Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analyzed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Analyzing Residential Charging Demand for Light-Duty Electric Vehicles in Colorado: Preprint

The past decade has witnessed the rapid adoption of electric vehicles (EVs). The momentum is expected to continue with strong support from the government and industry. Rapid EV adoption brings significant charging demand to the power grid, causing additional stress and non-negligible risks to the already-aging power grid. To help power grid operators understand the impacts of EV home charging on the grid and identify risk factors, this study presents a data-driven residential charging demand analysis for light-duty vehicles. This study considers two real-world grid service regions in Colorado and merges multiple data sources and state-of-the-art tools that characterize EV adoption projections, vehicle travel patterns, seasonal variations, residential charging accessibility, ambient temperature impact, EV charging behaviors, grid utility customers, vehicle registration, and household-level EV charging demand distribution. We characterize potential residential charging demand in 2030 for two regions within the state of Colorado: Boulder and Aurora. We project that EVs will be 26% of the light-duty vehicle population in Boulder and 16% in Aurora. Charging demand is characterized for ten power grid feeders (five for each study region). Across the ten feeders, peak total EV charging powers during wintertime range from less than 1 MW to more than 4 MW.

ADVANCED PROPULSION SYSTEMS↗

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗

Generating and Analyzing Program Call Graphs using Ontology

Call graph or caller-callee relationships have been used for various kinds of static program analysis, performance analysis and profiling, and for program safety or security analysis such as detecting anomalies of program execution or code injection attacks. However, different tools generate call graphs in different formats, which prevents efficient reuse of call graph results. In this paper, we present an approach of using ontology and resource description framework (RDF) to create knowledge graphs for specifying call graphs to facilitate the construction of full-fledged and complex call graphs of computer programs, realizing more interoperable and scalable program analyses than conventional approaches. We create a formal ontology-based specification of call graph information to capture concepts and properties of both static and dynamic call graphs so different tools can collaboratively contribute to more comprehensive analysis results. Our experiments show that ontology enables merging of call graphs generated from different tools and flexible queries using a standard query interface. Index Terms—Callgraph, ontology, knowl

Dorta, E.↗

Analyzing the Effects of the Interference between One- and Two-Body Currents on Neutrino-Nucleus Scattering in ACHILLES

Modeling improvements of neutrino–nucleus scattering are an essential aspect of reducing systematic uncertainties for current and future neutrino oscillation experiments. In particular, retaining quantum mechanical effects such as the interference between one-body (1p1h) and two-body (2p2h) currents in our cross-section models is an essential consideration. This work investigates the impact of this interference term on neutrino–argon scattering using the ACHILLES event generator, which directly implements the interference model developed by Lovato, Rocco, and Steinberg. Using fluxes relevant to SBND, the DUNE near detector, and MiniBooNE, charged- and neutral-current event samples are generated and predicted event rates are plotted against a variety of kinematic variables. For events simulated using the SBND flux, it is found that interference contributes approximately 10 \% to the total charged-current event rate, and serves to enhance the quasi-elastic peak. When considering events generated using the DUNE flux, resonance interactions contribute more to the predicted event rate, as the neutrino flux extends out to higher energies. The relative interference contribution subsequently decreases to roughly 7 \%. Neutral-current simulations show a higher rate of neutron knockout. Finally, a comparison of argon-to-carbon cross-section ratios is performed utilizing fluxes from SBND and MiniBooNE.

Pando, Nathan [Fermilab]↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Investigation of Magmatic Activities on Early Mars Using Igneous Mineral Chemistry in Gale Crater, Mars

