Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WASHINGTON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Decomposition of Select Volatile Organic Compounds by Caustic Hydrolysis for Effluent Management Facility (Rev. 0)

Hydrolysis is a proposed treatment method for organic constituents at the Effluent Management Facility during the Direct-Feed Low-Activity Waste process at the Waste Treatment and Immobilization Plant. Four compounds, acetonitrile, acrylonitrile, acetone, and methylene chloride, comprise a significant portion of the organic constituents identified in the Waste Treatment and Immobilization Plant Effluent Composition Estimate. In support of the Direct-Feed Low-Activity Waste process, the Washington River Protection Solutions Organic Studies Group at the 222-S Laboratory completed a laboratory test of caustic hydrolysis reactions of these four compounds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2017

The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office has oversight and stewardship duties associated with the Pacific Northwest National Laboratory Marine Sciences Laboratory (MSL), located on Battelle Land-Sequim. The facility has two buildings with the potential to emit low levels of radioactive materials. This report is prepared to document compliance with the Code of Federal Regulation, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, Radiation Protection–Air Emissions. Compliance is indicated by comparing the estimated effective dose equivalent (EDE) to the maximally exposed individual (MEI) with the 10 millirem per year (mrem/yr) U.S. Environmental Protection Agency (EPA) standard. The MSL has only fugitive emissions sources. Despite the fact that the regulations are intended for application to point source emissions, fugitive emissions are included with regard to complying with the EPA standard. The EDE to the MSL MEI due to routine operations in 2017 was 1.6E-04 mrem (1.6E-06 mSv). No non-routine emissions occurred in 2017. The MSL is in compliance with the federal and state 10 mrem/yr standard.

40 CFR 61 Subpart H↗

Monitoring the Prototype Hanford Barrier – Fiscal Year 2017 Report

After a decade of development activities from 1983 to 1993, the 2.5-ha (6.2 acres) Prototype Hanford Barrier (PHB) was constructed between late 1993 and 1994 over the 216-B-57 Crib in the 200 East Area (46°34’01.23”N, 119°32’28.43”W) at the Hanford Site in southeastern Washington State as part of a Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) treatability test of barrier performance for the 200-BP-1 Operable Unit. The CERCLA treatability test included an enhanced precipitation stress test during the water years 1995 to 1997 to determine barrier response to extreme precipitation events and a controlled fire test in 2008 to examine the recovery of vegetation under the natural condition and the performance of the barrier with limited vegetation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PNNL Richland Campus Radionuclide Air Emissions Report for Calendar Year 2017

This report documents radionuclide air emissions that result in the 2017 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Richland Campus MEI from routine major and minor point source emissions in 2017 from PNNL Richland Campus sources is 2.1E-5 mrem (2.1E-7 mSv) EDE. The dose from all fugitive sources is 2.1E-6 mrem (2.1E-8 mSv) EDE. The dose from radon emissions is 3.9E-10 mrem (3.9E-12 mSv) EDE. No nonroutine emissions occurred in 2017. The total radiological dose to the MEI from all PNNL Richland Campus radionuclide emissions, including fugitive emissions and radon, is 2.3E-5 mrem (2.3E-7 mSv) EDE, or more than 10,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Richland Campus is in compliance.

40 CFR 61 Subpart H↗

Pacific Northwest National Laboratory Potential Impact Categories for Radiological Air Emission Monitoring

In 2002, the EPA amended 40 CFR 61 Subpart H and 40 CFR 61 Appendix B Method 114 to include requirements from ANSI/HPS N13.1-1999 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities for major emission points. Additionally, the WDOH amended the Washington Administrative Code (WAC) 246-247 Radiation protection-air emissions to include ANSI/HPS N13.1-1999 requirements for major and minor emission points when new permitting actions are approved. A result of the amended regulations is the requirement to prepare a written technical basis for the radiological air emission sampling and monitoring program. A key component of the technical basis is the Potential Impact Category (PIC) assigned to an emission point. This paper discusses the PIC assignments for the Pacific Northwest National Laboratory (PNNL) Integrated Laboratory emission units; this revision includes five PIC categories and clarifies the application of PIC 4 and PIC 5.

