Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

VOLTTRON-enabled Home Energy Management System

Home Energy Management Systems (HEMS) consist of software and hardware systems that provide communication, control, and management among different electronic devices, such as heating, ventilation, and air-conditioning (HVAC) systems. HEMS are a growing market sector in the era of smart grids and smart homes. HEMS can help both homeowners and utilities save money and energy by monitoring and controlling smart devices in a house. Based on the Department of Energy (DOE) Building Energy Data Book, 41% of the energy consumed in the United States is used by buildings (see Figure 1). This shows the importance of saving energy in the building sector. This report introduces two approaches that existing HEMS vendors can use to leverage VOLTTRON as their control and interoperability engine. The goal of this project is to make open-source, user-friendly HEMS available to the market so that everyone can benefit from them. The HEMS introduced as a result of this study should satisfy HEMS specifications such as device monitoring and control, seamless communication between devices, DR, intelligence, data management, and security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sealed and Insulated Attic Hygrothermal Performance in New California Homes Using Vapor and Air Permeable Insulation—Field Study and Simulation

This project investigated the thermal and moisture performance of a low-cost approach to sealing and insulating attics using glass fiber insulation. The work included a combination of: (1) field measurements of attic and HVAC system performance in two new, high-performance homes in California’s Central Valley (Fresno), and (2) hygrothermal simulations of attic performance. Each field study attic was continuously monitored at multiple locations for over a year for wood moisture content, air humidity, condensation, temperature, and heat flux, together with on-site weather and solar conditions. The Fresno test home showed periodic condensation and high surface wood moisture content, but no surface mold or degradation upon visual inspection at the end of the test period. The Clovis test home showed less indication of high moisture levels—either from surface condensation or wood moisture content—but did have visible suspected mold growth on the inside of the North sheathing at the end of the field testing. These results show the limitations of current moisture measurement techniques focused on wood moisture content, rather than potential for mold growth. From a thermal/energy perspective the attics were close to indoor conditions thereby realizing the design intent for reducing duct system losses. Simulated site HVAC energy savings for sealed vs. vented attics averaged 18% across California climate regions (8% TDV energy savings). Savings were dominated by heating energy reductions; cooling savings were substantially lower. The moisture issues are investigated in greater detail in the simulations. First, we identified the climate regions and house characteristics that are associated with increased risk of mold growth or wood rot in new CA homes. Climate region was very important in determining risk, as were house features that reduced outside air exchange (e.g., 1-story homes, very tight envelopes, very tight attics, no IAQ fan), along with those that increased flow of moist air from the living space to the attic (e.g., supply ventilation fans, larger ceiling leaks, duct leakage). Second, we investigated several approaches to reduce moisture risks, and the best approach was to use a vapor retarder on the inner face of the fiberglass insulation. Both the field and simulation results indicate that the use of air and vapor permeable insulation can be acceptable from a thermal/energy point of view, but additional measures need to be taken to reduce moisture risks, primarily from mold growth.

42 ENGINEERING↗

Wall Upgrades for Residential Deep Energy Retrofits: A Literature Review

In the United States, 39% of total energy consumption comes from the building sector, 20% of which is attributed to residential buildings. New, high-performance homes incorporate a combination of tight building envelopes, mechanical ventilation and efficient components to ensure comfort, adequate airflow and moisture control. These systems work together to create energy efficient homes that employ measures to manage moisture and indoor pollutants. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established represent approximately 68% of building stock in the country, and often have significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation result in heating and cooling losses, which can represent a substantial portion of utility bills. Done correctly, deep energy retrofits (DERs) can significantly improve the energy performance of a home’s thermal envelope, decrease indoor pollutants and increase homeowner comfort. This literature review summarizes current practices for exterior wall retrofits for existing homes, provides an overview of techno-economic approaches to investigate residential wall systems, and discusses thermal and hygrothermal modeling strategies. Accompanying this literature review is a larger effort to identify state-of-the-art technologies for existing wall energy efficiency retrofit systems that can be applied over existing siding and are suitable for the cold/very cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fire- and Water-Resistant Prefilter

