Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Water use and radiation balance of miscanthus and corn on marginal land in the coastal plain region of North Carolina

Abstract Miscanthus is a perennial grass that can yield substantial amounts of biomass in land areas considered marginal. In the Coastal Plain region of North Carolina, marginal lands are typically located in coarse‐textured soils with low nutrient retention and water‐holding capacity, and high erosivity potential. Little is known about miscanthus water use under these conditions. We conducted a study to better understand the efficiency with which miscanthus uses natural resources such as water and radiant energy to produce harvestable dry biomass in comparison to corn, a typical commodity crop grown in the region. We hypothesized that under non‐limiting soil water conditions, miscanthus would have greater available energy and water use rates owing to its greater leaf area, thus leading to greater agronomic yields. Conversely, these effects would be negated under drought conditions. Our measurements showed that miscanthus intercepted more radiant energy than corn, which led to greater albedo (by 0.05), lower net radiation (by 4% or 0.4 MJ m −2 day −1 ), and lower soil heat flux (by 69% or 1.0 MJ m −2 day −1 ) than corn on average. Consequently, miscanthus had greater available energy (by 7% or 0.6 MJ m −2 day −1 ) and water use rates (by 14% or 0.5 mm day −1 ) than corn throughout the growing season on average, which partially confirmed our hypothesis. Greater water use rates and radiation interception by miscanthus did not translate to greater water‐use (1.5 g kg −1 vs. 1.6 g kg −1 ) and radiation‐use (0.9 g MJ −1 vs. 1.1 g MJ −1 ) efficiencies than corn. Compared to literature values, our data indicated that water and radiation availability were not limiting at our study site. Thus, it is likely that marginal land features present at the Coastal Plain region such as low soil fertility and high air temperatures throughout the growing season may constrain agronomic yields even if soil water and radiant energy are non‐limiting.

Carvalho, Henrique D. R.↗

The role of nutrients in drought‐induced tree mortality and recovery

Summary Global forests are experiencing rising temperatures and more severe droughts, with consistently dire forecasts for negative future impacts. Current research on the physiological mechanisms underlying drought impacts is focused on the water‐ and carbon‐associated mechanisms. The role of nutrients is notably missing from this research agenda. Here, we investigate what role, if any, forest nutrition plays for survival and recovery of forests during and after drought. High nutrient availability may play a detrimental role in drought survival due to preferential biomass allocation aboveground that (1) predispose plants to hydraulic constraints limiting photosynthesis and promoting hydraulic failure, (2) increases carbon costs during periods of carbon starvation, and (3) promote biotic attack due to low tissue carbon: nitrogen (C : N). When nutrient uptake occurs during drought, high nutrient availability can increase water use efficiency thus minimizing negative feedbacks between carbon and nutrient balance. Nutrients are released after drought ceases, which might promote faster recovery but the temporal dynamics of microbial immobilization and nutrient leaching have a significant impact on nutrient availability. We provide a framework for understanding nutrient impacts on drought survival that allows a more complete analysis of forest ecosystem responses. Contents Summary 513 I. Introduction 513 II. Integrating nutrients into the hydraulic framework predicting mechanisms of drought survival, mortality, and recovery 514 III. Integration 517 Acknowledgements 518 References 518

Gessler, Arthur↗

Changes in leaf economic trait relationships across a precipitation gradient are related to differential gene expression in a C 4 perennial grass

Summary The leaf economics spectrum (LES) describes a suite of functional traits that consistently covary at large spatial and taxonomic scales. Despite its importance at these larger scales, few studies have examined the major drivers of intraspecific variation in the LES – phenotypic plasticity and standing genetic variation. Using experimental precipitation manipulations, we examined whether covariation among leaf economics traits and selection on leaf economics traits and trait combinations change as diverse genotypes of the widespread perennial grass Panicum virgatum are exposed to differences in precipitation. We also used RNA‐Seq to examine whether groups of co‐expressed genes that align with leaf economics traits function in processes hypothesized to underlie the LES. Water availability impacted leaf economics trait covariation in important ways – covariation between leaf economics traits and selection on covariation between traits (i.e. correlational selection) tended to be strongest when water availability was high. Additionally, many genes associated with leaf economics traits functioned in processes that may explain how the LES originates, such as chloroplasts, cell walls, and nitrogen metabolism. Water availability is likely an important modulator of selection and evolution of the LES in P. virgatum that can be better understood by examining gene expression.