61 RADIATION PROTECTION AND DOSIMETRY↗

Annual Earth System Grid Federation 2019 Progress Report

Members of the Earth System Grid Federation (ESGF) gathered in Washington, DC, on December 3–7, 2018, for the 8th Annual ESGF Face-to-Face (F2F) Conference. The event packed 40 presentations, several plenary sessions, a poster session, guest speakers, an awards ceremony, and an Executive Committee (XC) meeting into the week. ESGF working teams (WTs) conduct daily operations remotely all over the world. Although most teams meet online regularly, in-person interaction is incredibly important for cementing relationships and evaluating progress.

54 ENVIRONMENTAL SCIENCES↗

Development of an Environmentally Acceptable Hydraulic Fluid

Hydroelectric plants operators like the United States Army Corps of Engineers seek their traditional petroleum-based fluids with environmentally acceptable hydraulic fluids (EAHF) to reduce their impact and liability related to spills and leakages to the water and environment. Artesion, Inc. and its sub-contractor Washington State University (WSU) sought to optimize WSU’s existing EAHF blend into an improved product that would demonstrate long-term stability while meeting the EAHF requirements of the EPA’s Vessel General Permit (VGP). Multiple rounds of Design of Experiments testing were performed from WSU’s base formulation, modifying mixing ratios to generate multiple test fluids. These fluids were then tested for hydraulic fluid properties. It was found that there was a significant tradeoff between oxidative stability and biodegradability; highly stable materials were not sufficiently biodegradable, while the highly biodegradable materials quickly failed in stability tests. After four rounds of Design of Experiments, AI and WSU had found a base fluid which met the VGP, but only had a Rotating Pressure Vessel Oxidative Test (RPVOT) of 284-minute RPVOT stability, far short of the 500-minute target that would be needed for hydroelectric plants. It was determined that WSU’s route had shown initial promise but needed more refinement to be able to produce an acceptable EAHF.

36 MATERIALS SCIENCE↗

8th Annual Earth System Grid Federation Face-to-Face Conference Report

Members of the Earth System Grid Federation (ESGF) gathered in Washington, DC, on December 3–7, 2018, for the 8th Annual ESGF Face-to-Face (F2F) Conference. The event packed 40 presentations, several plenary sessions, a poster session, guest speakers, an awards ceremony, and an Executive Committee (XC) meeting into the week. ESGF working teams (WTs) conduct daily operations remotely all over the world. Although most teams meet online regularly, in-person interaction is incredibly important for cementing relationships and evaluating progress.

54 ENVIRONMENTAL SCIENCES↗

Drying of Crystalline Silicotitanate (CST) Beds by Air Flow

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford Site. The tank farm contractor Washington River Protection Solutions, LLC (WRPS) is developing the Tank-Side Cesium Removal (TSCR) system to accomplish the treatment objectives. The TSCR system is being designed and built by AVANTech, Inc. for WRPS and will use a filter to remove any entrained solids in the LAW and will use columns of crystalline silicotitanate (CST) ion exchange media to remove 137 Cs. A key step in preparing used columns of CST for transportation and interim storage is draining and drying of the CST beds. The purpose of this study is to document testing activities that quantify the drying of full-height beds of CST material in a laboratory column that is scaled to represent the drying process of the planned full-scale CST columns to be used in the TSCR system. The purpose also includes demonstrating that CST material within the scaled column, when dried with air injection, will pass the U.S. Environmental Protection Agency’s Paint Filter Liquids Test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maximum Concentration Values Review for Use in NUCON Vapor Abatement Unit Testing