The goal of this project was to modify existing LLNL ceramic HEPA filter technology to create ceramic prefilters, which could first be implemented in nuclear facilities or hospitals and universities. The objectives were as follows: 1) Demonstrate sealing technology capable of withstand ≥ 400°C, 2) Design and fabricate a ceramic prefilter unit for flow rates ≥ 50 cfm, 3) Test prefilter prototype filtration efficiency and pressure drop before and after a relevant thermal exposure. Concurrently to prototype creation was a preliminary effort to develop a custom nuclear prefilter sealant, improving upon what is commercially available. An advantage to using prefilters that are not credited for HEPA filtration, but to protect HEPA filters in nuclear ventilation systems, is that absolute qualified performance to HEPA standards (e.g. pressure drop, filtration efficiency) is not required. This prefilter prototype aligns our technology with the more viable, lower risk market entry point which can be used to establish costs, performance and manufacturing principles necessary to overcome the primary market barrier.

36 MATERIALS SCIENCE↗

Summary of available data for estimating chloride-induced SCC crack growth rates for 304/316 stainless steel

The majority of existing dry storage systems used for spent nuclear fuel (SNF) consist of a welded 304 stainless steel container placed within a passively-ventilated concrete or steel overpack. More recently fielded systems are constructed with dual certified 304/304L and in some cases, 316 or 316L. In service, atmospheric salts, a portion of which will be chloride bearing, will be deposited on the surface of these containers. Initially, the stainless steel canister surface temperatures will be high (exceeding the boiling point of water in many cases) due to decay heat from the SNF. As the SNF cools over time, the container surface will also cool, and deposited salts will deliquesce to form potentially corrosive chloride-rich brines. Because austenitic stainless steels are prone to chloride-induced stress corrosion cracking (CISCC), the concern has been raised that SCC may significantly impact long-term canister performance. While the susceptibility of austenitic stainless steels to CISCC in the general sense is well known, the behavior of SCC cracks (i.e., initiation and propagation behavior) under the aforementioned atmospheric conditions is poorly understood. A literature survey has been performed to identify SCC crack growth rate (CGR) studies conducted utilizing conditions that may be relevant to existing SNF interim storage canisters, the results of which are presented in this document. The data presented here have been restricted to those representing atmospheric corrosion of stainless steels due to deliquescence of marine salts, or marine salt components, on the metal surface. A suite of experimental studies representing both long-term field tests and accelerated laboratory tests has been identified. Potentially relevant data are summarized in Figures 1-1 (304 SS) and Figure 1-2 (316 SS). In the Figures, when a particular reference utilized a series of samples, the range is shown as a bar, and the average value shown with a symbol. A summary of the test methods, sample geometry, and environmental conditions for each study is given in Table 1-1. While the surveyed studies all explore SCC of austenitic stainless steels under atmospheric conditions, the methods through which each researcher approached the problem do differ, as illustrated in Table 1-1. The surveyed studies utilized a variety of metal treatments including as-fabricated, solution annealed, welded, and sensitized material. Furthermore, different surface treatments (polished vs ground) were also used. In addition, most of these studies were accomplished using techniques that are not generally accepted for high-fidelity crack growth rate measurements, and in cases where more traditional approaches were taken, these methodologies may not be applicable to the atmospheric conditions of interest here. The wide variety of methods and materials results in the observed large scatter in measured CGRs. Each of the data sets in Figures 1-1 and 1-2 is described in more detail in the following sections. A short summary of crack growth rates based on operational experience is also presented.

