Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗

Application of a spring-dashpot system to clinical lung tumor motion data

Purpose: The treatment efficacy of radiation therapy for lung tumors can be increased by compensating for breath-induced tumor motion. In this study, we quantitatively examine a mathematical model of pseudomechanical linkages between an external surrogate signal and lung tumor motion. Methods: A spring-dashpot system based on the Voigt model was developed to model the correlation between abdominal respiratory motion and tumor motion during lung radiotherapy. The model was applied to clinical data obtained from 52 treatments ('beams') from 10 patients, treated on the Mitsubishi Real-Time Radiation Therapy system, Sapporo, Japan. In Stage 1, model parameters were optimized for individual patients and beams to determine reference values and to investigate how well the model can describe the data. In Stage 2, for each patient the optimal parameters determined for a single beam were applied to data from other beams to investigate whether a beam-specific set of model parameters is sufficient to model tumor motion over a course of treatment. Results: In Stage 1, the baseline root mean square (RMS) residual error for all individually optimized beam data was 0.90 {+-} 0.40 mm (mean {+-} 1 standard deviation). In Stage 2, patient-specific model parameters based on a single beam were found to model the tumor position closely, even for irregular beam data, with a mean increase with respect to Stage 1 values in RMS error of 0.37 mm. On average, the obtained model output for the tumor position was 95% of the time within an absolute bound of 2.0 and 2.6 mm in Stages 1 and 2, respectively. The model was capable of dealing with baseline, amplitude and frequency variations of the input data, as well as phase shifts between the input abdominal and output tumor signals. Conclusions: These results indicate that it may be feasible to collect patient-specific model parameters during or prior to the first treatment, and then retain these for the rest of the treatment period. The model has potential for clinical application during radiotherapy treatment of lung tumors.

60 APPLIED LIFE SCIENCES↗

Advanced ion thruster research

A simple model describing the discharge chamber performance of high strength, cusped magnetic field ion thrusters is developed. The model is formulated in terms of the energy cost of producing ions in the discharge chamber and the fraction of ions produced in the discharge chamber that are extracted to form the ion beam. The accuracy of the model is verified experimentally in a series of tests wherein the discharge voltage, propellant, grid transparency to neutral atoms, beam diameter and discharge chamber wall temperature are varied. The model is exercised to demonstrate what variations in performance might be expected by varying discharge chamber parameters. The results of a study of xenon and argon orificed hollow cathodes are reported. These results suggest that a hollow cathode model developed from research conducted on mercury cathodes can also be applied to xenon and argon. Primary electron mean free paths observed in argon and xenon cathodes that are larger than those found in mercury cathodes are identified as a cause of performance differences between mercury and inert gas cathodes. Data required as inputs to the inert gas cathode model are presented so it can be used as an aid in cathode design.

Wilbur, P. J.↗

The generation of azimuthal magnetic field in laser-induced plasma bubbles

A two-dimensional (2D) analytical model for a laser-induced bubble is rebuilt by taking into account the generation of azimuthal magnetic field. It is shown that the azimuthal magnetic field surrounds the bubble transversely, whose amplitude peaks at the bubble edge and vanishes at laser axis. In a laser wakefield acceleration scheme, the longitudinal electric field accelerates the electrons injected from the rear of the bubble, while the azimuthal magnetic field makes the resulting energetic-electron beam converge. The analytical model is justified by a 2D Particle in Cell (PIC) simulation.

43 PARTICLE ACCELERATORS↗

Analytical and experimental investigations of human spine flexure.

The authors report on experiments to measure the resistance of fresh human spines to flexion in the upper lumbar and lower thoracic regions and evaluate results by using a combination of strength of materials theory and effects of shear and comparing with data reported by other authors. The test results indicate that the thoraco-lumbar spine behaves approximately as a linear elastic beam, without relaxation effects. The authors formulate a simple continuum dynamic model of the spine simulating aircraft ejection and solve the resulting boundary value problem to illustrate the importance of the flexural mode. A constant cross-section, the selected model is a sinusoidally curved elastic beam with an end mass subjected to a Heaviside axial acceleration at the other end. The paper presents transient response results for the spinal model axial and bending displacements and axial force.-

Moffatt, C. A.↗

Interaction of the high energy deuterons with the graphite target in the plasma focus devices based on Lee model

