainty Quantifications↗

Business Case for Nonintrusive Load Monitoring

This report explores how utilities, researchers, and consumers could benefit from a lower cost approach to submetering using non-intrusive load monitoring (NILM). NILM is a process of using data from a single point of monitoring, such as a utility smart meter, to provide an itemized accounting of end use energy consumption in residential and small commercial buildings. Pacific Northwest National Laboratory (PNNL) prepared this report for the Bonneville Power Administration (BPA). PNNL participated in an advisory group as part of a research project sponsored by the U.S. Department of Energy (DOE), the Bonneville Power Administration, and the State of Washington. The Electric Power Research Institute (EPRI) convened the advisory committee for two workshops held to identify ways in which NILM may be used. PNNL, on behalf of DOE, helped to cosponsor the first of these workshops. Results of an end-use monitoring study of a bank branch conducted by PNNL are also presented for purposes of illustrating the need for better data in energy savings modeling (DOE 2013a).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grain structure and texture selection regimes in metal powder bed fusion

Additive manufacturing (AM) offers opportunities to produce complex part geometries not possible with conventional processing and in some cases even improve part performance. However, adoption has been slowed by difficulties assessing microstructure variability and there is no straightforward approach to relate processing to grain structure characteristics. In this study, datasets from AdditiveFOAM heat transport simulations of laser powder bed fusion (LPBF) are used to drive ExaCA simulations of grain structure. The GPU utilization of ExaCA and an algorithmic update for modeling melt pool overlap region solidification enabled rapid and parallel simulation across a wider range of process conditions than previously explored with cellular automata-based solidification models. A texture selection angle $θ_s$ is defined based on melt pool overlap geometry, and the range of $θ_s$ over which a commonly observed texture transition occurs in characterized AM builds was well-reproduced by ExaCA simulations over a wide range of melt pool shape, hatch spacing, and layer height. ExaCA simulations with 90 degree rotation of the scan direction on every other layer reproduced a number of trends from the AM literature including grain refinement, the dominance of layers with larger melt pools on the final grain structure, and the weakening or strengthening of texture depending on odd and even layer melt pool overlap geometry. EBSD data from a benchmark AM part is used to validate the simulated mechanism of a layer rotation-induced texture strengthening effect. Importantly, these results expand the understanding of the mechanisms for texture selection in alloys with cubic crystal symmetry and offer an approach to easily evaluate processing conditions. With this new understanding, these modeling tools will enable anticipation of previously unexpected variations in grain structure and target specific microstructures and properties.

36 MATERIALS SCIENCE↗

Design of porphyrin-based ligands for the assembly of [d-block metal : calcium] bimetallic centers

The association of different metals in stable, well-defined molecular assemblies remains a great challenge of supramolecular chemistry. In such constructs, the emergence of synergism, or cooperative effects between the different metal centers is particularly intriguing. These effects can lead to uncommon reactivity or remarkable physico-chemical properties that are not otherwise achievable. For example, the association of alkaline or alkaline-earth cations and transition metals is pivotal for the activity of several biomolecules and human-made catalysts that carry out fundamental redox transformations (water oxidation, nitrogen reduction, water–gas shift reaction, etc.). In many cases the precise nature of the interactions between the alkaline-earth cations and the redox-active transition metals remains elusive due to the difficulty of building stable molecular heterometallic assemblies that associate transition metals and alkaline or alkaline-earth cations in a controlled way. In this work we present the rational design of porphyrin-based ligands possessing a second binding site for alkaline-earth cations above the porphyrin macrocycle primary complexation site. We demonstrate that by using a combination of crown ether and carboxylic acid substituents suitably positioned on the periphery of the porphyrin, bitopic ligands can be obtained. The binding of calcium, a typical alkaline-earth cation, by the newly prepared ligands has been studied in detail and we show that a moderately large binding constant can be achieved in protic media using ligands that possess some degree of structural flexibility. The formation of Zn–Ca assemblies discussed in this work is viewed as a stepping stone towards the assembly of well defined molecular transition metal-alkaline earth bimetallic centers using a versatile organic scaffold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-131: Artificial Neural Networks Applied to Overall Survival Prediction for Patients with Periampullary Carcinoma