Exponent has recommended that “high inlet spike” concentrations be verified for accuracy regarding their representation of the maximum measured headspace concentrations for tanks at Hanford. Exponent further recommended that “high inlet spike” concentrations of chemicals of potential concern (COPCs) be inclusive of surrogate COPCs. In the initial analysis (Rev. A Test Plan), only analytical results from the Site-Wide Industrial Hygiene Database (SWIHD) were used. The reason for this initial decision was a concern about Washington River Protection Solutions (WRPS) taking responsibility for results that were not produced during their contract tenure. As a result of Exponent’s comments, WRPS verified the “high inlet spike” values for accuracy against the data for single-shell tanks in all the historical databases, not only SWIHD. Measurements made prior to interim waste stabilization or waste retrieval were not considered in the verification of maximum measured concentrations as they are not representative of current tank farm conditions. Data for surrogate COPCs were also considered in determining the “high inlet spike” concentrations. Table S.1 shows the newly evaluated concentrations (COPC and surrogate). The original and revised test conditions are also shown with changes indicated by red text.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Effluent Management Facility Evaporator Bottoms: Waste Streams Formulation and Waste Form Qualification Testing

This report describes the results from grout formulation and cementitious waste form testing performed by Pacific Northwest National Laboratory for Washington River Protection Solutions, LLC (WRPS). These results are part of a screening test that investigates grout formulations proposed for encapsulating a wide range of compositions predicted to be present in evaporator bottoms wastes from the Hanford Effluent Management Facility (EMF). This work supports the technical development need for alternative treatment and disposition paths for the EMF evaporator bottoms waste and future direct-feed low-activity waste (DFLAW) operations at the Hanford Site. High-priority activities included simulant production, grout formulation, and cementitious waste form testing. The work contained within this report relates to waste form development and testing, but does not directly support the 2017 Integrated Disposal Facility (IDF) performance assessment (PA). However, this work contains information useful for future PA updates [beyond fiscal year (FY) 2017] and future waste form development efforts. These analytical results can be used by (i) cementitious waste form scientists to further the understanding of cementitious leach behavior of contaminants of concern (COCs), (ii) decision makers interested in off-site waste form disposal, and (iii) the U.S. Department of Energy, their Hanford Site contractors, and stakeholders as they continue to assess the IDF PA program at the Hanford Site. The reported results help fill existing data gaps, support final selection of a cementitious waste form for the EMF evaporator bottoms waste, and improve the technical defensibility of long-term waste form risk estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2013 Actinide Separation Conference Presentations on Minor Actinide Separations by SRNL Participants [Slides]

Attached are copies of the presentations that will be given by Savannah River National Laboratory participants at the 37th Actinide Separations Conference in Spokane, Washington on June 24 – 27, 2013. This document represents the deliverable for milestone M4FT-13SR0303062, Prepare and present two papers on ion exchange separations at the 2013 Actinide Separations conference. Note that the completion of the milestone was delayed due to the rescheduling of the conference from late May 2013 to late June 2013.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cesium Removal from Tank Waste Simulants Using Crystalline Silicotitanate at 12% and 100% TSCR Bed Heights

The Direct Feed Low-Activity Waste flowsheet provides for the early production of immobilized low-activity waste (LAW) by feeding waste directly from Hanford tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank waste supernatant will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream using ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST), product number UOP-IONSIV-R9140-B, manufactured by Honeywell UOP LLC (Des Plaines, IL). Testing was requested by Washington River Protection Solutions to better define IX processing using Low-Activity Waste Pretreatment System (LAWPS) prototypic IX unit operation process steps at full height and medium height. The information is intended to significantly contribute towards establishing accurate process flowsheets for the individual feed campaigns planned for the LAWPS. Column testing at both the medium (12% of the full bed height) and full height scales was conducted to evaluate process variables and scale up performance of Cs exchange onto the CST, Lot 8056202-999. Nominal process conditions used 5.6 M Na simulant processed at 1.8 bed volumes per hour (BV/h) at 20 °C. Process variables included 1) increased process temperature to 35 °C, 2) increased Na concentration to 6.0 M, 3) added organics to the 5.6 M Na simulant, and 4) flowrate changes. The medium scale tests used single columns containing 44 mL of <25 mesh CST in a 1.44 cm diameter column, 27 cm tall CST bed. The full height columns used lead/lag columns containing 1.15 L unsieved (as-received) CST in 2.54-cm-diameter columns, 226 cm tall CST beds. Two process flowrates were tested at the full height: 1.30 and 1.82 BV/h. IX testing with simulant solutions was conducted using TSCR prototypic IX unit operations: feed processing, feed displacement with 0.1 M NaOH, water rinse, and solution expulsion with compressed air.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Avista Turner Energy Storage System: Assessment of Battery Technical Performance

