Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Computation of imaginary-side pressure distributions over the flexible walls of the test section insert for the 0.3-M transonic cryogenic tunnel

Two dimensional airfoil testing in an adaptive wall test-section wind tunnel requires the computation of the imaginary flow fields extending outward from the top and bottom test section walls. A computer program was developed to compute the flow field which would be associated with an arbitrary test section wall shape. The program is based on incompressible flow theory with a Prandtl-Glauert compressibility correction. The program was validated by comparing the streamline and the pressure field generated by a source in uniform flow with the results from the computer program. A listing of the program, the validation test results, and a sample program are included.

Goodyer, M. J.↗

Sarnoff JND Vision Model for Flat-Panel Design

This document describes adaptation of the basic Sarnoff JND Vision Model created in response to the NASA/ARPA need for a general-purpose model to predict the perceived image quality attained by flat-panel displays. The JND model predicts the perceptual ratings that humans will assign to a degraded color-image sequence relative to its nondegraded counterpart. Substantial flexibility is incorporated into this version of the model so it may be used to model displays at the sub-pixel and sub-frame level. To model a display (e.g., an LCD), the input-image data can be sampled at many times the pixel resolution and at many times the digital frame rate. The first stage of the model downsamples each sequence in time and in space to physiologically reasonable rates, but with minimum interpolative artifacts and aliasing. Luma and chroma parts of the model generate (through multi-resolution pyramid representation) a map of differences-between test and reference called the JND map, from which a summary rating predictor is derived. The latest model extensions have done well in calibration against psychophysical data and against image-rating data given a CRT-based front-end. THe software was delivered to NASA Ames and is being integrated with LCD display models at that facility,

Brill, Michael H.↗

Performance Risk Model (PRisM) Proof-of-Concept: An Operational Decision Support Tool to Predict Crew Performance in Space from Available Performance Tests

The Crew Health and Performance-Probabilistic Risk Assessment (CHP-PRA) team at NASA Glenn Research Center has developed a range of tools to evaluate astronaut health during spaceflight and to optimize the medical set required for missions. Among these, the Performance Risk Model (PRisM) represents a novel advancement, extending CHP-PRA’s focus beyond medical systems into the domain of human performance. Such tool could be pivotal in optimizing astronaut capabilities during space travel, thereby enhancing overall mission success. PRisM leverages data from well-established performance assessments conducted during previous crewed space missions and Earth analogs to strategically predict outcomes for planned tasks, even when direct performance testing has not been conducted for those specific tasks. To evaluate performance, PRisM references the various metrics outlined in NASA-STD-3001 and employs a methodology to integrate different performance scales. This framework analyzes the contribution of various human system task categories (HSTCs) to task execution and compares these contributions to the HSTCs’ involvement in other known tests. The model further employs a Monte Carlo simulation to sample performance scores from their distribution in operationally relevant tests such as those in Mulavara et al. (2018) and, by leveraging similarities in HSTC involvement, transfers this knowledge to actual mission tasks, such as those outlined in the "Human Exploration of Mars: Preliminary List of Crew Tasks”. The current PRisM proof-of-concept includes analyses of the impact of exercise and specific medications on astronauts’ performance, with provisions to incorporate additional countermeasures as data becomes available. Furthermore, the tool is customizable to include any system necessary to fully encompass the domain of human systems and can be adapted to evaluate performance for any spaceflight activities as requested by operational stakeholders. PRisM has the potential to assist the Human Research Program in exploring the capabilities trade space for optimized crew performance.

performance modeling↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

Extreme ultraviolet resonant inelastic X-ray scattering (RIXS) at a seeded free-electron laser

In the past few years, we have been witnessing an increased interest for studying materials properties under non-equilibrium conditions. Several well established spectroscopies for experiments in the energy domain have been successfully adapted to the time domain with sub-picosecond time resolution. Here we show the realization of high resolution resonant inelastic X-ray scattering (RIXS) with a stable ultrashort X-ray source such as an externally seeded free electron laser (FEL). We have designed and constructed a RIXS experimental endstation that allowed us to successfully measure the d-d excitations in KCoF 3 single crystals at the cobalt M 2,3-edge at FERMI FEL (Elettra-Sincrotrone Trieste, Italy). The FEL-RIXS spectra show an excellent agreement with the ones obtained from the same samples at the MERIXS endstation of the MERLIN beamline at the Advanced Light Source storage ring (Berkeley, USA). We established experimental protocols for performing time resolved RIXS experiments at a FEL source to avoid X ray-induced sample damage, while retaining comparable acquisition time to the synchrotron based measurements. Finally, we measured and modelled the influence of the FEL mixed electromagnetic modes, also present in externally seeded FELs, and the beam transport with ~120 meV experimental resolution achieved in the presented RIXS setup.