36 MATERIALS SCIENCE↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

MARSAME Release Report for TA46 Building 1

Environmental Protection and Compliance, Environmental Stewardship (EPC-ES) has identified materials associated with technical area 46, Building 1 (TA-46-001) that meet the criteria for unrestricted release to the public under Department of Energy (DOE) Order 458.1 Radiation Protection for the Public and the Environment (DOE 2013). We have also identified materials in certain rooms, e.g., ventilation systems and liquid drains and piping, which do not meet the criteria for unrestricted release and are to be treated as Low Level Waste (LLW). These conclusions are based on the known history of the structures combined with radiation survey data collected in 2018, and findings are consistent with DOE Order 458.1 and Los Alamos National Laboratory (LANL) Functional Series Document EPC-ES-FSD-004, Environmental Radiation Protection (LANL 2017). Sampling and data analysis, as described in this report, were sufficient to meet measurement quality objectives under the Multi-Agency Radiation Survey and Assessment of Materials and Equipment (MARSAME) manual (MARSAME 2009) and LANL procedures (LANL 2015). Final approvals for waste disposition will come from LANL’s Waste Management Program. The scope of this final release report includes structure TA-46-001. Floorplans for building 46-001 are provided in Figures 2 through 4. Metal materials included in this report are not subject to the DOE metal moratorium. While MARSAME provides guidance on statistical sampling for residual radionuclides in bulk materials, smaller miscellaneous items can be released via the release procedures outlined in LANL Policy 121 Radiation Protection (LANL 2018).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MELCOR Modeling of Accident Scenarios at a Facility for Aqueous Reprocessing of Spent Nuclear Fuel

The work presented in this report applies the MELCOR code to evaluate potential accidents in non-reactor nuclear facilities, focusing on Design Basis Accidents. Ten accident scenarios were modeled using NRC's best-estimate severe accident analysis code, MELCOR 2.2. The accident scenarios simulated a range of explosions and/or fires related to a nuclear fuel reprocessing facility. The objective was to evaluate the radionuclide source term to the environment following initiating explosion and/or fire events. The simulations were performed using a MELCOR model of the Barnwell Nuclear Fuel Plant, which was decommissioned before beginning reprocessing operations. Five of the accident scenarios were based on the Class 5 Design Basis Accidents from the Final Safety Analysis Report. Three of the remaining accident scenarios include sensitivity studies on smaller solvent fires. The final two accidents included an induced fire from an initial explosion. The radionuclide inventory was developed from ORIGEN calculations of spent PWR fuel with an initial enrichment of 4.5% U-235 by weight. The fuel aged for five years after a final 500-day irradiation cycle. The burn-up was conservatively increased to 60 GWd/MTU to bound current US operations. The results are characterized in terms of activity release to the environment and the building decontamination factor, which is related the leak path factor used in Department of Energy safety analyses. The MELCOR 2.2 results consider adverse consequences to the filters, ventilation system, and structures as a result of the explosions and fires. The calculations also include best-estimate models for aerosol transport, agglomeration, and deposition. The new calculations illustrate best-estimate approaches for predicting the source term from a reprocessing facility accident.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Protocol for Determining Actual Flow Rate in FTWC Duct Systems

This paper is intended to document the theory and methods to determine the actual flow rate in the exhaust system used to ventilate the Flanged Tritium Waste Containers based on realtime instrument readings. Section 1 provides introductory and background material; Section 2 details the various correction factors used to adjust flow readings for ambient air pressure and temperature and other operational parameters. Section 3 provides guidance on implementing this process during venting operations, and Section 4 provides supporting documentation and also a field checklist that can be used by personnel during venting. For Revision 1, a summary of editorial changes made to the paper was added as Section 4.4, as well as a section documenting peer review (Section 4.5).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigations of Dual-Purpose Canister Direct Disposal Feasibility (FY14)