Heckman, Robert W. [Department of Integrative Biol↗

Eugenol specialty chemical production in transgenic poplar ( Populus tremula × P. alba ) field trials

Summary A foundational study assessed effects of biochemical pathway introduction into poplar to produce eugenol, chavicol, p ‐anol, isoeugenol and their sequestered storage products, from potentially available substrates, coniferyl and p ‐coumaryl alcohols. At the onset, it was unknown whether significant carbon flux to monolignols vs. other phenylpropanoid (acetate) pathway metabolites would be kinetically favoured. Various transgenic poplar lines generated eugenol and chavicol glucosides in ca . 0.45% (~0.35 and ~0.1%, respectively) of dry weight foliage tissue in field trials, as well as their corresponding aglycones in trace amounts. There were only traces of any of these metabolites in branch tissues, even after ~4‐year field trials. Levels of bioproduct accumulation in foliage plateaued, even at the lowest introduced gene expression levels, suggesting limited monolignol substrate availability. Nevertheless, this level still allows foliage collection for platform chemical production, with the remaining (stem) biomass available for wood, pulp/paper and bioenergy product purposes. Several transformed lines displayed unexpected precocious flowering after 4‐year field trial growth. This necessitated terminating (felling) these particular plants, as USDA APHIS prohibits the possibility of their interacting (cross‐pollination, etc.) with wild‐type (native plant) lines. In future, additional biotechnological approaches can be employed (e.g. gene editing) to produce sterile plant lines, to avoid such complications. While increased gene expression did not increase target bioproduct accumulation, the exciting possibility now exists of significantly increasing their amounts (e.g. 10‐ to 40‐fold plus) in foliage and stems via systematic deployment of numerous ‘omics’, systems biology, synthetic biology and metabolic flux modelling approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Validation in the Absence of Observed Events

Here our paper addresses the problem of validating models in the absence of observed events, in the area of Weapons of Mass Destruction terrorism risk assessment. We address that problem with a broadened definition of “Validation,” based on “backing up” to the reason why modelers and decision makers seek validation, and from that basis re-define validation as testing how well the model can advise decision makers in terrorism risk management decisions. We develop that into two conditions: Validation must be based on cues available in the observable world; and it must focus on what can be done to affect that observable world, i.e. risk management. That in turn leads to two foci: 1.) the risk generating process, 2.) best use of available data. Based on our experience with nine WMD terrorism risk assessment models, we then describe three best use of available data pitfalls: SME confidence bias, lack of SME cross-referencing, and problematic initiation rates. Those two foci and three pitfalls provide a basis from which we define validation in this context in terms of four tests -- Does the model: … capture initiation? … capture the sequence of events by which attack scenarios unfold? … consider unanticipated scenarios? … consider alternative causal chains? Finally, we corroborate our approach against three key validation tests from the DOD literature: Is the model a correct representation of the simuland? To what degree are the model results comparable to the real world? Over what range of inputs are the model results useful?

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Investigating the Combustion Performance of Dual Fuel Combustion with Diesel and Port Injected Hydrogen in a Large Bore Locomotive Engine