36 MATERIALS SCIENCE↗

Single shot near edge x-ray absorption fine structure spectroscopy in the laboratory

With the help of adapted off-axis reflection zone plates, near edge X-ray absorption fine structure spectra at the C and N K-absorption edge have been recorded using a single 1.2 ns long soft X-ray pulse. The transmission experiments were performed with a laser-produced plasma source in the laboratory rendering time resolved measurements feasible independent on large scale facilities. A resolving power of E/ΔE ∼ 950 at the respective edges could be demonstrated. A comparison of single shot spectra with those collected with longer measuring time proves that all features of the used reference samples (silicon nitrate and polyimide) can be resolved in 1.2 ns. Hence, investigations of radiation sensitive biological specimen become possible due to the high efficiency of the optical elements enabling low dose experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The MASSIVE survey. I. A volume-limited integral-field spectroscopic study of the most massive early-type galaxies within 108 Mpc

Massive early-type galaxies represent the modern day remnants of the earliest major star formation episodes in the history of the universe. These galaxies are central to our understanding of the evolution of cosmic structure, stellar populations, and supermassive black holes, but the details of their complex formation histories remain uncertain. To address this situation, we have initiated the MASSIVE Survey, a volume-limited, multi-wavelength, integral-field spectroscopic (IFS) and photometric survey of the structure and dynamics of the ∼100 most massive early-type galaxies within a distance of 108 Mpc. This survey probes a stellar mass range M* ≳ 10{sup 11.5} M {sub ☉} and diverse galaxy environments that have not been systematically studied to date. Our wide-field IFS data cover about two effective radii of individual galaxies, and for a subset of them, we are acquiring additional IFS observations on sub-arcsecond scales with adaptive optics. We are also acquiring deep K-band imaging to trace the extended halos of the galaxies and measure accurate total magnitudes. Dynamical orbit modeling of the combined data will allow us to simultaneously determine the stellar, black hole, and dark matter halo masses. The primary goals of the project are to constrain the black hole scaling relations at high masses, investigate systematically the stellar initial mass function and dark matter distribution in massive galaxies, and probe the late-time assembly of ellipticals through stellar population and kinematical gradients. In this paper, we describe the MASSIVE sample selection, discuss the distinct demographics and structural and environmental properties of the selected galaxies, and provide an overview of our basic observational program, science goals and early survey results.

79 ASTRONOMY AND ASTROPHYSICS↗

Light-responsive expression atlas reveals the effects of light quality and intensity in Kalanchoë fedtschenkoi, a plant with crassulacean acid metabolism

Abstract Background Crassulacean acid metabolism (CAM), a specialized mode of photosynthesis, enables plant adaptation to water-limited environments and improves photosynthetic efficiency via an inorganic carbon-concentrating mechanism. Kalanchoë fedtschenkoi is an obligate CAM model featuring a relatively small genome and easy stable transformation. However, the molecular responses to light quality and intensity in CAM plants remain understudied. Results Here we present a genome-wide expression atlas of K. fedtschenkoi plants grown under 12 h/12 h photoperiod with different light quality (blue, red, far-red, white light) and intensity (0, 150, 440, and 1,000 μmol m–2 s–1) based on RNA sequencing performed for mature leaf samples collected at dawn (2 h before the light period) and dusk (2 h before the dark period). An eFP web browser was created for easy access of the gene expression data. Based on the expression atlas, we constructed a light-responsive co-expression network to reveal the potential regulatory relationships in K. fedtschenkoi. Measurements of leaf titratable acidity, soluble sugar, and starch turnover provided metabolic indicators of the magnitude of CAM under the different light treatments and were used to provide biological context for the expression dataset. Furthermore, CAM-related subnetworks were highlighted to showcase genes relevant to CAM pathway, circadian clock, and stomatal movement. In comparison with white light, monochrome blue/red/far-red light treatments repressed the expression of several CAM-related genes at dusk, along with a major reduction in acid accumulation. Increasing light intensity from an intermediate level (440 μmol m-2 s-1) of white light to a high light treatment (1,000 μmol m–2 s–1) increased expression of several genes involved in dark CO2 fixation and malate transport at dawn, along with an increase in organic acid accumulation. Conclusions This study provides a useful genomics resource for investigating the molecular mechanism underlying the light regulation of physiology and metabolism in CAM plants. Our results support the hypothesis that both light intensity and light quality can modulate the CAM pathway through regulation of CAM-related genes in K. fedtschenkoi.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical-learning strategies generate only modestly performing predictive models for urinary symptoms following external beam radiotherapy of the prostate: A comparison of conventional and machine-learning methods