Numerical experiments are systematically carried out using the Lee model code extended to compute the ion beams on various plasma focus devices operated with Deuterium gas. The deuteron beam properties of the plasma focus are studied for low and high energy plasma focus device. The energy spectral distribution for deuteron ions ejected from the pinch plasma is calculated and the ion numbers with energy around 1 MeV is then determined. The deuteron–graphite target interaction is studied for different conditions. The yield of the reaction {sup 12}C(d,n){sup 13}N and the induced radioactivity for one and multi shots plasma focus devices in the graphite solid target is investigated. Our results present the optimized high energy repetitive plasma focus devices as an alternative to accelerators for the production of {sup 13}N short lived radioisotopes. However, technical challenges await solutions on two fronts: (a) operation of plasma focus machines at high rep rates for a sufficient period of time (b) design of durable targets that can take the thermal load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Range and modulation dependencies for proton beam dose per monitor unit calculations

Calculations of dose per monitor unit (D/MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and electron therapy, the D/MU depends on several factors. This study focused on obtaining range and modulation dependence factors used in D/MU calculations for the double scattered proton beam line at the Midwest Proton Radiotherapy Institute. Three dependencies on range and one dependency on modulation were found. A carefully selected set of measurements was performed to discern these individual dependencies. Dependencies on range were due to: (1) the stopping power of the protons passing through the monitor chamber; (2) the reduction of proton fluence due to nuclear interactions within the patient; and (3) the variation of proton fluence passing through the monitor chamber due to different source-to-axis distances (SADs) for different beam ranges. Different SADs are produced by reconfigurations of beamline elements to provide different field sizes and ranges. The SAD effect on the D/MU varies smoothly as the beam range is varied, except at the beam range for which the first scatterers are exchanged and relocated to accommodate low and high beam ranges. A geometry factor was devised to model the SAD variation effect on the D/MU. The measured D/MU variation as a function of range can be predicted within 1% using the three modeled dependencies on range. Investigation of modulated beams showed that an analytical formula can predict the D/MU dependency as a function of modulation to within 1.5%. Special attention must be applied when measuring the D/MU dependence on modulation to avoid interplay between range and SAD effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

The dynamics and control of large flexible space structures, 2. Part A: Shape and orientation control using point actuators

The equations of planar motion for a flexible beam in orbit which includes the effects of gravity gradient torques and control torques from point actuators located along the beam was developed. Two classes of theorems are applied to the linearized form of these equations to establish necessary conditions for controlability for preselected actuator configurations. The feedback gains are selected: (1) based on the decoupling of the original coordinates and to obtain proper damping, and (2) by applying the linear regulator problem to the individual model coordinates separately. The linear control laws obtained using both techniques were evaluated by numerical integration of the nonlinear system equations. Numerical examples considering pitch and various number of modes with different combination of actuator numbers and locations are presented. The independent model control concept used earlier with a discretized model of the thin beam in orbit was reviewed for the case where the number of actuators is less than the number of modes. Results indicate that although the system is controllable it is not stable about the nominal (local vertical) orientation when the control is based on modal decoupling. An alternate control law not based on modal decoupling ensures stability of all the modes.

Bainum, P. M.↗

Exact matched-beam envelopes for undepressed transport in a quadrupole lattice with unequal drift lengths and arbitrary field strength

In 1958, Courant and Snyder analyzed the problem of alternating-gradient beam transport and treated a model without focusing gaps or space charge. Recently we revisited their work and found the exactsolution for matched-beam envelopes in a linear quadrupole lattice [O.A. Anderson and L.L. LoDestro, Phys. Rev. ST Accel. Beams, 2009]. We extend that work here to include the effect of gaps. We derive the exact envelopes and show results for various field strengths, occupancies eta,and gap-length ratios. We find the peak envelope excursion. It has a broad minimum as a function of the phase advance sigma (typically around 34o) over which it varies less than +-1percent. The phase-advance numbers also change little over the full range of gap ratios. However, the required field strengths vary appreciably. In the second stable band, the higher field strength necessitated by the lower occupancy accentuates the remarkable compression effect predicted for the FD (gapless) model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of Transverse-to-Longitudinal Emittance Exchange at the Fermilab Photoinjector

Phase space manipulation techniques with two degrees of freedom could be essential to the enhancement of the performance of next generation accelerators such as high energy colliders and accelerator-based light sources. At the Fermilab A0 Photoinjector, a proof-of-principle experiment to demonstrate the exchange of the transverse and longitudinal emittance is ongoing. The emittance exchange (EEX) beamline consists of a 3.9 GHz normal conducting deflecting mode cavity positioned between two doglegs as proposed by Kim and Sessler. The experiment is performed using electron bunches with charge of 250 pC and energy of 14.3 MeV. The incoming electron beam has transverse emittance of 2-4 mm mrad and longitudinal emittance of 10-14 mm mrad. After the EEX the measured horizonal emittance is blown up to 13-15 mm mrad while the measured vertical emittance (Non EEX plane) stays the same. At the same time the longitudinal emittance is reduced to 7-9 mm mrad as measued by the current longitudinal diagnostic tools. A linear optics model is established using the beam matrix calculated and measured. A first order simulation based on this model is performed to compare to our experiment results for both EEX measurement and the phase space manipulation experiment.