The heavy-duty transportation sector has primarily relied on conventional diesel combustion engines given their reliability and high thermal efficiency relative to spark ignition engines, but increased focus on reducing greenhouse gas emissions has led to investigation into alternative fuels. Gaseous hydrogen fuel has garnered a great deal of recent interest in the engine community given it has zero carbon, but hydrogen is not available at the scale and cost that petroleum fuels are currently available, and this is a barrier to adoption for industries that are looking to decarbonize their operations. Because of the fuel flexibility provided, dual fuel technology offers a pathway for some industries to adopt hydrogen as a fuel source while maintaining sufficient flexibility in times and locations where the new fuel is not yet available. This computational study investigates dual fuel combustion in a large bore locomotive engine architecture using direct injected diesel and port injected gaseous hydrogen fuel. With an optimal port fuel injection configuration from previous work, simulations of varying substitution ratio, compression ratio, manifold air temperature, diesel injection timing, and diesel injection pressure were performed to understand their effect on combustion performance. Results indicated that both increased substitution ratio and higher intake air temperature accelerates hydrogen flame propagation and can result in high peak cylinder pressures. Additionally, diesel injection timing and injection pressure were demonstrated as effective methods for controlling dual fuel combustion heat release rates.

ODonnell, Patrick Christopher↗

Modeling Climate-Water Impacts on Electricity Sector Capacity Expansion: Preprint

Climate change has the potential to exacerbate water availability concerns for thermal power plant cooling, which is responsible for 41% of U.S. water withdrawals. This analysis describes an initial link between climate, water, and electricity systems using the National Renewable Energy Laboratory (NREL) Regional Energy Deployment System (ReEDS) electricity system capacity expansion model. Average surface water projections from Coupled Model Intercomparison Project 3 (CMIP3) data are applied to surface water rights available to new generating capacity in ReEDS, and electric sector growth is compared with and without climate-influenced water rights. The mean climate projection has only a small impact on national or regional capacity growth and water use because most regions have sufficient unappropriated or previously retired water rights to offset climate impacts. Climate impacts are notable in southwestern states that purchase fewer water rights and obtain a greater share from wastewater and other higher-cost water resources. The electric sector climate impacts demonstrated herein establish a methodology to be later exercised with more extreme climate scenarios and a more rigorous representation of legal and physical water availability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transparent ceramic scintillators for gamma-ray spectroscopy and radiography

Transparent ceramics have become available in useful sizes for a variety of applications within the past 15 years thanks to improved understanding of sintering phenomena on the nanoscale.1,2 While traditional ceramics may comprise single or multiple crystalline and amorphous mineral phases and are typically translucent or opaque to light, modern optically transparent ceramics are fully dense monoliths of micron-scale (or smaller) crystallites, in most cases formed from pure-phase cubic crystal structures. Fabrication of transparent ceramics begins with high-purity ceramic nanopowders, which are consolidated into a ‘green body’ by pressing or casting. The green body is sintered to near-full density, and the residual porosity is removed by processing the samples in a pressure vessel with high-pressure argon gas (hot isostatic pressing). A few commercial transparent ceramics are Lumicera lenses (a barium-based oxide made by Murata Mfg.), laser gain media—Nd:YAG (neodymium-doped yttrium aluminum garnet) is available from Konoshima—and transparent armor (aluminum oxynitride and spinel are available from Surmet and other vendors). As the manufacturing processes for transparent ceramics become better understood, industrial optical uses for these transparent materials with excellent mechanical robustness are likely to expand.

36 MATERIALS SCIENCE↗

Vision 20/20: Proton therapy

The first patients were treated with proton beams in 1955 at the Lawrence Berkeley Laboratory in California. In 1970, proton beams began to be used in research facilities to treat cancer patients using fractionated treatment regimens. It was not until 1990 that proton treatments were carried out in hospital-based facilities using technology and techniques that were comparable to those for modern photon therapy. Clinical data strongly support the conclusion that proton therapy is superior to conventional radiation therapy in a number of disease sites. Treatment planning studies have shown that proton dose distributions are superior to those for photons in a wide range of disease sites indicating that additional clinical gains can be achieved if these treatment plans can be reliably delivered to patients. Optimum proton dose distributions can be achieved with intensity modulated protons (IMPT), but very few patients have received this advanced form of treatment. It is anticipated widespread implementation of IMPT would provide additional improvements in clinical outcomes. Advances in the last decade have led to an increased interest in proton therapy. Currently, proton therapy is undergoing transitions that will move it into the mainstream of cancer treatment. For example, proton therapy is now reimbursed, there has been rapid development in proton therapy technology, and many new options are available for equipment, facility configuration, and financing. During the next decade, new developments will increase the efficiency and accuracy of proton therapy and enhance our ability to verify treatment planning calculations and perform quality assurance for proton therapy delivery. With the implementation of new multi-institution clinical studies and the routine availability of IMPT, it may be possible, within the next decade, to quantify the clinical gains obtained from optimized proton therapy. During this same period several new proton therapy facilities will be built and the cost of proton therapy is expected to decrease, making proton therapy routinely available to a larger population of cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recommendations for clinical electron beam dosimetry: Supplement to the recommendations of Task Group 25