One objective of rover missions is exploring the geological context of the surroundings. Over the years, igneous petrology and sedimentology have been disconnected, the first investigating magmatic processes and volcanic activities, and the second seeking environmental conditions in the past and assessing the habitability of the planet. Although different, one is related to the other: igneous rocks are altered and broken down, leading to the formation of sedimentary rocks, which can in turn be used to back out the nature of their magmatic source. The Curiosity rover that landed in the 3.7 Gyr old impact crater Gale is traveling through sedimentary rocks. About fifty float rocks have been observed, and several of them with ambiguous texture and composition have been classified as igneous or sedimentary depending on studies such as Jake_M. The composition of several unambiguous igneous rocks has been analyzed [4- 6] but their heterogeneity at a larger instrumental (measurement size < 2 cm) scale prevents the measurement of a bulk composition as performed on Earth. An original approach avoiding these two last issues is to consider igneous mineral chemistry analyzed within igneous and sedimentary rocks to assess magmatic processes that could have formed them. Most Curiosity data are used to explore ancient environmental conditions, and a significant number of compositional analyses are under-explored for constraining magmatic activities. We will present how we can make use of sedimentary data for investigating igneous processes in the vicinity of Gale crater. Geological Context: We focus on the first 750 martian days, corresponding to measurements in a coherent lacustrine sedimentary unit called Bradbury, because all sedimentary rocks were sourced from the same watershed and appear to have a consistent source with minimal alteration [2-3]. Igneous detrital minerals including feldspar and pyroxene, are observed in sedimentary rocks. Monte Carlo models showed that minimal cation loss is observed based on the composition of all Bradbury rocks, implying negligible weathering [3]. Although clay minerals are detected in few rocks [7], chemical compositions of rocks can be explained by a mixture of primary igneous minerals [3]. Variation of composition within Bradbury rocks can be explained by mineral sorting and one distinct source component. While a common magmatic source is suggested, Bradbury sediments likely come from several volcanic eruptions from a single magmatic chamber [9- 10]. The occurrence of alkali minerals like sanidine and K-rich rocks throughout Bradbury supports the presence of a potassic component, likely trachytic, while plagioclase and a mafic composition suggest a basaltic component [8-9]. Instruments: Mineral chemistry can be estimated by three instruments onboard Curiosity. The CheMin instrument enables detection of mineral assemblages using X-ray diffraction (XRD). Using Rietveld refinement, each mineral is identified according to their 1D XRD pattern [11]. Note that distinction between pyroxene minerals is challenging with the CheMin instrument due to overlapping peaks on XRD patterns and low angular resolution of the instrument [12]. Then, using least square regression and optimization algorithms based on unit-cell parameters, mineral chemistry has been estimated by [11]. Plagioclase composition has been estimated using the NaAlSi3O8- CaAl2Si2O8 system and alkali feldspar is based on the NaAlSi3O8-KAlSi3O8 system (stars in Fig.1). Two mudstone samples (John Klein and Cumberland) and one sandstone sample (Windjana) were analyzed by CheMin at Yellowknife Bay and Kimberley, respectively. Figure 1. Ternary diagrams of feldspars (top) and pyroxene (bottom) quadrilateral. Stars correspond to CheMin composition and the gray patches to ChemCam composition. The colored dots are the composition of feldspar and pyroxene that crystallized during fractional crystallization at FMQ+1 of a melt extracted at distinct melting degree during the adiabatic ascent of a primitive mantle composition, without any water (left panels) and with 0.5 wt.% of water (right panels) at distinct pressure. The ChemCam instrument enables the analysis of the chemical compositions of rocks at hundreds of micrometer scale (350-550 μm) using laser induced breakdown spectroscopy (LIBS), which may provide the composition of minerals when they are larger than the beam spot (>550 μm) [13]. Within >5000 LIBS points, we performed a typical stoichiometric filtering allowing us to distinguish 56 feldspar and 10 pyroxene mineral compositions (grey patches in Fig. 1). Finally, the Alpha Particle X-ray Spectrometer (APXS) analyzes the composition of rocks with a 1.6 cm diameter spot size. Monte Carlo mass balance modeling allowed [3] to decipher a feldspar range varying between An30 and An40 (Fig. 1). Discussion: Although there could be a more complex history and other ways to form the whole compositional range of igneous minerals analyzed within the Bradbury formation, we are presenting here simple magmatic pathways commonly occurring on Earth using the thermodynamical softwares pMELTS and rhyoliteMELTS [14]. The objective is to find reasonable igneous processes that produce minerals that parallel the compositions of feldspar and pyroxene analyzed by the Curiosity rover. As commonly observed for mid-ocean ridge basalts, the adiabatic ascent of a primitive mantle composition [15] partially melting at 2 GPa has been modeled, followed by the extraction of a liquid at distinct degrees of partial melting, which undergoes fractional crystallization at an oxygen fugacity +1 log unit above the fayalite-magnetite-quartz (FMQ) buffer within the crust (0.02-0.4 GPa) with H2O = 0- 0.5 wt. %. These latter conditions correspond to those recorded within igneous clasts from the Noachian martian breccia NWA 7034 and paired and within Gale igneous rocks (colored dots in Fig. 1) [16-17]. To check the reliability of these 2-step models, we also tested fractional crystallization at similar conditions (FMQ+1; P=0.02-0.4 GPa; H2O = 0-0.5 wt. %) of starting compositions corresponding to that of magmas with distinct melting degrees obtained from isobaric experiments at 2 GPa [18]. Mineral compositions obtained from both models are similar. As shown on Fig. 1, the whole range of observed feldspar compositions cannot be reproduced by fractionation of one magma only. Indeed, while alkali feldspar and Na-plagioclase likely crystallized from fractional crystallization of a low-degree melt (here <15%), plagioclase and pyroxene can only be formed by fractional crystallization of a higher degree melt (here >19%). The corresponding liquid descent lines are broadly in agreement with compositions estimated by ChemCam corresponding to float igneous rocks (Fig. 2) [4-6]. Figure 2. Silica versus alkali content. Lines show the liquid lines of descent from magmas with distinct degrees of melting. Gray patches represents the composition of Gale igneous rocks [4-6]. Trachytic to rhyolitic magmas crystallize alkali feldspar, and andesite to dacite magmas likely form plagioclase. Therefore, at least two starting magmas at distinct melting degrees, which could easily come from a single mantle source, are necessary to explain the whole compositional range of feldspar and pyroxene analyzed within Bradbury rocks. Conclusion: Because rocks from the Bradbury formation are likely originating from the same magmatic source with minimal weathering as supported by several studies using different approaches, igneous mineral chemistry analyzed by CheMin and ChemCam allows us to back out reasonable magmatic pathways that could have crystallized them. Fractional crystallization of at least two starting magmas originating from distinct melting degrees of a single mantle source can explain the whole range of feldspar and pyroxene composition. Both alkaline and sub-alkaline liquids can be produced, with compositions corresponding to those of the igneous rocks analyzed by ChemCam within the Bradbury formation, highlighting the complexity of Mars magmatism.

Payre, V.↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