43 PARTICLE ACCELERATORS↗

SU-F-T-575: Verification of a Monte-Carlo Small Field SRS/SBRT Dose Calculation System

Purpose: To develop a methodology for validation of a Monte-Carlo dose calculation model for robotic small field SRS/SBRT deliveries. Methods: In a robotic treatment planning system, a Monte-Carlo model was iteratively optimized to match with beam data. A two-part analysis was developed to verify this model. 1) The Monte-Carlo model was validated in a simulated water phantom versus a Ray-Tracing calculation on a single beam collimator-by-collimator calculation. 2) The Monte-Carlo model was validated to be accurate in the most challenging situation, lung, by acquiring in-phantom measurements. A plan was created and delivered in a CIRS lung phantom with film insert. Separately, plans were delivered in an in-house created lung phantom with a PinPoint chamber insert within a lung simulating material. For medium to large collimator sizes, a single beam was delivered to the phantom. For small size collimators (10, 12.5, and 15mm), a robotically delivered plan was created to generate a uniform dose field of irradiation over a 2×2cm{sup 2} area. Results: Dose differences in simulated water between Ray-Tracing and Monte-Carlo were all within 1% at dmax and deeper. Maximum dose differences occurred prior to dmax but were all within 3%. Film measurements in a lung phantom show high correspondence of over 95% gamma at the 2%/2mm level for Monte-Carlo. Ion chamber measurements for collimator sizes of 12.5mm and above were within 3% of Monte-Carlo calculated values. Uniform irradiation involving the 10mm collimator resulted in a dose difference of ∼8% for both Monte-Carlo and Ray-Tracing indicating that there may be limitations with the dose calculation. Conclusion: We have developed a methodology to validate a Monte-Carlo model by verifying that it matches in water and, separately, that it corresponds well in lung simulating materials. The Monte-Carlo model and algorithm tested may have more limited accuracy for 10mm fields and smaller.

60 APPLIED LIFE SCIENCES↗

Two-dimensional finite-element analyses of simulated rotor-fragment impacts against rings and beams compared with experiments

Finite element modeling alternatives as well as the utility and limitations of the two dimensional structural response computer code CIVM-JET 4B for predicting the transient, large deflection, elastic plastic, structural responses of two dimensional beam and/or ring structures which are subjected to rigid fragment impact were investigated. The applicability of the CIVM-JET 4B analysis and code for the prediction of steel containment ring response to impact by complex deformable fragments from a trihub burst of a T58 turbine rotor was studied. Dimensional analysis considerations were used in a parametric examination of data from engine rotor burst containment experiments and data from sphere beam impact experiments. The use of the CIVM-JET 4B computer code for making parametric structural response studies on both fragment-containment structure and fragment-deflector structure was illustrated. Modifications to the analysis/computation procedure were developed to alleviate restrictions.

Stagliano, T. R.↗

Study of plasma meniscus and beam halo in negative ion sources using three dimension in real space and three dimension in velocity space particle in cell model

Our previous study by two dimension in real space and three dimension in velocity space-particle in cell model shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources. The negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. The purpose of this study is to verify this mechanism with the full 3D model. It is shown that the above mechanism is essentially unchanged even in the 3D model, while the fraction of the beam halo is significantly reduced to 6%. This value reasonably agrees with the experimental result.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Features of GaAs Nanowire SEM Images

The detailed study of GaAs nanowires synthesized by molecular beam epitaxy performed by scanning electron microscopy allowed to reveal the presence of specific contrast in the images obtained. To understand the causes of the phenomenon the transmission electron microscopy of nanowire crystal structure was carried out. The results showed that it could be caused by the segments having polytypic crystal phase. It was also confirmed by the modelling of the electron beam scattering on such nanowire arrays.