Results reported here continue to support the FY13 conclusion that direct disposal of DPCs is technically feasible, at least for some DPCs, and for some disposal concepts (geologic host media). Much of the work performed has reached a point where site-specific information would be needed for further resolution. Several activities in FY14 have focused on clay/shale media because of potential complications resulting from low thermal conductivity, limited temperature tolerance, and the need to construct hundreds of kilometers of emplacement drifts that will remain stable for at least 50 years. Technologies for rapid excavation and liner installation have significantly advanced in the past 20 years. Tunnel boring machines are the clear choice for large-scale excavation. The first TBM excavations, including some constructed in clay or shale media, are now approaching 50 years of service. Open-type TBMs are a good choice but the repository host formation would need to have sufficient compressive strength for the excavation face to be self-supporting. One way to improve the strength-stress relationship is to reduce the repository depth in soft formations (e.g., 300 m depth). The fastest construction appears to be possible using TBMs with a single-pass liner made of pre-fabricated concrete segments. Major projects have been constructed with prefabricated segmented liner systems, and with cast-in-place concrete liners. Cost comparisons show that differences in project management and financing may be larger cost factors than the choice of liner systems. Costs for large-scale excavation and construction in clay/shale media vary widely but can probably be limited to $10,000 per linear meter, which is similar to previous estimates for repository construction. Concepts for disposal of DPC-based waste packages in clay/shale media are associated with thermal management challenges because of the relatively low thermal conductivity and limited temperature tolerance. Peak temperature limits of 100°C or lower for clay-rich materials have been selected by some international programs, but a limit above 100°C could help to shorten the duration of surface decay storage and repository ventilation. The effects of locally higher peak temperatures on repository performance need to be evaluated (in addition to the effects at lower temperatures). This report describes a modeling approach that couples the TOUGH2 and FLAC3D codes to represent thermally driven THM processes, as a demonstration of the types of models needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulating Buildings While the Design is Still in the Architect's Imagination

Very early in the design process, prior to drawing a single line, architects get information from their client or prospective client trying to understand the nature and requirements of the building that needs to be designed. The design of the building is completely fluid, as the architect considers many options in their imagination. The overall massing of the building, the general shape and form, are being considered during this early step. Even for a simple box-shaped building, the aspect ratio between the east-west and the north-south dimensions of the building can greatly impact energy consumption due to daylighting availability. The prevailing winds and building orientation can impact natural ventilation. The locations of high and low population density spaces can also impact energy use. Deciding the floor area per office workstation or the size of the auditorium will impact energy use. Does making a building two stories instead of one reduce energy impacts by reducing roof area or does the additional volume for stairs and elevators result in more energy use. Since certain types of spaces require more windows for occupants than others, the locations of those spaces will determine how much glazing each building orientation has impacting daylighting as well as heating and cooling energy. The project was an attempted first step toward creating a system tailored toward architects for this very early stage in the design process to help them understand the energy impacts of design options. The approach was not to be based on drawing the building, and instead, the main inputs would have been the size of each type of space in the building. This report describes information gathered during the development that might be of use to others developing similar software as well as some of the software that was developed during the project. Phase II funding to continue this work was not pursued due to intellectual property issues discovered during the development of the commercialization plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Update on the Thermal Hydraulic Investigations of a Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a canister in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the present investigation is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) has been designed to generate this benchmark data and add to the existing knowledge base. The objective of the HDCS investigation is to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for any given set of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ford Thermoelectric HVAC Project (Final Report)

Current light-duty vehicles provide passenger thermal comfort primarily through the use of a centralized HVAC (Heating, Ventilation, and Air Conditioning) unit that distributes conditioned air to vent locations throughout the vehicle. A substantial portion of the air energy content is spent conditioning various elements of the vehicle's interior structures. This is not an overwhelming issue in today’s vehicles, but as pressure builds to improve powertrain efficiency, the energy available to provide occupant comfort will decrease. Thermoelectric devices were identified by the US Department of Energy as one method to potentially reduce HVAC-related energy consumption in vehicles. The objective of the Ford Thermoelectric HVAC Project was to identify a technical and business approach to accelerate research and development of light-duty automotive thermoelectric HVAC technology. A zonal HVAC system was developed to provide thermal comfort to each occupant, with the objective of reducing the overall power consumed by the HVAC system compared with a baseline system. The system was designed to provide a basis for a down-sized central HVAC unit, while providing equivalent comfort and equivalent heating/cooling time-to-comfort at startup, and reduce the energy consumed to provide these functions. Project success was evaluated using occupant comfort and energy consumption metrics, based on a novel thermal comfort-modeling approach, and empirical testing. The ability to produce and market the thermoelectric devices developed in this program was assessed by a business analysis that outlined key steps required for thermoelectric HVAC devices to come to market. Key hardware and controls attribute requirements were identified to determine how they contribute to the commercialization potential of the technology. Final testing and analysis showed that use of thermal comfort and zonal design criteria reduced the energy consumption of the climate control system in both heating and cooling tests, and were significantly better in low vehicle occupancy cases where zonal strategies could be employed. Thermoelectric devices were utilized in the vehicle design to support achieving the technical performance goals of the project. It was found that these devices need additional development in order to address commercial issues, due to their cost and performance limitations.

