Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Volume measurement of cryogenic deuterium pellets by Bayesian analysis of single shadowgraphy images

In situ commissioning of the Blower-gun injector for launching cryogenic deuterium pellets at ASDEX Upgrade tokamak was performed. This injector is designed for high repetitive launch of small pellets for edge localised modes pacing experiments. During the investigation the final injection geometry was simulated with pellets passing to the torus through a 5.5 m long guiding tube. For investigation of pellet quality at launch and after tube passage laser flash camera shadowgraphy diagnostic units before and after the tube were installed. As indicator of pellet quality we adopted the pellet mass represented by the volume of the main remaining pellet fragment. Since only two-dimensional (2D) shadow images were obtained, a reconstruction of the full three-dimensional pellet body had to be performed. For this the image was first converted into a 1-bit version prescribing an exact 2D contour. From this contour the expected value of the volume was calculated by Bayesian analysis taking into account the likely cylindrical shape of the pellet. Under appropriate injection conditions sound pellets with more than half of their nominal mass are detected after acceleration; the passage causes in average an additional loss of about 40% to the launched mass. Analyzing pellets arriving at tube exit allowed for deriving the injector's optimized operational conditions. For these more than 90% of the pellets were arriving with sound quality when operating in the frequency range 5-50 Hz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Insect Wing Displacement Measurement Using Digital Holography

Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and initial operation of multichord soft x-ray detection arrays on the STOR-M tokamak

Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft x-ray emission have been designed and installed on the STOR-M tokamak. Each array consists of a photodiode array, with one array viewing vertically and one viewing horizontally through a plasma cross section. Preamplifiers with fixed gains of 10{sup 5} V/A and custom built amplifiers with variable gains are used for signal amplification. Digitizers with 14 bit resolution and 3 MS/s sampling rate are used for data acquisition. In the initial operation, an Al foil with a thickness of 1.8 {mu}m installed for one array and Be filter of 7.6 {mu}m installed for the other array are used to test signal strength. Initial tests have identified sawtooth oscillations and 20 kHz fluctuations, which are also detected by Mirnov coils, superimposed on the sawtooth oscillations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the epistemic view of quantum states

We investigate the strengths and limitations of the Spekkens toy model, which is a local hidden variable model that replicates many important properties of quantum dynamics. First, we present a set of five axioms that fully encapsulate Spekkens' toy model. We then test whether these axioms can be extended to capture more quantum phenomena by allowing operations on epistemic as well as ontic states. We discover that the resulting group of operations is isomorphic to the projective extended Clifford group for two qubits. This larger group of operations results in a physically unreasonable model; consequently, we claim that a relaxed definition of valid operations in Spekkens' toy model cannot produce an equivalence with the Clifford group for two qubits. However, the new operations do serve as tests for correlation in a two toy bit model, analogous to the well known Horodecki criterion for the separability of quantum states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a new Nd:YAG Thomson scattering system for MAST

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with {approx_equal}10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 deg. to 120 deg. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 512-Channel Module for Digital X-Ray Imaging Systems with Silicon Strip Detectors

We present the development of a 512-channel module for high counting rate digital X-ray imaging systems. The module consists of 512 silicon micro-strips equipped with 8 64-channel readout ASICs called DEDIX. The detectors of 300 {mu}m thickness have strips with 100 micron pitch and strip length of 1 or 2 cm. Detectors were designed with the possibility of choosing the cutting edge distance from the active area in the range from 60 {mu}m down to 20 {mu}m. To obtain good detection efficiency at the relevant energies (10-50 keV) the module works in edge-on configuration: strips are oriented parallel to the incoming X-ray beam. The DEDIX ASIC has a binary readout architecture. Each channel is built of a charge sensitive amplifier (CSA) with pole-zero cancellation circuit, a shaper, two independent discriminators and two independent 20-bit counters. Internal correction DAC implemented in each channel independently ensures a low spread of discriminator effective threshold. This module has been characterized for noise and matching performance having in mind possible future applications like dual energy mammography and angiography. An equivalent noise charge is below 210 el rms for a 1 cm long strip detector and below 250 el. rms for 2 cm long strip detector with 100 {mu}m pitch. The spread of discriminator effective threshold for 512 channels is 16 el. rms, while the high counting rate performance has been demonstrated by the measurement up to 1 MHz average rate of input signals per single channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar patterned media fabricated by ion irradiation into CrPt{sub 3} ordered alloy films