Purpose: Given the paucity of available data concerning radiotherapy-induced urinary toxicity, it is important to ensure derivation of the most robust models with superior predictive performance. This work explores multiple statistical-learning strategies for prediction of urinary symptoms following external beam radiotherapy of the prostate. Methods: The performance of logistic regression, elastic-net, support-vector machine, random forest, neural network, and multivariate adaptive regression splines (MARS) to predict urinary symptoms was analyzed using data from 754 participants accrued by TROG03.04-RADAR. Predictive features included dose-surface data, comorbidities, and medication-intake. Four symptoms were analyzed: dysuria, haematuria, incontinence, and frequency, each with three definitions (grade ≥ 1, grade ≥ 2 and longitudinal) with event rate between 2.3% and 76.1%. Repeated cross-validations producing matched models were implemented. A synthetic minority oversampling technique was utilized in endpoints with rare events. Parameter optimization was performed on the training data. Area under the receiver operating characteristic curve (AUROC) was used to compare performance using sample size to detect differences of ≥0.05 at the 95% confidence level. Results: Logistic regression, elastic-net, random forest, MARS, and support-vector machine were the highest-performing statistical-learning strategies in 3, 3, 3, 2, and 1 endpoints, respectively. Logistic regression, MARS, elastic-net, random forest, neural network, and support-vector machine were the best, or were not significantly worse than the best, in 7, 7, 5, 5, 3, and 1 endpoints. The best-performing statistical model was for dysuria grade ≥ 1 with AUROC ± standard deviation of 0.649 ± 0.074 using MARS. For longitudinal frequency and dysuria grade ≥ 1, all strategies produced AUROC>0.6 while all haematuria endpoints and longitudinal incontinence models produced AUROC<0.6. Conclusions: Logistic regression and MARS were most likely to be the best-performing strategy for the prediction of urinary symptoms with elastic-net and random forest producing competitive results. The predictive power of the models was modest and endpoint-dependent. New features, including spatial dose maps, may be necessary to achieve better models.

60 APPLIED LIFE SCIENCES↗

Modal focal adaptive optics for Bessel-focus two-photon fluorescence microscopy

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM. Measuring and correcting aberration using a spatial light modulator placed in conjugation with the focal plane of the microscope objective, MFAO employs Zernike annular polynomials — a first in AO implementation — to achieve performance on par with a previous zonal AO method, but with a notably simplified optical configuration. We validated the performance of MFAO in correcting artificial and sample-induced aberrations, as well as in in vivo imaging of zebrafish larvae and mouse brains. By expanding the application of modal AO to annular pupils as well as aberration measurement and correction to a wavefront modulator at the objective focal plane, MFAO represents a notable advancement in the implementation of AO in microscopy.

47 OTHER INSTRUMENTATION↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Multiscale Shear Properties and Flow Performance of Milled Woody Biomass

One dominant challenge facing the development of biorefineries is achieving consistent system throughput with highly variant biomass feedstock quality and handling performance. Current handling unit operations are adapted from other sectors (primarily agriculture), where some simplifying assumptions about granular mechanics and flow performance do not translate well to a highly compressible and anisotropic material with nonlinear time- and stress-dependent properties. This work explores the shear and frictional properties of loblolly pine at multiple experimental test apparatus and particle scales to elucidate a property window that defines the shear behavior over a range of material attributes (particle size, size distribution, moisture content, etc.). In general, it was observed that the bulk internal friction and apparent cohesion depend strongly on both the stress state of the sample in granular shear testers and the overall particle size and distribution span. For equipment designed to characterize the quasi-static shear stress failure of bulk materials ranging from 50 to 1,000 ml in test volume, similar test results were observed for finely milled particles (50% passing size of 1.4 mm) with a narrow size distribution (span between 10 and 90% passing size of 0.9 mm), while stress chaining and over-torque issues persisted for the bench-scale test apparatus for larger particle sizes or widely dispersed sample sizes. Measurement of the anisotropic particle–particle friction ranged from coefficients of approximately 0.20 to 0.45 and resulted in significantly higher and more variable friction measurements for larger particle sizes and in perpendicular alignment orientations. To supplement these laboratory-scale properties, this work explores the flow of loblolly pine and Douglas fir through a pilot-scale wedge-shaped hopper and a screw feeder. For the gravity-driven hopper flow, the critical arching distance and mass discharge rate ranged from approximately 10 to 30 mm and 2 to 16 tons/hour, respectively, for both materials, where the arching distance depends strongly on the overall particle size and depends less on the hopper inclination angle. Comparatively, the auger feeder was found to be much more impacted by the size of the particles, where smaller particles had a more consistent and stable flow while consuming less power.