99 GENERAL AND MISCELLANEOUS↗

Accelerated Climate Model for Energy (ACME): Ocean and Sea-Ice Processes

The primary goal of this project was to understand the role of the ocean and sea-ice components in the evolution of the climate in both a high-resolution fully-coupled 1850 preindustrial control and present day transient climate simulations run using the Energy Exascale Earth System Model (E3SM), formerly known as the Accelerated Climate Model for Energy (ACME). Two distinct approaches to the initialization of the present day transients were tested: in the first, an ensemble of three transients used atmospheric reanalysis forced 0.1-degree ocean/sea-ice states, while a fourth transient was branched off the preindustrial control. Biases from the control were inherited by its successor transient, in particular, sea surface temperatures (SSTs) at high latitudes were too warm and too much northward meridional heat transport occurred in the North Atlantic Ocean. SSTs in the Northern Hemisphere and Atlantic meridional heat transport increased in the transients initialized from the ocean/sea-ice simulation over a 40-50 year period to largely resemble the transient branched off the control simulation. Excessive absorbed solar radiation (ASR) is considered to be responsible for the SST biases as well as the formation of mode waters in lighter density classes than in reality both in the Southern Ocean and the North Atlantic Ocean subtropical gyre. These mode waters ventilate the thermocline waters to the north of their formation sites explaining the excessive Atlantic meridional heat transport and some of the warming in the high-latitude North Atlantic Ocean after multiple decades.

54 ENVIRONMENTAL SCIENCES↗

Smart technologies enable homes to be efficient and interactive with the grid

Oak Ridge National Laboratory researchers compare two different approaches to test how advanced, energy-efficient building technologies such as smart thermostats, heat pump water heaters, and advanced heat pump HVAC (heating, ventilation and air conditioning) can be optimized within a home and connected at a neighborhood-scale load to a community microgrid in the Alabama Power Smart Neighborhood located in Hoover. Working with Southern Company and Alabama Power, ORNL researchers are pioneering that future where smart homes and smart neighborhoods can benefit both homeowners and utilities, by reducing energy consumption by 44% and peak demand by 34%.This project is one of two neighborhoods in the U.S Department of Energy’s (DOE’s) Connected Neighborhood project, supported by Building Technologies Office , where ORNL researchers leverages DOE investment in micro-grids and responsive, flexible building loads research to improve grid reliability – a goal of DOE’s Grid-interactive Efficient Buildings (GEB) Initiative. Researchers control the neighborhood and microgrid to enable utilities achieve their desired load and cost profiles while ensuring the comfort of homeowners in the Smart Neighborhood. This transactive control approach maximizes the utilization of technical resources of the microgrid and controllable loads, while reducing costs for both the homeowners and Alabama Power. These tests partially seek to determine a more precise range of tolerance with respect to occupant comfort as researchers work to facilitate customer acceptance and perception of new building technologies that enable energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pathogen Management Kit (Technical Bulletin)

Sandia National Laboratories (SNL) has developed and produced a simple add-on kit (Pathogen Management Kit, or PMK) that can quickly add on to ventilators of all types to disinfect exhaled air to keep healthcare workers safe.

42 ENGINEERING↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