Purpose: Artificial neural networks (ANN) can be used to discover complex relations within datasets to help with medical decision making. This study aimed to develop an ANN method to predict two-year overall survival of patients with peri-ampullary cancer (PAC) following resection. Methods: Data were collected from 334 patients with PAC following resection treated in our institutional pancreatic tumor registry between 2006 and 2012. The dataset contains 14 variables including age, gender, T-stage, tumor differentiation, positive-lymph-node ratio, positive resection margins, chemotherapy, radiation therapy, and tumor histology.After censoring for two-year survival analysis, 309 patients were left, of which 44 patients (∼15%) were randomly selected to form testing set. The remaining 265 cases were randomly divided into training set (211 cases, ∼80% of 265) and validation set (54 cases, ∼20% of 265) for 20 times to build 20 ANN models. Each ANN has one hidden layer with 5 units. The 20 ANN models were ranked according to their concordance index (c-index) of prediction on validation sets. To further improve prediction, the top 10% of ANN models were selected, and their outputs averaged for prediction on testing set. Results: By random division, 44 cases in testing set and the remaining 265 cases have approximately equal two-year survival rates, 36.4% and 35.5% respectively. The 20 ANN models, which were trained and validated on the 265 cases, yielded mean c-indexes as 0.59 and 0.63 on validation sets and the testing set, respectively. C-index was 0.72 when the two best ANN models (top 10%) were used in prediction on testing set. The c-index of Cox regression analysis was 0.63. Conclusion: ANN improved survival prediction for patients with PAC. More patient data and further analysis of additional factors may be needed for a more robust model, which will help guide physicians in providing optimal post-operative care. This project was supported by PA CURE Grant.

60 APPLIED LIFE SCIENCES↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life cycle impact assessment of home energy management systems (HEMS) using dynamic emissions factors for electricity in Finland

Decarbonising the European economy is a long-term goal in which the residential sector will play a significant role. Smart buildings for energy management are one means of decarbonisation, by reducing energy consumption and related emissions. This study investigated the environmental impacts of smart house automation using life cycle impact assessment. The ReCiPe method was selected for use, in combination with dynamic emissions factors for electricity in Finland. The results indicated that a high level of technology deployment may be counter-effective, due to high electricity consumption by the sensor network, automation system and computing devices. The results also indicated that number of inhabitants per household directly affected the environmental impacts of home automation. A single-person household saw its environmental impacts increase by 15%, while those of a five-person household increased by 3% in the worst-case scenario. The manufacturing phase contributed the major share of environmental impacts, exceeding the use phase in multiple categories. These findings indicate that finding the sweet spot in which technology can promote decarbonisation will be crucial to achieving the goal of a low‑carbon economy. - Highlights: •HEMS did not reduce the overall environmental impact of households. •Environmental impacts of HEMS are greater for single inhabitant households. •Energy efficiency of sensing devices must drastically increase to promote decarbonisation. •The highest life cycle environmental impacts of electronics are during the manufacturing phase. •Raising awareness is a critical part in decreasing the environmental impact of households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DOE Zero Energy Ready Home Case Study: Durable Energy Builders - Houston, Texas

This case study describes a DOE Zero Energy Ready Home in Houston, Texas, that scored HERS 39 without PV and HERS 29 with PV. This 5,947 ft2 custom home has 11.5-inch ICF walls. The attic is insulated along the roof line with 5 to 7 inches of open-cell spray foam. Most of the home's drinking water is supplied by a 11,500-gallon rainwater cistern. Hurricane strapping connects the roof to the walls. The triple-pane windows are impact resistant. The foundation is a raised slab.

builder↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.