36 MATERIALS SCIENCE↗

H- Beam Loss and Evidence for Intrabeam Stripping in the LANSCE Linac

The LANSCE accelerator complex is a multi-beam, multi-user facility that provides high-intensity H{sup +} and H{sup -} particle beams for a variety of user programs. At the heart of the facility is a room temperature linac that is comprised of 100-MeV drift tube and 800-MeV coupled cavity linac (CCL) structures. Although both beams are similar in intensity and emittance at 100 MeV, the beam-loss monitors along the CCL show a trend of increased loss for H{sup -} that is not present for H{sup +}. This difference is attributed to stripping mechanisms that affect H{sup -} and not H{sup +}. We present the results of an analysis of H{sup -} beam loss along the CCL that incorporates beam spill measurements, beam dynamics simulations, analytical models and radiation transport estimates using the MCNPX code. The results indicate a significant fraction of these additional losses result from intrabeam stripping.

43 PARTICLE ACCELERATORS↗

The Ratio R{sub dp} of the quasielastic nd {yields} p(nn) to the elastic np {yields} pn charge-exchange-process yields at the proton emitting angle {theta}{sub p,lab} = 0 deg. over 0.55-2.0 GeV neutron-beam energy region. Comparison of the results with the model-dependent calculations

Our new experimental results (see, e.g., Preprint JINR no. E1-2008-61 (Dubna, 2008)) on ratio R{sub dp} of the quasielastic charge-exchange yield at the proton emitting angle {theta}{sub p,lab} = 0 deg. for the nd {yields} p(nn) reaction to the elastic np {yields} pn charge-exchange yield were presented. The measurements were carried out at the Nuclotron of the Veksler and Baldin Laboratory of High Energies of the JINR (Dubna) at the neutron-beam kinetic energies of 0.55, 0.8, 1.0, 1.2, 1.4, 1.8, and 2.0 GeV. In this paper the comparison of the experimental R{sub dp} data with the obtained R{sub dp} calculations within the impulse approximation by using the invariant-amplitude sets from the GW/VPI phase-shift analysis is made. The R{sub dp} values calculated using the set of invariant amplitude data for the elastic np {yields} pn charge exchange at {theta}{sub p,CM} = 0 deg., agree with the experimental data. This confirmed the nd {yields} p(nn) process yield at {theta}{sub p,CM} = 0 deg. is caused by the contribution of the spin-dependent part of the elastic np {yields} pn charge-exchange reaction. Thus, it has been shown that the obtained experimental R{sub dp} results can be used for the Delta-Sigma experimental program to reduce the total ambiguity in the extraction of the amplitude real parts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-A-18C-02: An Electrostatic Model for Assessment of Joint Space Morphology in Cone-Beam CT

Purpose: High-resolution cone-beam CT (CBCT) of the extremities presents a potentially valuable basis for image-based biomarkers of arthritis, trauma, and risk of injury. We present a new method for 3D joint space analysis that exploits the high isotropic spatial resolution of CBCT and is sensitive to small changes in disease-related morphology. Methods: The approach uses an “electrostatic” model in which joint surfaces (e.g., distal femur and proximal tibia) are labeled as charge densities between which the electric field is solved by approximation to the Laplace equation. The method yields a unique solution determined by the field lines across the “capacitor” and is hypothesized to be more sensitive than conventional (Sharp) scores and immune to degeneracies that limit simple distance-along-axis or closest-point analysis. The algorithm was validated in CBCT phantom images and applied in two clinical scenarios: osteoarthritis (OA, change in loadbearing tibiofemoral joint space); and assessment of injury risk (correlation of 3D joint space to tibial slope). Results: Joint space maps computed from the electrostatic model were accurate to within the voxel size (0.26 mm). The method highlighted subtle regions of morphological change that would likely be missed by conventional scalar metrics. Regions of subtle cartilage erosion were well quantified, and the method confidently discriminated OA and non-OA cohorts. 3D joint space maps correlated well with tibial slope and provide a new basis for principal component analysis of loadbearing injury risk. Runtime was less than 5 min (235×235×121 voxel subvolume in Matlab). Conclusion: A new method for joint space assessment was reported as a possible image-based biomarker of subtle articular change. The algorithm yields accurate quantitation of the joint in a manner that is robust against operator and patient setup variation. The method shows promising initial results in ongoing trials of CBCT in osteoarthritis, rheumatoid arthritis, and injury risk assessment. Research supported by R01 and R21 grants from the National Institutes of Health, academic-industry partnership with Carestream Health, and a grant from the US Army Natick Soldier Research, Development and Engineering Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization in Heavy Ion Physics

Role of polarization studies in heavy ion physics is discussed with emphasis on the search for quark-gluon plasma formation and studies of its dynamical properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