09 BIOMASS FUELS↗

Characterization of radiation-induced damage in high performance polymers by electron paramagnetic resonance imaging spectroscopy

The potential for long-term human activity beyond the Earth's protective magnetosphere is limited in part by the lack of detailed information on the effectiveness and performance of existing structural materials to shield the crew and spacecraft from highly penetrating space radiations. The two radiations of greatest concern are high energy protons emitted during solar flares and galactic cosmic rays which are energetic ions ranging from protons to highly oxidized iron. Although the interactions of such high-energy radiations with matter are not completely understood at this time, the effects of the incident radiation are clearly expected to include the formation of paramagnetic spin centers via ionization and bond-scission reactions in the molecular matrices of structural materials. Since this type of radiation damage is readily characterized by Electron Paramagnetic Resonance (EPR) spectroscopy, the NASA Langley Research Center EPR system was repaired and brought on-line during the 1991 ASEE term. A major goal of the 1992 ASEE term was to adapt the existing core of the LaRC EPR system to meet the requirements for EPR Imaging--a powerful new technique which provides detailed information on the internal structure of materials by mapping the spatial distribution of unpaired spin density in bulk media. Major impetus for this adaptation arises from the fact that information derived from EPRI complements other methods such as scanning electron microscopy which primarily characterize surface phenomena. The modification of the EPR system has been initiated by the construction of specially designed, counterwound Helmholtz coils which will be mounted on the main EPR electromagnet. The specifications of the coils have been set to achieve a static linear magnetic field gradient of 10 gauss/mm/amp along the principal (Z) axis of the Zeeman field. Construction is also in progress of a paramagnetic standard in which the spin distribution is known in all three dimensions. This sample will be used to assess the linearity of the magnetic field gradient and to ensure authentic image reconstruction. A second major task was to secure the computer capability to enable image reconstruction from projection data generated by the magnetic field gradients. To this end, commercially available and public domain software packages which perform inverse Fourier Transform and convoluted (filtered) back projection functions are being integrated into the existing EPR data processing system.

Suleman, Naushadalli K.↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Active Control of Fan Noise-Feasibility Study. Volume 2: Canceling Noise Source-Design of an Acoustic Plate Radiator Using Piezoceramic Actuators

The feasibility of using acoustic plate radiators powered by piezoceramic thin sheets as canceling sources for active control of aircraft engine fan noise is demonstrated. Analytical and numerical models of actuated beams and plates are developed and validated. An optimization study is performed to identify the optimum combination of design parameters that maximizes the plate volume velocity for a given resonance frequency. Fifteen plates with various plate and actuator sizes, thicknesses, and bonding layers were fabricated and tested using results from the optimization study. A maximum equivalent piston displacement of 0.39 mm was achieved with the optimized plate samples tested with only one actuator powered, corresponding to a plate deflection at the center of over 1 millimeter. This is very close to the deflection required for a full size engine application and represents a 160-fold improvement over previous work. Experimental results further show that performance is limited by the critical stress of the piezoceramic actuator and bonding layer rather than by the maximum moment available from the actuator. Design enhancements are described in detail that will lead to a flight-worthy acoustic plate radiator by minimizing actuator tensile stresses and reducing nonlinear effects. Finally, several adaptive tuning methods designed to increase the bandwidth of acoustic plate radiators are analyzed including passive, active, and semi-active approaches. The back chamber pressurization and volume variation methods are investigated experimentally and shown to be simple and effective ways to obtain substantial control over the resonance frequency of a plate radiator. This study shows that piezoceramic-based plate radiators can be a viable acoustic source for active control of aircraft engine fan noise.