Planar patterned media using CrPt{sub 3} ordered alloy films were fabricated by Ar{sup +} or Kr{sup +} ion irradiation through nanoimprinted or electron beam lithography made masks. CrPt{sub 3} ordered alloy film on fused quartz substrate exhibits a large perpendicular anisotropy of 5x10{sup 6} erg/cc and a large coercivity of 12 kOe, and we found that its magnetic order (magnetization) was completely suppressed by a quite low Ar{sup +} or Kr{sup +} ion dose of about 1-2x10{sup 14} ions/cm{sup 2}. Magnetic force microscope image of the ion-beam patterned CrPt{sub 3} with a bit size of 90x90 nm showed clear magnetic contrast in nonirradiated regions, while no magnetic contrast in irradiated regions. The read-back waveform taken from an ion-beam patterned CrPt{sub 3} disk with 600 nm patterning pitch showed sharp signal transition between irradiated and nonirradiated regions, which indicates the possibility of high-density planar patterned media using CrPt{sub 3} ordered alloy.

36 MATERIALS SCIENCE↗

Reconstruction of Time-Resolved Neutron Energy Spectra in Z-Pinch Experiments Using Time-of-flight Method

We present the reconstruction of neutron energy spectra from time-of-flight signals. This technique is useful in experiments with the time of neutron production in the range of about tens or hundreds of nanoseconds. The neutron signals were obtained by a common hard X-ray and neutron fast plastic scintillation detectors. The reconstruction is based on the Monte Carlo method which has been improved by simultaneous usage of neutron detectors placed on two opposite sides from the neutron source. Although the reconstruction from detectors placed on two opposite sides is more difficult and a little bit inaccurate (it followed from several presumptions during the inclusion of both sides of detection), there are some advantages. The most important advantage is smaller influence of scattered neutrons on the reconstruction. Finally, we describe the estimation of the error of this reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bases for Spin Systems and Qudits

There is a growing interest these days for the field of quantum information and quantum computation (for which classical bits are replaced by qubits in dimension 2 and qudits in dimension d). This field is at the crossing of mathematics, informatics and quantum physics. In this work, bases of relevance for spin systems with cyclic symmetry as well as for quantum information and quantum computation are discussed from the theory of angular momentum and group-theoretical methods. This approach is connected to the use of generalized Pauli matrices (in dimension d) arising from a polar decomposition of the group SU{sub 2}. Examples are given for d = 2, 3 and 4.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fast, direct x-ray detection charge-coupled device

A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 {mu}m thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output ports. A set of companion 16-channel custom readout integrated circuits, capable of 15 bits of dynamic range, is used to read out the CCD. A gate array-controlled back end data acquisition system frames and transfers images, as well as provides the CCD clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DSP Algorithms for Fission Fragment and Prompt Fission Neutron Spectroscopy

Digital signal processing (DSP) algorithms are in high demand for modern nuclear fission investigation due to importance of increase the accuracy of fissile nuclear data for new generation of nuclear power stations. DSP algorithms for fission fragment (FF) and prompt fission neutron (PFN) spectroscopy are described in the present work. The twin Frisch-grid ionization chamber (GTIC) is used to measure the kinetic energy-, mass- and angular distributions of the FF in the {sup 252}Cf(SF) reaction. Along with the neutron time-of-flight (TOF) measurement the correlation between neutron emission and FF mass and energy is investigated. The TOF is measured between common cathode of the GTIC and the neutron detector (ND) pulses. Waveform digitizers (WFD) having 12 bit amplitude resolution and 100 MHz sampling frequency are used for the detector pulse sampling. DSP algorithms are developed as recursive procedures to perform the signal processing, similar to those available in various nuclear electronics modules, such as constant fraction discriminator (CFD), pulse shape discriminator (PSD), peak-sensitive analogue-to-digital converter (pADC) and pulse shaping amplifier (PSA). To measure the angle between FF and the cathode plane normal to the GTIC a new algorithm is developed having advantage over the traditional analogue pulse processing schemes. Algorithms are tested by comparing the numerical simulation of the data analysis of the {sup 252}Cf(SF) reaction with data available from literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of local surface potential distribution on its relaxation in polycrystalline ferroelectric films.