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance testing and treatment planning of new accelerators with therapeutic electron beams. Since the publication of the TG-25 report, significant advances have taken place in the field of electron beam dosimetry, the most significant being that primary standards laboratories around the world have shifted from calibration standards based on exposure or air kerma to standards based on absorbed dose to water. The AAPM has published a new calibration protocol, TG-51, for the calibration of high-energy photon and electron beams. The formalism and dosimetry procedures recommended in this protocol are based on the absorbed dose to water calibration coefficient of an ionization chamber at {sup 60}Co energy, N{sub D,w}{sup 60{sub C}{sub o}}, together with the theoretical beam quality conversion coefficient k{sub Q} for the determination of absorbed dose to water in high-energy photon and electron beams. Task Group 70 was charged to reassess and update the recommendations in TG-25 to bring them into alignment with report TG-51 and to recommend new methodologies and procedures that would allow the practicing medical physicist to initiate and continue a high quality program in clinical electron beam dosimetry. This TG-70 report is a supplement to the TG-25 report and enhances the TG-25 report by including new topics and topics that were not covered in depth in the TG-25 report. These topics include procedures for obtaining data to commission a treatment planning computer, determining dose in irregularly shaped electron fields, and commissioning of sophisticated special procedures using high-energy electron beams. The use of radiochromic film for electrons is addressed, and radiographic film that is no longer available has been replaced by film that is available. Realistic stopping-power data are incorporated when appropriate along with enhanced tables of electron fluence data. A larger list of clinical applications of electron beams is included in the full TG-70 report available at http://www.aapm.org/pubs/reports. Descriptions of the techniques in the clinical sections are not exhaustive but do describe key elements of the procedures and how to initiate these programs in the clinic. There have been no major changes since the TG-25 report relating to flatness and symmetry, surface dose, use of thermoluminescent dosimeters or diodes, virtual source position designation, air gap corrections, oblique incidence, or corrections for inhomogeneities. Thus these topics are not addressed in the TG-70 report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom

Purpose: To calibrate a Gamma Knife (GK) Perfexion using TG-21 with updated chamber-dependent values for modern microionization chambers in the new solid water Leksell dosimetry phantom. This work illustrates a calibration method using commercially available equipment, instruments, and an established dosimetry protocol that may be adopted at any GK center, thus reducing the interinstitutional variation in GK calibration. The calibration was verified by three third-party dosimetry checks. In addition, measurements of the relative output factors are presented and compared to available data and the new manufacturer-provided relative output factors yet to be released. Methods: An absolute dose calibration based on the TG-21 formalism, utilizing recently reported phantom material and chamber-dependent factors, was performed using a microionization chamber in a spherical solid water phantom. The result was compared to other calibration protocols based on TG-51. Independent verification of the machine output was conducted through M.D. Anderson Dosimetry Services (MDADS), using thermoluminescent dosimeters (TLDs) in an anthropomorphic head phantom; the Radiological Physics Center (RPC), using TLDs in the standard Elekta ABS plastic calibration phantom (gray phantom), included with the GK; and through a collaborative international calibration survey by the University of Pittsburgh Medical Center (UPMC) using alanine dosimeters, also in the gray phantom. The alanine dosimeters were read by the National Institute of Standards and Technology. Finally, Gafchromic EBT film was used to measure relative output factors and these factors were compared to values reported in the literature as well as new values announced for release by Elekta. The films were exposed in the solid water phantom using an included film insert accessory. Results: Compared to the TG-21 protocol in the solid water phantom, the modified and unmodified TG-51 calibrations resulted in dose rates which were 1.8% and 1.3% lower, respectively. Ratios of the doses measured by third parties to the dose reported showed excellent agreement. MDADS returned ratios of 1.00 and 0.98 for the two TLDs irradiated. The RPC returned a mean ratio of 0.98 of the dose reported and the UPMC alanine study returned a mean ratio of 1.008. Relative output factors were found to be 0.817{+-}0.009 and 0.897{+-}0.008 for the 4 and 8 mm collimators, respectively, which are in excellent agreement with revised Monte Carlo-derived relative output factors Elekta is expected to recommend with the next version of the GK treatment planning software (GAMMAPLAN version 10). Conclusions: The TG-21 dosimetry protocol, performed in a solid water phantom in conjunction with modern dosimeters and phantom material and chamber-dependent factors, can yield an accurate dose measurement in the unique GK treatment geometry. The technique described here can be easily adopted by institutions worldwide since all equipment and instruments used are commercially available, thus reducing the existing interinstitutional variation in GK calibration techniques. Relative output factor measurements made in this same solid water phantom were used to verify the relative output factors provided by Elekta and agreed excellently with output factors expected to be released in conjunction with GAMMAPLAN version 10.

60 APPLIED LIFE SCIENCES↗

An approach to assessing stochastic radiogenic risk in medical imaging

Purpose: This letter suggests a formalism, the medical effective dose (MED), that is suitable for assessing stochastic radiogenic risks in diagnostic medical procedures. Methods: The MED is derived from radiobiological and probabilistic first principals, including: (1) The independence of radiation-induced biological effects in neighboring voxels at low doses; (2) the linear no-threshold assumption for stochastic radiation injury (although other dose-response relationships could be incorporated, instead); (3) the best human radiation dose-response data currently available; and (4) the built-in possibility that the carcinogenic risk to an irradiated organ may depend on its volume. The MED involves a dose-risk summation over irradiated voxels at high spatial resolution; it reduces to the traditional effective dose when every organ is irradiated uniformly and when the dependence of risk on organ volumes is ignored. Standard relative-risk tissue weighting factors can be used with the MED approach until more refined data become available. Results: The MED is intended for clinical and phantom dosimetry, and it provides an estimate of overall relative radiogenic stochastic risk for any given dose distribution. A result of the MED derivation is that the stochastic risk may increase with the volume of tissue (i.e., the number of cells) irradiated, a feature that can be activated when forthcoming radiobiological research warrants it. In this regard, the MED resembles neither the standard effective dose (E) nor the CT dose index (CTDI), but it is somewhat like the CT dose-length product (DLP). Conclusions: The MED is a novel, probabilistically and biologically based means of estimating stochastic-risk-weighted doses associated with medical imaging. Built in, ab initio, is the ability to link radiogenic risk to organ volume and other clinical factors. It is straightforward to implement when medical dose distributions are available, provided that one is content, for the time being, to accept the relative tissue weighting factors published by the International Commission of Radiological Protection (ICRP). It requires no new radiobiological data and avoids major problems encountered by the E, CTDI, and CT-E formalisms. It makes possible relative inter-patient dosimetry, and also realistic intercomparisons of stochastic risks from different protocols that yield images of comparable quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

On proton CT reconstruction using MVCT-converted virtual proton projections

Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of {+-}0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of {+-}0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of {+-}1.1% compared with that reconstructed from theoretical projections. If these images are used for treatment planning, the average proton range uncertainty is estimated to be less than 1.5% for an imaging dose in the milligray range. Conclusions: The proposed method can be used to convert x-ray projections into virtual proton projections. The converted proton projections can be blended with existing proton projections or can be used solely for pCT reconstruction, addressing the range limit problem of pCT using current therapeutic proton machines.

60 APPLIED LIFE SCIENCES↗

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