Pla, F. G.↗

Hyperspectral Microwave Atmospheric Sounder (HyMAS) - New Capability in the CoSMIR-CoSSIR Scanhead

Lincoln Laboratory and NASA's Goddard Space Flight Center have teamed to re-use an existing instrument platform, the CoSMIR/CoSSIR system for atmospheric sounding, to develop a new capability in hyperspectral filtering, data collection, and display. The volume of the scanhead accomodated an intermediate frequency processor(IFP), that provides the filtering and digitization of the raw data and the interoperable remote component (IRC) adapted to CoSMIR, CoSSIR, and HyMAS that stores and archives the data with time tagged calibration and navigation data. The first element of the work is the demonstration of a hyperspectral microwave receiver subsystem that was recently shown using a comprehensive simulation study to yield performance that substantially exceeds current state-of-the-art. Hyperspectral microwave sounders with approximately 100 channels offer temperature and humidity sounding improvements similar to those obtained when infrared sensors became hyperspectral, but with the relative insensitivity to clouds that characterizes microwave sensors. Hyperspectral microwave operation is achieved using independent RF antenna/receiver arrays that sample the same area/volume of the Earth's surface/atmosphere at slightly different frequencies and therefore synthesize a set of dense, finely spaced vertical weighting functions. The second, enabling element of the proposal is the development of a compact 52-channel Intermediate Frequency processor module. A principal challenge in the development of a hyperspectral microwave system is the size of the IF filter bank required for channelization. Large bandwidths are simultaneously processed, thus complicating the use of digital back-ends with associated high complexities, costs, and power requirements. Our approach involves passive filters implemented using low-temperature co-fired ceramic (LTCC) technology to achieve an ultra-compact module that can be easily integrated with existing radio frequency front-end technology. This IF processor is universally applicable to other microwave sensing missions requiring compact IF spectrometry. The data include 52 operational channels with low IF module volume (less than 100 cubic centimeters) and mass (less than 300 grams) and linearity better than 0.3 percent over a 330,000 dynamic range.

multispectral↗

Physics-based dimension reduction in uncertainty quantification for radiative transfer

We present a physics-based methodology for quantifying the uncertainty in a given quantity of interest (QOI) that is contributed by uncertainties in opacities in radiation transport problems. Typically, opacities are tabulated as a function of density, temperature, and photon energy group. The size of this table makes a study of uncertainties at this level challenging because of the well-known 'curse of dimensionality.' We address this by studying uncertain parameters in the underlying physical model that generates the opacity tables. At this level, there are fewer uncertain parameters but still too many to analyze directly through computationally expensive radiation transport simulations. In order to explore this large uncertain parameter space, we develop two simplified radiation transport problems that are much less computationally demanding than the target problem of interest. An emulator is created for each QOI for each simplified problem using Bayesian Multivariate Adaptive Regression Splines (BMARS). This emulator is used to create a functional relationship between the QOIs and the uncertain parameters. Sensitivity analysis is performed using the emulator to determine which parameters contribute significantly to the uncertainty. This physics-based screening process reduces the dimension of the parameter space that is then studied via the computationally expensive radiation transport calculation to generate distributions of quantities of interest. Results of this research demonstrate that the QOIs for the target problem agree for varying screening criteria determined by the sensitivity analysis, and the QOIs agree well for varying Latin Hypercube Design (LHD) sample sizes for the uncertain space. (authors)

97 MATHEMATICS AND COMPUTING↗

MO-FG-204-04: How Iterative Reconstruction Algorithms Affect the NPS of CT Images

Purpose: To evaluate how the third generation model based iterative reconstruction (MBIR) compares with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASiR), and the second generation MBIR based on noise power spectrum (NPS) analysis over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP515 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 19mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 0.984 pitch and reconstructed thickness 2.5mm (VEO3.0: Abd/Pelvis with Texture and NR05). At each CTDIvol level, 10 repeated scans were acquired for achieving sufficient data sampling. The images were reconstructed using Standard kernel with FBP; 20%, 40% and 70% ASiR; and two versions of MBIR (VEO2.0 and 3.0). For evaluating the effect of the ROI spatial location to the Result of NPS, 4 ROI groups were categorized based on their distances from the center of the phantom. Results: VEO3.0 performed inferiorly comparing to VEO2.0 over all dose levels. On the other hand, at low dose levels (less than 3 mGy), it clearly outperformed ASiR and FBP, in NPS values. Therefore, the lower the dose level, the relative performance of MBIR improves. However, the shapes of the NPS show substantial differences in horizontal and vertical sampling dimensions. These differences may determine the characteristics of the noise/texture features in images, and hence, play an important role in image interpretation. Conclusion: The third generation MBIR did not improve over the second generation MBIR in term of NPS analysis. The overall performance of both versions of MBIR improved as compared to other reconstruction algorithms when dose was reduced. The shapes of the NPS curves provided additional value for future characterization of the image noise/texture features.

60 APPLIED LIFE SCIENCES↗