We have studied the effect of local surface potential distribution on its relaxation in the polycrystalline ferroelectric thin films. A lower surface potential region, i.e., potential pit, is generated near a grain boundary. The deep potential pit has a faster relaxation than the area far away from the potential pit due to the acceleration of the screen charge draining near the grain boundary and the domains formed by applying higher voltage have a faster relaxation due to the larger gradient of screen charge distribution. In addition, the surface potential and its relaxation depend on the sign of applying voltage. The result shows that the surface potential distribution may influence significantly to the reliability of bit signal on the memory devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers

An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10{sup 6} images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

42 ENGINEERING↗

A Pulsed Laser-Electromagnetic Hybrid Accelerator For Space Propulsion Application

A fundamental study of a newly developed rectangular pulsed laser-electromagnetic hybrid thruster was conducted, in which laser-ablation plasma was induced through laser beam irradiation onto a solid target and accelerated by electrical means instead of direct acceleration only by using a laser beam. The performance of the thruster was evaluated by measuring the mass per shot and impulse bit. As results, significantly high specific impulse ranging from 5,000 approx6,000 sec were obtained at energies of 0.1 and 8.6 J, respectively. In addition, the typical thrust efficiency varied from 17% to 19% depending on the charge energy.

43 PARTICLE ACCELERATORS↗

Design of microcontroller based system for automation of streak camera

A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image processing with cellular nonlinear networks implemented on field-programmable gate arrays for real-time applications in nuclear fusion

In the past years cameras have become increasingly common tools in scientific applications. They are now quite systematically used in magnetic confinement fusion, to the point that infrared imaging is starting to be used systematically for real-time machine protection in major devices. However, in order to guarantee that the control system can always react rapidly in case of critical situations, the time required for the processing of the images must be as predictable as possible. The approach described in this paper combines the new computational paradigm of cellular nonlinear networks (CNNs) with field-programmable gate arrays and has been tested in an application for the detection of hot spots on the plasma facing components in JET. The developed system is able to perform real-time hot spot recognition, by processing the image stream captured by JET wide angle infrared camera, with the guarantee that computational time is constant and deterministic. The statistical results obtained from a quite extensive set of examples show that this solution approximates very well an ad hoc serial software algorithm, with no false or missed alarms and an almost perfect overlapping of alarm intervals. The computational time can be reduced to a millisecond time scale for 8 bit 496x560-sized images. Moreover, in our implementation, the computational time, besides being deterministic, is practically independent of the number of iterations performed by the CNN - unlike software CNN implementations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Domain wall assisted magnetization switching in (111) oriented L1{sub 0} FePt grown on a soft magnetic metallic glass

We report on growth and magnetic properties of exchange-coupled (111)-L1{sub 0} FePt hard/CoFeTaB soft magnetic metallic glass bilayered structure processed at lower temperature ({approx}400 deg. C). Single phaselike hysteresis loops with tailorable coercivity (<8.2 kOe) in out of plane direction are obtained. The magnetization switching mechanism is identified as domain wall assisted. In views of excellent nanofabrication abilities of metallic glass thin film and the ability to grow preferred oriented L1{sub 0} FePt, the present bilayered structure is very promising for the fabrication of high density bit--patterned magnetic recording media and other spintronic devices.

36 MATERIALS SCIENCE↗