This report investigates the technical performance of the 1 MW, 3.2 MWh advanced vanadium flow battery energy storage system (FBESS), consisting of two 0.5 MW, 1.6 MWh strings, based on a number of reference performance and use case tests. The FBESS is located on the utility 12 kV distribution system, between the Turner Substation and SEL’s manufacturing facility in Pullman, Washington. Reference performance tests (RPTs) were intended to assess the general technical capability of the FBESS (e.g., stored energy capacity, ramp rate performance, ability to track varying charge/discharge commands, direct current (DC) battery internal resistance). Use case tests were used to examine the performance of the FBESS while engaged in specific grid services (e.g., arbitrage, frequency regulation, balancing, volt ampere reactive (var) support, dynamic peak shaving). The project determined performance metrics that are important for understanding FBESS performance when subjected to field operation for achieving economic benefits from measurements and/or calculations. These metrics were: • RTE with and without rest, with and without auxiliary loads • Auxiliary power consumption • Reference signal tracking • Temperature excursions beyond normal operating range • Parasitic power loss unaccounted by auxiliary load during rest, and • State of charge (SOC) excursions beyond normal operating range. These RPT and use case performance metrics were analyzed using recorded test results. In addition, the results and lessons presented are also beneficial for any task or effort that needs technical assessment on similar and different types of FBESS, and BESS in general, based on technical specifications and/or field deployment results, since the assessment methodology remains the same.

25 ENERGY STORAGE↗

Understanding and Constraining the Midlatitude Cloud Optical Depth Feedback in Climate Models (Final Report)

The objectives of this investigation are to provide a deeper understanding of the brightening of middle and high latitude clouds that occurs in many climate models as the climate warms, and to better understand why models give varying estimates of the strength of this negative feedback. The investigation may also provide new information on why models are deficient in their simulation of the present day clouds in these regions. The analysis will reveal which models simulate current clouds most realistically in the regions of interest, and relate this to the strength of the cloud feedbacks in the models. This will improve the uncertainty quantification of climate simulations and will provide theoretical understanding potentially leading to increased reliability of climate change projections. This will enhance the predictive understanding of the Earth system by analyzing the natural and anthropogenic components of global climate change in models. The primary methods involve the study of the clouds in the suite of CMIP5 model climate simulations and comparison of clouds in climate simulations with data from satellite measurement systems, with a particular emphasis on mixed-phase cloud physics, for which ice and water are present simultaneously. State-of-the-art climate model feedback analysis will be combined with new and more comprehensive observations of clouds available from modern measurement systems. Novel use of model simulations in combination with observations enables a deeper understanding of the role of clouds in climate change. Metrics that facilitate model-to-model and model-to-observation comparisons related to mixed-phase cloud physics will be developed and used to highlight challenges and opportunities for improving the state-of-the-science models. This investigation is a collaboration between the University of Washington, where the data work is concentrated and LLNL where the model data and the tools and expertise to do cloud feedback analysis are located. The grant supported the work of 3 different graduate students at different times (McCoy, Wall and Berry) Post-doctoral researcher Blaž Gasparini was also partially supported on this grant and led our collaboration with PNNL scientists. PNNL scientists also collaborated in the work of graduate student Wall (Po-Lun Ma). The main results of our research efforts are reported in 6 papers and 1 book chapter that were supported by this grant.

54 ENVIRONMENTAL SCIENCES↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